Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Eur Radiol ; 32(7): 4679-4686, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35137302

RESUMO

OBJECTIVES: To prospectively evaluate the safety and efficacy of embolization using ethylene vinyl alcohol copolymer (Onyx®) and Aetoxysclerol for treatment of pelvic venous disorders (PeVD). METHODS: This prospective study was approved by the institutional ethics review board. Ten clinical parameters were retained for evaluation of PeVD (pelvic pain, dyspareunia, post-coital pain, menstruation pain, lower limbs pain, difficulty walking, aesthetic discomfort, impact on daily working life, psychological impact and impact on daily life), measured on a visual analogue scale (VAS) between 0 and 10, and a global score out of 100 was noted before embolization, after 3 months during the imaging follow-up, and at the end of follow-up by phone call. The main criterion was clinical efficacy of embolization defined by an impairment score < 40/100 and a 50% decrease in overall score. Complications were recorded. Visualization of Onyx® on MRI 3 months after embolization was noted. RESULTS: Between July 2017 and May 2019, 73 consecutive women (mean age ± SD [range]: 41 ± 11 years [25-77]) treated by embolization with Onyx® and Aetoxysclerol were included. The median follow-up was 28 months [Q1-Q3: 24.0-29.2] (range: 18.1-34.5). The median initial VAS impairment score was 39/100 [29.75-48.50] (12-58). Clinical efficacy was obtained for 70 patients (70/73, 95.9%), and the median VAS impairment score at the end of follow-up was significantly lower at 3 [0.00-7.25] (0-73) (p < 0.0001). Four minor complications occurred. Onyx® was visualized on DIXON sequence of MRI for all patients. CONCLUSION: Embolization using Onyx® and Aetoxysclerol for PeVD is safe and effective. KEY POINTS: • Embolization using Onyx® and Aetoxysclerol for pelvic venous disorders is safe and effective. • Imaging follow-up is facilitated by visualization of Onyx® on MRI DIXON sequences.


Assuntos
Embolização Terapêutica , Doenças Vasculares , Dimetil Sulfóxido/uso terapêutico , Embolização Terapêutica/métodos , Feminino , Humanos , Dor/tratamento farmacológico , Polivinil/uso terapêutico , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
2.
Cancer Radiother ; 24(4): 323-331, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32532578

RESUMO

PURPOSE: The purpose of this study was to evaluate MRI and fluorocholine PET/CT diagnostic performances for the detection of local recurrence following prostate brachytherapy for localised prostate cancer. MATERIAL AND METHODS: In this single-centre study, we retrospectively reviewed data from 21 patients treated by brachytherapy for localised prostate cancer and diagnosed with biochemical recurrence according to Phoenix Criteria, who underwent MRI and fluorocholine PET/CT. We included patients with local relapse suspicion according to imaging exams, with biopsy for the final assessment of local recurrence. Patient analysis data were supplemented by segment analysis using an 8-segment model. RESULTS: The fluorocholine PET/CT was positive for 81% and negative for 19% of patients. The sensitivity and specificity were 92% and 33% with diagnosis accuracy of 67%. The MRI was positive for 57% and negative for 43% of patients. The sensitivity and specificity were 67% and 56% with diagnosis accuracy of 62%. There was no statistically significant difference between fluorocholine PET/CT and MRI accuracy (P=0.63). On a segment-based analysis, the sensitivity and specificity were 44% and 82% for fluorocholine PET/CT with diagnosis accuracy of 78%. For MRI, specificity was 91% diagnosis accuracy was 82%. CONCLUSION: Both MRI and fluorocholine PET/CT permit to highlight local recurrence sites after prostate brachytherapy. Confirmation biopsies are, however, necessary since this accuracy is insufficient.


Assuntos
Braquiterapia , Imageamento por Ressonância Magnética/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Idoso , Biópsia , Colina/análogos & derivados , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/patologia , Compostos Radiofarmacêuticos , Dosagem Radioterapêutica , Estudos Retrospectivos , Sensibilidade e Especificidade
4.
Diagn Interv Imaging ; 99(1): 3-8, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29066127

RESUMO

PURPOSE: To compare diameters of in vivo microwave ablation (MWA) performed in swine kidneys with ex vivo diameters, and to correlate with ablation work (AW), a new metric reflecting total energy delivered. MATERIAL AND METHODS: Eighteen in vivo MWA were performed in 6 swine kidneys successively using one or two antennas (MicroThermX®). Ablation consisted in delivering power (45-120W) for 5-15minutes. Ex vivo diameters were provided by the vendors and obtained on bovine liver tissue. AW was defined as the sum of (power)*(time)*(number of antennas) for all phases of an ablation (in kJoules). Kidneys were removed laparoscopically immediately after ablation. After sacrifice, ablations zones were evaluated macroscopically, and maximum diameters of the zones were recorded. Wilcoxon sum rank test and Pearson's correlation were used for comparisons. RESULTS: For a single antenna (n=12), the in vivo diameters ranged from 12 to 35mm, and 15-49mm for 2 antennas (n=6). The in vivo diameters remained shorter than ex vivo diameters by 8.6%±30.1 on 1 antenna and 11.7%±26.5 on 2 antennas (P=0.31 and 0.44, respectively). AW ranged from 13.5 to 108kJ. Diameters increased linearly with AW both with 1 and 2 antennas, but only moderate correlations were observed (r=0.43 [95% confidence interval: -0.19; 0.81], P=0.16; and 0.57 [-0.44; 0.95], P=0.24, respectively). CONCLUSION: Although diameters after in vivo renal MWA increased linearly with AW, the moderate correlation and wide standard deviations observed may justify a careful imaging monitoring during treatment delivery and settings adaptation, if needed, for optimal ablation.


Assuntos
Técnicas de Ablação/instrumentação , Rim/cirurgia , Micro-Ondas , Técnicas de Ablação/métodos , Animais , Bovinos , Rim/patologia , Fígado/cirurgia , Modelos Animais , Nefrectomia , Suínos
6.
Eur Radiol ; 25(1): 24-31, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25117747

RESUMO

PURPOSE: To retrospectively evaluate the ability of magnetic resonance (MR) imaging to differentiate low from high Fuhrman grade renal cell carcinoma (RCC). MATERIALS AND METHODS: MR images from 80 consecutive pathologically proven RCC (57 clear cell, 16 papillary and 7 chromophobe) were evaluated. Double-echo chemical shift, dynamic contrast-enhanced T1- and T2-weighted images and apparent diffusion coefficient (ADC) maps were reviewed independently. Signal intensity index (SII), tumour-to-spleen SI ratio (TSR), ADC ratio, wash-in (WiI) and wash-out indices (WoI) between different phases were calculated and compared to pathological grade and size. The Fuhrman scoring system was used. Low grade (score ≤ 2) and high grade (score ≥ 3) tumours were compared using univariate and multivariate analyses. RESULTS: No associations between grade and imaging factors were found for papillary and chromophobe RCCs. For clear cell RCCs, there was a significant association between the grade and parenchymal WiI (WiI2) (P = 0.02) or ADCr (P = 0.03). A significant association between tumour grade and size (P = 0.01), WiI2 (P = 0.02) and ADCr (P = 0.05) remained in multivariate analysis. CONCLUSIONS: Multiparametric MRI can be used to accurately differentiate low Fuhrman grade clear cell RCC from high grade. High Fuhrman grade (≥ 3) RCCs were larger, had lower parenchymal wash-in indices and lower ADC ratios than low grade. KEY POINTS: • Fuhrman grade of clear cell RCC can be differentiated with multiparametric MR imaging. • Fuhrman grade significantly differed for size, parenchymal wash-in index and ADC ratio. • No significant associations were found for papillary and chromophobe renal cell carcinoma.


Assuntos
Carcinoma de Células Renais/diagnóstico , Neoplasias Renais/diagnóstico , Imageamento por Ressonância Magnética/métodos , Gradação de Tumores/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
7.
Eur Radiol ; 24(5): 1068-80, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24557052

RESUMO

OBJECTIVES: To retrospectively evaluate the ability of multiparametric magnetic resonance (MR) imaging to differentiate renal tumours. METHODS: MR images from 100 consecutive pathologically proven solid renal tumours without macroscopic fat [57 clear cell, 16 papillary and 7 chromophobe renal cell carcinomas (RCCs), 16 oncocytomas and 4 minimal fat angiomyolipomas (AMLs)] between 2009 and 2012 were evaluated. Two radiologists blinded to pathology results independently reviewed double-echo chemical shift, dynamic contrast-enhanced T1- and T2-weighted images and apparent diffusion coefficient (ADC) maps. Signal intensity index (SII), tumour-to-spleen SI ratio (TSR), ADC ratio, wash-in (WiI) and wash-out indices (WoI) between different phases were calculated. RESULTS: There were significant differences between papillary RCCs and other renal tumours for arterial WiI (P < 0.001), initial WoI (P = 0.006) and ADC ratio (P < 0.001); between chromophobe RCCs and oncocytomas for TSR (P = 0.02), parenchymal WiI (P = 0.03), late WiI (P = 0.02), initial WoI (P = 0.03) and late WoI (P = 0.04); and between clear cell RCCs and oncocytomas for SII (P = 0.01) and parenchymal WiI (P = 0.01). Papillary RCCs were distinguished from other tumours (sensitivity 37.5 %, specificity 100 %) and oncocytomas from chromophobe RCCs (sensitivity 25 %, specificity 100 %) and clear cell RCCs (sensitivity 100 %, specificity 94.2 %). CONCLUSION: MR imaging provides criteria able to accurately distinguish papillary RCCs from other tumours and oncocytomas from chromophobe and clear cell RCCs. KEY POINTS: • Multiparametric MR parameters accurately distinguish papillary RCCs with high specificity (100 %). • Oncocytomas can be distinguished from chromophobe RCCs with high specificity (100 %). • Oncocytomas can be distinguished from clear cell RCCs with high specificity (94.2 %). • In oncocytomatosis, imaging follow-up with such parameters analysis could be promoted.


Assuntos
Adenoma Oxífilo/patologia , Carcinoma de Células Renais/patologia , Neoplasias Renais/patologia , Imageamento por Ressonância Magnética/métodos , Adenoma Oxífilo/diagnóstico , Adulto , Idoso de 80 Anos ou mais , Angiomiolipoma/diagnóstico , Angiomiolipoma/patologia , Carcinoma de Células Renais/diagnóstico , Diagnóstico Diferencial , Feminino , Humanos , Neoplasias Renais/classificação , Neoplasias Renais/diagnóstico , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
8.
Cardiovasc Intervent Radiol ; 37(6): 1575-9, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24464261

RESUMO

PURPOSE: The purpose of this preliminary study was to report the short-term local control of percutaneous image-guided cryoablation of localized symptomatic abdominal scar endometrioma. METHODS: Four consecutive patients (mean age 34.5 years) with a total of ten lesions were included, with mean preoperative pain of 7 (range 5-9) on the visual analog scale. Cryoablation was performed in a single session under general anesthesia. RESULTS: Postoperative superficial edema disappeared within 2 weeks for all patients. No severe complications (>grade 2 according to the CTCAE classification) were reported. Mean postoperative pain was 1.7 at 6 months (range 0-5) and magnetic resonance imaging demonstrated a significant volume decrease for all patients (range 72.2-100%; p = 0.028). CONCLUSIONS: Percutaneous cryoablation shows promising local control in patients with symptomatic abdominal wall endometriosis.


Assuntos
Parede Abdominal/cirurgia , Cicatriz/cirurgia , Criocirurgia/métodos , Endometriose/cirurgia , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Medição da Dor , Dor Pós-Operatória , Estudos Prospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA