Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Klin Monbl Augenheilkd ; 240(4): 449-455, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37164442

RESUMO

BACKGROUND: It is known that cataract extraction is associated with a significant reduction in intraocular pressure, especially in narrow angled eyes; however, the modifications of anterior segment parameters associated with this phenomenon have still not been completely defined. The purpose of this study was to evaluate changes in anterior segment anatomy and intraocular pressure after cataract surgery in non-glaucomatous eyes. METHODS AND MATERIAL: This retrospective case series study included 64 eyes of 64 consecutive patients who underwent phacoemulsification with intraocular lens implantation. Anterior segment parameters and intraocular pressure were assessed and compared before and 6 months after surgery. Anterior segment imaging was performed using Casia SS-1000 anterior segment optical coherence tomography (Tomey, Nagoya, Japan). Anterior segment measurements included anterior chamber depth, anterior chamber width, anterior chamber volume, angle opening distance at 500 µm anterior to the scleral spur, angle recess area 750 µm from the scleral spur, lens vault, trabecular iris space area at 500 µm from the scleral spur, and trabecular iris angle at 500 µm from the scleral spur. Intraocular pressure was measured using the Goldmann applanation tonometer (Model AT 900 C/M, Haag-Streit, Bern, Switzerland). Anterior segment parameters and the relationship of changes in intraocular pressure were also evaluated. RESULTS: All anterior segment parameters increased significantly after surgery (p < 0.05). Both angle opening distance at 500 µm anterior to the scleral spur and anterior chamber depth changes were positively correlated with the preoperative lens vault. The mean intraocular pressure significantly decreased from 14.91 mmHg (± 2.8 SD) to 12.91 mmHg (± 3.13 SD) (p < 0.001). Changes in intraocular pressure correlated negatively with values for the width of the preoperative anterior chamber (r = - 0.533; p = 0.001). CONCLUSION: Cataract surgery led to significant widening of the anterior chamber angle and lowering of intraocular pressure. Further investigations are needed to better understand whether anterior chamber width may be a new independent predictive factor for reduction in postoperative intraocular pressure.


Assuntos
Catarata , Oftalmopatias , Glaucoma de Ângulo Fechado , Humanos , Pressão Intraocular , Estudos Retrospectivos , Implante de Lente Intraocular , Tonometria Ocular , Câmara Anterior/diagnóstico por imagem , Iris , Tomografia de Coerência Óptica , Segmento Anterior do Olho/diagnóstico por imagem
2.
J Ophthalmol ; 2019: 5986895, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31662896

RESUMO

PURPOSE: The aim of this retrospective cohort study was to evaluate intraocular pressure (IOP) changes during femtosecond laser-assisted cataract surgery (FLACS) using two different patient interface systems. METHODS: 116 eyes of 116 patients scheduled for cataract surgery were divided into 2 groups: group 1 (61 eyes) and group 2 (55 eyes) underwent FLACS using Catalys Laser with fluid interface (liquid optics interface, LOI) and LenSx Laser with curved interface and soft contact lens (SoftFit), respectively. IOP was assessed using a portable rebound tonometer (Icare®) preoperatively, after docking, immediately after surgery, at one and seven days postoperatively. RESULTS: In group 1, the mean IOP (±SD) was 14.1 ± 0.4 mmHg before surgery, 33.2 ± 1.1 mmHg after docking, and 21.4 ± 0.9 mmHg immediately after surgery. In group 2, the mean IOP was 13.8 ± 0.4 mmHg before surgery, 24.2 ± 1.4 mmHg after docking, and 20.2 ± 1.2 mmHg immediately after surgery. After the docking procedure, a statistically significant increase in IOP from the baseline was found in both groups (p < 0.001). Moreover, no statistically significant difference in IOP measured at 1 and 7 days postoperatively was observed compared with the preoperative values (p > 0.05) using both laser platforms. No intraoperative and postoperative complications were observed. CONCLUSIONS: FLACS suction phase resulted in a transient increase of IOP in both groups, especially with the LOI system, and it is probably related to the greater pressure of a suction ring and suction generated through the vacuum, independently from the effect of femtosecond laser itself.

3.
Int Ophthalmol ; 39(8): 1695-1701, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29992516

RESUMO

PURPOSE: To describe the macroscopic characteristics of the subretinal fluid (SRF) and its spilling modality during evacuative puncture in scleral buckling (SB) surgery for rhegmatogenous retinal detachment. METHODS: We retrospective reviewed all the SB surgeries performed over a period of 26 months at the University Eye Clinic of Trieste, Italy. We selected a cohort of 102 patients in which SRF drainage by means of evacuative puncture was performed. A high-definition video was recorded during the whole duration of the procedures, and the macroscopic characteristics of the SRF leakage were assessed. RESULTS: Pigmented dark-brownish deposits spilling in the fluid outcoming from the evacuative puncture was observed during the surgeries. In all cases, this macroscopic feature was detected during the late phases of the drainage. Moreover, indirect ophthalmoscopic evaluation showed the almost complete SRF drainage and a flattened retina at that moment. CONCLUSIONS: The pigment stream sign, easily detectable by the surgeon, allows to understand, during the evacuative puncture, when the SRF has been drained almost completely and that the drainage procedure is therefore close to the end.


Assuntos
Drenagem/métodos , Descolamento Retiniano/cirurgia , Epitélio Pigmentado da Retina/patologia , Pigmentos da Retina/análise , Recurvamento da Esclera/métodos , Líquido Sub-Retiniano/metabolismo , Acuidade Visual , Seguimentos , Humanos , Descolamento Retiniano/diagnóstico , Epitélio Pigmentado da Retina/metabolismo , Estudos Retrospectivos
4.
J Ophthalmol ; 2018: 8620150, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30538858

RESUMO

PURPOSE: To compare the capsule edges ultrastructure obtained by two femtosecond laser-assisted cataract surgery (FLACS) platforms and manual continuous curvilinear capsulorhexis (CCC) using scanning electron microscopy (SEM). SETTING: Eye Clinic, University of Trieste, Italy. DESIGN: Experimental comparative study. METHODS: 150 anterior capsules were collected and divided into three groups as follows: Group 1 (50 capsules) obtained with manual CCC, Groups 2 and 3 (each with 50 capsules) obtained with the Catalys Laser and the LenSx Laser, respectively. All samples were imaged by means of SEM and regularity of the cut surface, and thickness of the capsule edge were evaluated and compared. RESULTS: All femtosecond laser (FSL) capsules were perfectly circular, whereas some alteration of the circular shape was observed in the manual ones. Group 1 showed a smooth and regular capsule edge without any surface irregularity, conversely Groups 2 and 3 showed postage-stamp perforations on the capsule edge. The cut surface irregularity value in Group 2 was 1.4 ± 0.63, while it was 0.7 ± 0.49 in Group 3 (p < 0.05). Group 1 had a significantly lower thickness of the capsule edge than the FSL groups (p < 0.05). No statistically significant difference in the capsule edge thickness between the FSL groups was found (p=0.244). CONCLUSIONS: Despite the presence of slight cut surface irregularities, both FSL capsulotomies showed a better geometry and circularity than the manual ones. Capsulotomy specimens obtained using both FSL capsulotomies showed laser-induced alterations of the capsule edge when compared with smooth and regular edges obtained using manual CCC.

5.
J Cataract Refract Surg ; 44(3): 376-381, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29703290

RESUMO

PURPOSE: To objectively evaluate the image quality obtained with toric intraocular lenses (IOLs) when misaligned from the intended axis. SETTING: University Eye Clinic and the Department of Industrial and Information Engineering, University of Trieste, Trieste, Italy. DESIGN: Experimental study. METHODS: An experimental optoelectronic test bench was created. It consisted of a high-resolution monitor to project target images and an artificial eye. The system simulates the optical and geometric characteristics of the human eye with an implanted toric IOL. A 3.00 diopters corneal astigmatism was simulated. Images reproduced by the optical system were captured according to different IOL axis positions. The quality of each image was analyzed using the visual information fidelity (VIF) criterion. The VIF reduction was calculated at each IOL rotational step. RESULTS: A 5-degree IOL axis rotation from the intended position determined a decay in the image quality of 7.03%. Ten degrees of IOL rotation caused an 11.09% decay of relative VIF value. For a 30-degree rotation, the VIF decay value was 45.85%. Finally, the image decay with no toric correction was 56.70%. CONCLUSIONS: The more the objective quality of the image decays progressively, the further the axis of the IOL is rotated from its intended position. The reduction in image quality obtained after 30 degrees of toric IOL rotation was less than 50% and after 45 degrees, the image quality was the same as that of no toric correction.


Assuntos
Migração do Implante de Lente Intraocular/fisiopatologia , Astigmatismo/fisiopatologia , Lentes Intraoculares , Modelos Teóricos , Pseudofacia/fisiopatologia , Visão Ocular/fisiologia , Humanos , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA