Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Eur Radiol Exp ; 8(1): 54, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38698099

RESUMO

BACKGROUND: We aimed to improve the image quality (IQ) of sparse-view computed tomography (CT) images using a U-Net for lung metastasis detection and determine the best tradeoff between number of views, IQ, and diagnostic confidence. METHODS: CT images from 41 subjects aged 62.8 ± 10.6 years (mean ± standard deviation, 23 men), 34 with lung metastasis, 7 healthy, were retrospectively selected (2016-2018) and forward projected onto 2,048-view sinograms. Six corresponding sparse-view CT data subsets at varying levels of undersampling were reconstructed from sinograms using filtered backprojection with 16, 32, 64, 128, 256, and 512 views. A dual-frame U-Net was trained and evaluated for each subsampling level on 8,658 images from 22 diseased subjects. A representative image per scan was selected from 19 subjects (12 diseased, 7 healthy) for a single-blinded multireader study. These slices, for all levels of subsampling, with and without U-Net postprocessing, were presented to three readers. IQ and diagnostic confidence were ranked using predefined scales. Subjective nodule segmentation was evaluated using sensitivity and Dice similarity coefficient (DSC); clustered Wilcoxon signed-rank test was used. RESULTS: The 64-projection sparse-view images resulted in 0.89 sensitivity and 0.81 DSC, while their counterparts, postprocessed with the U-Net, had improved metrics (0.94 sensitivity and 0.85 DSC) (p = 0.400). Fewer views led to insufficient IQ for diagnosis. For increased views, no substantial discrepancies were noted between sparse-view and postprocessed images. CONCLUSIONS: Projection views can be reduced from 2,048 to 64 while maintaining IQ and the confidence of the radiologists on a satisfactory level. RELEVANCE STATEMENT: Our reader study demonstrates the benefit of U-Net postprocessing for regular CT screenings of patients with lung metastasis to increase the IQ and diagnostic confidence while reducing the dose. KEY POINTS: • Sparse-projection-view streak artifacts reduce the quality and usability of sparse-view CT images. • U-Net-based postprocessing removes sparse-view artifacts while maintaining diagnostically accurate IQ. • Postprocessed sparse-view CTs drastically increase radiologists' confidence in diagnosing lung metastasis.


Assuntos
Neoplasias Pulmonares , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Feminino , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso
2.
Eur Radiol Exp ; 8(1): 58, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38735899

RESUMO

BACKGROUND: Chondrosarcomas are rare malignant bone tumors diagnosed by analyzing radiological images and histology of tissue biopsies and evaluating features such as matrix calcification, cortical destruction, trabecular penetration, and tumor cell entrapment. METHODS: We retrospectively analyzed 16 cartilaginous tumor tissue samples from three patients (51-, 54-, and 70-year-old) diagnosed with a dedifferentiated chondrosarcoma at the femur, a moderately differentiated chondrosarcoma in the pelvis, and a predominantly moderately differentiated chondrosarcoma at the scapula, respectively. We combined a hematein-based x-ray staining with high-resolution three-dimensional (3D) microscopic x-ray computed tomography (micro-CT) for nondestructive 3D tumor assessment and tumor margin evaluation. RESULTS: We detected trabecular entrapment on 3D micro-CT images and followed bone destruction throughout the volume. In addition to staining cell nuclei, hematein-based staining also improved the visualization of the tumor matrix, allowing for the distinction between the tumor and the bone marrow cavity. The hematein-based staining did not interfere with further conventional histology. There was a 5.97 ± 7.17% difference between the relative tumor area measured using micro-CT and histopathology (p = 0.806) (Pearson correlation coefficient r = 0.92, p = 0.009). Signal intensity in the tumor matrix (4.85 ± 2.94) was significantly higher in the stained samples compared to the unstained counterparts (1.92 ± 0.11, p = 0.002). CONCLUSIONS: Using nondestructive 3D micro-CT, the simultaneous visualization of radiological and histopathological features is feasible. RELEVANCE STATEMENT: 3D micro-CT data supports modern radiological and histopathological investigations of human bone tumor specimens. It has the potential for being an integrative part of clinical preoperative diagnostics. KEY POINTS: • Matrix calcifications are a relevant diagnostic feature of bone tumors. • Micro-CT detects all clinically diagnostic relevant features of x-ray-stained chondrosarcoma. • Micro-CT has the potential to be an integrative part of clinical diagnostics.


Assuntos
Neoplasias Ósseas , Condrossarcoma , Estudos de Viabilidade , Imageamento Tridimensional , Microtomografia por Raio-X , Humanos , Condrossarcoma/diagnóstico por imagem , Condrossarcoma/patologia , Microtomografia por Raio-X/métodos , Idoso , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/patologia , Pessoa de Meia-Idade , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Masculino , Feminino , Coloração e Rotulagem/métodos
3.
Radiologie (Heidelb) ; 63(7): 513-522, 2023 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-37341743

RESUMO

INTRODUCTION: The spatial and contrast resolution of conventional planar or computed tomographic X­ray techniques is not sufficient to investigate microstructures of tissues. Dark-field imaging with X­rays is an emerging technology that recently provided the first clinical results and makes diagnostic use of interactions of the beams with tissue due to their wave character. APPLICATION: Dark-field imaging can provide information about the microscopic structure or porosity of the tissue under investigation that is otherwise inaccessible. This makes it a valuable complement to conventional X­ray imaging, which can only account for attenuation. Our results demonstrate that X­ray dark-field imaging provides pictorial information about the underlying microstructure of the lung in humans. Given the close relationship between alveolar structure and the functional state of the lung, this is of great importance for diagnosis and therapy monitoring and may contribute to a better understanding of lung diseases in the future. In the early detection of chronic obstructive pulmonary disease, which is usually associated with structural impairment of the lung, this novel technique could help to facilitate its diagnosis. PERSPECTIVE: The application of dark-field imaging to computed tomography is still under development because it is technically difficult. Meanwhile, a prototype for experimental application has been developed and is currently being tested on a variety of materials. Use in humans is conceivable especially for tissues whose microstructure favors characteristic interactions due to the wave nature of the X­rays.


Assuntos
Pneumopatias , Tomografia Computadorizada por Raios X , Humanos , Raios X , Radiografia , Tomografia Computadorizada por Raios X/métodos , Pulmão/diagnóstico por imagem , Pneumopatias/diagnóstico por imagem
4.
PLoS One ; 18(4): e0279323, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37058505

RESUMO

BACKGROUND: The differentiation of minimal-fat-or low-fat-angiomyolipomas from other renal lesions is clinically challenging in conventional computed tomography. In this work, we have assessed the potential of grating-based x-ray phase-contrast computed tomography (GBPC-CT) for visualization and quantitative differentiation of minimal-fat angiomyolipomas (mfAMLs) and oncocytomas from renal cell carcinomas (RCCs) on ex vivo renal samples. MATERIALS AND METHODS: Laboratory GBPC-CT was performed at 40 kVp on 28 ex vivo kidney specimens including five angiomyolipomas with three minimal-fat (mfAMLs) and two high-fat (hfAMLs) subtypes as well as three oncocytomas and 20 RCCs with eight clear cell (ccRCCs), seven papillary (pRCCs) and five chromophobe RCC (chrRCC) subtypes. Quantitative values of conventional Hounsfield units (HU) and phase-contrast Hounsfield units (HUp) were determined and histogram analysis was performed on GBPC-CT and grating-based attenuation-contrast computed tomography (GBAC-CT) slices for each specimen. For comparison, the same specimens were imaged at a 3T magnetic resonance imaging (MRI) scanner. RESULTS: We have successfully matched GBPC-CT images with clinical MRI and histology, as GBPC-CT presented with increased soft tissue contrast compared to absorption-based images. GBPC-CT images revealed a qualitative and quantitative difference between mfAML samples (58±4 HUp) and oncocytomas (44±10 HUp, p = 0.057) and RCCs (ccRCCs: 40±12 HUp, p = 0.012; pRCCs: 43±9 HUp, p = 0.017; chrRCCs: 40±7 HUp, p = 0.057) in contrast to corresponding laboratory attenuation-contrast CT and clinical MRI, although not all differences were statistically significant. Due to the heterogeneity and lower signal of oncocytomas, quantitative differentiation of the samples based on HUp or in combination with HUs was not possible. CONCLUSIONS: GBPC-CT allows quantitative differentiation of minimal-fat angiomyolipomas from pRCCs and ccRCCs in contrast to absorption-based imaging and clinical MRI.


Assuntos
Adenoma Oxífilo , Angiomiolipoma , Carcinoma de Células Renais , Neoplasias Renais , Humanos , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Angiomiolipoma/diagnóstico por imagem , Angiomiolipoma/patologia , Raios X , Tomografia Computadorizada por Raios X/métodos , Adenoma Oxífilo/diagnóstico por imagem , Diagnóstico Diferencial , Estudos Retrospectivos
5.
Artigo em Alemão | MEDLINE | ID: mdl-35790166

RESUMO

OBJECTIVE: The aim of this study is to evaluate whether X-ray dark-field (DF) radiography is useful for the diagnosis of gout in birds and reptiles and whether this preclinical model could be helpful to establish this non-invasive imaging method in human medicine. MATERIAL AND METHODS: A total of 18 limbs originating from 11 birds (7 different species) and 7 reptiles (4 different species) with and without suspected joint gout were measured using a grating-based X-ray dark-field setup and conventional X-ray examination, respectively. Each image acquisition generated a dark-field and a conventional absorption x-ray image. The results of the individual scans were compared with the results of a pathological examination and arthrocentesis. RESULTS: In 5 of the birds and 4 of the reptiles examined, gout was detected by pathologic examination. In each group, uric acid crystals were found in the joints of 3 animals by means of arthrocentesis. The uric acid crystals were detectable in 2 bird and 2 reptile limbs in the dark-field image. CONCLUSION: The study demonstrated that the urate crystals evoke a clearly visible dark field signal, whereas this was not the case in the conventional radiographs. CLINICAL RELEVANCE: The results obtained show that uric acid crystal detection using less invasive imaging methods in an animal model with birds and reptiles may expand gout diagnostics not only in veterinary medicine but also in human medicine and possibly replace arthrocentesis if a DF signal is detectable. Preclinical scanners which use X-ray dark-field and phase-contrast radiography already exist for hands and mammography.


Assuntos
Animais Exóticos , Gota , Animais , Gota/diagnóstico por imagem , Gota/veterinária , Radiografia , Ácido Úrico , Raios X
7.
BMC Musculoskelet Disord ; 23(1): 122, 2022 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-35123466

RESUMO

BACKGROUND: To evaluate the diagnostic value of MR-derived CT-like images and simulated radiographs compared with conventional radiographs in patients with suspected shoulder pathology. METHODS: 3 T MRI of the shoulder including a 3D T1-weighted gradient echo sequence was performed in 25 patients (mean age 52.4 ± 18 years, 13 women) with suspected shoulder pathology. Subsequently a cone-beam forward projection algorithm was used to obtain intensity-inverted CT-like images and simulated radiographs. Two radiologists evaluated the simulated images separately and independently using the conventional radiographs as the standard of reference, including measurements of the image quality, acromiohumeral distance, critical shoulder angle, degenerative joint changes and the acromial type. Additionally, the CT-like MR images were evaluated for glenoid defects, subcortical cysts and calcifications. Agreement between the MR-derived simulated radiographs and conventional radiographs was calculated using Cohen's Kappa. RESULTS: Measurements on simulated radiographs and conventional radiographs overall showed a substantial to almost perfect inter- and intra-rater agreement (κ = 0.69-1.00 and κ = 0.65-0.85, respectively). Image quality of the simulated radiographs was rated good to excellent (1.6 ± 0.7 and 1.8 ± 0.6, respectively) by the radiologists. A substantial agreement was found regarding diagnostically relevant features, assessed on Y- and anteroposterior projections (κ = 0.84 and κ = 0.69 for the measurement of the CSA; κ = 0.95 and κ = 0.60 for the measurement of the AHD; κ = 0.77 and κ = 0.77 for grading of the Samilson-Prieto classification; κ = 0.83 and κ = 0.67 for the grading of the Bigliani classification, respectively). CONCLUSION: In this proof-of-concept study, clinically relevant features of the shoulder joint were assessed reliably using MR-derived CT-like images and simulated radiographs with an image quality equivalent to conventional radiographs. MR-derived CT-like images and simulated radiographs may provide useful diagnostic information while reducing the amount of radiation exposure.


Assuntos
Imageamento por Ressonância Magnética , Dor de Ombro , Acrômio , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Radiografia , Reprodutibilidade dos Testes , Dor de Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X
8.
Lancet Digit Health ; 3(11): e733-e744, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34711378

RESUMO

BACKGROUND: Although advanced medical imaging technologies give detailed diagnostic information, a low-dose, fast, and inexpensive option for early detection of respiratory diseases and follow-ups is still lacking. The novel method of x-ray dark-field chest imaging might fill this gap but has not yet been studied in living humans. Enabling the assessment of microstructural changes in lung parenchyma, this technique presents a more sensitive alternative to conventional chest x-rays, and yet requires only a fraction of the dose applied in CT. We studied the application of this technique to assess pulmonary emphysema in patients with chronic obstructive pulmonary disease (COPD). METHODS: In this diagnostic accuracy study, we designed and built a novel dark-field chest x-ray system (Technical University of Munich, Munich, Germany)-which is also capable of simultaneously acquiring a conventional thorax radiograph (7 s, 0·035 mSv effective dose). Patients who had undergone a medically indicated chest CT were recruited from the department of Radiology and Pneumology of our site (Klinikum rechts der Isar, Technical University of Munich, Munich, Germany). Patients with pulmonary pathologies, or conditions other than COPD, that might influence lung parenchyma were excluded. For patients with different disease stages of pulmonary emphysema, x-ray dark-field images and CT images were acquired and visually assessed by five readers. Pulmonary function tests (spirometry and body plethysmography) were performed for every patient and for a subgroup of patients the measurement of diffusion capacity was performed. Individual patient datasets were statistically evaluated using correlation testing, rank-based analysis of variance, and pair-wise post-hoc comparison. FINDINGS: Between October, 2018 and December, 2019 we enrolled 77 patients. Compared with CT-based parameters (quantitative emphysema ρ=-0·27, p=0·089 and visual emphysema ρ=-0·45, p=0·0028), the dark-field signal (ρ=0·62, p<0·0001) yields a stronger correlation with lung diffusion capacity in the evaluated cohort. Emphysema assessment based on dark-field chest x-ray features yields consistent conclusions with findings from visual CT image interpretation and shows improved diagnostic performance than conventional clinical tests characterising emphysema. Pair-wise comparison of corresponding test parameters between adjacent visual emphysema severity groups (CT-based, reference standard) showed higher effect sizes. The mean effect size over the group comparisons (absent-trace, trace-mild, mild-moderate, and moderate-confluent or advanced destructive visual emphysema grades) for the COPD assessment test score is 0·21, for forced expiratory volume in 1 s (FEV1)/functional vital capacity is 0·25, for FEV1% of predicted is 0·23, for residual volume % of predicted is 0·24, for CT emphysema index is 0·35, for dark-field signal homogeneity within lungs is 0·38, for dark-field signal texture within lungs is 0·38, and for dark-field-based emphysema severity is 0·42. INTERPRETATION: X-ray dark-field chest imaging allows the diagnosis of pulmonary emphysema in patients with COPD because this technique provides relevant information representing the structural condition of lung parenchyma. This technique might offer a low radiation dose alternative to CT in COPD and potentially other lung disorders. FUNDING: European Research Council, Deutsche Forschungsgemeinschaft, Royal Philips, and Karlsruhe Nano Micro Facility.


Assuntos
Enfisema/diagnóstico , Pulmão/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Enfisema Pulmonar/diagnóstico , Radiografia Torácica/métodos , Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Enfisema/diagnóstico por imagem , Feminino , Volume Expiratório Forçado , Alemanha , Humanos , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/patologia , Enfisema Pulmonar/diagnóstico por imagem , Radiografia , Índice de Gravidade de Doença , Fumar , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
9.
Radiology ; 301(2): 389-395, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34427464

RESUMO

Background X-ray dark-field radiography takes advantage of the wave properties of x-rays, with a relatively high signal in the lungs due to the many air-tissue interfaces in the alveoli. Purpose To describe the qualitative and quantitative characteristics of x-ray dark-field images in healthy human subjects. Materials and Methods Between October 2018 and January 2020, patients of legal age who underwent chest CT as part of their diagnostic work-up were screened for study participation. Inclusion criteria were a normal chest CT scan, the ability to consent, and the ability to stand upright without help. Exclusion criteria were pregnancy, serious medical conditions, and changes in the lung tissue, such as those due to cancer, pleural effusion, atelectasis, emphysema, infiltrates, ground-glass opacities, or pneumothorax. Images of study participants were obtained by using a clinical x-ray dark-field prototype, recently constructed and commissioned at the authors' institution, to simultaneously acquire both attenuation-based and dark-field thorax radiographs. Each subject's total dark-field signal was correlated with his or her lung volume, and the dark-field coefficient was correlated with age, sex, weight, and height. Results Overall, 40 subjects were included in this study (average age, 62 years ± 13 [standard deviation]; 26 men, 14 women). Normal human lungs have high signal, while the surrounding osseous structures and soft tissue have very low and no signal, respectively. The average dark-field signal was 2.5 m-1 ± 0.4 of examined lung tissue. There was a correlation between the total dark-field signal and the lung volume (r = 0.61, P < .001). No difference was found between men and women (P = .78). Also, age (r = -0.18, P = .26), weight (r = 0.24, P = .13), and height (r = 0.01, P = .96) did not influence dark-field signal. Conclusion This study introduces qualitative and quantitative values for x-ray dark-field imaging in healthy human subjects. The quantitative x-ray dark-field coefficient is independent from demographic subject parameters, emphasizing its potential in diagnostic assessment of the lung. ©RSNA, 2021 See also the editorial by Hatabu and Madore in this issue.


Assuntos
Pulmão/anatomia & histologia , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Estudos de Avaliação como Assunto , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Pesquisa Qualitativa , Valores de Referência
10.
Sci Rep ; 11(1): 15857, 2021 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-34349135

RESUMO

We present a method to generate synthetic thorax radiographs with realistic nodules from CT scans, and a perfect ground truth knowledge. We evaluated the detection performance of nine radiologists and two convolutional neural networks in a reader study. Nodules were artificially inserted into the lung of a CT volume and synthetic radiographs were obtained by forward-projecting the volume. Hence, our framework allowed for a detailed evaluation of CAD systems' and radiologists' performance due to the availability of accurate ground-truth labels for nodules from synthetic data. Radiographs for network training (U-Net and RetinaNet) were generated from 855 CT scans of a public dataset. For the reader study, 201 radiographs were generated from 21 nodule-free CT scans with altering nodule positions, sizes and nodule counts of inserted nodules. Average true positive detections by nine radiologists were 248.8 nodules, 51.7 false positive predicted nodules and 121.2 false negative predicted nodules. The best performing CAD system achieved 268 true positives, 66 false positives and 102 false negatives. Corresponding weighted alternative free response operating characteristic figure-of-merits (wAFROC FOM) for the radiologists range from 0.54 to 0.87 compared to a value of 0.81 (CI 0.75-0.87) for the best performing CNN. The CNN did not perform significantly better against the combined average of the 9 readers (p = 0.49). Paramediastinal nodules accounted for most false positive and false negative detections by readers, which can be explained by the presence of more tissue in this area.


Assuntos
Nódulos Pulmonares Múltiplos/diagnóstico , Redes Neurais de Computação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Radiologistas/estatística & dados numéricos , Nódulo Pulmonar Solitário/diagnóstico , Humanos , Variações Dependentes do Observador , Curva ROC
11.
Diagnostics (Basel) ; 11(6)2021 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-34073416

RESUMO

The aim of this study is to assess whether perifocal bone marrow edema (BME) in patients with osteoid osteoma (OO) can be accurately detected on dual-layer spectral CT (DLCT) with three-material decomposition. To that end, 18 patients with OO (25.33 ± 12.44 years; 7 females) were pairwise-matched with 18 patients (26.72 ± 9.65 years; 9 females) admitted for suspected pathologies other than OO in the same anatomic location but negative imaging findings. All patients were examined with DLCT and MRI. DLCT data was decomposed into hydroxyapatite and water- and fat-equivalent volume fraction maps. Two radiologists assessed DLCT-based volume fraction maps for the presence of perifocal BME, using a Likert scale (1 = no edema; 2 = likely no edema; 3 = likely edema; 4 = edema). Accuracy, sensitivity, and specificity for the detection of BME on DLCT were analyzed using MR findings as standard of reference. For the detection of BME in patients with OO, DLCT showed a sensitivity of 0.92, a specificity of 0.94, and an accuracy of 0.92 for both radiologists. Interreader agreement for the assessment of BME with DLCT was substantial (weighted κ = 0.78; 95% CI, 0.59, 0.94). DLCT with material-specific volume fraction maps allowed accurate detection of BME in patients with OO. This may spare patients additional examinations and facilitate the diagnosis of OO.

12.
Eur Radiol ; 31(2): 1002-1010, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32856165

RESUMO

OBJECTIVES: To assess the clinical utility of dual-energy CT (DE-CT)-derived iodine concentration (IC) and effective Z (Zeff) in addition to conventional CT attenuation (HU) for the discrimination between primary lung cancer (LC) and pulmonary metastases (PM) from different primary malignancies. METHODS: DE-CT scans of 79 patients with LC (3 histopathologic subgroups) and 89 patients with PM (5 histopathologic subgroups) were evaluated. Quantitative IC, Zeff, and conventional HU values were extracted and normalized to the thoracic aorta. Differences between groups were assessed by pairwise Welch's t test. Correlation and linear regression analyses were used to examine the relationship of imaging parameters in LC and PM. Diagnostic accuracy was measured by the area under receiver operator characteristic curve (AUC) and validated based on resampling methods. RESULTS: Significant differences between subgroups of LC and PMs were noted for all imaging parameters, with the highest number of significant pairs for IC. In univariate analysis, only IC was a significant diagnostic feature for discriminating LC from PM (p = 0.03). All quantitative imaging parameters correlated significantly (p < 0.0001, respectively), with the highest correlation between IC and Zeff (r = 0.91), followed by IC and HU (r = 0.76) and Zeff and HU (r = 0.73). Diagnostic models combining IC or Zeff with HU (IC+HU: AUC = 0.73; Zeff+HU: AUC = 0.69; IC+Zeff+HU: AUC = 0.73) were not significantly different and outperformed individual parameters (IC: AUC = 0.57; Zeff: AUC = 0.57; HU: AUC = 0.55) in diagnostic accuracy (p < 0.05, respectively). CONCLUSION: DE-CT-derived IC or Zeff and conventional HU represent complementary imaging parameters, which, if used in combination, may improve the differentiation between LC and PM. KEY POINTS: • Individual quantitative imaging parameters derived from DE-CT (iodine concentration, effective Z) and conventional CT (HU) provide complementary diagnostic information for the differentiation of primary lung cancer and pulmonary metastases. • A combination of conventional HU and DE-CT parameters enhances the diagnostic utility of individual parameters.


Assuntos
Neoplasias Pulmonares , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Biomarcadores , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
13.
Int J Radiat Biol ; 97(2): 256-264, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33211606

RESUMO

PURPOSE: The MSc Radiation Biology course is a highly interdisciplinary degree program placing radiation biology at the interface between biology, medicine, and physics, as well as their associated technologies. The goal was to establish an internationally acknowledged program with diverse and heterogeneous student cohorts, who benefit from each other academically as well as culturally. We have completed a Five-Year evaluation of the program to assess our qualification profile and the further direction we want to take. MATERIALS AND METHODS: We evaluated the student cohort's data from the last 5 years regarding gender, age, and nationality as well as the highest degree before applying and career path after graduation. RESULTS: Data shows a great diversity regarding nationalty as well as undergraduate background. Cohort sizes could be increased and future prospects mainly aimed to a PhD. Measures after regular quality meetings and students' feedback led to improving the curriculum and workload, teacher's training, and changes to examination regulations. CONCLUSIONS: After 5 years, statistics show that our expectations have been met exceedingly. All graduates had excellent career opportunities reflecting the necessity of this MSc and its topics. We are continuously working on improving the program and adapting the curriculum to the requirements in radiation sciences. The future vision includes an expansion of the program as well as undergraduate education opportunities in this field.


Assuntos
Radiobiologia/educação , Adulto , Currículo , Feminino , Humanos , Masculino
14.
Eur Radiol ; 31(5): 3147-3155, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33052464

RESUMO

OBJECTIVES: Osteoporosis remains under-diagnosed, which may be improved by opportunistic bone mineral density (BMD) measurements on CT. However, correcting for the influence of intravenous iodine-based contrast agent is challenging. The purpose of this study was to assess the diagnostic accuracy of iodine-corrected vertebral BMD measurements derived from non-dedicated contrast-enhanced phantomless dual-layer spectral CT (DLCT) examinations. METHODS: Vertebral volumetric DLCT-BMD was measured in native, arterial, and portal-venous scans of 132 patients (63 ± 16 years; 32% women) using virtual monoenergetic images (50 and 200 keV). For comparison, conventional BMD was determined using an asynchronous QCT calibration. Additionally, iodine densities were measured in the abdominal aorta (AA), inferior vena cava, and vena portae (VP) on each CT phase to adjust for iodine-related measurement errors in multivariable linear regressions and a generalized estimated equation, and conversion equations were calculated. RESULTS: BMD values derived from contrast-enhanced phases using conversion equations adjusted for individual vessel iodine concentrations of VP and/or AA showed a high agreement with those from non-enhanced scans in Bland-Altman plots. Mean absolute errors (MAE) of DLCT-BMD were 3.57 mg/ml for the arterial (R2 = 0.989) and 3.69 mg/ml for the portal-venous phase (R2 = 0.987) (conventional BMD: 4.70 [R2 = 0.983] and 5.15 mg/ml [R2 = 0.981]). In the phase-independent analysis, MAE was 4.49 mg/ml for DLCT (R2 = 0.989) (conventional BMD: 4.82 mg/ml [R2 = 0.981]). CONCLUSIONS: Converted BMD derived from contrast-enhanced DLCT examinations and adjusted for individual vessel iodine concentrations showed a high agreement with non-enhanced DLCT-BMD, suggesting that opportunistic BMD measurements are feasible even in non-dedicated contrast-enhanced DLCT examinations. KEY POINTS: • Accurate BMD values can be converted from contrast-enhanced DLCT scans, independent from the used scan phase. • DLCT-BMD measurements from contrast-enhanced scans should be adjusted with iodine concentrations of portal vein and/or abdominal aorta, which significantly improves the goodness-of-fit of conversion models.


Assuntos
Densidade Óssea , Osteoporose , Feminino , Humanos , Masculino , Programas de Rastreamento , Osteoporose/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
15.
Acta Radiol Open ; 9(9): 2058460120945316, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32995044

RESUMO

BACKGROUND: Rectal cancer (RC) is a frequent malignancy for which magnetic resonance imaging (MRI) is the most common and accurate imaging. Iodine concentration (IC) can be quantified with spectral dual-layer computed tomography CT (DL-CT), which could improve imaging of RC, especially for evaluation of response to radiochemotherapy (RCT). PURPOSE: To compare a DL-CT system to MRI as the non-invasive imaging gold standard for imaging of RC to evaluate the possibility of a response evaluation with DL-CT. MATERIAL AND METHODS: Eleven patients who received DL-CT as well as MRI before and after RCT of RC were retrospectively included into this study. For each examination, a region of interest (ROI) was placed within the tumor. For MRI, the mean apparent diffusion coefficient (ADC) was assessed. For DL-CT, IC, z-effective, and Hounsfield Units (HU) were measured. IC, z-effective, and HU were normalized to the aorta. ADC was correlated to absolute and relative normalized IC, z-effective, and HU with Spearman's ρ. Differences before and after treatment were tested with Wilcoxon signed-rank test. RESULTS: HU, IC, and Z-effective values in DL-CT images decreased significantly after RCT (P<0.01 for each comparison). The mean ADC increased significantly after RCT. Spearman's ρ of the absolute IC difference and the absolute ADC (both before and after RCT) is high and significant (ρ = 0.73; P = 0.01), whereas the ρ-value for z-effective (ρ = 0.56) or HU (ρ = 0.45) to ADC was lower and non-significant. CONCLUSION: Response evaluation of RC after RCT could be possible with DL-CT via the measurement of IC.

16.
Eur J Radiol ; 131: 109253, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32937252

RESUMO

PURPOSE: To evaluate imaging characteristics obtained from magnetic resonance imaging (MRI) with metal artifact reduction (MAR) to differentiate between periprosthetic joint infection (PJI), aseptic loosening and cases without these pathologies after total hip arthroplasty (THA). METHODS: Patients with THA (n = 41; mean age 66.4 ±â€¯9.6 years; 25 women) undergoing 1.5 T MRI with high-bandwidth sequences and view angle tilting followed by revision surgery within 3 months were identified retrospectively. Imaging findings at the metal-bone interface, in the surrounding bone, the soft tissues and lymphadenopathy were assessed by three radiologists in a standardized fashion. Based on clinical and intraoperative findings, patients were categorized in groups with PJI (n = 15), aseptic loosening (n = 15) or without these pathologies (n = 11). Imaging findings were assessed in crosstabs, receiver-operating characteristics and classification and regression trees. RESULTS: Findings at the acetabular cup were specific for the presence of either PJI or aseptic loosening (specificity>0.765 for all), while findings at the stem were sensitive (sensitivity>0.824 for all except periostitis). To differentiate PJI versus aseptic loosening, soft tissue edema (sensitivity, 0.867/specificity>0.733), abnormalities at both, acetabular and femoral components (0.667/0.933-1.000) and enlarged lymph nodes (0.800/0.867) were accurate. CONCLUSION: Standardized assessment of MR imaging findings in THA patients facilitated the differentiation of PJI and aseptic loosening. This information can be helpful for therapy planning.


Assuntos
Artroplastia de Quadril , Artefatos , Prótese de Quadril , Imageamento por Ressonância Magnética/métodos , Falha de Prótese , Infecções Relacionadas à Prótese/diagnóstico por imagem , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
17.
Anticancer Res ; 40(10): 5793-5800, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32988907

RESUMO

BACKGROUND/AIM: Myxofibrosarcoma (MFS) is characterized by an infiltrative growth pattern. This study aimed to determine the correlation between overall survival (OS) and morphological features of MFS as well as examine the reproducibility of these findings on preoperative magnetic resonance imaging (MRI). PATIENTS AND METHODS: Fifty-eight MFS patients underwent preoperative MR imaging with the following features analysed: i) tumour size, ii) localization, iii) margins, iv) morphology, v) signal characteristics, vi) contrast enhancement, vii) presence and extent of perilesional oedema, and viii) presence of the tail sign. RESULTS: Only circumscribed perilesional oedema was associated with a significantly better survival compared to diffuse oedema (p=0.010), which was found in the majority of cases. The tail sign was found in less than 50% of the cases. Cohen's kappa coefficients confirmed a relatively high interrater variability. CONCLUSION: Perilesional diffuse oedema on MR imaging of MFS is significantly correlated with a poor overall survival. The interrater variability in interpretation of MR examinations varies from slight to substantial agreement. Preoperative MR imaging with detailed planning of the resection seem to be a logical approach to achieve negative resection margins and recurrence-free survival.


Assuntos
Fibrossarcoma/diagnóstico por imagem , Histiocitoma Fibroso Maligno/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico por imagem , Neoplasias de Tecidos Moles/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Feminino , Fibrossarcoma/fisiopatologia , Histiocitoma Fibroso Maligno/fisiopatologia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/fisiopatologia , Cuidados Pré-Operatórios , Prognóstico , Neoplasias de Tecidos Moles/fisiopatologia
18.
Sci Rep ; 10(1): 12987, 2020 07 31.
Artigo em Inglês | MEDLINE | ID: mdl-32737389

RESUMO

Lung cancer is a major cause of death worldwide. As early detection can improve outcome, regular screening is of great interest, especially for certain risk groups. Besides low-dose computed tomography, chest X-ray is a potential option for screening. Convolutional network (CNN) based computer aided diagnosis systems have proven their ability of identifying nodules in radiographies and thus may assist radiologists in clinical practice. Based on segmented pulmonary nodules, we trained a CNN based one-stage detector (RetinaNet) with 257 annotated radiographs and 154 additional radiographs from a public dataset. We compared the performance of the convolutional network with the performance of two radiologists by conducting a reader study with 75 cases. Furthermore, the potential use for screening on patient level and the impact of foreign bodies with respect to false-positive detections was investigated. For nodule location detection, the architecture achieved a performance of 43 true-positives, 26 false-positives and 22 false-negatives. In comparison, performance of the two readers was 42 ± 2 true-positives, 28 ± 0 false-positives and 23 ± 2 false-negatives. For the screening task, we retrieved a ROC AUC value of 0.87 for the reader study test set. We found the trained RetinaNet architecture to be only slightly prone to foreign bodies in terms of misclassifications: out of 59 additional radiographs containing foreign bodies, false-positives in two radiographs were falsely detected due to foreign bodies.


Assuntos
Corpos Estranhos/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Redes Neurais de Computação , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Reações Falso-Positivas , Humanos
19.
Eur J Radiol ; 129: 109110, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32559592

RESUMO

PURPOSE: To evaluate the diagnostic value of fiber tractography and diffusivity analysis generated from 3D diffusion-weighted (DW) sequences for preoperative assessment of benign peripheral nerve sheath tumors. METHOD: MR imaging at 3 T was performed in 22 patients (mean age 41.9 ±â€¯17.1y, 13 women) with histologically confirmed schwannomas (N = 18) and histologically confirmed neurofibromas (N = 11), including a 3D DW turbo spin echo sequence with fat suppression. Diffusion tensor parameters were computed and fiber tracks were determined. Evaluation was performed by two radiologists and one orthopedic surgeon blinded for final diagnosis. Mean diffusivity was computed to allow further assessment of tumor microstructure. Preoperative fascicle visualization was graded, fascicles were categorized regarding anatomical location and amount of fascicles surrounding the tumor. The agreement of imaging findings with intraoperative findings was assessed. RESULTS: On 78.3 % of the DTI images, the fascicle visualization was rated as good or very good. Tractography differences were observed in schwannomas and neurofibromas, showing schwannomas to be significantly more often located eccentrically to the nerve (94.8 %) than neurofibromas (0 %, P < 0.01). Fascicles were significantly more often continuous (87.5 %) in schwannomas, while in neurofibromas, none of the tracks was graded to be continuous (0 %, P = 0.014). A substantial agreement between fiber tracking and surgical anatomy was found regarding the fascicle courses surrounding the tumor (κ = 0.78). Mean diffusivity of schwannomas (1.5 ±â€¯0.2 × 10-3 mm2/s) was significantly lower than in neurofibromas (1.8 ±â€¯0.2 × 10-3 mm2/s; P < 0.001). The Youden index showed an optimal cutoff at 1.7 × 10-3 mm2/s (sensitivity, 0.91; specificity, 0.78; J = 0.69). CONCLUSIONS: Preoperative diffusion tensor imaging allowed to accurately differentiate between schwannomas and neurofibromas and to describe their location in relation to the nerve fascicles for preoperative planning.


Assuntos
Imagem de Tensor de Difusão/métodos , Neoplasias de Bainha Neural/diagnóstico por imagem , Neurilemoma/diagnóstico por imagem , Neurofibroma/diagnóstico por imagem , Cuidados Pré-Operatórios/métodos , Adulto , Diagnóstico Diferencial , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade
20.
Sci Rep ; 10(1): 9612, 2020 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-32541788

RESUMO

X-ray fluoroscopy is a commonly applied diagnostic tool for morphological and functional evaluation of the intestine in clinical routine. Acquisition of repetitive X-ray images following oral or rectal application of iodine contrast agent visualizes the time dependent distribution of the contrast medium, and helps to detect for example leakages, tumors or functional disorders. However, movements of the intestine and air trapped inside usually prevent temporal subtraction imaging to be applied to fluoroscopy of the gastrointestinal tract. K-edge subtraction (KES) imaging would enable subtraction fluoroscopy because it allows for imaging of moving organs with little artefacts. Although KES imaging is a well established technique at synchrotron sources, this imaging method is not applied in clinical routine as it relies on brilliant synchrotron radiation. Recently emerging compact synchrotron X-ray sources could provide a quasi-monochromatic, high-flux X-ray beam and allow for the application of KES in a laboratory environment. Here, we present a filter-based dynamic KES approach at the Munich Compact Light Source (MuCLS), the first user-dedicated installation of a compact synchrotron X-ray source worldwide. Compared to conventional temporal subtraction X-ray radiography, our approach increases the contrast while reducing the generated image artefacts.


Assuntos
Fluoroscopia/métodos , Intestinos/diagnóstico por imagem , Técnica de Subtração , Síncrotrons , Animais , Artefatos , Meios de Contraste , Humanos , Camundongos , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA