Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Lymphat Res Biol ; 18(2): 166-173, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31483190

RESUMO

Background: Surgical excision and/or radiation targeting of regional lymph nodes are an essential component in the clinical management of cancer. Importantly, a more accurate understanding of lymphatic anatomy could enable refinement of present treatment strategies. Given the spatial resolution limitations of contemporary imaging methods, our group sought to utilize noncontrast-enhanced microcomputed tomography (µCT) imaging to clarify regional lymphatic anatomy. Methods and Results: This study was conducted with embalmed en bloc lymphatic tissue packets from six donors (three females and three males: medianage of death = 78 years). All specimens were investigated with noncontrast-enhanced µCT imaging using a conebeam-CT imaging system. Adipose and lymphatic tissues were segmented by radiodensity based on sampling regions of interest. To confirm the observations from µCT, lymph nodes from each packet were exposed to hematoxylin and eosin staining and anti-D240 immunostaining. Following µCT imaging, mean peak radiodensities of -203.14 ± 19.35 Hounsfield units (HU) and 37.25 ± 31.95 HU were revealed for adipose and lymphatic tissues, respectively (p < 0.01). By analyzing histograms of the radiodensity distributions, we determined a threshold of -82.42 HU to differentiate adipose and lymphatic tissue, to generate three-dimensional renderings, and to calculate quantitative metrics. On average, adipose tissue comprised 9.62 ± 3.60 cm3 (73.6%) of the total packet volume, whereas lymphatic tissue comprised 3.47 ± 2.71 cm3 (26.4%). Moreover, each en bloc packet contained four small lymph nodes (1-5 mm) and three to four large lymph nodes (>5 mm). Histology corroborated the observations from µCT. Conclusions: Altogether, a precise understanding of regional lymphatic anatomy elucidated by the present imaging modality may help refine clinical cancer treatment strategies.


Assuntos
Linfonodos , Vasos Linfáticos , Microtomografia por Raio-X , Idoso , Feminino , Humanos , Linfonodos/diagnóstico por imagem , Vasos Linfáticos/diagnóstico por imagem , Masculino
2.
J Orthop Res ; 37(3): 717-726, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30756413

RESUMO

Diffuse idiopathic skeletal hyperostosis (DISH) is a non-inflammatory spondyloarthropathy identified radiographically by calcification of the ligaments and/or entheses along the anterolateral aspect of the vertebral column. The etiology and pathogenesis of calcifications are unknown, and the diagnosis of DISH is currently based on radiographic criteria associated with advanced disease. To characterize the features of calcifications associated with DISH, we used micro-computed tomographic imaging to evaluate a cohort of 19 human cadaveric vertebral columns. Fifty-three percent of the cohort (n = 10; 3 females, 7 males, mean age of death = 81 years, range 67-94) met the radiographic criteria for DISH, with calcification of four or more contiguous vertebral segments. In almost all cases, the lower thoracic regions (T8-12) were affected by calcifications, consisting primarily of large, horizontal outgrowths of bony material. In contrast, calcifications localized to the upper thoracic regions demonstrated variability in their presentation and were categorized as either "continuous vertical bands" or "discontinuous-patchy" lesions. In addition to the variable morphology of the calcifications, our analysis demonstrated remarkable heterogeneity in the densities of calcifications, ranging from internal components below the density of cortical bone to regions of hyper-dense material that exceeded cortical bone. These findings establish that the current radiographic criteria for DISH capture heterogeneous presentations of ectopic spine calcification that can be differentiated based on morphology and density. These findings may indicate a naturally heterogenous disease, potential stage(s) in the natural progression of DISH, or distinct pathologies of ectopic calcifications. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.


Assuntos
Hiperostose Esquelética Difusa Idiopática/diagnóstico por imagem , Vértebras Torácicas/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Calcinose/classificação , Calcinose/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Masculino , Microtomografia por Raio-X
3.
Bone ; 48(3): 639-46, 2011 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-21094285

RESUMO

AIM OF STUDY: To investigate the role of intra-osseous lesions in advancing the pathogenesis of Osteoarthritis (OA) of the knee, using Finite Element Modeling (FEM) in conjunction with high-resolution imaging techniques. METHODS: Twenty early stage OA patients (≤ Grade 2 radiographic score) were scanned with a prototype, cone-beam CT system. Scans encompassed the mid-shaft of the femur to the diaphysis of the proximal tibia. Individual bones were segmented to create 3D geometric models that were transferred to FE software for loading experiments. Patient-specific, inhomogeneous material properties were derived from the CT images and mapped directly to the FE models. Duplicate models were also created, with a 3D sphere (range 3-12 mm) introduced into a weight-bearing region of the joint, mimicking the size, location, and composition of a subchondral bone cyst (SBC). A spherical shell extending 1mm radially around the SBC served as the sample volume for measurements of von Mises equivalent stress. Both models were vertically loaded with 750 N, or approximately 1 body weight during a single-leg stance. RESULTS: All FE models exhibited a physiologically realistic weight-bearing distribution of stress, which initiated at the joint surface and extended to the cortical bone. Models that contained the SBC experienced a nearly two-fold increase in stress (0.934 ± 0.073 and 1.69 ± 0.159 MPa, for the non-SBC and SBC models, respectively) within the bone adjacent to the SBC. In addition, there was a positive correlation found between the diameter of the SBC and the resultant intra-osseous stress under load (p = 0.004). CONCLUSIONS: Our results provide insights into the mechanism by which SBC may accelerate OA, leading to greater pain and disability. Based on these findings, we feel that patient-derived FE models of the OA knee - utilizing in vivo imaging data - present a tremendous potential for monitoring joint mechanics under physiological loads.


Assuntos
Cistos Ósseos/complicações , Cistos Ósseos/patologia , Osso e Ossos/patologia , Análise de Elementos Finitos , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/patologia , Estresse Fisiológico , Cistos Ósseos/fisiopatologia , Osso e Ossos/fisiopatologia , Fêmur/patologia , Fêmur/fisiopatologia , Humanos , Modelos Lineares , Modelos Biológicos , Osteoartrite do Joelho/fisiopatologia , Tíbia/patologia , Tíbia/fisiopatologia , Suporte de Carga/fisiologia
4.
Med Phys ; 36(1): 190-200, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19235387

RESUMO

The role of imaging and image guidance is increasing in surgery and therapy, including treatment planning and follow-up. Fluoroscopy is used for two-dimensional (2D) guidance or localization; however, many procedures would benefit from three-dimensional (3D) guidance or localization. Three-dimensional computed tomography (CT) using a C-arm mounted x-ray image intensifier (XRII) can provide high-quality 3D images; however, patient dose and the required acquisition time restrict the number of 3D images that can be obtained. C-arm based 3D CT is therefore limited in applications for x-ray based image guidance or dynamic evaluations. 2D-3D model-based registration, using a single-plane 2D digital radiographic system, does allow for rapid 3D localization. It is our goal to investigate-over a clinically practical range-the impact of x-ray exposure on the resulting range of 3D localization precision. In this paper it is assumed that the tracked instrument incorporates a rigidly attached 3D object with a known configuration of markers. A 2D image is obtained by a digital fluoroscopic x-ray system and corrected for XRII distortions (+/- 0.035 mm) and mechanical C-arm shift (+/- 0.080 mm). A least-square projection-Procrustes analysis is then used to calculate the 3D position using the measured 2D marker locations. The effect of x-ray exposure on the precision of 2D marker localization and on 3D object localization was investigated using numerical simulations and x-ray experiments. The results show a nearly linear relationship between 2D marker localization precision and the 3D localization precision. However, a significant amplification of error, nonuniformly distributed among the three major axes, occurs, and that is demonstrated. To obtain a 3D localization error of less than +/- 1.0 mm for an object with 20 mm marker spacing, the 2D localization precision must be better than +/- 0.07 mm. This requirement was met for all investigated nominal x-ray exposures at 28 cm FOV, and for all but the lowest two at 40 cm FOV. However, even for those two nominal exposures, the expected 3D localization error is less than +/- 1.2 mm. The tracking precision was +/- 0.65 mm for the out-of-plane translations, +/- 0.05 mm for in-plane translations, and +/- 0.05 degrees for the rotations. The root mean square (RMS) difference between the true and projection-Procrustes calculated location was 1.07 mm. It is believed these results show the potential of this technique for dynamic evaluations or real-time image guidance using a single x-ray source and XRII detector.


Assuntos
Algoritmos , Fluoroscopia/métodos , Imageamento Tridimensional/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Med Phys ; 32(1): 55-64, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15719955

RESUMO

X-ray image intensifier (XRII) geometric distortion reduces the accuracy of image-guided procedures and quantitative image reconstructions. Due to the dependence of this error on the earth's magnetic field, the required correction is angle dependent, and calibration data should ideally be acquired simultaneously with clinical image data, at a specific orientation. We describe a technique to correct XRII geometric image distortion at any angular position during a stereotactic procedure. This approach uses a machined plastic grid, which contains channels that can be filled with iodinated contrast agent and subsequently flushed with water, providing contrast and mask images, respectively, of a geometric calibration grid. The standard image subtraction capabilities of conventional digital subtraction angiography devices can then be used to create a subtraction image of the iodine-filled channels, without any confounding anatomical structure. Grid-line intersection points are used to determine the control points that are required for a global polynomial correction algorithm, creating a correction map that is specific to the current angular position and XRII field of view (FOV). Tests with a clinical C-arm based XRII show that control points can be obtained with a precision of +/-0.053 mm, resulting in geometric correction accuracy of +/-0.152 mm, at a nominal FOV of 40 cm. While the precision and accuracy are both poorer than that achieved with a high-contrast steel-bead grid, the fact that the liquid grid can remain rigidly attached to the XRII during an entire procedure results in the establishment of an absolute detector coordinate system (referenced to the liquid-filled correction grid). The design of the liquid-filled channels allows the required control points to be introduced into the image or removed in about 30 s, avoiding the appearance of obscuring or confounding markers during clinical image acquisition, with a concurrent increase in patient dose of about 8% in the current design. Applications for this technique include stereotactic surgery, radiosurgery, x-ray stereogrammetry, and other image-guided procedures.


Assuntos
Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Intensificação de Imagem Radiográfica/métodos , Radiocirurgia/métodos , Algoritmos , Calibragem , Meios de Contraste/farmacologia , Humanos , Iodo , Magnetismo , Modelos Teóricos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Crânio/patologia , Crânio/efeitos da radiação , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA