Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Endovasc Ther ; 23(2): 297-301, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26868482

RESUMO

PURPOSE: To examine the changes in distraction force following relining of a conventional abdominal aortic stent-graft with a type IIIb endoleak using the Nellix endovascular sealing device compared to a unilateral stent-graft. METHODS: Relining is often used to repair type IIIb endoleaks, but the consequences to graft stability are unknown. A mathematical model was constructed based on pressure and volume flow through the stent-grafts, incorporating recognized distraction force equations. Steady flow was presumed at peak systolic pressures to calculate the maximum distraction force, with gravity ignored. Distraction forces for 28- to 36-mm-diameter stent-graft bodies with 16-mm limbs were calculated and compared to forces following relining with single and double Nellix devices or the Renu unilateral device. RESULTS: Distraction forces for the 28-, 32-, and 36-mm stent-grafts prior to relining were 5.99, 10.21, and 14.99 N, respectively. Similar forces were reported after relining with bilateral Nellix devices (5.86, 10.08, and 14.86 N, respectively). However, use of a unilateral Nellix increased the distraction forces to 9.92, 14.14, and 18.92 N, respectively. These were comparable to the increase observed after relining with a Renu unilateral stent-graft (9.87, 14.09, and 18.86 N, respectively). The proportional increase in distraction force for a unilateral relining ranged from 26% to 66%, with the greatest increase noted in the smaller diameter main bodies. CONCLUSION: Relining a stent-graft with a type IIIb endoleak using bilateral Nellix devices does not increase the distraction force. However, a unilateral Nellix device or the Renu system could theoretically increase the distraction force by up to 66%, potentially risking migration and type Ia endoleak. In clinical practice, these results suggest that a relining with bilateral Nellix may have benefits over the Renu unilateral stent-graft.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Endoleak/cirurgia , Procedimentos Endovasculares/instrumentação , Hemodinâmica , Modelos Cardiovasculares , Stents , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/fisiopatologia , Procedimentos Endovasculares/efeitos adversos , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/fisiopatologia , Humanos , Desenho de Prótese , Fluxo Sanguíneo Regional , Reoperação , Estresse Mecânico , Resultado do Tratamento
2.
J Biomater Appl ; 30(2): 212-20, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25766038

RESUMO

PURPOSE: Developing new blends of heavier-than-water silicone oil tamponade agents containing high molecular weight polydimethylsiloxane polymer for use in vitreoretinal surgery. MATERIALS AND METHODS: The viscoelastic properties of heavier-than-water silicone oil blends (30.5% F6H8 + 69.5% polydimethylsiloxane) containing high molecular weight polymer additive at increasing concentrations were measured using a controlled-stress rheometer (TA Instruments Rheolyst AR 1000 N). Emulsification of the blends was induced using a sonication device and a pluronic surfactant as a strong emulsifier. The percentage emulsion area was photographed and measured using ImageJ software. In a second in vitro emulsification assessment, silicone oil blends were dispersed using a high shear homogenizer and the oil-in-water droplets were counted using a coulter counter particle analyser. RESULTS: The addition of the high molecular weight polymer increased shear viscosity and viscoelasticity of the oil blends, which were measureable and to some extent predictable. The in vitro emulsification models produced contradictory results. This demonstrates the difficulty of designing and using in vitro models to evaluate the emulsification tendency of tamponade agents in vivo. CONCLUSION: Addition of a high molecular weight polymer to heavy silicone oil can increase the viscoelasticity. These findings might contribute to the development of emulsification resistant heavy silicone oils.


Assuntos
Emulsões , Polímeros/química , Óleos de Silicone/química , Peso Molecular , Reologia , Água/química
3.
J Vasc Surg ; 60(6): 1648-56.e1, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25454107

RESUMO

OBJECTIVE: Secure fixation of endovascular stent grafts is essential for successful endovascular aneurysm repair. Hemodynamic distraction forces are generated by blood pressure and blood flow and act against fixation force to encourage migration that may eventually lead to late stent graft failure. The aim of this in silico study was to determine which morphologic features were associated with greater distraction force. METHODS: Computer models of 54 in situ fenestrated stent grafts were constructed from postoperative computed tomography scans by use of image processing software. Computational fluid dynamic analysis was then performed by use of a commercial finite volume solver with boundary conditions representative of peak systole. Distraction force results were obtained for each component of the stent graft. Distraction force was correlated with lumen cross-sectional area (XSA) at the inlet and outlet of components and was compared between groups of components, depending on the magnitude of four predefined angles within the aortoiliac territory that we describe in detail. RESULTS: Median total resultant distraction force (RDF) acting on the fenestrated proximal bodies was 4.8 N (1.3-15.7 N); bifurcated distal bodies, 5.6N (1.0-8.0 N); and limb extensions, 1.7 N (0.6-8.4N). Inlet XSA exhibited strong, positive correlation with total RDF in proximal body and distal body components (Spearman correlation coefficient ρ, 0.883 and 0.802, respectively). Outlet XSA exhibited a similarly strong, positive correlation with total RDF in limb extension components (ρ, 0.822). Outlet angulation ≥ 45 degrees was associated with greater total RDF in the limb extension components only (P = .004). CONCLUSIONS: For a given blood pressure, XSA was the most important morphologic determinant of total RDF. Angulation within the aorta was not large enough to influence this, whereas iliac angulation affecting outlet angulation of limb extension components was associated with significantly greater total RDF.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Simulação por Computador , Procedimentos Endovasculares/instrumentação , Hemodinâmica , Modelos Cardiovasculares , Stents , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia/métodos , Pressão Arterial , Velocidade do Fluxo Sanguíneo , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/fisiopatologia , Humanos , Desenho de Prótese , Falha de Prótese , Estresse Mecânico , Tomografia Computadorizada por Raios X , Resultado do Tratamento
4.
J Vasc Surg ; 60(2): 418-27, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24657293

RESUMO

BACKGROUND: Meta-analysis supports patch angioplasty after carotid endarterectomy (CEA); however, studies indicate considerable variation in practice. The hemodynamic effect of a patch is unclear and this study attempted to elucidate this and guide patch width selection. METHODS: Four groups were selected: healthy volunteers and patients undergoing CEA with primary closure, trimmed patch (5 mm), or 8-mm patch angioplasty. Computer-generated three-dimensional models of carotid bifurcations were produced from transverse ultrasound images recorded at 1-mm intervals. Rapid prototyping generated models for flow visualization studies. Computational fluid dynamic studies were performed for each model and validated by flow visualization. Mean wall shear stress (WSS) and oscillatory shear index (OSI) maps were created for each model using pulsatile inflow at 300 mL/min. WSS of <0.4 Pa and OSI >0.3 were considered pathological, predisposing to accretion of intimal hyperplasia. The resultant WSS and OSI maps were compared. RESULTS: The four groups comprised 8 normal carotid arteries, 6 primary closures, 6 trimmed patches, and seven 8-mm patches. Flow visualization identified flow separation and recirculation at the bifurcation increased with a patch and was related to the patch width. Computational fluid dynamic identified that primary closure had the fewest areas of low WSS or elevated OSI but did have mild common carotid artery stenoses at the proximal arteriotomy that caused turbulence. Trimmed patches had more regions of abnormal WSS and OSI at the bifurcation, but 8-mm patches had the largest areas of deleteriously low WSS and high OSI. Qualitative comparison among the four groups confirmed that incorporation of a patch increased areas of low WSS and high OSI at the bifurcation and that this was related to patch width. CONCLUSIONS: Closure technique after CEA influences the hemodynamic profile. Patching does not appear to generate favorable flow dynamics. However, a trimmed 5-mm patch may offer hemodynamic benefits over an 8-mm patch and may be the preferred option.


Assuntos
Angioplastia , Artérias Carótidas/cirurgia , Doenças das Artérias Carótidas/cirurgia , Endarterectomia das Carótidas , Hemodinâmica , Técnicas de Fechamento de Ferimentos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia/efeitos adversos , Angioplastia/instrumentação , Velocidade do Fluxo Sanguíneo , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiopatologia , Doenças das Artérias Carótidas/diagnóstico , Doenças das Artérias Carótidas/fisiopatologia , Simulação por Computador , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Fluxo Pulsátil , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Estresse Mecânico , Resultado do Tratamento , Ultrassonografia , Técnicas de Fechamento de Ferimentos/efeitos adversos
5.
Interact Cardiovasc Thorac Surg ; 16(5): 583-8, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23407695

RESUMO

OBJECTIVES: Aortic replacement is based on the aortic diameter in the absence of dissection or connective tissue diseases. Frequently, a number of different aortic-to-prosthetic anastomotic positions are possible depending on patient factors and surgeon preferences. High stress on residual aortic tissue may result in aneurysm formation or aneurysmal dilatation. Utilizing a computational fluid dynamic evaluation, we aimed to define possible optimal operative interventions with regard to the extent of aortic replacement. METHODS: For proof of principle, a computational fluid dynamic (CFD) analysis, using Fluent 6.2 (Ansys UK Ltd, Sheffield, UK), was performed on a simplified ascending arch and descending aortic geometry. Wall shear stress in three dimensions was assessed for the standard operations: ascending aortic replacement, arch replacement and proximal descending aortic replacement. RESULTS: Hermiarch replacement is superior to isolated ascending aortic replacement with regard to residual stress analysis on tissues (up to a 10-fold reduction). Aortic arch replacement with island implantation of the supra-aortic vessels may potentially result in high stress on the residual aorta (10-fold increase). Aortic arch replacement with individual supra-aortic vessel implantation may result in areas of high stress (10-fold increase) on native vessels if an inadequate length of supra-aortic tissue is not resected, regardless of it being aneurysmal. CONCLUSIONS: Computational fluid dynamic evaluation, which will have to be patient-specific, 3D anatomical and physiological, potentially has enormous implications for operative strategy in aortic replacement surgery. CFD analysis may direct the replacement of normal-diameter aortas in the future.


Assuntos
Aorta/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Simulação por Computador , Modelos Cardiovasculares , Cirurgia Assistida por Computador , Aorta/patologia , Aorta/fisiopatologia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aorta Torácica/cirurgia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/fisiopatologia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Hemodinâmica , Humanos , Imageamento Tridimensional , Desenho de Prótese , Interpretação de Imagem Radiográfica Assistida por Computador , Estresse Mecânico , Cirurgia Assistida por Computador/efeitos adversos , Cirurgia Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X
6.
Eur J Cardiothorac Surg ; 33(6): 995-1001, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18434179

RESUMO

OBJECTIVE: To develop a mathematical model to demonstrate that ascending aortic curvature is an independent risk factor for type A dissections, in addition to hypertension, bicuspid aortic valve, aneurysm of ascending aorta, and intrinsic aortic tissue abnormalities, like Marfan's syndrome. METHODS: A steady state one-dimensional flow analysis was performed, utilising Newton's third law of motion. Five different clinical scenarios were evaluated: (1) effect of aortic curvature; (2) effect of beta-blockers, (3) effect of patient size, (4) forces on a Marfan's aorta, and (5) site of entry flap in aortic dissection. RESULTS: Aortic curvature increases the forces exerted on the ascending aorta by a factor of over 10-fold. Aortic curvature can cause patients with a systolic blood pressure of 8 0mmHg to have greater forces exerted on their aorta despite smaller diameters and lower cardiac outputs, than patients with systolic blood pressures of 120 mmHg. In normal diameter aortas, beta-blockers have minimal effect compared with aortic curvature. Aortic curvature may help to explain why normal diameter aortas can dissect, and also that the point of the entry tear may be potentially predictable. Aortic curvature has major effects on the forces exerted on the aorta in patients with Marfan's syndrome. CONCLUSIONS: Aortic curvature is relatively more important that aortic diameter, blood pressure, cardiac output, beta-blocker use, and patient size with regard to the force acting on the aortic wall. This may explain why some patients with normal diameter ascending aortas with or without Marfan's syndrome develop type A dissections and aneurysms. Aortic curvature may also help to explain the site of entry tear in acute type A dissection. Further clinical study is needed to validate this study's finding.


Assuntos
Aneurisma Aórtico/etiologia , Aneurisma Aórtico/patologia , Dissecção Aórtica/etiologia , Dissecção Aórtica/patologia , Modelos Cardiovasculares , Antagonistas Adrenérgicos beta/farmacologia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/fisiopatologia , Aorta/efeitos dos fármacos , Aorta/fisiopatologia , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/fisiopatologia , Aortografia , Pressão Sanguínea , Peso Corporal , Débito Cardíaco , Hemorreologia , Humanos , Síndrome de Marfan/fisiopatologia , Fatores de Risco , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA