Eur Arch Otorhinolaryngol ; 281(7): 3433-3441, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38180608

RESUMO

PURPOSE:  Vestibular implant electrode positioning close to the afferent nerve fibers is considered to be key for effective and selective electrical stimulation. However, accurate positioning of vestibular implant electrodes inside the semicircular canal ampullae is challenging due to the inability to visualize the target during the surgical procedure. This study investigates the accuracy of a new surgical protocol with real-time fluoroscopy and intraoperative CT imaging, which facilitates electrode positioning during vestibular implant surgery. METHODS:  Single-center case-controlled cohort study with a historic control group at a tertiary referral center. Patients were implanted with a vestibulocochlear implant, using a combination of intraoperative fluoroscopy and cone beam CT imaging. The control group consisted of five patients who were previously implanted with the former implant prototype, without the use of intraoperative imaging. Electrode positioning was analyzed postoperatively with a high-resolution CT scan using 3D slicer software. The result was defined as accurate if the electrode position was within 1.5 mm of the center of the ampulla. RESULTS: With the new imaging protocol, all electrodes could be positioned within a 1.5 mm range of the center of the ampulla. The accuracy was significantly higher in the study group with intraoperative imaging (21/21 electrodes) compared to the control group without intraoperative imaging (10/15 electrodes), (p = 0.008). CONCLUSION:  The combined use of intraoperative fluoroscopy and CT imaging during vestibular implantation can improve the accuracy of electrode positioning. This might lead to better vestibular implant performance.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Humanos , Fluoroscopia/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Estudos de Casos e Controles , Tomografia Computadorizada de Feixe Cônico/métodos , Eletrodos Implantados , Adulto , Tomografia Computadorizada por Raios X/métodos , Cirurgia Assistida por Computador/métodos
2.
Eur Arch Otorhinolaryngol ; 279(12): 5601-5613, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35536383

RESUMO

PURPOSE: The goal of this study was to evaluate if bilaterally (partially) absent vestibular function during static sound localization testing, would have a negative impact on sound localization skills. Therefore, this study compared horizontal static sound localization skills of normal-hearing patients with bilateral vestibulopathy (BV) and healthy controls. METHODS: Thirteen normal-hearing patients with BV and thirteen age-matched healthy controls were included. Sound localization skills were tested using seven loudspeakers in a frontal semicircle, ranging from - 90° to + 90°. Sound location accuracy was analyzed using the root-mean-square error (RMSE) and the mean absolute error (MAE). To evaluate the severity of the BV symptoms, the following questionnaires were used: Dizziness Handicap Inventory (DHI), Oscillopsia severity questionnaire (OSQ), 12-item Spatial, Speech, and Qualities Questionnaire (SSQ12), and Health Utilities Index Mark 3 (HUI3). RESULTS: The RMSE and MAE were significantly larger (worse) in the BV group than in the healthy control group, with respective median RMSE of 4.6° and 0°, and a median MAE of 0.7° and 0°. The subjective reporting of speech perception, spatial hearing, and quality of life only demonstrated a moderate correlation between DHI (positive correlation) and HUI total score (negative correlation), and localization scores. CONCLUSION: Static sound localization skills of patients with BV were only mildly worse compared to healthy controls. However, this difference was very small and therefore most likely due to impaired cognitive function. The vestibular system does not seem to have a modulating role in sound localization during static conditions, and its impact is negligible in contrast to the impact of hearing impairment. Furthermore, the subjective reporting of speech perception, spatial hearing, and quality of life was not strongly correlated with localization scores.


Assuntos
Vestibulopatia Bilateral , Implante Coclear , Implantes Cocleares , Perda Auditiva , Localização de Som , Percepção da Fala , Humanos , Perda Auditiva/cirurgia
3.
PLoS One ; 15(3): e0228768, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32150553

RESUMO

OBJECTIVES: To identify predictive factors for falls in patients with bilateral vestibulopathy (BV). Specific variables contributing to the general work-up of a vestibular patient were compared between BV patients experiencing falls and those who did not. DESIGN: Prospective multi-centric cohort study. SETTING: Department of Otorhinolaryngology & Head and Neck Surgery at two tertiary referral centers: Antwerp University Hospital and Maastricht University Medical Center. PARTICIPANTS: In total, 119 BV patients were included. BV diagnosis was defined in accordance with the diagnostic BV criteria, established by the Bárány Society in 2017. MAIN OUTCOME MEASURES: Patients were divided into fallers and non-fallers, depending on the experience of one or more falls in the preceding 12 months. Residual vestibular function on caloric testing, rotatory chair testing, video head impulse test (vHIT) and cervical vestibular evoked myogenic potentials (cVEMP) was evaluated as a predictive factor for falls. Furthermore, hearing function (speech perception in noise (SPIN)), sound localization performance, etiology, disease duration, sport practice, scores on the Dizziness Handicap Inventory (DHI) and the Oscillopsia Severity Questionnaire (OSQ) were compared between fallers and non-fallers. RESULTS: Forty-five (39%) patients reported falls. In a sub-analysis in the patients recruited at UZA (n = 69), 20% experienced three or more falls and three patients (4%) suffered from severe fall-related injuries. The DHI score and the OSQ score were significantly higher in fallers. Residual vestibular function, SPIN, sound localization performance, etiology, disease duration, age and sport practice did not differ between fallers and non-fallers. CONCLUSIONS: Falls and (severe) fall-related injuries are frequent among BV patients. A DHI score > 47 and an OSQ score > 27.5 might be indicative for BV patients at risk for falls, with a sensitivity of 70% and specificity of 60%. Residual vestibular function captured by single vestibular tests (vHIT, calorics, rotatory chair, cVEMP) or by overall vestibular function defined as the number of impaired vestibular sensors are not suitable to distinguish fallers and non-fallers in a BV population.


Assuntos
Acidentes por Quedas/estatística & dados numéricos , Audiometria da Fala/métodos , Vestibulopatia Bilateral/diagnóstico , Testes Calóricos/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Vestibulopatia Bilateral/complicações , Vestibulopatia Bilateral/fisiopatologia , Estudos de Coortes , Feminino , Teste do Impulso da Cabeça , Humanos , Masculino , Pessoa de Meia-Idade , Equilíbrio Postural , Estudos Prospectivos , Medição de Risco , Sensibilidade e Especificidade , Inquéritos e Questionários , Centros de Atenção Terciária , Potenciais Evocados Miogênicos Vestibulares , Adulto Jovem
4.
Front Neurol ; 8: 137, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28443060

RESUMO

OBJECTIVE: The vestibular implant seems feasible as a clinically useful device in the near future. However, hearing preservation during intralabyrinthine implantation remains a challenge. It should be preserved to be able to treat patients with bilateral vestibulopathy and (partially) intact hearing. This case study investigated the feasibility of hearing preservation during the acute phase after electrode insertion in the semicircular canals. METHODS: A 40-year-old woman with normal hearing underwent a translabyrinthine approach for a vestibular schwannoma Koos Grade IV. Hearing was monitored using auditory brainstem response audiometry (ABR). ABR signals were recorded synchronously to video recordings of the surgery. Following the principles of soft surgery, a conventional dummy electrode was inserted in the lateral semicircular canal for several minutes and subsequently removed. The same procedure was then applied for the posterior canal. Finally, the labyrinthectomy was completed, and the schwannoma was removed. RESULTS: Surgery was performed without complications. No leakage of endolymph and no significant reduction of ABR response were observed during insertion and after removal of the electrodes from the semicircular canals, indicting no damage to the peripheral auditory function. The ABR response significantly changed when the semicircular canals were completely opened during the labyrinthectomy. This was indicated by a change in the morphology and latency of peak V of the ABR signal. CONCLUSION: Electrode insertion in the semicircular canals is possible without acutely damaging the peripheral auditory function measured with ABR, as shown in this proof-of-principle clinical investigation.