Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Se Pu ; 42(5): 445-451, 2024 Apr 08.
Artigo em Chinês | MEDLINE | ID: mdl-38736387

RESUMO

Mycotoxins are toxic secondary metabolites produced by fungal species that can cause acute, subacute, and chronic toxicity in humans and animals. Thus, these toxins pose a significant threat to health and safety. Owing to the lack of effective antimold measures in the agricultural industry, feed ingredients such as corn, peanuts, wheat, barley, millet, nuts, oily feed, forage, and their byproducts are prone to mold and mycotoxin contamination, which can affect animal production, product quality, and safety. Cyclopiazonic acid (CPA), which is mainly biosynthesized from mevalonate, tryptophan, and diacetate units, is a myotoxic secondary metabolite produced by Penicillium and Aspergillus fungi. CPA is widely present as a copollutant with aflatoxins in various crops. Compared with some common mycotoxins such as aflatoxins, fumonisins, ochratoxins, zearalenones, and their metabolites, CPA has not been well investigated. In the United States, a survey showed that 51% of corn and 90% of peanut samples contained CPA, with a maximum level of 2.9 mg/kg. In Europe, CPA was found in Penicillium-contaminated cheeses as high as 4.0 mg/kg. Some studies have shown that CPA can cause irreversible damage to organs such as the liver and spleen in mice. Therefore, the establishment of a rapid and efficient analytical method for CPA is of great significance for the risk assessment of CPA in feeds, the development of standard limits, and the protection of feed product quality and safety. The QuEChERS method, a sample pretreatment method that is fast, simple, cheap, effective, and safe, is widely used in the analysis of pesticide residues in food. In this study, a modified QuEChERS method combined with ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was used to determine CPA levels in feeds. The chromatographic separation and MS detection of CPA as well as the key factors affecting the extraction efficiency of CPA, including the type of extraction solvent, type of inorganic salt, and type and dosage of adsorbent, were optimized in detail. During the optimization of the chromatographic-separation step, the acid and salt concentrations of the mobile phase affected the separation and detection of CPA. During the optimization of the QuEChERS method, the addition of a certain amount of acetic acid improved the extraction efficiency of CPA because of its acidic nature; in addition, GCB and PSA significantly adsorbed CPA from the feed extract. Under optimal conditions, the CPA in the feed sample (1.0 g) was extracted with 2 mL of water and 4 mL of acetonitrile (ACN) containing 0.5% acetic acid. After salting out with 0.4 g of NaCl and 1.6 g of MgSO4, 1 mL of the ACN supernatant was purified by dispersive solid-phase extraction using 150 mg of MgSO4 and 50 mg of C18 and analyzed by UPLC-MS/MS. The sample was separated on a Waters HSS T3 column (100 mm×2.1 mm, 1.8 µm) using 2 mmol/L ammonium acetate aqueous solution with 0.5% formic acid and ACN as the mobile phases and then analyzed by positive electrospray ionization in multiple reaction monitoring mode. CPA exhibited good linearity in the range of 2-200 ng/mL, with a high correlation coefficient (r=0.9995). The limits of detection and quantification of CPA, which were calculated as 3 and 10 times the signal-to-noise ratio, respectively, were 0.6 and 2.0 µg/kg, respectively. The average recoveries in feed samples spiked with 10, 100, and 500 µg/kg CPA ranged from 70.1% to 78.5%, with an intra-day precision of less than 5.8% and an inter-day precision of less than 7.2%, indicating the good accuracy and precision of the proposed method. Finally, the modified QuEChERS-UPLC-MS/MS method was applied to the analysis of CPA in 10 feed samples obtained from Wuhan market. The analysis results indicated that the developed method has good applicability for CPA analysis in feed samples. In summary, an improved QuEChERS method was applied to the extraction and purification of CPA from feeds for the first time; this method provides a suitable analytical method for the risk monitoring, assessment, and standard-limit setting of CPA in feed samples.


Assuntos
Ração Animal , Contaminação de Alimentos , Indóis , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Ração Animal/análise , Cromatografia Líquida de Alta Pressão/métodos , Contaminação de Alimentos/análise , Indóis/análise , Micotoxinas/análise
2.
J Sep Sci ; 39(11): 2196-203, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27280701

RESUMO

Solid-phase extraction based on humic acid bonded silica followed by gas chromatography with electron capture detection was developed to determine fipronil and its metabolites in edible oil. To achieve the best extraction performance, we systematically investigated a series of solid-phase extraction parameters. Under the optimized conditions, the method was validated according to linearity, recovery, and precision. Good linearities were obtained with R(2) more than 0.9996 for all analytes. The limits of detection were between 0.3 and 0.5 ng/g, and the recoveries ranged from 83.1 to 104.0% at three spiked concentrations with intra- and interday relative standard deviation values less than 8.7%. Finally, the proposed method was applied to determine fipronil and its metabolites in 11 edible oil samples taken from Wuhan markets. Fipronil was detectable in four samples with concentrations ranging from 3.0 to 5.2 ng/g. In China, the maximum residue limits of fipronil in some vegetables and maize are 20 and 100 ng/g (GB/T 2763-2014), respectively. The residues of fipronil and its metabolites in commercial edible oils might exhibit some potential threat to human health as a result of high consumption of edible oil as part of daily intake.


Assuntos
Elétrons , Substâncias Húmicas , Óleos de Plantas/química , Pirazóis/análise , Dióxido de Silício/química , Extração em Fase Sólida , Cromatografia Gasosa , Pirazóis/metabolismo
3.
Talanta ; 132: 118-25, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25476287

RESUMO

A novel mesoporous ZrO2 immobilized magnetic Fe3O4 microsphere (m-ZrO2@Fe3O4) was successfully synthesized and characterized by transmission electron microscope (TEM), X-ray diffractometer (XRD), nitrogen adsorption measurement (NAM), energy-dispersive X-ray analysis (EDX), vibrating sample magnetometer (VSM). Then the resultant m-ZrO2@Fe3O4 and an n-octadecylphosphonic acid modified magnetic microsphere (Fe3O4-OPA) were employed as clean-up co-adsorbents of QuEChERS (Quick, Easy, Cheap, Effective, Rugged, Safe) method for the analysis of 42 pesticides and 7 polychlorinated biphenyls (PCBs) in fish samples. Lipid co-extractives such as fatty acids in QuEChERS extracts could be efficiently removed through the Lewis acid-Lewis base interaction between m-ZrO2@Fe3O4 and carboxylic groups, while some other apolar interferents could be adsorbed through hydrophobic interaction by Fe3O4-OPA. Meanwhile, the magnetic property of adsorbents endows the clean-up procedure with manipulative convenience. Several parameters affecting the clean-up performance were investigated. Under the optimal conditions, the modified QuEChERS method combined with gas chromatography-tandem mass spectrometry (GC-MS/MS) for the multi-class, multi-residue analysis of pesticides and PCBs in fish samples was validated according to linearility, recovery and precision. Good linearities were obtained for all analytes with R(2) larger than 0.9903. Limits of detection (LODs) were found to be in the range of 0.02-4.40 ng/g. The method recoveries of all analytes spiked at three concentration levels in blank fish samples were from 69.8% to 117.1%, with the intra-day and inter-day relative standard deviations (RSDs) less than 13.4% and 16.5%, respectively.


Assuntos
Óxido Ferroso-Férrico/química , Contaminação de Alimentos/análise , Praguicidas/isolamento & purificação , Bifenilos Policlorados/isolamento & purificação , Microextração em Fase Sólida/métodos , Zircônio/química , Animais , Peixes/metabolismo , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Limite de Detecção , Imãs , Microesferas , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
4.
J Chromatogr A ; 1218(52): 9314-20, 2011 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-22129571

RESUMO

In this paper, two phenothiazine bonded silica (PTZ-Si) sorbents were prepared and used as sorbents of solid-phase extraction (SPE) for the determination of nitrobenzene compounds in environmental water samples by gas chromatography-mass spectrometry (GC-MS). Different synthesis routes were proposed to obtain high bonded amount of PTZ on the surface of silica gel. PTZ molecule was derived to its amino or acyl chloride derivatives for reacting with isocyanate or amino silane coupling agent, which was further reacted with the surface silanol groups of silica gel to obtain the PTZ-Si sorbents. The resultant PTZ-Si sorbents were characterized by nitrogen sorption porosimetry (NSP), Fourier transform infrared spectroscopy (FT-IR) and elemental analysis (EA) to assure the successful bonding of PTZ on the surface of silica gel. Then the PTZ-Si sorbents were served as SPE sorbents for the enrichment of nitrobenzene compounds. Several parameters affecting the extraction performance were investigated. Under the optimized conditions, the proposed method was applied to the analysis of six nitrobenzene compounds in environmental water samples. Good linearities were obtained for all nitrobenzene compounds with R(2) larger than 0.9958. The limits of detection were found to be in the range of 0.06-0.3 ng/mL. The method recoveries of nitrobenzene compounds spiked in water samples were from 71.4% to 124.3%, with relative standard deviations (RSDs) less than 10.1%.


Assuntos
Dinitrobenzenos/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Fenotiazinas/química , Extração em Fase Sólida/métodos , Tolueno/análogos & derivados , Poluentes Químicos da Água/análise , Dinitrobenzenos/isolamento & purificação , Água Doce/química , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes , Sílica Gel/química , Espectroscopia de Infravermelho com Transformada de Fourier , Tolueno/análise , Tolueno/isolamento & purificação , Poluentes Químicos da Água/isolamento & purificação
5.
J Sep Sci ; 34(22): 3123-30, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21998034

RESUMO

A novel hydrophilic polymer-coated silica sorbent has been prepared using the radical "grafting from" polymerization method through surface-bound azo initiators for hydrophilic-interaction chromatography (HILIC). The azo groups were introduced to the surface of silica gel through the reaction with amino groups on the surface of silica gel with 4,4'-azobis(4-cyanopentanoic acid chloride) (ACVC). The resultant azo-immobilized silica gel served as surface initiator to polymerize hydrophilic triol acrylamide monomer N-acryloyltris(hydroxymethyl) aminomethane (NA) in methanol to get hydrophilic polymer-coated silica sorbent. The obtained poly(NA)-coated silica (pNA-sil) was characterized by Fourier transform infrared spectroscopy (FT-IR), elemental analysis (EA), and nitrogen sorption porosimetry (NSP). Then the pNA-sil was packed into the stainless-steel column and evaluated in high-performance liquid chromatography (HPLC). Good chromatographic performance for the separation of peptides and nucleosides was obtained under HILIC mode. The results indicated that the pNA-sil stationary phase behaved as mixed-mode retention mechanisms of hydrophilic and ionic interactions. Furthermore, the pNA-sil phase was used to separate tryptic digest of ß-casein and our results showed that more than 12 peptides peaks were resolved and well distributed within the elution window. Finally, the pNA-sil stationary phase was demonstrated to possess remarkable reproducibility and stability. Taken together, the pNA-sil stationary phase prepared in the current study offers a potential application in proteomics study.


Assuntos
Acrilamida/química , Cromatografia Líquida de Alta Pressão/instrumentação , Nucleosídeos/isolamento & purificação , Peptídeos/isolamento & purificação , Polímeros/química , Dióxido de Silício/química , Cromatografia Líquida de Alta Pressão/métodos , Interações Hidrofóbicas e Hidrofílicas , Nucleosídeos/química , Peptídeos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA