Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
BMC Cancer ; 19(1): 428, 2019 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-31072353

RESUMO

BACKGROUND: Colorectal cancer remains the second leading cause of cancer death in the United States, and increased risk in patients with ulcerative colitis (a subset of inflammatory bowel disease) has motivated studies into early markers of dysplasia. The development of clinically translatable multiphoton imaging systems has allowed for the potential of in vivo label-free imaging of epithelial crypt structures via autofluorescence and/or second harmonic generation (SHG). SHG has been used to investigate collagen structures in various types of cancer, though the changes that colorectal epithelial collagen structures undergo during tumor development, specifically colitis-associated tumors, have not been fully investigated. METHODS: This study used two murine models, using A/J mice, one for spontaneous carcinoma and one for colitis-associated carcinoma, to investigate and quantify SHG image features that could potentially inform future study designs of endoscopic multiphoton imaging systems. The spontaneous tumor model comprised a series of six weekly injections of azoxymethane (AOM model). The colitis-associated tumor model comprised a single injection of AOM, followed by cycles of drinking water with dissolved dextran sodium sulfate salt (AOM-DSS model). SHG images of freshly resected murine colon were acquired with a multiphoton imaging system, and image features, such as crypt size, shape and distribution, were quantified using an automated algorithm. RESULTS: The comparison of quantified features of crypt morphology demonstrated the ability of our quantitative image feature algorithms to detect differences between spontaneous (AOM model) and colitis-associated (AOM-DSS model) murine colorectal tissue specimens. There were statistically significant differences in the mean and standard deviation of nearest neighbor (distance between crypts) and circularity between the Control cohort, AOM and AOM-DSS cohorts. We also saw significance between AOM and AOM-DSS cohorts when calculating nearest neighbor in images acquired at fixed depths. CONCLUSION: The results provide insight into the ability of SHG imaging to yield relevant data about the crypt microstructure in colorectal epithelium, specifically the potential to distinguish between spontaneous and colitis-associated murine models using quantification of crypt shape and distribution, informing future design of translational multiphoton imaging systems and protocols.


Assuntos
Colite/patologia , Colo/patologia , Neoplasias do Colo/diagnóstico por imagem , Mucosa Intestinal/patologia , Microscopia de Geração do Segundo Harmônico , Animais , Colite/induzido quimicamente , Colite/diagnóstico por imagem , Colo/diagnóstico por imagem , Neoplasias do Colo/patologia , Sulfato de Dextrana/toxicidade , Modelos Animais de Doenças , Progressão da Doença , Humanos , Mucosa Intestinal/diagnóstico por imagem , Camundongos
2.
J Med Imaging (Bellingham) ; 3(2): 024502, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27335893

RESUMO

Qualitative screening for colorectal polyps via fiber bundle microendoscopy imaging has shown promising results, with studies reporting high rates of sensitivity and specificity, as well as low interobserver variability with trained clinicians. A quantitative image quality control and image feature extraction algorithm (QFEA) was designed to lessen the burden of training and provide objective data for improved clinical efficacy of this method. After a quantitative image quality control step, QFEA extracts field-of-view area, crypt area, crypt circularity, and crypt number per image. To develop and validate this QFEA, a training set of microendoscopy images was collected from freshly resected porcine colon epithelium. The algorithm was then further validated on ex vivo image data collected from eight human subjects, selected from clinically normal appearing regions distant from grossly visible tumor in surgically resected colorectal tissue. QFEA has proven flexible in application to both mosaics and individual images, and its automated crypt detection sensitivity ranges from 71 to 94% despite intensity and contrast variation within the field of view. It also demonstrates the ability to detect and quantify differences in grossly normal regions among different subjects, suggesting the potential efficacy of this approach in detecting occult regions of dysplasia.

3.
Proc SPIE Int Soc Opt Eng ; 97122016 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-27134336

RESUMO

Two-photon excitation of label-free tissue is of increasing interest, as advances have been made in endoscopic clinical application of multiphoton microscopy, such as second harmonic generation (SHG) scanning endoscopy used to monitor cervical collagen in mice1. We used C57BL mice as a model to investigate the progression of gastrointestinal structures, specifically glandular area and circularity. We used multiphoton microscopy to image ex-vivo label-free murine colon, focusing on the collagen structure changes over time, in mice ranging from 10 to 20 weeks of age. Series of images were acquired within the colonic and intestinal tissue at depth intervals of 20 microns from muscularis to the epithelium, up to a maximum depth of 180 microns. The imaging system comprised a two-photon laser tuned to 800nm wavelength excitation, and the SHG emission was filtered with a 400/40 bandpass filter before reaching the photomultiplier tube. Images were acquired at 15 frames per second, for 200 to 300 cumulative frames, with a field of view of 261um by 261um, and 40mW at sample. Image series were compared to histopathology H&E slides taken from adjacent locations. Quantitative metrics for determining differences between murine glandular structures were applied, specifically glandular area and circularity.

4.
PLoS One ; 10(5): e0125598, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25962131

RESUMO

Proflavine hemisulfate, an acridine-derived fluorescent dye, can be used as a rapid stain for cytologic examination of biological specimens. Proflavine fluorescently stains cell nuclei and cytoplasmic structures, owing to its small amphipathic structure and ability to intercalate DNA. In this manuscript, we demonstrated the use of proflavine as a rapid cytologic dye on a number of specimens, including normal exfoliated oral squamous cells, cultured human oral squamous carcinoma cells, and leukocytes derived from whole blood specimens using a custom-built, portable, LED-illuminated fluorescence microscope. No incubation time was needed after suspending cells in 0.01% (w/v) proflavine diluted in saline. Images of proflavine stained oral cells had clearly visible nuclei as well as granular cytoplasm, while stained leukocytes exhibited bright nuclei, and highlighted the multilobar nature of nuclei in neutrophils. We also demonstrated the utility of quantitative analysis of digital images of proflavine stained cells, which can be used to detect significant morphological differences between different cell types. Proflavine stained oral cells have well-defined nuclei and cell membranes which allowed for quantitative analysis of nuclear to cytoplasmic ratios, as well as image texture analysis to extract quantitative image features.


Assuntos
Meios de Contraste , Corantes Fluorescentes , Teste de Papanicolaou/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Proflavina , Linhagem Celular Tumoral , Humanos , Microscopia de Fluorescência/instrumentação , Microscopia de Fluorescência/métodos , Teste de Papanicolaou/instrumentação
5.
Proc SPIE Int Soc Opt Eng ; 9328: 93280B, 2015 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-25983371

RESUMO

Colorectal cancer is the second leading cause of cancer deaths in the United States, affecting more than 130,000 Americans every year1. Determining tumor margins prior to surgical resection is essential to providing optimal treatment and reducing recurrence rates. Colorectal cancer recurrence can occur in up to 20% of cases, commonly within three years after curative treatment. Typically, when colorectal cancers are resected, a margin of normal tissue on both sides of the tumor is required. The minimum margin required for colon cancer is 5 cm and for the lower rectum 2 cm. However, usually more normal tissue is taken on both sides of the tumor because the blood supply to the entire segment is removed with the surgery and therefore the entire segment must be removed. Anastomotic recurrences may result from inadequate margins. Pathologists look at the margins to ensure that there is no residual tumor and this is usually documented in the pathology report. We have developed a portable, point-of-care fiber bundle microendoscopy imaging system for detection of abnormalities in colonic epithelial microstructure. The system comprises a laptop, a modified fiber bundle image guide with a 1mm active area diameter and custom Lab VIEW interface, and is approved for imaging surgically resected colon tissue at the University of Arkansas for Medical Sciences. The microendoscopy probe provides high-resolution images of superficial epithelial histology in real-time to assist surgical guidance and to localize occult regions of dysplasia which may not be visible. Microendoscopy images of freshly resected human colonic epithelium were acquired using the microendoscopy device and subsequently mosaicked using custom post-processing software. Architectural changes in the glands were mapped to histopathology H&E slides taken from the precise location of the microendoscopy images. Qualitatively, glandular distortion and placement of image guide was used to map normal and dysplastic areas of the colonic tumor and surrounding region from microendoscopy images to H&E slides. Quantitative metrics for correlating images were also explored and were obtained by analyzing glandular diameter and spatial distribution as well as image texture.

6.
Proc SPIE Int Soc Opt Eng ; 9332: 93320R, 2015 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-25983372

RESUMO

Many cases of epithelial cancer originate in basal layers of tissue and are initially undetected by conventional microendoscopy techniques. We present a bench-top, fiber-bundle microendoscope capable of providing high resolution images of surface cell morphology. Additionally, the microendoscope has the capability to interrogate deeper into material by using diffuse reflectance and broadband diffuse reflectance spectroscopy. The purpose of this multimodal technique was to overcome the limitation of microendoscopy techniques that are limited to only visualizing morphology at the tissue or cellular level. Using a custom fiber optic probe, high resolution surface images were acquired using topical proflavine to fluorescently stain non-keratinized epithelia. A 635 nm laser coupled to a 200 µm multimode fiber delivers light to the sample and the diffuse reflectance signal was captured by a 1 mm image guide fiber. Finally, a tungsten-halogen lamp coupled to a 200 µm multimode fiber delivers broadband light to the sample to acquire spectra at source-detector separations of 374, 729, and 1051 µm. To test the instrumentation, a high resolution proflavine-induced fluorescent image of resected healthy mouse colon was acquired. Additionally, five monolayer poly(dimethylsiloxane)-based optical phantoms with varying absorption and scattering properties were created to acquire diffuse reflectance profiles and broadband spectra.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA