Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
2.
Artigo em Inglês | MEDLINE | ID: mdl-37995108

RESUMO

Although during recent decades the prompt clinical management of myocardial infarction has significantly reduced the incidence of mechanical complications, post-infarction heart failure is still an open issue. The surgical ventricular reconstruction technique, also called the "Dor procedure", was introduced as a surgical strategy to reduce left ventricular volume and restore its shape and function by performing an endoventricular circular patch plasty. Although its use was not clearly beneficial, there is growing evidence from specialized centres suggesting its safety and efficacy, thus bringing this technique back to a leading role in the surgical armamentarium to treat patients with heart failure. The objective of this work was to present a step-by-step explanation of the Dor procedure as a landmark for all surgeons who want to perform it.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Aneurisma Cardíaco , Insuficiência Cardíaca , Infarto do Miocárdio , Humanos , Aneurisma Cardíaco/cirurgia , Infarto do Miocárdio/complicações , Procedimentos Cirúrgicos Cardíacos/métodos , Ventrículos do Coração/cirurgia
3.
Eur J Cardiothorac Surg ; 64(2)2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37410123

RESUMO

OBJECTIVES: The aim of this study was to investigate the impact of Valve Academic Research Consortium 3 minor access site vascular complications (VCs) in patients who underwent percutaneous transfemoral (TF) transcatheter aortic valve implantation (TAVI). METHODS: This single-centre retrospective study included consecutive patients who underwent percutaneous TF-TAVI from 2009 to 2021. A propensity score-matched analysis was performed to compare early and long-term clinical results between patients with VC and without VC (nVC). RESULTS: A total of 2161 patients were included, of whom 284 (13.1%) experienced access site VC. Propensity score analysis allowed to match 270 patients from the VC group with 727 patients from the nVC group. In the matched cohorts, the VC group showed longer operative times (63.5 vs 50.0 min, P < 0.001), higher operative and in-hospital mortality (2.6% vs 0.7%, P = 0.022; and 6.3% vs 3.2%, P = 0.040, respectively), longer hospital length of stay (8 vs 7 days, P = 0.001) and higher rates of blood transfusion (20.4% vs 4.3%, P < 0.001) and infectious complications (8.9% vs 3.8%, P = 0.003). Overall survival during follow-up was significantly lower in the VC group (hazard ratio 1.37, 95% CI 1.03-1.82, P = 0.031) with 5-year survival rates being 58.0% (95% CI 49.5-68.0%) and 70.7% (95% CI 66.2-75.5%) for the VC and nVC groups, respectively. CONCLUSIONS: This retrospective study observed that minor access site VCs during percutaneous TF-TAVI can be serious events affecting early and long-term outcomes.


Assuntos
Estenose da Valva Aórtica , Doenças Cardiovasculares , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Resultado do Tratamento , Doenças Cardiovasculares/cirurgia , Valva Aórtica/cirurgia , Artéria Femoral/cirurgia
4.
Eur J Cardiothorac Surg ; 63(6)2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37208162

RESUMO

OBJECTIVES: The aim of this study was to investigate the long-term outcomes of concomitant suture bicuspidization to treat mild or moderate tricuspid regurgitation at the time of mitral valve (MV) surgery. METHODS: Data from patients who underwent MV surgery for degenerative MV regurgitation with mild or moderate tricuspid regurgitation and annular dilatation between January 2009 and December 2017 were analysed. The cohort was divided into 2 groups: mitral valve surgery alone (MVA) and MV surgery with concomitant tricuspid valve (TV) repair. RESULTS: A total of 196 patients were included in the study. MVA and MV surgery with concomitant TV repair were performed in 91 (46.4%) and 105 (53.6%) patients, respectively. Propensity score matching analysis identified 54 pairs. In the matched cohort, 30-day mortality (0.0% vs 1.9%, P = 1.0) and new permanent pacemaker implantation (11.1% vs 7.4%, P = 0.740) did not differ significantly between groups. After a mean follow-up of 6.0 (2.8) years, MV surgery with concomitant TV repair was not associated with increased mortality risk compared to MVA (hazard ratio 1.04, 95% confidence interval 0.47-2.28, P = 0.927) with 10-year overall survival rates of 69.9% and 77.2%, respectively. Furthermore, MV surgery with concomitant TV repair was associated with a significantly reduced progression of TV regurgitation (P < 0.001). CONCLUSIONS: Patients undergoing MV surgery with concomitant TV repair had similar 30-day and long-term survival, similar permanent pacemaker implantation rate and reduced progression of TV regurgitation compared to those undergoing MVA.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/complicações , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Suturas , Estudos Retrospectivos
5.
J Pers Med ; 12(11)2022 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-36422071

RESUMO

BACKGROUND: Minimally invasive procedures have demonstrated their effectiveness in reducing the recovery times while ensuring optimal results and minimizing complications. Regarding the coronary artery surgical revascularization field, the evolution of techniques and technology is permitting new surgical strategies that are increasingly precise and suitable for each patient. We present an initial single center experience with a case series of patients successfully treated with combined robotic harvesting of the left internal mammary artery (LIMA) and minimally invasive direct coronary artery bypass graft (MIDCAB) for the anastomosis. METHODS: We retrospectively reviewed the records of patients who underwent minimally invasive coronary artery revascularization with the use of two combined techniques at our Institution between January 2021 and October 2022. RESULTS: A total of 17 patients underwent coronary artery bypass grafting with the described approach. The median cardiopulmonary bypass (CPB) and cross-clamp times were 83 min (76-115) and 38 min (32-58), respectively. The median intensive care unit (ICU) and hospital stay were 2 days (1-4) and 8 days (6-11), respectively. The procedure's success was achieved in 100% of patients. The 30-day mortality was 0%. CONCLUSIONS: Considering all the limitations related to the small sample, the presented results of a hybrid approach for minimally invasive coronary artery bypass grafting (CABG) appears to be encouraging and acceptable. The main advantage of this approach is related to the reduction of postoperative pain and pulmonary complications.

6.
Eur J Cardiothorac Surg ; 62(5)2022 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-36190347

RESUMO

OBJECTIVES: Clinical outcomes of 2 generations of pericardial bioprostheses in concomitant aortic valve and coronary artery bypass graft surgery were analysed. METHODS: Patients were recruited from 2 European centres and divided into 2 groups based on the type of aortic bioprosthesis used: Edwards Intuity Elite™ rapid-deployment (RD) bioprostheses or standard Edwards Magna Ease (ME). A propensity score weighting approach was used for data analysis. RESULTS: A total of 285 patients were included: 144 (50.5%) in the RD group and 141 (49.5%) in the ME group. Thirty-day mortality was 2.8% (RD) and 5% (ME) (P = 0.09). Significantly shorter times of aortic cross-clamp and cardiopulmonary bypass were observed in the RD cohort [94 vs 120 min (P < 0.001); 128 vs 160 min (P < 0.001)]. The RD group was associated with a lower median transvalvular gradient at discharge and follow-up (both P < 0.001). However, 5-year survival was not different, being 93% in RD patients and 91% in the ME group [hazard ratio 0.89 (95% confidence interval: 0.38-2.09), P = 0.784]. The 5-year cumulative incidence of combined events (including percutaneous coronary interventions, endocarditis, thromboembolic events, rehospitalizations and bleeding) favoured the ME group [16.1% (RD) vs 7.3% (ME)] [hazard ratio 2.38 (95% confidence interval:1.03-5.52), P = 0.043]. However, this turned similar when the Cox model analysis was adjusted for revascularization variables (P = 0.067). CONCLUSIONS: RD and ME pericardial bioprostheses used in concomitant aortic valve replacement and coronary artery revascularization provide equivalent clinical and haemodynamic 5-year outcomes, despite constant lower transvalvular gradients and shorter surgical operating times observed with RD technology.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Ponte de Artéria Coronária , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Desenho de Prótese , Resultado do Tratamento
7.
J Card Surg ; 37(9): 2564-2570, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35726653

RESUMO

BACKGROUND AND AIM OF THE STUDY: To evaluate whether the simplified valve-sparing technique (SVST) implies clinical outcomes comparable or not with those of established David technique in the surgery of aortic root. METHODS: We collected the records of patients who had undergone aortic root surgery with the SVST or standard David technique (SDT) at our institution between January 2009 and December 2018. The primary endpoints were the incidence of all-cause death, reoperation for any reason, and postoperative complications. The secondary endpoint was the midterm incidence of reoperation for aortic valve regurgitation. RESULTS: A total of 169 patients who underwent aortic root surgery were analyzed. SDT and SVST were performed in 48 (28.4%) and in 121 (71.6%) patients, respectively. Thirty-day mortality occurred in 0% and 0.8% of patients in the SDT and SVST groups, respectively. The rate of postoperative new permanent pacemaker implantation was 6.3% (three patients) and 0.8% (one patient) in SDT and SVST cohort, respectively (p = .07). The incidence of postoperative thromboembolic stroke was 6.3% and 2.5% in SDT and SVST groups, respectively (p = .23). The median follow-up time was 29 (23-47) months. During the FU period, no differences were found between two cohorts in terms of all-cause mortality (p = .99), the incidence of reoperation (p = .19), and incidence of aortic valve regurgitation requiring reoperation (p = .58). CONCLUSIONS: The SVST appears to be safe and feasible showing early clinical results comparable to the SDT. Nevertheless, further studies with larger series and long-term follow-ups are required to demonstrate its safety and efficacy.


Assuntos
Aneurisma Aórtico , Insuficiência da Valva Aórtica , Implante de Prótese Vascular , Aneurisma Aórtico/cirurgia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Estudos de Viabilidade , Humanos , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
8.
J Card Surg ; 37(9): 2633-2639, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35598309

RESUMO

OBJECTIVES: The hypothermic circulatory arrest is a major limitation of the frozen elephant trunk (FET) technique, associated with a high incidence of postoperative mobility and mortality. The aim of this study was to evaluate the surgical outcomes of patients suffering from different aortic arch diseases treated with the release and perfuse technique (RPT). METHODS: We retrospectively reviewed the records of patients who had undergone aortic arch repair with the RPT at our Institution between October 2019 and September 2021. Preoperative, intra-operative, and postoperative data were collected. RESULTS: A total of 18 patients undergoing aortic arch surgery with the use of RPT were analyzed. Twelve of them (67%) were males, and the median age of the entire cohort was 67 (56-73) years. The primary indications for surgery included acute type A aortic dissection (50%), chronic type B aortic dissection (33%), and chronic aneurysms (17%). The median cardiopulmonary bypass-, aortic cross-clamp- and circulatory arrest times were 163 (147-213) min, 69 (51-120) min, and 10 (8-13) min, respectively. The median intensive care unit and hospital stay were 4 (2-7) and 12 (11-16) days, respectively. One patient (6%) died during the first 30 days after surgery. CONCLUSIONS: Considering the anatomical limitations related to the use of this technique, the RPT can be safely performed and could represent a promising strategy to reduce the circulatory arrest time during aortic arch surgery. Nevertheless, further studies are required to demonstrate its efficacy.


Assuntos
Aneurisma da Aorta Torácica , Doenças da Aorta , Dissecção Aórtica , Implante de Prótese Vascular , Idoso , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/métodos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
9.
Ann Thorac Surg ; 114(5): e389-e392, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35189112

RESUMO

Prosthetic replacement of the aortic arch requires a cardiopulmonary bypass and deep hypothermic circulatory arrest. Thus, it is associated with major perioperative risks, and custom-made devices have been developed. However, the time required for this procedure precludes emergency cases, and anatomical prerequisites limit the creation of appropriate devices. Here, we present a totally endovascular approach that allowed an exclusion of the aortic arch with the usual commercial devices. We explain, step by step, the procedure and the materials carefully selected for each step.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Humanos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Ponte Cardiopulmonar/métodos , Lasers , Resultado do Tratamento , Parada Circulatória Induzida por Hipotermia Profunda
10.
J Card Surg ; 37(4): 1059-1062, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35060195

RESUMO

INTRODUCTION: The coronavirus disease 2019 (COVID-19) causes a small proportion of patients to be admitted to intensive care units, where they sometimes require extracorporeal membrane oxygenation (ECMO). The literature on pregnant women with COVID-19 who require ECMO is sparse. CASE REPORT: We describe here the earliest-fetal-age pregnant patient with COVID-19 who underwent ECMO yet reported, who kept her child while under close follow-up with magnetic resonance imagery and ultrasound. CONCLUSION: The management of acute respiratory distress syndrome (ARDS) in pregnant women, including ARDS secondary to COVID-19 and those cases which are not eligible for fetal delivery, may benefit from the assistance of ECMO even in the early pregnancy.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Síndrome do Desconforto Respiratório , COVID-19/complicações , COVID-19/terapia , Criança , Contraindicações , Feminino , Idade Gestacional , Humanos , Gravidez , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Síndrome do Desconforto Respiratório/etiologia , Síndrome do Desconforto Respiratório/terapia , SARS-CoV-2
11.
Aging Clin Exp Res ; 34(3): 643-652, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34448150

RESUMO

BACKGROUND: Surgical aortic valve replacement (SAVR) is still the gold standard for treating aortic valve stenosis (AVS). Its effectiveness has been extensively examined in terms of perioperative mortality, but its impact on overall health has received much less attention. AIMS: To assess the physical performance, cognitive status, and health-related quality of life of elderly patients undergoing SAVR, in the short, medium and long term. METHODS: This single-center prospective study enrolled patients aged > 70 years who underwent isolated SAVR for severe AVS. Data were collected on each participant's clinical status, physical performance, cognitive status, mood, and health-related quality of life. This multidimensional geriatric assessment was performed before surgery (T0), and again at 45 days (T1), 3 months (T2), 6 months (T3), and 12 months (T4) post-surgery. Baseline (T0) and follow-up (T2-T4) data were compared separately for patients grouped by gender using paired t-tests. RESULTS: Data from a total of 35 patients were analyzed. Compared with the baseline (T0), nutritional status worsened at T1, then gradually improved through to T4. Physical performance, mood, and health-related quality of life improved significantly after surgery. Cognitive function showed no change through to T3, but then deteriorated at T4. CONCLUSIONS: Our results show that SAVR in patients over 70 years of age has a positive impact on nutrition, mood, and health-related quality of life. Cognitive function was not negatively affected in the short and medium term, although it deteriorated in the long term. SAVR also had a positive impact on the physical performance of our sample.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Cognição , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desempenho Físico Funcional , Estudos Prospectivos , Qualidade de Vida , Fatores de Risco , Resultado do Tratamento
12.
Eur J Cardiothorac Surg ; 61(4): 828-835, 2022 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-34302165

RESUMO

OBJECTIVES: The aim of this retrospective multicentre study was to investigate and compare clinical outcomes of unilateral and bilateral antegrade cerebral perfusion (ACP) strategies on cerebral protection during surgery for type A aortic dissection. METHODS: Data from 646 patients who underwent surgical repair of thoracic type A aortic dissection using unilateral and bilateral ACP with moderate hypothermic circulatory arrest in 3 cardiac surgical institutions between 2008 and 2018 were analysed. Propensity matching was performed to assess which technique ensured better outcomes. RESULTS: Unilateral and bilateral ACP techniques were performed in 250 (39%) and in 396 (61%) patients, respectively. Propensity score analysis identified 189 matched pairs. In the matched cohort, the lowest core temperature was 27.5°C and 28°C in the bilateral and unilateral groups, respectively (P < 0.001). The unilateral technique required significantly shorter aortic cross-clamp and cardiopulmonary bypass times than bilateral technique [82 min vs 100 min (P < 0.001); 170 min vs 195 min (P < 0.001)]. The 30-day mortality was comparable (P = 0.325). The bilateral group reported a significantly higher incidence of permanent neurologic deficits (P < 0.001), left brain hemisphere stroke (P = 0.007) and all-combined complications (P < 0.001). Ten-year survival was comparable (P = 0.45). CONCLUSIONS: Unilateral and bilateral ACP are both valid brain protection strategies in the landscape of aortic arch surgery. While admitting all the study limitations, unilateral technique could offer some clinical advantages. CLINICAL REGISTRATION NUMBER: 76049.


Assuntos
Dissecção Aórtica , Circulação Cerebrovascular , Dissecção Aórtica/cirurgia , Aorta Torácica/cirurgia , Parada Circulatória Induzida por Hipotermia Profunda , Humanos , Perfusão/métodos , Estudos Retrospectivos , Resultado do Tratamento
13.
Eur J Cardiothorac Surg ; 61(4): 888-896, 2022 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-34962258

RESUMO

OBJECTIVES: The goal of this multicentre retrospective study was to compare long-term clinical and haemodynamic outcomes of the Carpentier-Edwards Magna Ease (CEME) bioprosthesis by patient age. METHODS: We included consecutive patients who underwent isolated and combined surgical aortic valve replacement (AVR) with CEME valve between January 2008 and March 2020 at 4 cardiac surgery centres in Italy. Survival distribution was evaluated at follow-up according to age and surgery type (combined or isolated AVR), together with freedom from structural valve deterioration (SVD), reoperation and combined events, i.e. SVD, reoperation, endocarditis and thromboembolic events. RESULTS: A total of 1027 isolated and 1121 combined AVR were included; 776 patients were younger than 65 years whereas 1372 were 65 years or older. The 30-day Valve-Academic-Research-Consortium mortality was 2% (<65 years) and 6% (≥ 65 years) (P < 0.001), whereas it was 3% for isolated AVR and 7% for combined AVR (P < 0.001). The 12-year survival was 81% for those younger than 65 years vs 45% for those equal to or older than 65 years (P < 0.001), whereas they were 61% vs 49% for isolated and combined AVR (P = 0.10). The 12-year freedom from combined events, excluding death, was 79% for those younger than 65 years vs 87% for those equal to or older than (P = 0.51), whereas they were 83% for isolated and 86% for combined AVR (P = 0.10). The 12-year freedom from SVD was 93% and 93% in patients younger than 65 and those equal to or older than 65 years (P = 0.63), and the results were comparable even in cases with isolated and combined AVR (92% vs 94%, P = 0.21). A multivariable Cox analysis including gender, presence of patient-prosthesis mismatch, isolated AVR and age showed that only the age was an independent risk factor for the incidence of SVD (P = 0.029). CONCLUSIONS: Outcomes from this large multicentre analysis demonstrated that a CEME bioprosthesis provides good clinical results and long-term durability even in patients younger than 65 years. Furthermore, the hazard for SVD has been shown to be lower for older age. CLINICAL TRIAL REGISTRATION NUMBER: 105n/AO/21.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Seguimentos , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos
14.
J Clin Med ; 10(22)2021 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-34830720

RESUMO

(1) Background: Although transcatheter technology is rapidly growing and represents a promising strategy, the surgical approach remains the best way to repair a degenerative mitral valve regurgitation. In this context, robotic surgery is technologically the most advanced method of minimally invasive mitral valve repair. The aim of this study is to present the preliminary results of the initial single-center experience with a new robotic mitral valve repair program. (2) Methods: We retrospectively reviewed the records of patients who underwent robotic mitral valve repair at our Institution between January and September 2021. (3) Results: A total of 29 patients underwent mitral valve repair with annuloplasty and chordal implantation to treat degenerative mitral regurgitation. The procedure's success was achieved in 97% of patients. The 30-day cardiac-related mortality was 0%. The median CPB and cross-clamp times were 189 and 111 min, respectively, with a progressive reduction from the beginning of the robotic program. (4) Conclusions: Considering all the limitations related to the small sample, the presented results of robotic mitral valve repair appear to be encouraging and acceptable. A careful patient selection, a dedicated team, and a robust experience in surgical mitral valve repair are the fundamentals to start a new robotic mitral surgery program.

16.
Eur J Cardiothorac Surg ; 61(1): 235-237, 2021 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-34382065

RESUMO

Although the frozen elephant trunk technique permits a complete single-stage treatment in patients with extended thoracic aortic disease, the problem of circulatory arrest time remains unsolved. We propose a simplified use of the Thoraflex Hybrid prosthesis to minimize the circulatory arrest time.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Implante de Prótese Vascular/métodos , Humanos , Resultado do Tratamento
20.
J Card Surg ; 35(11): 3116-3119, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32949043

RESUMO

BACKGROUND: HeartMate 3 is a left ventricular assist device, composed of a centrifugal pump. It can be applied as a myocardial recovery, a bridge to transplant, or a destination therapy, in the treatment of patients with left ventricular heart failure. METHODS: Herein we describe a technique applied against a giant aneurysmal dilatation, which combines a surgical device implantation and a left ventricular reconstruction using a double patch. RESULTS: The patch minimizes thrombotic risk thanks to its internal bovine pericardium layer, which is in contact with blood. CONCLUSIONS: The outlined technique is relatively reproducible and safe in a selected group of patients, as it employs a high-quality device and enables the restoration of an appropriate ventricular geometry.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Aneurisma Cardíaco/cirurgia , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/cirurgia , Coração Auxiliar , Procedimentos de Cirurgia Plástica/métodos , Desenho de Prótese , Implantação de Prótese/métodos , Animais , Bovinos , Aneurisma Cardíaco/complicações , Insuficiência Cardíaca/etiologia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA