Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur Heart J Qual Care Clin Outcomes ; 9(4): 417-426, 2023 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35876646

RESUMO

BACKGROUND: Multisite artery disease is considered a 'malignant' type of atherosclerotic disease associated with an increased cardiovascular risk, but the impact of multisite artery disease on clinical outcomes after percutaneous coronary intervention (PCI) is unknown. METHODS: Patients enrolled in the large, prospective e-Ultimaster study were grouped into (1) those without known prior vascular disease, (2) those with known single-territory vascular disease, and (3) those with known two to three territories (i.e coronary, cerebrovascular, or peripheral) vascular disease (multisite artery disease). The primary outcome was coronary target lesion failure (TLF), defined as the composite of cardiac death, target vessel-related myocardial infarction, and clinically driven target lesion revascularization at 1-year. Inverse propensity score weighted (IPSW) analysis was performed to address differences in baseline patient and lesion characteristics. RESULTS: Of the 37 198 patients included in the study, 62.3% had no prior known vascular disease, 32.6% had single-territory vascular disease, and 5.1% had multisite artery disease. Patients with known vascular disease were older and were more likely to be men and to have more co-morbidities. After IPSW, the TLF rate incrementally increased with the number of diseased vascular beds (3.16%, 4.44%, and 6.42% for no, single, and multisite artery disease, respectively, P < 0.01 for all comparisons). This was also true for all-cause death (2.22%, 3.28%, and 5.29%, P < 0.01 for all comparisons) and cardiac mortality (1.26%, 1.91%, and 3.62%, P ≤ 0.01 for all comparisons). CONCLUSIONS: Patients with previously known vascular disease experienced an increased risk of adverse cardiovascular events and mortality post-PCI. This risk is highest among patients with multisite artery disease.Trial Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02188355.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Masculino , Humanos , Feminino , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento , Sistema de Registros , Artérias
2.
Coron Artery Dis ; 32(5): 391-396, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-33060529

RESUMO

OBJECTIVES: Recent improvements in coronary stent design have focussed on thinner struts, different alloys and architecture, more biocompatible polymers, and shorter drug absorption times. This study evaluates safety and efficacy of a newer generation thin-strut cobalt chromium sirolimus-eluting coronary stent (SES, Ultimaster) in comparison with a second-generation thicker strut stainless steel biolimus-eluting stent (BES, Nobori) in percutaneous coronary intervention (PCI) practice. METHODS: A propensity score analysis was performed to adjust for differences in baseline characteristics of 8137 SES patients and 2738 BES patients of two PCI registries (e-Ultimaster and NOBORI 2). An independent clinical event committee adjudicated all endpoint-related adverse events. RESULTS: The use of SES, as compared with BES was associated with a significantly lower rate of myocardial infarction (MI) (1.2% vs 2.2%; P = 0.0006) and target vessel-related MI (1.1% vs 1.8%; P = 0.002) at 1 year. One-year composite endpoints of all predefined endpoints were lower in patients undergoing SES implantation (target lesion failure: 3.2% vs 4.1%; P = 0.03, target vessel failure: 3.7% vs 5.0%; P = 0.003, patient-oriented composite endpoint 5.7% vs 6.8%; P = 0.03). No significant differences between SES and BES were observed in all-cause death (2.0% vs 1.6%; P = 0.19), cardiac death (1.2% vs 1.2%; P = 0.76) or stent thrombosis (0.6% vs 0.8%; P = 0.43). CONCLUSIONS: These findings suggest an improved clinical safety and efficacy of a newer generation thin-strut SES as compared with a second-generation thicker strut BES.


Assuntos
Ligas de Cromo/farmacologia , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Complicações Pós-Operatórias , Sirolimo/análogos & derivados , Sirolimo/farmacologia , Idoso , Materiais Biocompatíveis/farmacologia , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Stents Farmacológicos/efeitos adversos , Stents Farmacológicos/classificação , Análise de Falha de Equipamento , Feminino , Humanos , Imunossupressores/farmacologia , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Sistema de Registros/estatística & dados numéricos , Análise de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA