Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Coll Antropol ; 37 Suppl 1: 127-31, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23837231

RESUMO

The aim of this study was to compare antimicrobial efficacy of rigid contact lens disinfecting solutions. We tested five commercially available solutions: Unique pH (Alcon Laboratories), Boston Advance (Polymer Technology Corp.), Nitilens Conditioner GP (Avizor), Total Care (AMO), Boston Simplus (Bausch&Lomb). Their efficacy to disinfect saline solution experimentally contaminated with American Type Culture Collection (ATCC): Staphylococcus aureus (ATCC 25923), Escherichia coli (ATCC 25922), Pseudomonas aeruginosa (ATCC 27853), Candida albicans (ATCC 90028) and Staphylococcus epidermidis (isolated from our laboratory) was tested. All tested solutions reduced concentrations of bacteria and fungi below 1000 CFU/mL (Colony forming unit; reduction by 3 log and 1 log, respectively) after the 8 hours period. Overall, all contact lens care solutions showed good disinfecting activity against tested bacteria and fungi, with more variation in their antifungal than in antibacterial efficacy. Results of our study might be valuable when selecting appropriate solutions for non-compliant contact lens wearers.


Assuntos
Antibacterianos/farmacologia , Antifúngicos/farmacologia , Soluções para Lentes de Contato/farmacologia , Lentes de Contato
2.
Acta Med Croatica ; 59(4): 337-40, 2005.
Artigo em Servo-Croata (Latino) | MEDLINE | ID: mdl-16334742

RESUMO

Dry eye syndrome is a common clinical entity causing difficulties to many people, especially the elderly. Standard substitution therapy with artificial tears may frequently prove inadequate, thus any new treatment modality is highly welcome. The syndrome implies lacrimal hyperosmolality, which in turn results in mucus accumulation in the conjunctival sac causing additional irritation. Locally applied acetylcysteine, a mucolytic, regulates mucus secretion and reduces mucus accumulation. The aim of the study was to compare the efficacy of artificial tear therapy and therapy with local acetylcysteine. The study included 32 patients with the symptoms and signs of dry eye attending our department between March 20 and May 9, 2003. All study patients were on long-term substitution therapy with artificial tears. Upon evaluation of subjective discomforts and objective signs, the patients were switched from artificial tear therapy (Isopto-Tears, Alcon, with polyvinyl alcohol as active ingredient) to therapy with locally applied acetylcysteine (Brunac, Bruschettini). All parameters were re-evaluated at 2-week control visit. Thirty of 32 patients (94%) completed the study with control visit. Of these, 18 (60%) patients reported reduction of subjective discomforts, ten (33%) patients observed no change, and two (7%) patients experienced more discomforts with acetylcysteine than with artificial tear therapy. On objective sign evaluation, 12 (40%) patients showed less discomforts, unchanged condition was recorded in 13 (43%) patients, and five (17%) patients had more discomforts as compared with artificial tear therapy. A statistically significant difference (p=0.05) between artificial tear therapy and acetylcysteine therapy was found for the subjective symptom score but not for the objective sign score. Therapy with acetylcysteine proved more efficient than artificial tears in reducing subjective symptoms but had no effect on the objective signs of dry eye syndrome. The advantages of acetylcysteine include more convenient instillation timing (4 times daily) and reduced nocturnal discomfort, whereas shortcomings are the sense of burning on instillation, bad odor, and as yet relatively high price on the Croatian market.


Assuntos
Acetilcisteína/administração & dosagem , Síndromes do Olho Seco/tratamento farmacológico , Expectorantes/administração & dosagem , Soluções Oftálmicas , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
Coll Antropol ; 29 Suppl 1: 21-4, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16193670

RESUMO

Quality assessment of clinical health care with the programme of quality standard is a method of health management, through which better efficiency and safety of health outcomes can be achieved. In the period from 2002 to 2004, a pilot program of quality has been carried out on the Department of Ophthalmology, University Hospital Center in Zagreb. Seven internal audit teams of hospital commission and teams of hospital departments were evaluating introducing practice for quality standards every three months. In the period of two years improvement in all standards of quality has been noticed (expressed in percent of progress towards the ideal result of 100%): personnel 20%, patient rights 15%, medical equipment 40%, quality of emergency service 60%, implementation of clinical guidelines and criteria for elective admission 55%, quality of risk prevention 70%, quality of medical records 60%. The two-years-improvement dynamics of about 46%, first year 24%.


Assuntos
Departamentos Hospitalares/organização & administração , Auditoria Médica , Oftalmologia/organização & administração , Gestão da Qualidade Total/métodos , Croácia , Eficiência Organizacional , Humanos , Guias de Prática Clínica como Assunto
4.
Acta Med Croatica ; 59(2): 143-6, 2005.
Artigo em Servo-Croata (Latino) | MEDLINE | ID: mdl-15909889

RESUMO

Secondary glaucoma is a relatively common complication after pars plana vitrectomy and silicone oil injection for repair of complex retinal detachment. The aim of this study was to evaluate the influence of silicone oil tamponade on intraocular pressure elevation and to identify the mechanism of this elevation. The study included 45 eyes of 45 patients who had undergone pars plana vitrectomy and silicone oil tamponade for repair of complex retinal detachment. Ophthalmic examination was performed before vitrectomy, and one and six months after vitrectomy. The increase in intraocular pressure was measured one month postoperatively in 37.77% of patients. The mechanism of intraocular pressure increase was silicone oil emulsification in 52.98%, closure of Ando's iridectomy in 23.54%, and idiopathic angle closure glaucoma in 23.54% of patients with elevated intraocular pressure. After silicone oil removal, elevated intraocular pressure persisted in 7 (15.55%) patients; in 5 patients it was controlled medically, while two patients underwent glaucoma surgery. Six months postoperatively 3 patients developed secondary neovascular glaucoma due to the prolipherative ischemic disease. Elevation of intraocular pressure following vitrectomy with silicone oil tamponade had a temporary effect, as it did not lead to permament intraocular pressure elevation but regressed after silicone oil removal from the eye.


Assuntos
Glaucoma/etiologia , Pressão Intraocular , Descolamento Retiniano/cirurgia , Óleos de Silicone/administração & dosagem , Vitrectomia/efeitos adversos , Humanos , Vitrectomia/métodos
5.
Ophthalmologica ; 218(3): 214-8, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15103220

RESUMO

Although the WHO document WHO/PBL/93.29 recommends the bilamellar tarsal rotation operation for trachomatous entropion, we will describe another operation that has proved to be very reliable. It is a combined method, consisting of the modified tarsal wedge resection and the eversion splinting-grey line incision. A possible additional correction of the grey line incision on the first postoperative day improves the results. A total of 708 eyes with moderate trachomatous entropion and major trichiasis underwent this surgery, but only 508 of these were followed up during a 6-month period. The rate of failed operations, which consisted of incomplete closure of the lids or more than two inverted lashes remaining, was 6.9%.


Assuntos
Entrópio/microbiologia , Entrópio/cirurgia , Pestanas , Doenças do Cabelo/microbiologia , Doenças do Cabelo/cirurgia , Tracoma/complicações , Pálpebras/cirurgia , Feminino , Humanos , Masculino , Técnicas de Sutura , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA