Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Bone Joint Surg Am ; 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38753809

RESUMO

BACKGROUND: The International Consensus Meeting on Venous Thromboembolism (ICM-VTE) in 2022 proclaimed low-dose aspirin as the most effective agent in patients across all risk profiles undergoing joint arthroplasty. However, data on large patient populations assessing trends in chemoprophylactic choices and related outcomes following total knee arthroplasty (TKA) remain scant. The present study was designed to characterize the clinical use of various chemoprophylactic agents in patients undergoing TKA and to determine the efficacy of aspirin compared with other agents in patient groups stratified by VTE risk profiles. METHODS: This study utilized a national database to determine the proportion of patients undergoing TKA who received low-dose aspirin versus other chemoprophylaxis between 2012 and 2022. VTE risk profiles were determined on the basis of comorbidities established in the ICM-VTE. The odds ratios (ORs) and 95% confidence intervals (CIs) between various classes of thromboprophylaxis in patients with high and low risk of VTE were calculated. The odds of deep-vein thrombosis (DVT), pulmonary embolus (PE), bleeding events, infections, mortality, and hospitalizations were also assessed in the 90-day postoperative period for propensity-matched cohorts receiving low-dose (81 mg) aspirin only versus other prophylaxis, segregating patients by VTE risk profile. RESULTS: A total of 126,692 patients undergoing TKA across 60 health-care organizations were included. The proportion of patients receiving low-dose aspirin increased from 7.65% to 55.29% between 2012 and 2022, whereas the proportion of patients receiving other chemoprophylaxis decreased from 96.25% to 42.98%. Low-dose-aspirin-only use increased to approximately 50% in both high-risk and low-risk populations but was more likely in low-risk populations (OR, 1.17; 95% CI, 1.15 to 1.20) relative to high-risk populations. Both low-risk and high-risk patients in the low-dose-aspirin-only cohorts had decreased odds of DVT, PE, bleeding, infections, and hospitalizations compared with other prophylaxis regimens. CONCLUSIONS: The findings of the present study on a very large population of patients undergoing TKA support the recent ICM-VTE statement by showing that low-dose aspirin is a safe and effective method of prophylaxis in patients across various risk profiles. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

2.
J Robot Surg ; 18(1): 160, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38578350

RESUMO

Robotic assisted (RA) total hip arthroplasty (THA) offers improved acetabular component placement and radiographic outcomes, but inconsistent assessment methods of its learning curves render the evaluation of adopting novel platforms challenging. Therefore, we conducted a systematic review to assess the learning curve associated with RA-THA, both tracking a surgeon's performance across initial cases and comparing their performance to manual THA (M-THA). PubMed, MEDLINE, EBSCOhost, and Google Scholar were searched on June 16, 2023, to identify studies published between January 1, 2000 and June 16, 2023 (PROSPERO registration: CRD42023437339). The query yielded 655 unique articles, which were screened for eligibility. The final analysis included 11 articles, evaluating 1351 THA procedures. Risk of bias was assessed via the Methodological Index for Nonrandomized Studies (MINORS) tool. The mean MINORS score was 21.3 ± 0.9. RA-THA provided immediate improvements in acetabular component placement accuracy and radiographic outcomes compared to M-THA, with little to no experience required to achieve peak proficiency. A modest learning curve (12-17 cases) was associated with operative time, which was elevated compared to M-THA (+ 9-13 min). RA-THA offers immediate advantages to M-THA for component placement accuracy and radiographic outcomes. Surgeons should expect to experience increased operative times, which become less pronounced or equivalent to M-THA after a modest caseload.


Assuntos
Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Humanos , Artroplastia de Quadril/métodos , Curva de Aprendizado , Procedimentos Cirúrgicos Robóticos/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Cirurgia Assistida por Computador/métodos
3.
J Orthop ; 53: 125-132, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38515529

RESUMO

Introduction: Robotic-assisted (RA) and computer-navigated (CN) total hip arthroplasty (THA) have been demonstrated to improve component placement accuracy compared to manual THA (mTHA) for primary osteoarthritis. As hip dysplasia presents several additional challenges in component placement accuracy and leg length discrepancy (LLD) correction during THA, a systematic review was conducted to evaluate whether utilizing these platforms may be associated with superior outcomes over mTHA in patients who have hip dysplasia. Methods: PubMed, Medline, EBSCOhost, and Google Scholar were searched on September 13, 2023 to identify comparative studies published after January 1, 2000 that evaluated outcomes of RA-THA or CN-THA in patients who have hip dysplasia. The query yielded 197 unique articles, which were screened for alignment with the study aims. After screening, 10 studies fulfilled all inclusion criteria, comprising 946 patients. Risk of bias was evaluated via the Methodological Index for Nonrandomized Studies tool, and the mean score was 21.2 ± 1.5. Results: Both RA-THA and CN-THA were not associated with improved acetabular anteversion and inclination when evaluating Crowe I-IV types altogether compared to mTHA, but studies reported improved accuracy for each Crowe I and II cases when assessed individually. While studies reporting acetabular cup placement within the Lewinnek and Callanan safe zones consistently found higher odds of accurate positioning for RA-THA versus mTHA, accuracy in achieving targeted center of rotation was mixed. Also, studies reported no difference in LLD restoration for RA-THA and CN-THA compared to mTHA. While operative time may be increased when utilizing these platforms, they may also expedite specific sequences, offsetting most of the increase in operative time. Conclusion: This review highlights the advantages of RA-THA and CN-THA for patients who have DDH, particularly when treating Crowe I and II types as superior radiographic outcomes were achieved with these intraoperative technologies. However, there remains a need for studies to investigate whether this results in patient-reported outcome measures.

4.
J Robot Surg ; 18(1): 104, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38430388

RESUMO

PURPOSE: Computer-navigated (CN) total hip arthroplasty (THA) offers improved acetabular component placement and radiographic outcomes, but inconsistent assessment methods of its learning curves render the evaluation of adopting a novel platform challenging. Therefore, we conducted a systematic review to assess the learning curve associated with CN-THA, both tracking a surgeon's performance across initial cases and comparing their performance to manual THA (M-THA). METHODS: A search was conducted using PubMed, MEDLINE, EBSCOhost, and Google Scholar on June 16, 2023 to find research articles published after January 1, 2000 (PROSPERO registration: CRD4202339403) that investigated the learning curve associated with CN-THA. 655 distinct articles were retrieved and subsequently screened for eligibility. In the final analysis, nine publications totaling 847 THAs were evaluated. The Methodological Index for Nonrandomized Studies (MINORS) tool was utilized to evaluate the potential for bias, with the mean MINORS score of 21.3 ± 1.2. RESULTS: CN-THA showed early advantages to M-THA for component placement accuracy and radiographic outcomes but longer operative times (+ 3- 20 min). There was a learning curve required to achieve peak proficiency in these metrics, though mixed methodologies made the required caseload unclear. CONCLUSIONS: CN-THA offers immediate advantages to M-THA for component placement accuracy and radiographic outcomes, though CN-THA's advantages become more pronounced with experience. Surgeons should anticipate longer operative times during the learning curve for CN-THA, which lessen following a modest caseload. A more thorough evaluation of novel computer-navigated technologies would be enhanced by adopting a more uniform method of defining learning curves for outcomes of interest. Registration PROSPERO registration of the study protocol: CRD42023394031, 27 June 2023.


Assuntos
Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia de Quadril/métodos , Curva de Aprendizado , Procedimentos Cirúrgicos Robóticos/métodos , Resultado do Tratamento , Computadores
5.
Arch Orthop Trauma Surg ; 144(5): 1977-1987, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38554209

RESUMO

INTRODUCTION: Prior studies investigating the racial and ethnic representation of orthopedic trial participants have found low rates of reporting, but these studies are dated due to the passing of the National Institutes of Health Final Rule in 2017 requiring the reporting of racial and ethnic data among clinical trials. Therefore, we evaluated the representativeness of orthopedic clinical trials before and after the Final Rule. METHODS: A cross-sectional survey of orthopaedic clinical trials registered at ClinicalTrials.gov between October 1, 2007 and May 20, 2023 was conducted. After identifying and screening 23,752 clinical trials, 1564 trials were included in the analysis. Trials started before the implementation of the Final Rule on January 18, 2017 were grouped and compared to trials that began after. Odds ratios (OR) were utilized to identify trial characteristics associated with reporting race/ethnicity data. One-proportion z tests compared the representation of each racial and ethnic category to the 2020 United States Census. RESULTS: In total, 34% (544 of 1564) of orthopedic clinical trials evaluated reported the race of participants, while 28% (438 of 1564) reported ethnicity. Trials registered after the Final Rule were more likely to report racial (OR: 5.15, 95%CI: 3.72-7.13, p < 0.001) and ethnic (OR: 3.23, 95%CI: 2.41-4.33, p < 0.001) representation of participants. Compared with the distribution of race and ethnicity reported by the United States 2020 Census, orthopedic trials had 16.6% more White participants (95% CI 16.4%, 16.8%; p < 0.001), 3.2% fewer Black participants (95%CI 3.1%, 3.3%; p < 0.001), and 5.7% fewer Hispanic/Latino participants (95%CI 5.2%, 6.2%; p < 0.001). Trials with enrollment sizes over 100 participants were also more likely to report race and ethnicity, with odds increasing with increased sample size. CONCLUSIONS: The Final Rule marginally improved the reporting of race and ethnicity in orthopedic clinical trials, and underrepresentation of Black or African American, Multiracial, and Hispanic populations persists. LEVEL OF EVIDENCE: III.


Assuntos
Ensaios Clínicos como Assunto , Etnicidade , Procedimentos Ortopédicos , Grupos Raciais , Humanos , Estudos Transversais , Ensaios Clínicos como Assunto/estatística & dados numéricos , Estados Unidos , Grupos Raciais/estatística & dados numéricos , Etnicidade/estatística & dados numéricos , Procedimentos Ortopédicos/estatística & dados numéricos , Ortopedia/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA