Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
2.
Int J Cardiol ; 337: 29-37, 2021 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-34029618

RESUMO

INTRODUCTION: Refractory angina (RA) is considered the end-stage of coronary artery disease, and often has no interventional treatment options. Coronary sinus Reducer (CSR) is a recent addition to the therapeutic arsenal, but its efficacy has only been evaluated on small populations. The RESOURCE registry provides further insights into this therapy. METHODS: The RESOURCE is an observational, retrospective registry that includes 658 patients with RA from 20 centers in Europe, United Kingdom and Israel. Prespecified endpoints were the amelioration of anginal symptoms evaluated with the Canadian Cardiovascular Society (CCS) score, the rates of procedural success and complications, and MACEs as composite of all-cause mortality, acute coronary syndromes, and stroke. RESULTS: At a median follow-up of 502 days (IQR 225-1091) after CSR implantation, 39.7% of patients improved by ≥2 CCS classes (primary endpoint), and 76% by ≥1 class. Procedural success was achieved in 96.7% of attempts, with 3% of procedures aborted mostly for unsuitable coronary sinus anatomy. Any complication occurred in 5.7% of procedures, but never required bailout surgery nor resulted in intra- or periprocedural death or myocardial infarction. One patient developed periprocedural stroke after inadvertent carotid artery puncture. At the last available follow-up, overall mortality and MACE were 10.4% and 14.6% respectively. At one, three and five years, mortality rate at Kaplan-Meier analysis was 4%, 13.7%, and 23.4% respectively. CONCLUSIONS: CSR implantation is safe and reduces angina in patients with refractory angina.


Assuntos
Seio Coronário , Canadá , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Europa (Continente)/epidemiologia , Humanos , Israel , Estudos Retrospectivos , Resultado do Tratamento , Reino Unido/epidemiologia
3.
Atherosclerosis ; 328: 136-143, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33883086

RESUMO

BACKGROUND AND AIMS: The potential impact of coronary atherosclerosis, as detected by coronary artery calcium, on clinical outcomes in COVID-19 patients remains unsettled. We aimed to evaluate the prognostic impact of clinical and subclinical coronary artery disease (CAD), as assessed by coronary artery calcium score (CAC), in a large, unselected population of hospitalized COVID-19 patients undergoing non-gated chest computed tomography (CT) for clinical practice. METHODS: SARS-CoV 2 positive patients from the multicenter (16 Italian hospitals), retrospective observational SCORE COVID-19 (calcium score for COVID-19 Risk Evaluation) registry were stratified in three groups: (a) "clinical CAD" (prior revascularization history), (b) "subclinical CAD" (CAC >0), (c) "No CAD" (CAC = 0). Primary endpoint was in-hospital mortality and the secondary endpoint was a composite of myocardial infarction and cerebrovascular accident (MI/CVA). RESULTS: Amongst 1625 patients (male 67.2%, median age 69 [interquartile range 58-77] years), 31%, 57.8% and 11.1% had no, subclinical and clinical CAD, respectively. Increasing rates of in-hospital mortality (11.3% vs. 27.3% vs. 39.8%, p < 0.001) and MI/CVA events (2.3% vs. 3.8% vs. 11.9%, p < 0.001) were observed for patients with no CAD vs. subclinical CAD vs clinical CAD, respectively. The association with in-hospital mortality was independent of in-study outcome predictors (age, peripheral artery disease, active cancer, hemoglobin, C-reactive protein, LDH, aerated lung volume): subclinical CAD vs. No CAD: adjusted hazard ratio (adj-HR) 2.86 (95% confidence interval [CI] 1.14-7.17, p=0.025); clinical CAD vs. No CAD: adj-HR 3.74 (95% CI 1.21-11.60, p=0.022). Among patients with subclinical CAD, increasing CAC burden was associated with higher rates of in-hospital mortality (20.5% vs. 27.9% vs. 38.7% for patients with CAC score thresholds≤100, 101-400 and > 400, respectively, p < 0.001). The adj-HR per 50 points increase in CAC score 1.007 (95%CI 1.001-1.013, p=0.016). Cardiovascular risk factors were not independent predictors of in-hospital mortality when CAD presence and extent were taken into account. CONCLUSIONS: The presence and extent of CAD are associated with in-hospital mortality and MI/CVA among hospitalized patients with COVID-19 disease and they appear to be a better prognostic gauge as compared to a clinical cardiovascular risk assessment.


Assuntos
COVID-19 , Doença da Artéria Coronariana , Idoso , Cálcio , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , SARS-CoV-2
4.
Catheter Cardiovasc Interv ; 98(3): 595-604, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33586278

RESUMO

BACKGROUND: Valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) is an emerging alternative to re-do surgery. However, the challenge of coronary access (CA) following ViV-TAVR is a potential limitation as TAVR expands to younger lower-risk populations. OBJECTIVES: Using post-implantation computed tomography (CT) scans to evaluate the geometrical relationship between coronary ostia and valve frame in patients undergoing ViV-TAVR with the ACURATE neo valve. METHODS: Post-implant CT scans of 18 out of 20 consecutive patients treated with the ACURATE neo valve were analyzed. Coronary ostia location in relation to the highest plane (HP) (highest point of the ACURATE neo or surgical valve) was determined. Ostia located below the highest plan were further subclassified according to the gap available between the transcatheter heart valve frame and ostium (transcatheter-to-coronary [TTC] distance). The impact implantation depth has on these geometrical relationships was evaluated. RESULTS: A total of 21 out of 36 coronary ostia (58%) were located below the level of the HP with the left coronary artery (36%) more likely to be affected than the right (22%). Further sub-classification of these ostia revealed a large (>6 mm), moderate (4-6 mm), and small (<4 mm) TTC distance in 57% (12/21), 38% (8/21), and in 6% (1/18) of cases, respectively. At an implantation depth <4 mm compared to >4 mm, all ostia were located below the HP with no difference in post-procedural mean gradients (14.5 mmHg ± 4.7 vs. 12.6 mmHg ± 5.8; p = .5, 95%CI 3.8-7.5). CONCLUSIONS: CA following ACURATE neo implantation for ViV-TAVR could potentially be challenging in a significant proportion of patients and specific consideration should be given to the implantation depth.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Tomografia , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 97(5): 950-954, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32865314

RESUMO

Aortitis is an uncommon systemic inflammatory disease affecting the aorta and its main branches. Severe aortic regurgitation (AR) represents a fearsome complication of aortitis and is associated with an increased mortality rate. Surgical aortic valve replacement represents the only treatment choice for these patients. However, it is associated with a higher risk of medium to long-term complications such as prosthetic valve detachment. This is the first reported case where severe AR secondary to aortitis was managed with transcatheter aortic valve implantation (TAVI). TAVI was safe and effective in this clinical setting and may be considered a viable alternative to high-risk surgery in these complex patients.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Aortite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Aortite/diagnóstico por imagem , Aortite/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA