Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
J Neurosurg Spine ; : 1-12, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38759242

RESUMO

OBJECTIVE: Tranexamic acid (TXA) is an FDA-approved antifibrinolytic that is seeing increased popularity in spine surgery owing to its ability to reduce intraoperative blood loss (IOBL) and allogeneic transfusion requirements. The present study aimed to summarize the current literature on these formulations in the context of short-segment instrumented lumbar fusion including ≥ 1-level posterior lumbar interbody fusion (PLIF). METHODS: The PubMed, Cochrane, and Web of Science databases were queried for all full-text English studies evaluating the use of topical TXA (tTXA), systemic TXA (sTXA), or combined tTXA+sTXA in patients undergoing PLIF. The primary endpoints of interest were operative time, IOBL, and total blood loss (TBL); secondary endpoints included venous thromboembolic complication occurrence, and allogeneic and autologous transfusion requirements. Outcomes were compared using random effects. Comparisons were made between the following treatment groups: sTXA, tTXA, and sTXA+tTXA. Given that sTXA is arguably the standard of care in the literature (i.e., the most common route of administration that to this point has been studied the most), the authors compared sTXA versus tTXA and sTXA versus sTXA+tTXA. Study heterogeneity was assessed with the I2 test, and grouped analysis using the Hedge's g test was performed for measurement of effect size. RESULTS: Forty-five articles were identified, of which 17 met the criteria for inclusion with an aggregate of 1008 patients. TXA regimens included sTXA only, tTXA only, and various combinations of sTXA and tTXA. There were no significant differences in operative time, TBL, or postoperative drainage between the sTXA and tTXA groups or between the sTXA and sTXA+tTXA groups. CONCLUSIONS: The present meta-analysis suggested clinical equipoise between isolated sTXA, isolated tTXA, and combinatorial tTXA+sTXA formulations as hemostatic adjuvants/neoadjuvants in short-segment fusion including ≥ 1-level PLIF. Given the theoretically lower venous thromboembolism risk associated with tTXA, additional investigations using large cohorts comparing these two formulations within the posterior fusion population are merited. Although TXA has been shown to be effective, there are insufficient data to support topical or systemic administration as superior within the open PLIF population.

2.
J Clin Med ; 13(7)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38610594

RESUMO

(1) Background: The correction of adult spinal deformity (ASD) can require long, complex constructs with multiple rods which traverse important biomechanical levels to achieve multi-pelvic fixation. Minimally invasive (MIS) placement of these constructs has historically been difficult. Advanced technologies such as spinal robotics platforms can facilitate the design and placement of these constructs and further enable these surgical approaches in MIS deformity surgery. (2) Methods: A retrospective study was performed on a series of ASD patients undergoing MIS deformity correction with ≥eight fusion levels to the lower thoracic spine with preoperative robotic construct planning and robot-assisted pedicle screw placement. (3) Results: There were 12 patients (10 female, mean age 68.6 years) with a diagnosis of either degenerative scoliosis (8 patients) or sagittal imbalance (4 patients). All underwent preoperative robotic planning to assist in MIS robot-assisted percutaneous or transfascial placement of pedicle and iliac screws with multiple-rod constructs. Mean operative values per patient were 9.9 levels instrumented (range 8-11), 3.9 interbody cages (range 2-6), 3.3 iliac fixation points (range 2-4), 3.3 rods (range 2-4), 18.7 screws (range 13-24), estimated blood loss 254 cc (range 150-350 cc), and operative time 347 min (range 242-442 min). All patients showed improvement in radiographic sagittal, and, if applicable, coronal parameters. Mean length of stay was 5.8 days with no ICU admissions. Ten patients ambulated on POD 1 or 2. Of 224 screws placed minimally invasively, four breaches were identified on intraoperative CT and repositioned (three lateral, one medial) for a robot-assisted screw accuracy of 98.2%. (4) Conclusions: Minimally invasive long-segment fixation for adult spinal deformity surgery has historically been considered laborious and technically intensive. Preoperative robotics planning facilitates the design and placement of even complex multi-rod multi-pelvic fixation for MIS deformity surgery.

3.
World Neurosurg X ; 22: 100282, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38444873

RESUMO

Background/objective: The recent development of minimally invasive surgical techniques (MIS) has made possible the correction of adult spinal deformity (ASD) with less blood loss and shorter hospital stays. However, minimally invasive placement of pedicle screws at the proximal level of the construct can increase pseudarthrosis risk, leading to implant failure, kyphosis, and reoperations. We aggregate existing literature to describe pseudarthrosis rates at the proximal thoracic or thoracolumbar junction in MIS and subsequent reoperation rates. Methods: After a three-tied search strategy in PubMed, we identified 9 articles for study inclusion, describing outcomes from MIS correction of ASD, pseudarthrosis as complication, and surgery on 4+ levels. Baseline patient characteristics and combined rates of pseudarthrosis and reoperation were calculated. Results: A total of 482 patients were studied with an average [range] age of 65.5 [60.4,72], 6.3 [4.4,11] levels fused per patient, follow-up time of 28.3 [12,39] months, and 64.8% females. Pseudarthrosis was reported in 28 of 482 pooled patients (5.8%) of which 15 of 374 pooled patients (4.0%) ultimately underwent a reoperation for pseudarthrosis. Post-operative characteristics included an estimated blood loss (EBL) of 527.1 [241,1466] mL, operating time of 297.9 [183,475] minutes, and length of stay of 7.7 [5,10] days. Among the papers comparing MIS to open surgery, all reported a significantly lower EBL in patients treated with MIS. Conclusion: This analysis demonstrate a measurable pseudarthrosis risk when using MIS to treat ASD, overwhelming requiring reoperation. The benefits of MIS must be considered against the drawbacks of pseudarthrosis when determining ASD management.

4.
World Neurosurg ; 2024 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-38350597

RESUMO

BACKGROUND: Lumbosacral transitional vertebrae (LSTV) are congenital anomalies of the L5-S1 segments characterized by either sacralization of the most caudal lumbar vertebra or lumbarization of the most cephalad sacral vertebra. This variation in anatomy exposes patients to additional surgical risks. METHODS: In order to shed light on surgical considerations reported for lumbar spine cases involving LSTV as described in the extant literature, we performed a systematic review in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. We also present a case example in which wrong level surgery was avoided due to anatomical understanding of LSTV. RESULTS: A 48-year-old female presented with severe back pain after sustaining a fall from ten feet. The patient exhibited full motor function in all extremities but had begun to experience urinary retention. On initial imaging read, the patient was suspected to have an L1 burst fracture. A review of the imaging demonstrated a transitional vertebra. Therefore, based on the last rib corresponding to T12, the fractured level was L2. This case illustrates the risk LSTV carries for wrong site surgery; appropriate levels were then decompressed and instrumented. On systematic review of the literature according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines, a three database literature search identified 39 studies describing 885 patients with LSTV and relevant surgical considerations. The primary indications for surgery were for disc herniation (37%), Bertolotti's syndrome (35%), and spinal stenosis (25%). This cohort displayed a mean follow-up time of 23 months. Reherniation occurred in 12 patients (5.5%). Medical management through steroid injection was 24, 72% (n = 80) for the sample. Wrong level surgery occurred in 1.4% (n = 12) of patients. CONCLUSIONS: LSTV represents a constellation of changes in anatomy beyond just a sacralized or lumbarized vertebra. These anatomical differences expose the patient to additional surgical risks. This case and review of the literature highlight avoidable complications and in particular wrong level surgery.

5.
Asian Spine J ; 18(1): 118-123, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38379151

RESUMO

Single-position lateral interbody fusion surgery has gained traction over the years because of reduced surgical time and improved operating theater workflow. With the introduction of robotics in spine surgery, surgeons can place pedicle screws with a high degree of accuracy and efficiency; moreover, the robot allows us to localize the disk space and perform endplate preparation accurately with minimal radiation. In this study, we discuss the potential synergistic benefits of integrating robotic-assisted spine surgery and singleposition prone lateral surgery. We share our technique and provide the operative nuances of using the Mazor X Stealth Edition system (Medtronic, Minneapolis, MN, USA). We highlighted the potential synergistic benefits of integrating both the prone lateral and robotic-assisted surgical techniques, including the challenges encountered. This approach is not meant to replace other techniques or be used in all patients. Instead, it adds to our arsenal for managing spine fusion.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38329333

RESUMO

We present here a 58-year-old female patient with L4-5 spondylolisthesis, who underwent a minimally invasive L4-5 oblique lumbar interbody fusion (OLIF) with robot-assisted bilateral posterior instrumented fixation in a single lateral position (Mazor X Stealth Edition, Medtronic). There has been interest in detailed video-based descriptions of single-position surgery with lateral approach interbody fusions, either in the prone or lateral decubitus position.1-6 Particularly, the addition of robotics has been shown to help increase overall operating efficiency in the lateral position with reduced case times even with the increased up-front robot setup time.7,8 The OLIF, also known as an anterior-to-psoas approach, allows for single-position posterior fixation and can be very effective at L4-5 where the anatomy of the iliac crest or lumbar plexus does not preclude this surgical corridor the way it could in the transpsoas lateral lumbar interbody fusion. Clinical outcomes between these 2 lateral approaches have been shown to be very good,9 and OLIF has reduced blood loss while still restoring alignment parameters compared with anterior lumbar interbody fusion, with better fusion and reduced subsidence compared with transforaminal lumbar interbody fusion.10,11 To our knowledge, this is the first video demonstrating a view of the OLIF approach through a high-definition retractor-based camera (MaxView Camera, Viseon Inc). There is no identifying patient information in this video. The participants and any identifiable individuals consented to publication of his/her image, and the patient consented to the procedure.

7.
Neurospine ; 21(1): 20-29, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38317548

RESUMO

Spinal robotics have the potential to improve the consistency of outcomes in adult spinal deformity (ASD) surgery. The objective of this paper is to assess the accuracy of pedicle and S2 alar-iliac (S2AI) screws placed with robotic guidance in ASD patients. PubMed Central, Google Scholar, and an institutional library database were queried until May 2023. Articles were included if they described ASD correction via robotic guidance and pedicle and/or S2AI screw accuracy. Articles were excluded if they described pediatric/adolescent spinal deformity or included outcomes for both ASD and non-ASD patients without separating the data. Methodological quality was assessed using the Newcastle-Ottawa scale. Primary endpoints were pedicle screw accuracy based on the Gertzbein-Robbins Scale and self-reported accuracy percentages for S2AI screws. Data were extracted for patient demographics, operative details, and perioperative outcomes and assessed using descriptive statistics. Five studies comprising 138 patients were included (mean age 66.0 years; 85 females). A total of 1,508 screws were inserted using robotic assistance (51 S2AI screws). Two studies assessing pedicle screws reported clinically acceptable trajectory rates of 98.7% and 96.0%, respectively. Another study reported a pedicle screw accuracy rate of 95.5%. Three studies reported 100% accuracy across 51 total S2AI screws. Eight total complications and 4 reoperations were reported. Current evidence supports the application of robotics in ASD surgery as safe and effective for placement of both screw types. However, due to the paucity of data, a comprehensive assessment of its incremental benefit over other techniques cannot be made. Further work using expanded cohorts is merited.

8.
Spine Deform ; 12(3): 577-585, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38265734

RESUMO

PURPOSE: The purpose of this review was to evaluate the effectiveness of patient-specific rods for adult spinal deformity. METHODS: A systematic review of the literature was performed through an electronic search of the PubMed, Scopus, and Web of Science databases. Human studies between 2012 and 2023 were included. Sample size, sagittal vertical axis (SVA), pelvic incidence-lumbar lordosis (PI-LL), pelvic tilt (PT), operation time, blood loss, follow-up duration, and complications were recorded for each study when available. RESULTS: Seven studies with a total of 304 adult spinal deformity patients of various etiologies were included. All studies reported SVA, and PT; two studies did not report PI-LL. Four studies reported planned radiographic outcomes. Two found a significant association between preoperative plan and postoperative outcome in all three outcomes. One found a significant association for PI-LL alone. The fourth found no significant associations. SVA improved in six of seven studies, PI-LL improved in all five, and three of seven studies found improved postoperative PT. Significance of these results varied greatly by study. CONCLUSION: Preliminary evidence suggests potential benefits of PSRs in achieving optimal spino-pelvic parameters in ASD surgery. Nevertheless, conclusions regarding the superiority of PSRs over traditional rods must be judiciously drawn, given the heterogeneity of patients and study methodologies, potential confounding variables, and the absence of robust randomized controlled trials. Future investigations should concentrate on enhancing preoperative planning, standardizing surgical methodologies, isolating specific patient subgroups, and head-to-head comparisons with traditional rods to fully elucidate the impact of PSRs in ASD surgery.


Assuntos
Lordose , Humanos , Adulto , Lordose/diagnóstico por imagem , Lordose/cirurgia , Resultado do Tratamento , Curvaturas da Coluna Vertebral/cirurgia , Curvaturas da Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia , Coluna Vertebral/diagnóstico por imagem , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação
9.
Asian Spine J ; 17(6): 1139-1154, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38105638

RESUMO

Laparoscopic anterior lumbar interbody fusion (L-ALIF), which employs laparoscopic cameras to facilitate a less invasive approach, originally gained traction during the 1990s but has subsequently fallen out of favor. As the envelope for endoscopic approaches continues to be pushed, a recurrence of interest in laparoscopic and/or endoscopic anterior approaches seems possible. Therefore, evaluating the current evidence base in regard to this approach is of much clinical relevance. To this end, a systematic literature search was performed according to PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines using the following keywords: "(laparoscopic OR endoscopic) AND (anterior AND lumbar)." Out of the 441 articles retrieved, 22 were selected for quantitative analysis. The primary outcome of interest was the radiographic fusion rate. The secondary outcome was the incidence of perioperative complications. Meta-analysis was performed using RStudio's "metafor" package. Of the 1,079 included patients (mean age, 41.8±2.9 years), 481 were males (44.6%). The most common indication for L-ALIF surgery was degenerative disk disease (reported by 18 studies, 81.8%). The mean follow-up duration was 18.8±11.2 months (range, 6-43 months). The pooled fusion rate was 78.9% (95% confidence interval [CI], 68.9-90.4). Complications occurred in 19.2% (95% CI, 13.4-27.4) of L-ALIF cases. Additionally, 7.2% (95% CI, 4.6-11.4) of patients required conversion from L-ALIF to open surgery. Although L-ALIF does not appear to be supported by studies available in the literature, it is important to consider the context from which these results have been obtained. Even if these results are taken at face value, the failure of endoscopy to have a role in the ALIF approach does not mean that it should not be incorporated in posterior approaches.

10.
J Neurosurg Case Lessons ; 6(25)2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38109726

RESUMO

BACKGROUND: Lumbosacral transitional vertebrae (LSTVs) are congenital anomalies that occur in the spinal segments of L5-S1. These vertebrae result from sacralization of the lowermost lumbar segment or lumbarization of the uppermost sacral segment. When the lowest lumbar vertebra fuses or forms a false joint with the sacrum (pseudoarticulation), it can cause pain and manifest clinically as Bertolotti syndrome. OBSERVATIONS: A 36-year-old female presented with severe right-sided low-back pain. Computed tomography was unremarkable except for a right-sided Castellvi type IIA LSTV. The pain proved refractory to physical therapy and lumbar epidural spinal injections, but targeted steroid and bupivacaine injection of the pseudoarticulation led to 2 weeks of complete pain relief. She subsequently underwent minimally invasive resection of the pseudoarticulation, with immediate improvement in her low-back pain. The patient continued to be pain free at the 3-year follow-up. LESSONS: LSTVs alter the biomechanics of the lumbosacral spine, which can lead to medically refractory mechanical pain requiring surgical intervention. Select patients with Bertolotti syndrome can benefit from operative management, including resection, fusion, or decompression of the pathologic joint.

11.
N Am Spine Soc J ; 15: 100234, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37564913

RESUMO

Background: Robotic assistance has been shown to increase instrumentation placement accuracy in open and minimally invasive spinal fusion. These gains have been achieved without increases in operative times, blood loss, or hospitalization duration. However, most work has been done in the degenerative population and little is known of the utility of robotic assistance when applied to spinal trauma. This is largely due to the uncertainty stemming from the disruption of normal anatomy by the traumatic injury. Since the robot depends upon registration for instrumentation guidance according to the fiducials it uses, trauma can introduce unique challenges. The present study sought to evaluate the safety and efficacy of robotic assistance in a consecutive cohort of spine trauma patients. Methods: All patients with Thoracolumbar Injury Classification and Severity Scale (TLICS) >4 who underwent robot-assisted spinal fusion using the Globus ExcelsiusGPS at a single tertiary care center for trauma between 2020 and 2022 were identified. Demographic, clinical, and surgical data were collected and analyzed; the primary endpoints were operative time, fluoroscopy time, estimated blood loss, postoperative complications, admission time, and 90-day readmission rate. The paired t-test was used to compare differences between mean values when looking at the number of surgical levels. Results: Forty-two patients undergoing robot-assisted spinal surgery were included (mean age 61.3±17.1 year; 47% female. Patients were stratified by the number of operative levels, 2 (n = 10), 3-4 (n = 11), 5 to 6 (n = 13), or >6 (n = 8). There appeared to be a positive correlation between number of levels instrumented and odds of postoperative complications, admission duration, fluoroscopy time, and estimated blood loss. There were no instances of screw malposition or breach. Conclusions: This initial experience suggests robotic assistance can be safely employed in the spine trauma population. Additional experiences in larger patient populations are necessary to delineate those traumatic pathologies most amenable to robotic assistance.

12.
Neurospine ; 20(2): 451-463, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37401063

RESUMO

Interbody fusion is a workhorse technique in lumbar spine surgery that facilities indirect decompression, sagittal plane realignment, and successful bony fusion. The 2 most commonly employed cage materials are titanium (Ti) alloy and polyetheretherketone (PEEK). While Ti alloy implants have superior osteoinductive properties they more poorly match the biomechanical properties of cancellous bones. Newly developed 3-dimensional (3D)-printed porous titanium (3D-pTi) address this disadvantage and are proposed as a new standard for lumbar interbody fusion (LIF) devices. In the present study, the literature directly comparing 3D-pTi and PEEK interbody devices is systematically reviewed with a focus on fusion outcomes and subsidence rates reported in the in vitro, animal, and human literature. A systematic review directly comparing outcomes of PEEK and 3D-pTi interbody spinal cages was performed. PubMed, Embase, and Cochrane Library databases were searched according to PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) guidelines. Mean Newcastle-Ottawa Scale score for cohort studies was 6.4. A total of 7 eligible studies were included, comprising a combination of clinical series, ovine animal data, and in vitro biomechanical studies. There was a total population of 299 human and 59 ovine subjects, with 134 human (44.8%) and 38 (64.4%) ovine models implanted with 3D-pTi cages. Of the 7 studies, 6 reported overall outcomes in favor of 3D-pTi compared to PEEK, including subsidence and osseointegration, while 1 study reported neutral outcomes for device related revision and reoperation rate. Though limited data are available, the current literature supports 3D-pTi interbodies as offering superior fusion outcomes relative to PEEK interbodies for LIF without increasing subsidence or reoperation risk. Histologic evidence suggests 3D-Ti to have superior osteoinductive properties that may underlie these superior outcomes, but additional clinical investigation is merited.

13.
World Neurosurg ; 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37393993

RESUMO

BACKGROUND: Since its proposal, the Global Alignment and Proportion (GAP) score has been the topic of several external validation studies, which have yielded conflicting results. Given the lack of consensus regarding this prognostic tool, the authors aim to assess the accuracy of GAP scores for predicting mechanical complications following adult spinal deformity correction surgery. METHODS: A systematic search was performed using PubMed, Embase, and Cochrane Library for the purpose of identifying all studies evaluating the GAP score as a predictive tool for mechanical complications. GAP scores were pooled using a random-effects model to compare patients reporting mechanical complications after surgery versus those reporting no complications. Where receiver operator curves were provided, the area under the curve (AUC) was pooled. RESULTS: A total of 15 studies featuring 2092 patients were selected for inclusion. Qualitative analysis using Newcastle-Ottawa criteria revealed moderate quality among all included studies (5.99/9). With respect to sex, the cohort was predominantly female (82%). The pooled mean age among all patients in the cohort was 58.55 years, with a mean follow-up of 33.86 months after surgery. Upon pooled analysis, we found that mechanical complications were associated with higher mean GAP scores, albeit minimal (mean difference = 0.571 [ 95% confidence interval: 0.163-0.979]; P = 0.006, n = 864). Additionally, age (P = 0.136, n = 202), fusion levels (P = 0.207, n = 358), and body mass index (P = 0.616, n = 350) were unassociated with mechanical complications. Pooled AUC revealed poor discrimination overall (AUC = 0.69; n = 1206). CONCLUSIONS: GAP scores may have a minimal-to-moderate predictive capability for mechanical complications associated with adult spinal deformity correction.

14.
J Neurosurg Spine ; 39(4): 490-497, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37486864

RESUMO

OBJECTIVE: Lateral lumbar interbody fusion including anterior-to-psoas oblique lumbar interbody fusion has conventionally relied on pedicle screw placement (PSP) for construct stabilization. Single-position surgery with lumbar interbody fusion in the lateral decubitus position with concomitant PSP has been associated with increased operative efficiency. What remains unclear is the accuracy of PSP with robotic guidance when compared with the more familiar prone patient positioning. The present study aimed to compare robot-assisted screw placement accuracy between patients with instrumentation placed in the prone and lateral positions. METHODS: The authors identified all consecutive patients treated with interbody fusion and PSP in the prone or lateral position by a single surgeon between January 2019 and October 2022. All pedicle screws placed were analyzed using CT scans to determine appropriate positioning according to the Gertzbein-Robbins classification grading system (grade C or worse was considered as a radiographically significant breach). Multivariate logistic regression models were constructed to identify risk factors for the occurrence of a radiographically significant breach. RESULTS: Eighty-nine consecutive patients (690 screws) were included, of whom 46 (477 screws) were treated in the prone position and 43 (213 screws) in the lateral decubitus position. There were fewer breaches in the prone (n = 13, 2.7%) than the lateral decubitus (n = 15, 7.0%) group (p = 0.012). Nine (1.9%) radiographically significant breaches occurred in the prone group compared with 10 (4.7%) in the lateral decubitus group (p = 0.019), for a prone versus lateral decubitus PSP accuracy rate of 98.1% versus 95.3%. There were no significant differences in BMI between prone versus lateral decubitus cohorts (30.1 vs 29.6) or patients with screw breach versus those without (31.2 vs 29.5). In multivariate models, the prone position was the only significant protective factor for screw accuracy; no other significant risk factors for screw breach were identified. CONCLUSIONS: The present data suggest that pedicle screws placed with robotic assistance have higher placement accuracy in the prone position. Further studies will be needed to validate the accuracy of PSP in the lateral position as single-position surgery becomes more commonplace in the treatment of spinal disorders.


Assuntos
Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos , Robótica , Fusão Vertebral , Cirurgiões , Humanos , Estudos Retrospectivos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Tomografia Computadorizada por Raios X
15.
Eur Spine J ; 2023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-37452837

RESUMO

PURPOSE: Minimally invasive single position lateral ALIF at L5-S1 with simultaneous robot-assisted posterior fixation has technical and anatomic considerations that need further description. METHODS: This is a retrospective case series of single position lateral ALIF at L5-S1 with robotic assisted fixation. End points included radiographic parameters, lordosis distribution index (LDI), complications, pedicle screw accuracy, and inpatient metrics. RESULTS: There were 17 patients with mean age of 60.5 years. Eight patients underwent interbody fusion at L5-S1, five patients at L4-S1, two patients at L3-S1, and one patient at L2-S1 in single lateral position. Operative times for 1-level and 2-level cases were 193 min and 278 min, respectively. Mean EBL was 71 cc. Mean improvements in L5-S1 segmental lordosis were 11.7 ± 4.0°, L1-S1 lordosis of 4.8 ± 6.4°, sagittal vertical axis of - 0.1 ± 1.7 cm°, pelvic tilt of - 3.1 ± 5.9°, and pelvic incidence lumbar-lordosis mismatch of - 4.6 ± 6.4°. Six patients corrected into a normal LDI (50-80%) and no patients became imbalanced over a mean follow-up period of 14.4 months. Of 100 screws placed in lateral position with robotic assistance, there were three total breaches (two lateral grade 3, one medial grade 2) for a screw accuracy of 97.0%. There were no neurologic, vascular, bowel, or ureteral injuries, and no implant failure or reoperation. CONCLUSION: Single position lateral ALIF at L5-S1 with simultaneous robotic placement of pedicle screws by a second surgeon is a safe and effective technique that improves global alignment and lordosis distribution index.

16.
Eur Spine J ; 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37389697

RESUMO

OBJECTIVES: Single position lateral fusion with robotic assistance eliminates the need for surgical staging while harnessing the precision of robotic adjuncts. We expand on this technique by demonstrating the technical feasibility of placing bilateral pedicle screws with S2-alar-iliac (S2AI) fixation while in the lateral position. METHODS: A cadaveric study was performed using 12 human specimens. A retrospective clinical series was also performed for patients who had undergone robot-assisted placement of S2AI screws in lateral decubitus between June 2020 and June 2022. Case demographics, implant placement time, implant size, screw accuracy, and complications were recorded. Early postoperative radiographic outcomes were reported. RESULTS: In the cadaveric series, a total of 126 screws were placed with robotic assistance in 12 cadavers of which 24 screws were S2AI. There were four breaches from pedicle screws and none with S2AI screws for an overall accuracy rate of 96.8%. In the clinical series, four patients (all male, mean age 65.8 years) underwent single position lateral surgery with S2AI distal fixation. Mean BMI was 33.6 and mean follow-up was 20.5 months. Mean radiographic improvements were lumbar lordosis 12.3 ± 4.7°, sagittal vertical axis 1.5 ± 2.1 cm, pelvic tilt 8.5 ± 10.0°, and pelvic incidence-lumbar lordosis mismatch 12.3 ± 4.7°. A total of 42 screws were placed of which eight screws were S2AI. There were two breaches from pedicle screws and none from S2AI screws for an overall accuracy rate of 95.2%. No repositioning or salvage techniques were required for the S2AI screws. CONCLUSIONS: We demonstrate here the technical feasibility of single position robot-assisted placement of S2-alar-iliac screws in the lateral decubitus position for single position surgery.

17.
J Neurosurg Spine ; 39(4): 443-451, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37382304

RESUMO

OBJECTIVE: While single-position surgery (SPS) eliminates the need for patient repositioning, the placement of screws in the unconventional lateral position poses unique challenges related to asymmetry relative to the surgical table. Use of robotic guidance or intraoperative navigation can help to overcome this. The aim of this study was to compare the relative accuracies offered by these various navigation modalities for pedicle screws placed in lateral SPS. METHODS: According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, the PubMed/Medline, Embase, and Cochrane Library databases were queried for studies reporting pedicle screw placement accuracy using fluoroscopic, CT-navigated, O-arm, or robotic guidance in lateral SPS, and a systematic review and meta-analysis was performed. Included studies all compared evaluated screw placement accuracy in lateral SPS using a single navigation method. Quality assessment was performed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system; risk of bias was assessed using the Newcastle-Ottawa Scale and the Joanna Briggs Institute checklist. The primary outcome, rate of pedicle screw breach, was analyzed using random-effects meta-analysis. RESULTS: Eleven studies were included comprising 548 patients who underwent the placement of instrumentation with 2488 screws. For the fluoroscopic, CT-navigated, O-arm, and robotic guidance cohorts, there were 3, 2, 3, and 3 studies, respectively. Breach rates by modality were as follows: fluoroscopic guidance (6.6%), CT navigation (4.7%), O-arm (3.9%), and robotic guidance (3.9%). Random-effects meta-analysis showed a significant difference between studies, with an overall breach rate of 4.9% (95% CI 3.1%-7.5%; p < 0.001); however, testing for subgroup differences failed to show a significant difference between guidance modalities (QM = 0.69, df = 3; p = 0.88). Heterogeneity between studies was significant (I2 = 79.0%, τ2 = 0.41, χ2 = 47.65, df = 10; p < 0.001). CONCLUSIONS: Robotic guidance of screws is noninferior to alternative guidance modalities in lateral SPS; however, additional prospective studies directly comparing different guidance types are merited.


Assuntos
Parafusos Pediculares , Robótica , Fusão Vertebral , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Estudos Prospectivos , Fusão Vertebral/métodos , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Vértebras Lombares/cirurgia
18.
World Neurosurg ; 2023 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-37141940

RESUMO

OBJECTIVE: Currently, tranexamic acid (TXA) is the most widely used antifibrinolytic agent in spine surgery and has been proven to reduce perioperative blood loss. However, the safety of high-dose regimens remains in established. METHODS: A retrospective chart review was performed to identify all adult patients who underwent spine surgery with high-dose TXA (50 mg/kg loading dose, mg/kg/h maintenance dose) between September 2019 and March 2020. RESULTS: Thirty-six patients were treated with intraoperative high-dose TXA during the study period. The mean age was 56.6 (range: 22-82). Average body mass index was 27.2 (5.1) kg/m2. Average preoperative Charlson Comorbidity Index was 3.0 (2.7). The mean number of spinal levels operated on was 6.9 (4.3). Seven cases (19.4%) were revision surgeries. The mean intraoperative blood loss was 587.1 (900.0) mL, and total blood loss was 623.8 (991.9) mL. Postoperatively, time to ambulation was on average 1.7 (1.7) days. The mean total length of stay was 9.8 days (7.9, range 2-41). The most common indication for surgery was tumor (n = 9, 25%), followed by fracture (n = 8, 22.2%), deformity (n = 7, 19.4%), pseudarthrosis (n = 6, 16.7%), and symptomatic lumbar disc herniation (n = 2, 5.6%). There were no thromboembolic or other significant complications among the 36 patients. CONCLUSIONS: This retrospective case series demonstrates that the use of high-dose TXA provides is potentially safe and efficacious in adult patients undergoing complex spine surgeries. However, further investigations are required before the true safety and optimal dosing can be determined for high-dose TXA.

20.
J Neurosurg Case Lessons ; 5(10)2023 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-36880510

RESUMO

BACKGROUND: Minimally invasive surgical techniques are changing the landscape in adult spinal deformity (ASD) surgery, enabling surgical correction to be achievable in increasingly medically complex patients. Spinal robotics are one technology that have helped facilitate this. Here the authors present an illustrative case of the utility of robotics planning workflow for minimally invasive correction of ASD. OBSERVATIONS: A 60-year-old female presented with persistent and debilitating low back and leg pain limiting her function and quality of life. Standing scoliosis radiographs demonstrated adult degenerative scoliosis (ADS), with a lumbar scoliosis of 53°, a pelvic incidence-lumbar lordosis mismatch of 44°, and pelvic tilt of 39°. Robotics planning software was utilized for preoperative planning of the multiple rod and 4-point pelvic fixation in the posterior construct. LESSONS: To the authors' knowledge, this is the first report detailing the use of spinal robotics for complex 11-level minimally invasive correction of ADS. Although additional experiences adapting spinal robotics to complex spinal deformities are necessary, the present case represents a proof-of-concept demonstrating the feasibility of applying this technology to minimally invasive correction of ASD.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA