Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Med Phys ; 51(6): 4389-4401, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38703397

RESUMO

BACKGROUND: Biology-guided radiotherapy (BgRT) is a novel radiotherapy delivery technique that utilizes the tumor itself to guide dynamic delivery of treatment dose to the tumor. The RefleXion X1 system is the first radiotherapy system developed to deliver SCINTIX® BgRT. The X1 is characterized by its split arc design, employing two 90-degree positron emission tomography (PET) arcs to guide therapeutic radiation beams in real time, currently cleared by FDA to treat bone and lung tumors. PURPOSE: This study aims to comprehensively evaluate the capabilities of the SCINTIX radiotherapy delivery system by evaluating its sensitivity to changes in PET contrast, its adaptability in the context of patient motion, and its performance across a spectrum of prescription doses. METHODS: A series of experimental scenarios, both static and dynamic, were designed to assess the SCINTIX BgRT system's performance, including an end-to-end test. These experiments involved a range of factors, including changes in PET contrast, motion, and prescription doses. Measurements were performed using a custom-made ArcCHECK insert which included a 2.2 cm spherical target and a c-shape structure that can be filled with a PET tracer with varying concentrations. Sinusoidal and cosine4 motion patterns, simulating patient breathing, was used to test the SCINTIX system's ability to deliver BgRT during motion-induced challenges. Each experiment was evaluated against specific metrics, including Activity Concentration (AC), Normalized Target Signal (NTS), and Biology Tracking Zone (BTZ) bounded dose-volume histogram (bDVH) pass rates. The accuracy of the delivered BgRT doses on ArcCHECK and EBT-XD film were evaluated using gamma 3%/2 mm and 3%/3 mm analysis. RESULTS: In static scenarios, the X1 system consistently demonstrated precision and robustness in SCINTIX dose delivery. The end-to-end delivery to the spherical target yielded good results, with AC and NTS values surpassing the critical thresholds of 5 kBq/mL and 2, respectively. Furthermore, bDVH analysis consistently confirmed 100% pass rates. These results were reaffirmed in scenarios involving changes in PET contrast, emphasizing the system's ability to adapt to varying PET avidities. Gamma analysis with 3%/2 mm (10% dose threshold) criteria consistently achieved pass rates > 91.5% for the static tests. In dynamic SCINTIX delivery scenarios, the X1 system exhibited adaptability under conditions of motion. Sinusoidal and cosine4 motion patterns resulted in 3%/3 mm gamma pass rates > 87%. Moreover, the comparison with gated stereotactic body radiotherapy (SBRT) delivery on a conventional c-arm Linac resulted in 93.9% gamma pass rates and used as comparison to evaluate the interplay effect. The 1 cm step shift tests showed low overall gamma pass rates of 60.3% in ArcCHECK measurements, while the doses in the PTV agreed with the plan with 99.9% for 3%/3 mm measured with film. CONCLUSIONS: The comprehensive evaluation of the X1 radiotherapy delivery system for SCINTIX BgRT demonstrated good agreement for the static tests. The system consistently achieved critical metrics and delivered the BgRT doses per plan. The motion tests demonstrated its ability to co-localize the dose where the PET signal is and deliver acceptable BgRT dose distributions.


Assuntos
Tomografia por Emissão de Pósitrons , Radioterapia Guiada por Imagem , Tomografia por Emissão de Pósitrons/instrumentação , Radioterapia Guiada por Imagem/instrumentação , Radioterapia Guiada por Imagem/métodos , Aceleradores de Partículas , Humanos , Dosagem Radioterapêutica
2.
Radiother Oncol ; 196: 110317, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38679202

RESUMO

BACKGROUND AND PURPOSE: Concerns over chest wall toxicity has led to debates on treating tumors adjacent to the chest wall with single-fraction stereotactic ablative radiotherapy (SABR). We performed a secondary analysis of patients treated on the prospective iSABR trial to determine the incidence and grade of chest wall pain and modeled dose-response to guide radiation planning and estimate risk. MATERIALS AND METHODS: This analysis included 99 tumors in 92 patients that were treated with 25 Gy in one fraction on the iSABR trial which individualized dose by tumor size and location. Toxicity events were prospectively collected and graded based on the CTCAE version 4. Dose-response modeling was performed using a logistic model with maximum likelihood method utilized for parameter fitting. RESULTS: There were 22 grade 1 or higher chest wall pain events, including five grade 2 events and zero grade 3 or higher events. The volume receiving at least 11 Gy (V11Gy) and the minimum dose to the hottest 2 cc (D2cc) were most highly correlated with toxicity. When dichotomized by an estimated incidence of ≥ 20 % toxicity, the D2cc > 17 Gy (36.6 % vs. 3.7 %, p < 0.01) and V11Gy > 28 cc (40.0 % vs. 8.1 %, p < 0.01) constraints were predictive of chest wall pain, including among a subset of patients with tumors abutting or adjacent to the chest wall. CONCLUSION: For small, peripheral tumors, single-fraction SABR is associated with modest rates of low-grade chest wall pain. Proximity to the chest wall may not contraindicate single fractionation when using highly conformal, image-guided techniques with sharp dose gradients.


Assuntos
Dor no Peito , Radiocirurgia , Parede Torácica , Humanos , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Parede Torácica/efeitos da radiação , Feminino , Masculino , Dor no Peito/etiologia , Idoso , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Dosagem Radioterapêutica , Neoplasias Torácicas/radioterapia , Relação Dose-Resposta à Radiação
3.
Adv Radiat Oncol ; 9(1): 101300, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38260216

RESUMO

Purpose: The aim of this study was to present the first-year experience of treating patients using intensity modulated radiation therapy (IMRT) and stereotactic body radiation therapy (SBRT) with a biology-guided radiation therapy machine, the RefleXion X1 system, installed in a clinical setting. Methods and Materials: A total of 78 patients were treated on the X1 system using IMRT and SBRT from May 2021 to May 2022. Clinical and technical data including treatment sites, number of pretreatment kilovoltage computed tomography (kVCT) scans, beam-on time, patient setup time, and imaging time were collected and analyzed. Machine quality assurance (QA) results, machine performance, and user satisfactory survey were also collected and reported. Results: The most commonly treated site was the head and neck (63%), followed by the pelvis (23%), abdomen (8%), and thorax (6%). Except for 5 patients (6%) who received SBRT treatments for bony metastases in the pelvis, all treatments were conventionally fractionated IMRT. The number of kVCT scans per fraction was 1.2 ± 0.5 (mean ± standard deviation). The beam-on time was 9.2 ± 3.5 minutes. The patient setup time and imaging time per kVCT was 4.8 ± 2.6 minutes and 4.6 ± 1.5 minutes, respectively. The daily machine output deviation was 0.4 ± 1.2% from the baseline. The patient QA had a passing rate of 97.4 ± 2.8% at 3%/2 mm gamma criteria. The machine uptime was 92% of the total treatment time. The daily QA and kVCT image quality received the highest level of satisfaction. The treatment workflow for therapists received the lowest level of satisfaction. Conclusions: One year after the installation, 78 patients were successfully treated with the X1 system using IMRT and/or SBRT. With the recent Food and Drug Administration clearance of biology-guided radiation therapy, our department is preparing to treat patients using positron emission tomography-guidance via a new product release, which will address deficiencies in the current image-guided radiation therapy workflow.

4.
Acad Med ; 99(5): 482-486, 2024 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-38166320

RESUMO

ABSTRACT: With recent advances in understanding racial, socioeconomic, and mental health issues in medicine and their relation to policy and legislation, medical professionals are increasingly involved in local and national advocacy efforts. At the frontlines of these initiatives are medical students who, in addition to completing required coursework and clinical training, devote themselves to serving patients through civic participation. The burgeoning evidence concerning health care disparities and inequity, along with greater awareness of racial and socioeconomic discrimination, have made advocacy an essential aspect of many students' medical training. Every year, thousands of medical students join national medical advocacy organizations, in addition to regional, state, and local groups. Despite the rich history of medical student involvement in advocacy, there remains much speculation and skepticism about the practice as an essential component of the medical profession. From early initiatives pushing for national health insurance after World War II to encouraging antidiscrimination policies and practices, medical students have been collectively working to create change for themselves and their patients. Through efforts such as banning smoking on airplanes, creating safe syringe programs, and protesting against police brutality, many medical students work tirelessly in advocacy despite minimal educational support or guidance about the advocacy process. Given that medical student advocacy continues to grow and has shown measurable successes in the past, the authors believe that these efforts should be rewarded and expanded upon. The authors examine historical examples of medical student advocacy to suggest ways in which advocacy can be integrated into core medical school curricula and activities. They call attention to opportunities to support students' development of knowledge and skills to facilitate legislative change, expansion of interprofessional collaborations and credit, and curricular updates to promote social and health equity.


Assuntos
Currículo , Educação Médica , Defesa do Paciente , Humanos , Currículo/tendências , Defesa do Paciente/educação , Defesa do Paciente/tendências , Educação Médica/tendências , Estados Unidos , Estudantes de Medicina/psicologia , Educação de Graduação em Medicina/tendências , Disparidades em Assistência à Saúde
5.
Clin Lung Cancer ; 25(2): 186-189, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38040540

RESUMO

INTRODUCTION: Prior attempts to escalate radiation dose for non-small cell lung cancer (NSCLC) have not improved survival. Given the high risk for cardiopulmonary toxicity with treatment and heterogenous presentation of locally advanced NSCLC, it is unlikely that a single dose regimen is optimal for all patients. This phase I/II trial aims to evaluate a novel treatment approach where the level of accelerated hypofractionation is determined by the predicted toxicity from dose to organs at risk (OARs). METHODS: Patients ≥ 18 years old with lung cancer planned for fractionated radiotherapy to the lung with concurrent chemotherapy will be eligible. Radiation therapy (RT) will be delivered to a total dose of 60 to 66 Gy in 30, 25, or 20 fractions depending on the ability to meet constraints to key organs at risk including the lungs, heart, and esophagus. The primary endpoint is high grade pulmonary, esophageal, or cardiac toxicity. A Bayesian optimized design is used to determine stopping boundaries and evaluate the primary endpoint. CONCLUSION: PACER will evaluate the safety and feasibility of personalized accelerated chemoradiotherapy for lung cancer.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Adolescente , Neoplasias Pulmonares/tratamento farmacológico , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Teorema de Bayes , Quimiorradioterapia/métodos , Pulmão , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Ensaios Clínicos Fase II como Assunto , Ensaios Clínicos Fase I como Assunto
6.
Int J Radiat Oncol Biol Phys ; 118(5): 1172-1180, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38147912

RESUMO

PURPOSE: Positron emission tomography (PET)-guided radiation therapy is a novel tracked dose delivery modality that uses real-time PET to guide radiation therapy beamlets. The BIOGUIDE-X study was performed with sequential cohorts of participants to (1) identify the fluorodeoxyglucose (FDG) dose for PET-guided therapy and (2) confirm that the emulated dose distribution was consistent with a physician-approved radiation therapy plan. METHODS AND MATERIALS: This prospective study included participants with at least 1 FDG-avid targetable primary or metastatic tumor (2-5 cm) in the lung or bone. For cohort I, a modified 3 + 3 design was used to determine the FDG dose that would result in adequate signal for PET-guided therapy. For cohort II, PET imaging data were collected on the X1 system before the first and last fractions among patients undergoing conventional stereotactic body radiation therapy. PET-guided therapy dose distributions were modeled on the patient's computed tomography anatomy using the collected PET data at each fraction as input to an "emulated delivery" and compared with the physician-approved plan. RESULTS: Cohort I demonstrated adequate FDG activity in 6 of 6 evaluable participants (100.0%) with the first injected dose level of 15 mCi FDG. In cohort II, 4 patients with lung tumors and 5 with bone tumors were enrolled, and evaluable emulated delivery data points were collected for 17 treatment fractions. Sixteen of the 17 emulated deliveries resulted in dose distributions that were accurate with respect to the approved PET-guided therapy plan. The 17th data point was just below the 95% threshold for accuracy (dose-volume histogram score = 94.6%). All emulated fluences were physically deliverable. No toxicities were attributed to multiple FDG administrations. CONCLUSIONS: PET-guided therapy is a novel radiation therapy modality in which a radiolabeled tumor can act as its own fiducial for radiation therapy targeting. Emulated therapy dose distributions calculated from continuously acquired real-time PET data were accurate and machine-deliverable in tumors that were 2 to 5 cm in size with adequate FDG signal characteristics.


Assuntos
Fluordesoxiglucose F18 , Neoplasias Pulmonares , Humanos , Estudos Prospectivos , Tomografia por Emissão de Pósitrons , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patologia , Tomografia Computadorizada por Raios X/métodos , Compostos Radiofarmacêuticos
7.
Adv Radiat Oncol ; 8(5): 101186, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37035034

RESUMO

Purpose: The aim of this study was to apply the Six Sigma methodology and failure mode and effect analysis (FMEA) to mitigate errors in intensity modulated radiation therapy (IMRT) and stereotactic body radiation therapy (SBRT) treatment planning with the first clinical installation of RefleXion X1. Methods and Materials: The Six Sigma approach consisted of 5 phases: define, measure, analyze, improve, and control. The define, measure, and analyze phases consisted of process mapping and an FMEA of IMRT and SBRT treatment planning on the X1. The multidisciplinary team outlined the workflow process and identified and ranked the failure modes associated with the plan check items using the American Association of Physicists in Medicine Task Group 100 recommendations. Items with the highest average risk priority numbers (RPNs) and severity ≥7 were prioritized for automation using the Eclipse Scripting Application Programming Interface (ESAPI). The "improve" phase consisted of developing ESAPI scripts before the clinical launch of X1 to improve efficiency and safety. In the "control" phase, the FMEA ranking was re-evaluated 1 year after clinical launch. Results: Overall, 100 plan check items were identified in which the RPN values ranged from 10.2 to 429.0. Fifty of these items (50%) were suitable for automation within ESAPI. Of the 10 highest-risk items, 8 were suitable for automation. Based on the results of the FMEA, 2 scripts were developed: Planning Assistant, used by the planner during preparation for planning, and Automated Plan Check, used by the planner and the plan checker during plan preparation for treatment. After 12 months of clinical use of the X1 and developed scripts, only 3 errors were reported. The average prescript RPN was 138.0, compared with the average postscript RPN of 47.8 (P < .05), signifying a safer process. Conclusions: Implementing new technology in the clinic can be an error-prone process in which the likelihood of errors increases with increasing pressure to implement the technology quickly. To limit errors in clinical implementation of the novel RefleXion X1 system, the Six Sigma method was used to identify failure modes, establish quality control checks, and re-evaluate these checks 1 year after clinical implementation.

8.
Front Endocrinol (Lausanne) ; 13: 993228, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36387875

RESUMO

The hypothalamic gonadotropin-releasing hormone (GnRH)-kisspeptin neuronal network regulates fertility in all mammals. Pituitary adenylate cyclase-activating polypeptide (PACAP) is a neuropeptide isolated from the hypothalamus that is involved in the regulation of several releasing hormones and trop hormones. It is well-known that PACAP influences fertility at central and peripheral levels. However, the effects of PACAP on GnRH and kisspeptin neurons are not well understood. The present study investigated the integrity of the estrous cycle in PACAP-knockout (KO) mice. The number and immunoreactivity of GnRH (GnRH-ir) neurons in wild-type (WT) and PACAP KO female mice were determined using immunohistochemistry. In addition, the number of kisspeptin neurons was measured by counting kisspeptin mRNA-positive cells in the rostral periventricular region of the third ventricle (RP3V) and arcuate nucleus (ARC) using the RNAscope technique. Finally, the mRNA and protein expression of estrogen receptor alpha (ERα) was also examined. Our data showed that the number of complete cycles decreased, and the length of each cycle was longer in PACAP KO mice. Furthermore, the PACAP KO mice experienced longer periods of diestrus and spent significantly less time in estrus. There was no difference in GnRH-ir or number of GnRH neurons. In contrast, the number of kisspeptin neurons was decreased in the ARC, but not in the R3PV, in PACAP KO mice compared to WT littermates. Furthermore, ERα mRNA and protein expression was decreased in the ARC, whereas in the R3PV region, ERα mRNA levels were elevated. Our results demonstrate that embryonic deletion of PACAP significantly changes the structure and presumably the function of the GnRH-kisspeptin neuronal network, influencing fertility.


Assuntos
Hormônio Liberador de Gonadotropina , Kisspeptinas , Animais , Feminino , Camundongos , Receptor alfa de Estrogênio/metabolismo , Hormônio Liberador de Gonadotropina/genética , Hormônio Liberador de Gonadotropina/metabolismo , Kisspeptinas/genética , Kisspeptinas/metabolismo , Camundongos Knockout , Neurônios/metabolismo , Polipeptídeo Hipofisário Ativador de Adenilato Ciclase/genética , RNA Mensageiro/metabolismo
9.
Technol Cancer Res Treat ; 21: 15330338221100231, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35579876

RESUMO

Purpose: The first clinical biology-guided radiation therapy (BgRT) system-RefleXionTM X1-was installed and commissioned for clinical use at our institution. This study aimed at evaluating the treatment plan quality and delivery efficiency for IMRT/SBRT cases without PET guidance. Methods: A total of 42 patient plans across 6 cancer sites (conventionally fractionated lung, head, and neck, anus, prostate, brain, and lung SBRT) planned with the EclipseTM treatment planning system (TPS) and treated with either a TrueBeam® or Trilogy® were selected for this retrospective study. For each Eclipse VMAT plan, 2 corresponding plans were generated on the X1 TPS with 10 mm jaws (X1-10mm) and 20 mm jaws (X1-20mm) using our institutional planning constraints. All clinically relevant metrics in this study, including PTV D95%, PTV D2%, Conformity Index (CI), R50, organs-at-risk (OAR) constraints, and beam-on time were analyzed and compared between 126 VMAT and RefleXion plans using paired t-tests. Results: All but 3 planning metrics were either equivalent or superior for the X1-10mm plans as compared to the Eclipse VMAT plans across all planning sites investigated. The Eclipse VMAT and X1-10mm plans generally achieved superior plan quality and sharper dose fall-off superior/inferior to targets as compared to the X1-20mm plans, however, the X1-20mm plans were still considered acceptable for treatment. On average, the required beam-on time increased by a factor of 1.6 across all sites for X1-10mm compared to X1-20mm plans. Conclusions: Clinically acceptable IMRT/SBRT treatment plans were generated with the X1 TPS for both the 10 mm and 20 mm jaw settings.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Biologia , Humanos , Masculino , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
10.
Geroscience ; 44(2): 785-803, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35220508

RESUMO

The neuroprotective effects of pituitary adenylate cyclase-activating polypeptide (PACAP) have been shown in numerous in vitro and in vivo models of Parkinson's disease (PD) supporting the theory that PACAP could have an important role in the pathomechanism of the disorder affecting mostly older patients. Earlier studies found changes in PACAP levels in neurological disorders; therefore, the aim of our study was to examine PACAP in plasma samples of PD patients. Peptide levels were measured with ELISA and correlated with clinical parameters, age, stage of the disorder based on the Hoehn and Yahr (HY) scale, subtype of the disease, treatment, and specific scores measuring motor and non-motor symptoms, such as movement disorder society-unified Parkinson's disease rating scale (MDS-UPDRS), Epworth sleepiness scale (ESS), Parkinson's disease sleep scale (PDSS-2), and Beck depression inventory (BDI). Our results showed significantly decreased PACAP levels in PD patients without deep brain stimulation (DBS) therapy and in akinetic-rigid subtype; additionally we also observed a further decrease in the HY stage 3 and 4. Elevated PACAP levels were found in patients with DBS. There were no significant correlations between PACAP level with MDS-UPDRS, type of pharmacological treatment, PDSS-2 sleepiness, or depression (BDI) scales, but we found increased PACAP level in patients with more severe sleepiness problems based on the ESS scale. Based on these results, we suggest that following the alterations of PACAP with other frequently used clinical biomarkers in PD patients might improve strategic planning of further therapeutic interventions and help to provide a clearer prognosis regarding the future perspective of the disease.


Assuntos
Doença de Parkinson , Humanos , Polipeptídeo Hipofisário Ativador de Adenilato Ciclase , Sonolência
11.
Peptides ; 146: 170645, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34478801

RESUMO

In polytrauma patients who survive the primary insult, the imbalance between the pro- and anti-inflammatory processes seems to be responsible for life-threatening complications such as sepsis or multiple organ dysfunction syndrome. Measurement of C-reactive protein (CRP) and procalcitonin (PCT) is a standard way for differentiating between infectious (bacterial) and non-infectious inflammation. Monitoring of immune cell functions, like leukocyte anti-sedimentation rate (LAR) can also be useful to diagnose infectious complications. Pituitary adenylate cyclase activating polypeptide (PACAP) is a neuropeptide with well-known immunomodulatory and anti-inflammatory effects. The aim of our study was to determine the changes of PACAP38 levels in polytrauma patients in the early post-traumatic period in intensive care unit and analyse possible correlation of its level with conventional (CRP, PCT) and unconventional (LAR) laboratory parameters. Twenty polytrauma patients were enrolled. Blood samples were taken daily for five days. We observed significant correlation between PACAP38 and CRP levels on day 4 and 5 as well as between PACAP38 and LAR levels all of the days. This could be due to the anti-inflammatory and cytoprotective functions of PACAP38 as part of an endogenous response to the trauma induced systemic inflammatory response syndrome. These significant correlations could have clinical importance in monitoring the dynamic balance of pro- and anti-inflammatory processes in case of polytraumatic patients.


Assuntos
Traumatismo Múltiplo/sangue , Polipeptídeo Hipofisário Ativador de Adenilato Ciclase/sangue , Adolescente , Adulto , Idoso , Biomarcadores/sangue , Proteína C-Reativa/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pró-Calcitonina/sangue , Síndrome de Resposta Inflamatória Sistêmica/imunologia
12.
Int J Radiat Oncol Biol Phys ; 110(2): 264-266, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33989569
13.
J Appl Clin Med Phys ; 20(8): 56-64, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31423729

RESUMO

PURPOSE: To develop and implement an automated plan check (APC) tool using a Six Sigma methodology with the aim of improving safety and efficiency in external beam radiotherapy. METHODS: The Six Sigma define-measure-analyze-improve-control (DMAIC) framework was used by measuring defects stemming from treatment planning that were reported to the departmental incidence learning system (ILS). The common error pathways observed in the reported data were combined with our departmental physics plan check list, and AAPM TG-275 identified items. Prioritized by risk priority number (RPN) and severity values, the check items were added to the APC tool developed using Varian Eclipse Scripting Application Programming Interface (ESAPI). At 9 months post-APC implementation, the tool encompassed 89 check items, and its effectiveness was evaluated by comparing RPN values and rates of reported errors. To test the efficiency gains, physics plan check time and reported error rate were prospectively compared for 20 treatment plans. RESULTS: The APC tool was successfully implemented for external beam plan checking. FMEA RPN ranking re-evaluation at 9 months post-APC demonstrated a statistically significant average decrease in RPN values from 129.2 to 83.7 (P < .05). After the introduction of APC, the average frequency of reported treatment-planning errors was reduced from 16.1% to 4.1%. For high-severity errors, the reduction was 82.7% for prescription/plan mismatches and 84.4% for incorrect shift note. The process shifted from 4σ to 5σ quality for isocenter-shift errors. The efficiency study showed a statistically significant decrease in plan check time (10.1 ± 7.3 min, P = .005) and decrease in errors propagating to physics plan check (80%). CONCLUSIONS: Incorporation of APC tool has significantly reduced the error rate. The DMAIC framework can provide an iterative and robust workflow to improve the efficiency and quality of treatment planning procedure enabling a safer radiotherapy process.


Assuntos
Automação , Neoplasias/radioterapia , Garantia da Qualidade dos Cuidados de Saúde/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Software , Lista de Checagem , Humanos , Órgãos em Risco/efeitos da radiação , Estudos Prospectivos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Gestão da Qualidade Total
14.
BJU Int ; 120(5): 623-630, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28188682

RESUMO

OBJECTIVE: To assess the feasibility and safety of stereotactic ablative body radiotherapy (SABR) for renal cell carcinoma (RCC) in patients unsuitable for surgery. Secondary objectives were to assess oncological and functional outcomes. MATERIALS AND METHODS: This was a prospective interventional clinical trial with institutional ethics board approval. Inoperable patients were enrolled, after multidisciplinary consensus, for intervention with informed consent. Tumour response was defined using Response Evaluation Criteria In Solid Tumors v1.1. Toxicities were recorded using Common Terminology Criteria for Adverse Events v4.0. Time-to-event outcomes were described using the Kaplan-Meier method, and associations of baseline variables with tumour shrinkage was assessed using linear regression. Patients received either single fraction of 26 Gy or three fractions of 14 Gy, dependent on tumour size. RESULTS: Of 37 patients (median age 78 years), 62% had T1b, 35% had T1a and 3% had T2a disease. One patient presented with bilateral primaries. Histology was confirmed in 92%. In total, 33 patients and 34 kidneys received all prescribed SABR fractions (89% feasibility). The median follow-up was 24 months. Treatment-related grade 1-2 toxicities occurred in 26 patients (78%) and grade 3 toxicity in one patient (3%). No grade 4-5 toxicities were recorded and six patients (18%) reported no toxicity. Freedom from local progression, distant progression and overall survival rates at 2 years were 100%, 89% and 92%, respectively. The mean baseline glomerular filtration rate was 55 mL/min, which decreased to 44 mL/min at 1 and 2 years (P < 0.001). Neutrophil:lymphocyte ratio correlated to % change in tumour size at 1 year, r2 = 0.45 (P < 0.001). CONCLUSION: The study results show that SABR for primary RCC was feasible and well tolerated. We observed encouraging cancer control, functional preservation and early survival outcomes in an inoperable cohort. Baseline neutrophil:lymphocyte ratio may be predictive of immune-mediated response and warrants further investigation.


Assuntos
Neoplasias Renais/radioterapia , Radiocirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Neoplasias Renais/epidemiologia , Neoplasias Renais/mortalidade , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiocirurgia/efeitos adversos , Radiocirurgia/estatística & dados numéricos
15.
BMC Cancer ; 16: 183, 2016 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-26944262

RESUMO

BACKGROUND: Stereotactic ablative body radiotherapy (SABR) is emerging as a non-invasive method for precision irradiation of lung tumours. However, the ideal dose/fractionation schedule is not yet known. The primary purpose of this study is to assess safety and efficacy profile of single and multi-fraction SABR in the context of pulmonary oligometastases. METHODS/DESIGN: The TROG 13.01/ALTG 13.001 clinical trial is a multicentre unblinded randomised phase II study. Eligible patients have up to three metastases to the lung from any non-haematological malignancy, each < 5 cm in size, non-central targets, and have all primary and extrathoracic disease controlled with local therapies. Patients are randomised 1:1 to a single fraction of 28Gy versus 48Gy in four fractions of SABR. The primary objective is to assess the safety of each treatment arm, with secondary objectives including assessment of quality of life, local efficacy, resource use and costs, overall and disease free survival and time to distant failure. Outcomes will be stratified by number of metastases and origin of the primary disease (colorectal versus non-colorectal primary). Planned substudies include an assessment of the impact of online e-Learning platforms for lung SABR and assessment of the effect of SABR fractionation on the immune responses. A total of 84 patients are required to complete the study. DISCUSSION: Fractionation schedules have not yet been investigated in a randomised fashion in the setting of oligometastatic disease. Assuming the likelihood of similar clinical efficacy in both arms, the present study design allows for exploration of the hypothesis that cost implications of managing potentially increased toxicities from single fraction SABR will be outweighed by costs associated with delivering multiple-fraction SABR. TRIALS REGISTRATION: ACTRN12613001157763 , registered 17th October 2013.


Assuntos
Fracionamento da Dose de Radiação , Neoplasias Pulmonares/secundário , Neoplasias Pulmonares/terapia , Radiocirurgia , Radioterapia/métodos , Custos de Cuidados de Saúde , Recursos em Saúde , Humanos , Neoplasias Pulmonares/diagnóstico , Qualidade de Vida , Radiocirurgia/economia , Radiocirurgia/métodos , Radioterapia/economia , Tomografia Computadorizada por Raios X , Carga Tumoral
16.
Radiother Oncol ; 118(3): 540-6, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26873790

RESUMO

BACKGROUND AND PURPOSE: To evaluate renal dysfunction after stereotactic ablative body radiotherapy (SABR) for inoperable primary renal cell carcinoma (RCC) using nuclear medicine assessments. MATERIALS AND METHODS: In a prospective clinical trial, patients received single fraction renal SABR (26 Gy) for tumours <5 cm, or fractionated SABR (3 × 14 Gy) for tumours ⩾5 cm. Global and regional glomerular filtration rate (GFR) was calculated through (51)Cr-EDTA and (99m)Tc-DMSA SPECT/CT, respectively, at baseline and post-treatment (14, 90 days and at 1-year). Regional loss in function was correlated to the absolute and biologically effective doses (BED) delivered. RESULTS: In 21 patients the mean (range) tumour size was 48 mm (21-75 mm). The mean ± SD GFR at baseline was 52 ± 24 ml/min. Net change in mean GFR was +0.6 ± 11.3, +3.2 ± 14.5 and -8.7 ± 13.4 ml/min (p=0.03) at 2 weeks, 3 months and 1 year, respectively. For every 10 Gy of physical dose delivered, an exponential decline in affected kidney GFR was observed at 39% for 26 Gy/1 fraction and 25% for 42 Gy/3 fractions. When normalised to BED3Gy, the dose-response relationship for each treatment prescription was similar with a plateau beyond 100 Gy. The R50% conformity index correlated with GFR loss (p=0.04). No patient required dialysis. CONCLUSIONS: SABR results in clinically acceptable and dose-dependent renal dysfunction at 1-year. Sparing functional kidney from high-dose regions (>50% isodoses) may help reduce risk of functional loss.


Assuntos
Carcinoma de Células Renais/cirurgia , Neoplasias Renais/cirurgia , Rim/fisiopatologia , Rim/efeitos da radiação , Radiocirurgia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Renais/fisiopatologia , Feminino , Taxa de Filtração Glomerular/efeitos da radiação , Humanos , Rim/cirurgia , Neoplasias Renais/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiocirurgia/efeitos adversos , Tomografia Computadorizada de Emissão de Fóton Único
17.
Technol Cancer Res Treat ; 15(3): 428-36, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-25994795

RESUMO

Intrafraction organ deformation may be accounted for by inclusion of temporal information in dose calculation models. In this article, we demonstrate a quasi-4-dimensional method for improved risk estimation. Conventional 3-dimensional and quasi-4-dimensional calculations employing dose warping for dose accumulation were undertaken for patients with liver metastases planned for 42 Gy in 6 fractions of stereotactic body radiotherapy. Normal tissue complication probabilities and stochastic risks for radiation-induced carcinogenesis and cardiac complications were evaluated for healthy peripheral structures. Hypothetical assessments of other commonly employed dose/fractionation schedules on normal tissue complication probability estimates were explored. Conventional 3-dimensional dose computation may result in significant under- or overestimation of doses to organ at risk. For instance, doses differ (on average) by 17% (σ = 14%) for the left kidney, by 14% (σ = 7%) for the right kidney, by 7% (σ = 9%) for the large bowel, and by 10% (σ = 14%) for the duodenum. Discrepancies in the excess relative risk range up to about 30%. The 3-dimensional approach was shown to result in cardiac complication risks underestimated by >20%. For liver stereotactic body radiotherapy, we have shown that conventional 3-dimensional dose calculation may significantly over-/underestimate dose to organ at risk (90%-120% of the 4-dimensional estimate for the mean dose and 20%-150% for D2%). Providing dose estimates that most closely represent the actual dose delivered will provide valuable information to improve our understanding of the dose response for partial volume irradiation using hypofractionated schedules. Excess relative risks of radiocarcinogenesis were shown to range up to approximately excess relative risk = 4 and the prediction thereof depends greatly on the use of either 3-dimensional or 4-dimensional methods (with corresponding results differing by tens of percent).


Assuntos
Algoritmos , Neoplasias Hepáticas/radioterapia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Doses de Radiação , Dosagem Radioterapêutica
18.
Pract Radiat Oncol ; 5(6): e597-605, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26547828

RESUMO

PURPOSE: Stereotactic ablative body radiation therapy for primary kidney cancer treatment relies on motion management that can quantify both the trajectory of kidney motion and stabilize the patient. A prospective ethics-approved clinical trial of stereotactic treatment to primary kidney targets was conducted at our institution. Our aim was to report on specific kidney tumor motion and the inter- and intrafraction motion as seen on treatment. METHODS AND MATERIALS: Patients with tumor size <5 cm received a dose of 26 Gy in 1 fraction and those with tumor size ≥5 cm received 42 Gy in 3 fractions. All patients underwent a 4-dimensional computed tomography planning scan, immobilized in a dual-vacuum system. A conventional linear accelerator cone beam computed tomography scan was used for pre-, mid-, and posttreatment imaging to verify target position. RESULTS: Between July 2012 and October 2014, 33 targets from 32 consecutive patients (24 males/8 females) were treated. Seventeen targets were prescribed 26 Gy/1 fraction and the remaining 16 targets received 42 Gy/3 fractions. Kidney motion at each of the poles was not affected by the presence of tumor (P = .875), nor was the motion statistically different from the corresponding contralateral kidney pole (P = .909). The mean 3-dimensional displacement of the target at mid- and posttreatment was 1.3 mm (standard deviation ± 1.6) and 1.0 mm (standard deviation ± 1.3), respectively. The maximum displacement in any direction for 95% of the fractions at mid- and posttreatment was ≤3 mm. CONCLUSION: In summary, stereotactic ablative body radiation therapy of primary kidney targets can be accurately delivered on a conventional linear accelerator with protocol that has minimal intrafractional target motion.


Assuntos
Neoplasias Renais/cirurgia , Movimento , Radiocirurgia , Técnicas de Imagem de Sincronização Respiratória/métodos , Cirurgia Assistida por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Tomografia Computadorizada de Feixe Cônico , Fracionamento da Dose de Radiação , Feminino , Tomografia Computadorizada Quadridimensional , Humanos , Neoplasias Renais/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Órgãos em Risco , Aceleradores de Partículas , Estudos Prospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada , Carga Tumoral
19.
Radiother Oncol ; 115(2): 157-62, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25935743

RESUMO

BACKGROUND AND PURPOSE: To assess the utility of functional lung avoidance using IMRT informed by four-dimensional (4D) ventilation/perfusion (V/Q) PET/CT. MATERIALS AND METHODS: In a prospective clinical trial, patients with non-small cell lung cancer (NSCLC) underwent 4D-V/Q PET/CT scanning before 60Gy of definitive chemoradiation. Both "highly perfused" (HPLung) and "highly ventilated" (HVLung) lung volumes were delineated using a 70th centile SUV threshold, and a "ventilated lung volume" (VLung) was created using a 50th centile SUV threshold. For each patient four IMRT plans were created, optimised to the anatomical lung, HPLung, HVLung and VLung volumes, respectively. Improvements in functional dose volumetrics when optimising to functional volumes were assessed using mean lung dose (MLD), V5, V10, V20, V30, V40, V50 and V60 parameters. RESULTS: The study cohort consisted of 20 patients with 80 IMRT plans. Plans optimised to HPLung resulted in a significant reduction of functional MLD by a mean of 13.0% (1.7Gy), p=0.02. Functional V5, V10 and V20 were improved by 13.2%, 7.3% and 3.8% respectively (p-values<0.04). There was no significant sparing of dose to functional lung when adapting to VLung or HVLung. Plan quality was highly consistent with a mean PTV D95 and D5 ranging from 60.8Gy to 61.0Gy and 63.4Gy to 64.5Gy, respectively, and mean conformity and heterogeneity index ranging from 1.11 to 1.17 and 0.94 to 0.95, respectively. CONCLUSION: IMRT plans adapted to perfused but not ventilated lung on 4D-V/Q PET/CT allowed for reduced dose to functional lung whilst maintaining consistent plan quality.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Tomografia Computadorizada Quadridimensional , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
20.
Int J Radiat Oncol Biol Phys ; 92(2): 446-52, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-25847606

RESUMO

OBJECTIVE: To develop a mathematical tool that can update a patient's planning target volume (PTV) partway through a course of radiation therapy to more precisely target the tumor for the remainder of treatment and reduce dose to surrounding healthy tissue. METHODS AND MATERIALS: Daily on-board imaging was used to collect large datasets of displacements for patients undergoing external beam radiation therapy for solid tumors. Bayesian statistical modeling of these geometric uncertainties was used to optimally trade off between displacement data collected from previously treated patients and the progressively accumulating data from a patient currently partway through treatment, to optimally predict future displacements for that patient. These predictions were used to update the PTV position and margin width for the remainder of treatment, such that the clinical target volume (CTV) was more precisely targeted. RESULTS: Software simulation of dose to CTV and normal tissue for 2 real prostate displacement datasets consisting of 146 and 290 patients treated with a minimum of 30 fractions each showed that re-evaluating the PTV position and margin width after 8 treatment fractions reduced healthy tissue dose by 19% and 17%, respectively, while maintaining CTV dose. CONCLUSION: Incorporating patient-specific displacement patterns from early in a course of treatment allows PTV adaptation for the remainder of treatment. This substantially reduces the dose to healthy tissues and thus can reduce radiation therapy-induced toxicities, improving patient outcomes.


Assuntos
Modelos Teóricos , Tratamentos com Preservação do Órgão/métodos , Órgãos em Risco/efeitos da radiação , Neoplasias da Próstata/radioterapia , Lesões por Radiação/prevenção & controle , Planejamento da Radioterapia Assistida por Computador/métodos , Pontos de Referência Anatômicos , Teorema de Bayes , Marcadores Fiduciais , Humanos , Masculino , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica , Software , Carga Tumoral , Incerteza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA