1.
Microsyst Nanoeng ; 9: 92, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37484503

RESUMO

The key risk factor for glaucoma is increased intraocular pressure (IOP). Glaucoma drainage devices implanted in the eye can reduce IOP and thus stop disease progression. However, most devices currently used in clinical practice are passive and do not allow for postsurgical IOP control, which may result in serious complications such as hypotony (i.e., excessively low IOP). To enable noninvasive IOP control, we demonstrate a novel, miniature glaucoma implant that will enable the repeated adjustment of the hydrodynamic resistance after implantation. This is achieved by integrating a magnetic microvalve containing a micropencil-shaped plug that is moved using an external magnet, thereby opening or closing fluidic channels. The microplug is made from biocompatible poly(styrene-block-isobutylene-block-styrene) (SIBS) containing iron microparticles. The complete implant consists of an SIBS drainage tube and a housing element containing the microvalve and fabricated with hot embossing using femtosecond laser-machined glass molds. Using in vitro and ex vivo microfluidic experiments, we demonstrate that when the microvalve is closed, it can provide sufficient hydrodynamic resistance to overcome hypotony. Valve function is repeatable and stable over time. Due to its small size, our implant is a promising, safe, easy-to-implant, minimally invasive glaucoma surgery device.

2.
Macromol Biosci ; 23(10): e2300075, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37249127

RESUMO

Fibrosis of the filtering bleb is one of the main causes of failure after bleb-forming glaucoma surgery. Intraoperative application of mitomycin C (MMC) is the current gold standard to reduce the fibrotic response. However, MMC is cytotoxic and one-time application is often insufficient. A sustained-release drug delivery system (DDS), loaded with MMC, may be less cytotoxic and equally or more effective. Two degradable (polycaprolactone (PCL) and polylactic-co-glycolic acid (PLGA)) MMC-loaded DDSs are developed. Release kinetics are first assessed in vitro followed by rabbit implants in conjunction with the PRESERFLO MicroShunt. As a control, the MicroShunt is implanted with adjunctive use of a MMC solution. Rabbits are euthanized at postoperative day (POD) 28 and 90. The PLGA and PCL DDSs release (on average) 99% and 75% of MMC, respectively. All groups show functioning blebs until POD 90. Rabbits implanted with a DDS show more inflammation with avascular thin-walled blebs when compared to the control. However, collagen is more loosely arranged. The PLGA DDS shows less inflammation, less foreign body response (FBR), and more complete degradation at POD 90 when compared to the PCL DDS. Further optimization with regard to dosage is required to reduce side effects to the conjunctiva.

3.
Adv Biol (Weinh) ; 7(7): e2300051, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37102630

RESUMO

Lowering intraocular pressure (IOP) by placement of a glaucoma shunt is an effective treatment for glaucoma. However, fibrosis of the outflow site can hamper surgical outcome. In this study, the antifibrotic effect of adding an endplate (with or without microstructured surface topographies) to a microshunt made of poly(styrene-block-isobutylene-block-styrene) is investigated. New Zealand white rabbits are implanted with a control implant (without endplate) and modified implants. Afterward, bleb morphology and IOP is recorded for 30 days. After killing of the animals, eyes are collected for histology, Addition of an endplate extended bleb survival, Topography-990 has the longest recorded bleb-survival time. Histology reveals that the addition of an endplate increases the presence of myofibroblasts, macrophages, polymorphonuclear cells, and foreign body giant cells compared to the control. However, an increased capsule thickness and inflammatory response are observed in the groups with surface topographies, The addition of an endplate results in prolonged bleb survival, demonstrating that engineering of the shape of glaucoma implants could prolong bleb functionality. Future research should further elaborate the effect of surface topographies on long-term bleb survival, since an increased presence of pro-fibrotic cells and increased capsule thickness are observed compared to the control.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Animais , Coelhos , Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma/cirurgia , Pressão Intraocular , Olho , Fibrose , Estirenos
4.
PLoS One ; 17(9): e0273672, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36054120

RESUMO

Glaucoma is a group of eye conditions that damage the optic nerve, the health of which is vital for vision. The key risk factor for the development and progression of this disease is increased intraocular pressure (IOP). Implantable glaucoma drainage devices have been developed to divert aqueous humor from the glaucomatous eye as a means of reducing IOP. The artificial drainage pathway created by these devices drives the fluid into a filtering bleb. The long-term success of filtration surgery is dictated by the proper functioning of the bleb and overlying Tenon's and conjunctival tissue. To better understand the influence of the health condition of these tissues on IOP, we have developed a mathematical model of fluid production in the eye, its removal from the anterior chamber by a particular glaucoma implant-the PRESERFLO® MicroShunt-, drainage into the bleb and absorption by the subconjunctival vasculature. The mathematical model was numerically solved by commercial FEM package COMSOL. Our numerical results of IOP for different postoperative conditions are consistent with the available evidence on IOP outcomes after the implantation of this device. To obtain insight into the adjustments in the implant's hydrodynamic resistance that are required for IOP control when hypotony or bleb scarring due to tissue fibrosis take place, we have simulated the flow through a microshunt with an adjustable lumen diameter. Our findings show that increasing the hydrodynamic resistance of the microshunt by reducing the lumen diameter, can effectively help to prevent hypotony. However, decreasing the hydrodynamic resistance of the implant will not sufficiently decrease the IOP to acceptable levels when the bleb is encapsulated due to tissue fibrosis. Therefore, to effectively reduce IOP, the adjustable glaucoma implant should be combined with a means of reducing fibrosis. The results reported herein may provide guidelines to support the design of future glaucoma implants with adjustable hydrodynamic resistances.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Humanos , Fibrose , Glaucoma/cirurgia , Pressão Intraocular
5.
Transl Vis Sci Technol ; 11(8): 29, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-36018582

RESUMO

Purpose: The PreserFlo MicroShunt is an innovative implant for the surgical treatment of glaucoma. Although usually effective, surgeries can still fail due to fibrosis. This study was conducted to gain insight into the histological aspects of the fibrotic response and find potential targets to reduce postoperative fibrosis. Methods: Fifteen New Zealand White rabbits were implanted with a microshunt and followed up for 40 days. Animals were euthanized at postoperative days (PODs) 1, 5, and 40 to collect eyes for histological evaluation. Bleb formation and ocular health were assessed by slit-lamp (SL) biomicroscopy and optical coherence tomography (OCT). Intraocular pressure (IOP) was measured using rebound tonometry. Results: Blebs failed after approximately 2 weeks based on bleb survival and IOP measurements. No severe complications were observed with OCT and SL. Histology revealed a wide variety of cells, in the bleb and around the microshunt, including polymorphonuclear leucocytes (PMNs), myofibroblasts, and foreign body giant cells, at different PODs. Conclusions: Implantation of a poly(styrene-b-isobutylene-b-styrene) microshunt in rabbits resulted in the occurrence of a wide variety of cells during the wound-healing response. Future research should further elucidate the potential of these (earlier often overlooked) cells to target the fibrotic response in vivo-for example, by developing novel antifibrotic drugs, methods for sustained delivery of medications, or augmenting material properties. Translational Relevance: Current antifibrotic therapies aim to inhibit myofibroblasts; however, a wide variety of cells are involved in the fibrotic response. Future research focusing on these cells could offer novel methods for reducing the fibrotic response after glaucoma surgery.


Assuntos
Glaucoma , Lagomorpha , Trabeculectomia , Animais , Coelhos , Fibrose , Cicatrização
6.
Ophthalmol Glaucoma ; 5(2): 195-209, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34329772

RESUMO

PURPOSE: To assess the safety and effectiveness of the PRESERFLO® MicroShunt (formerly InnFocus MicroShunt) in patients with primary open-angle glaucoma (POAG). DESIGN: The MicroShunt, a controlled ab externo glaucoma filtration surgery device, was investigated in a 2-year, multicenter, single-arm study. PARTICIPANTS: Eligible patients were aged 18-85 years with POAG inadequately controlled on maximal tolerated medical therapy with intraocular pressure (IOP) ≥18 and ≤35 mmHg or when glaucoma progression warranted surgery. METHODS: The MicroShunt was implanted as a stand-alone procedure with adjunctive use of topical mitomycin C (MMC; 0.2-0.4 mg/ml) for 2-3 minutes. MAIN OUTCOME MEASURES: The primary effectiveness outcome was IOP reduction and success (not requiring reoperation or pressure failures [IOP > 21 mmHg and < 20% reduction in IOP]) at year 1. Additional end points at year 2 included IOP reduction, success, glaucoma medications, adverse events (AEs), and reoperations. Results are reported in the overall population and subgroups of patients receiving 0.2 or 0.4 mg/ml MMC. RESULTS: In 81 patients, mean (± standard deviation [SD]) IOP decreased from 21.7 ± 3.4 mmHg at baseline to 14.5 ± 4.6 mmHg at year 1 and 14.1 ± 3.2 mmHg at year 2 (P < 0.0001). Overall success (with and without supplemental glaucoma medication use) at year 1 was 74.1%. Mean (± SD) number of medications decreased from 2.1 ± 1.3 at baseline to 0.5 ± 0.9 at year 2 (P < 0.0001), and 73.8% of patients were medication free. Most common nonserious AEs were increased IOP requiring medication or selective laser trabeculoplasty (25.9%) and mild-to-moderate keratitis (11.1%). There were 6 (7.4%) reoperations and 5 (6.2%) needlings by year 2. In an analysis (post hoc) according to MMC concentration, overall success was 78.1% (0.2 mg/ml) and 74.4% (0.4 mg/ml; P = 0.710). In the 0.2 and 0.4 mg/ml MMC groups, 51.9% and 90.3% of patients were medication free, respectively (P = 0.001). There was a trend toward lower IOP and higher medication reduction in the 0.4 mg/ml MMC subgroup. CONCLUSIONS: In this study, mean IOP and glaucoma medication reductions were significant and sustained over 2 years postsurgery. No long-term, sight-threatening AEs were reported. Further studies may confirm potential risk/benefits of higher MMC concentration.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Hipotensão Ocular , Trabeculectomia , Glaucoma/cirurgia , Glaucoma de Ângulo Aberto/tratamento farmacológico , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Pressão Intraocular , Mitomicina , Hipotensão Ocular/cirurgia , Tonometria Ocular
7.
Curr Opin Ophthalmol ; 32(2): 148-159, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33315724

RESUMO

PURPOSE OF REVIEW: Mitomycin C (MMC) is an alkylating agent with extraordinary ability to crosslink DNA, preventing DNA synthesis. By this virtue, MMC is an important antitumor drug. In addition, MMC has become the gold standard medication for glaucoma filtration surgery (GFS). This eye surgery creates a passage for drainage of aqueous humor (AqH) out of the eye into the sub-Tenon's space with the aim of lowering the intraocular pressure. A major cause of failure of this operation is fibrosis and scarring in the sub-Tenon's space, which will restrict AqH outflow. Intraoperative application of MMC during GFS has increased GFS success rate, presumably mainly by reducing fibrosis after GFS. However, still 10% of glaucoma surgeries fail within the first year. RECENT FINDINGS: In this review, we evaluate risks and benefits of MMC as an adjuvant for GFS. In addition, we discuss possible improvements of its use by adjusting dose and method of administration. SUMMARY: One way of improving GFS outcome is to prolong MMC delivery by using a drug delivery system.


Assuntos
Alquilantes/administração & dosagem , Alquilantes/história , Cirurgia Filtrante , Glaucoma/cirurgia , Mitomicina/administração & dosagem , Mitomicina/história , Esclera/efeitos dos fármacos , Sistemas de Liberação de Medicamentos , Fibrose/prevenção & controle , Glaucoma/fisiopatologia , História do Século XX , História do Século XXI , Humanos , Pressão Intraocular/fisiologia
8.
Eye Vis (Lond) ; 6: 36, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31807606

RESUMO

Trabeculectomy remains the 'gold standard' intraocular pressure (IOP)-lowering procedure for moderate-to-severe glaucoma; however, this approach is associated with the need for substantial post-operative management. Micro-invasive glaucoma surgery (MIGS) procedures aim to reduce the need for intra- and post-operative management and provide a less invasive means of lowering IOP. Generally, MIGS procedures are associated with only modest reductions in IOP and are targeted at patients with mild-to-moderate glaucoma, highlighting an unmet need for a less invasive treatment of advanced and refractory glaucoma. The PRESERFLO® MicroShunt (formerly known as InnFocus MicroShunt) is an 8.5 mm-long (outer diameter 350 µm; internal lumen diameter 70 µm) glaucoma drainage device made from a highly biocompatible, bioinert material called poly (styrene-block-isobutylene-block-styrene), or SIBS. The lumen size is sufficiently small that at normal aqueous flow hypotony is avoided, but large enough to avoid being blocked by sloughed cells or pigment. The MicroShunt achieves the desired pressure range in the eye by draining aqueous humor from the anterior chamber to a bleb formed under the conjunctiva and Tenon's capsule. The device is implanted ab externo with intraoperative Mitomycin C via a minimally invasive (relative to incisional surgery) surgical procedure, enabling precise control of placement without the need for gonioscopy, suture tension control, or suture lysis. The implantation procedure can be performed in combination with cataract surgery or as a standalone procedure. The MicroShunt received Conformité Européenne (CE) marking in 2012 and is intended for the reduction of IOP in eyes of patients with primary open-angle glaucoma in which IOP remains uncontrolled while on maximum tolerated medical therapy and/or in which glaucoma progression warrants surgery. Three clinical studies assessing the long-term safety and efficacy of the MicroShunt have been completed; a Phase 3 multicenter, randomized clinical study comparing the MicroShunt to primary trabeculectomy is underway. In preliminary studies, the MicroShunt effectively reduced IOP and use of glaucoma medications up to 3 years after implantation, with an acceptable safety profile. This article summarizes current literature on the unique properties of the MicroShunt, the preliminary efficacy and safety findings, and discusses its potential use as an alternative to trabeculectomy for glaucoma surgery.

9.
J Biomed Mater Res B Appl Biomater ; 105(1): 211-221, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-26380916

RESUMO

Glaucoma is the second leading cause of blindness with ∼70 million people worldwide who are blind from this disease. The currently practiced trabeculectomy surgery, the gold standard treatment used to stop the progression of vision loss, is rather draconian, traumatic to the patient and requires much surgical skill to perform. This article summarizes the more than 10-year development path of a novel device called the InnFocus MicroShunt®, which is a minimally invasive glaucoma drainage micro-tube used to shunt aqueous humor from the anterior chamber of the eye to a flap formed under the conjunctiva and Tenon's Capsule. The safety and clinical performance of this device approaches that of trabeculectomy. The impetus to develop this device stemmed from the invention of a new biomaterial called poly(styrene-block-isobutylene-block-styrene), or "SIBS." SIBS is ultra-stable with virtually no foreign body reaction in the body, which manifests in the eye as clinically insignificant inflammation and capsule formation. The quest for an easier, safer, and more effective method of treating glaucoma led to the marriage of SIBS with this glaucoma drainage micro-tube. This article summarizes the development of SIBS and the subsequent three iterations of design and four clinical trials that drove the one-year qualified success rate of the device from 43% to 100%. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 211-221, 2017.


Assuntos
Glaucoma/cirurgia , Estirenos , Animais , Coelhos , Estirenos/química , Estirenos/farmacologia
10.
J Glaucoma ; 25(2): e58-65, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26766400

RESUMO

AIMS: An observational study to determine the safety and efficacy of filtering surgery employing a microlumen aqueous drainage device (InnFocus MicroShunt), used intraoperatively with Mitomycin C, implanted alone or in combination with phacoemulsification. MATERIALS AND METHODS: Single-site, prospective, nonrandomized study of 23 eyes that had failed maximum tolerated glaucoma medication, followed for 3 years. A MicroShunt was implanted ab externo through a needle tract under the limbus, draining aqueous from the anterior chamber to the scleral surface. Prespecified outcome measures include: intraocular pressure (IOP) control, with and without supplemental medication, success rate, medication use, and adverse events. RESULTS: Fourteen patients received the MicroShunt alone and 9 with cataract surgery. At 1 (n=23), 2 (n=22), and 3 (n=22) years of follow-up; the qualified success rate (IOP ≤ 14 mm Hg and IOP reduction ≥ 20%) was 100%, 91%, and 95%; mean medicated IOP was reduced from 23.8 ± 5.3 to 10.7 ± 2.8, 11.9 ± 3.7, and 10.7 ± 3.5 mm Hg, and the mean number of glaucoma medications/patient was reduced from 2.4 ± 0.9 to 0.3 ± 0.8, 0.4 ± 1.0, and 0.7 ± 1.1, respectively. The most common complications were transient hypotony (13%, 3/23) and transient choroidal effusion (8.7%, 2/23), all resolved spontaneously. There were no leaks, infections, migrations, erosions, persistent corneal edema, or serious long-term adverse events. CONCLUSION: Surgery with the InnFocus MicroShunt transscleral aqueous drainage tube with Mitomycin C achieved IOP control in the low teens in most subjects up to 3 years of follow-up with only transient adverse events occurring within the first 3 months after surgery.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Alquilantes/administração & dosagem , Câmara Anterior/cirurgia , Humor Aquoso/fisiologia , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Mitomicina/administração & dosagem , Facoemulsificação , Estudos Prospectivos , Tonometria Ocular , Acuidade Visual/fisiologia
11.
Ophthalmic Surg Lasers Imaging ; 42(4): 338-45, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21800806

RESUMO

BACKGROUND AND OBJECTIVE: To assess the biocompatibility and intraocular pressure (IOP) lowering effect of a novel glaucoma drainage implant in rabbits. MATERIALS AND METHODS: Sixteen New Zealand white rabbits received one of three glaucoma drainage implants fabricated from poly-(styrene-b-isobutylene-b-styrene [SIBS]) with an internal diameter of the lumen of either 70 (6 eyes), 100 (6 eyes), or 150 (4 eyes) µm. Clinical follow-up examinations were performed during 6 months and postmortem eyes were studied with light microscopy. RESULTS: Smaller internal diameter implants were associated with fewer complications. IOP levels were not statistically different among the groups. No eyes developed serious complications. Mild chronic inflammation was observed around the tube using light microscopy. CONCLUSION: SIBS glaucoma drainage implants did not produce clinically detectable intraocular inflammation in a rabbit model. The 70- and 100-µm SIBS drainage devices demonstrated fewer postoperative complications. IOP levels were not statistically different from control eyes in all groups.


Assuntos
Materiais Biocompatíveis/química , Implantes para Drenagem de Glaucoma , Pressão Intraocular/fisiologia , Implantação de Prótese , Estirenos/química , Animais , Feminino , Coelhos
12.
Am J Ophthalmol ; 143(2): 317-327, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17169319

RESUMO

PURPOSE: To evaluate the anatomical effects and tissue biocompatibility in a feline model of an integrated orbital tissue expander (OTE) designed to stimulate bone growth in an anophthalmic socket. DESIGN: An animal study was performed in cats to assess orbital bone growth with and without an OTE. METHODS: The OTE is an inflatable (0.5 to >6.0 cm(3)) polymeric globe sliding on a titanium T plate secured to the lateral orbital rim with screws. Eight cats had left eye enucleation at age two weeks, with five orbits receiving an OTE and the remaining three serving as nonimplanted controls. Serial transconjunctival implant inflation was performed by injecting normal saline solution into the OTE to a final volume of 3.5 ml. Serial computed tomographic scans were obtained to assess socket growth. All eight cats were euthanized at 18 weeks and dry skulls prepared. The effective orbital volume was measured by inflating an OTE in the orbit of a dry skull until it filled the cavity completely. RESULTS: Three cats periodically scratched open the tarsorrhaphy and conjunctiva to rupture the OTE, which resulted in implant exchanges. At 18 weeks, the OTE expanded orbital volume was approximately 18% smaller than the normal contralateral side. In the control animals, the anophthalmic orbital volume was approximately 66% smaller than the contralateral orbit. Histopathology of orbital tissues showed no evidence of foreign body reaction. CONCLUSIONS: This proof-of-concept pilot study demonstrated implant efficacy in cats, and no implant-related adverse effects were observed. OTE has the potential to stimulate bone growth in human anophthalmic orbits.


Assuntos
Anoftalmia/cirurgia , Materiais Biocompatíveis , Desenvolvimento Ósseo , Órbita/cirurgia , Dispositivos para Expansão de Tecidos , Expansão de Tecido/métodos , Animais , Anoftalmia/diagnóstico por imagem , Anoftalmia/patologia , Gatos , Enucleação Ocular , Modelos Animais , Órbita/diagnóstico por imagem , Órbita/patologia , Projetos Piloto , Poli-Hidroxietil Metacrilato , Dispositivos de Fixação Cirúrgica , Expansão de Tecido/instrumentação , Tomografia Computadorizada por Raios X
13.
Arch Ophthalmol ; 124(12): 1742-9, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17159034

RESUMO

OBJECTIVE: To report clinical evaluation, flow patency, and histopathological findings of a novel glaucoma drainage implant (GDI) made of poly(styrene-b-isobutylene-b-styrene) (SIBS) in rabbits. METHODS: In 16 normal eyes, the proximal end of the SIBS GDI was inserted into the anterior chamber while the distal end was placed in the subconjunctival space. A control group underwent implantation of a similarly designed silicone GDI. Slitlamp follow-up and intraocular pressure measurements were recorded. Flow patency was evaluated by injecting 0.01% fluorescein into the anterior chamber. Immunostaining against collagen IV, macrophages, and alpha smooth muscle actin was performed. RESULTS: Slitlamp examination suggested adequate biocompatibility. A low and diffuse bleb was observed in the SIBS group. All SIBS tubes were patent 6 months after insertion. Immunostaining demonstrated noncontinuous collagen deposition. No macrophages or myofibroblasts were visible around the SIBS tubes. In contrast, silicone induced collagen deposition and myofibroblast differentiation. CONCLUSION: This new GDI is clinically biocompatible in the rabbit and maintained 100% patency at 6 months. A remarkable difference was the absence of myofibroblasts in the surrounding tissue in the SIBS group. CLINICAL RELEVANCE: This novel GDI made of SIBS would prevent the feared complication of hypotony and will decrease the amount of subconjunctival fibrosis.


Assuntos
Câmara Anterior/cirurgia , Humor Aquoso/metabolismo , Materiais Biocompatíveis , Implantes para Drenagem de Glaucoma , Implantação de Prótese , Estirenos , Actinas/análise , Animais , Câmara Anterior/química , Colágeno Tipo IV/análise , Feminino , Fluorofotometria , Pressão Intraocular , Macrófagos/citologia , Teste de Materiais , Desenho de Prótese , Coelhos
14.
J Biomed Mater Res B Appl Biomater ; 79(2): 325-34, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16649171

RESUMO

A novel polyolefin, poly(styrene-b-isobutylene-b-styrene) (Quatromer), is being proposed as a viable polymer for use in trileaflet heart valves because of its oxidative stability. The current study was designed to assess the polymer's hemocompatibility and mechanical durability. Mechanical characterization included static tensile tests and dynamic tension-tension and bending fatigue tests, where the properties of isotropic and composite (polypropylene (PP) embedded) Quatromer specimens were compared with those of a polyurethane (PUR) approved for cardiovascular applications. It was found that by embedding PP fibers into the Quatromer matrix, the tensile and fatigue properties of the polymer could be improved, making them comparable, if not better than the PUR. The thrombotic potential of Quatromer was compared with the PUR, glutaraldehyde-fixed porcine valve material, and a positive and negative control by measuring platelet deposition with radiolabeled platelets in a parallel plate flow configuration. The porcine valve material was found to have significantly higher platelet deposition under all flow regimes, while no significant difference existed between Quatromer and PUR. In conclusion, Quatromer is shown to have suitable hemocompatibility and mechanical durability for use in polymer trileaflet heart valves, and fiber reinforcement can effectively be used to tailor the mechanical properties.


Assuntos
Materiais Biocompatíveis , Próteses Valvulares Cardíacas , Estirenos , Animais , Plaquetas , Humanos , Teste de Materiais , Suínos