Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
J Bronchology Interv Pulmonol ; 31(2): 175-182, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37759354

RESUMO

BACKGROUND: Cone-beam computed tomography (CBCT) and augmented fluoroscopy (AF), in which intraprocedural CBCT data is fused with fluoroscopy, have been utilized as a novel image-guidance technique for biopsy of peripheral pulmonary lesions. The aim of this clinical study is to determine the safety and diagnostic performance of CBCT-guided bronchoscopy with advanced software tools for procedural planning and navigational guidance with AF of the airways for biopsy of peripheral pulmonary nodules. METHODS: Fifty-two consecutive subjects were prospectively enrolled in the AIRWAZE study (December 2018 to October 2019). Image-guided bronchoscopic biopsy procedures were performed under general anesthesia with specific ventilation protocols in a hybrid operating room equipped with a ceiling-mounted C-arm system. Procedural planning and image-guided bronchoscopy with CBCT and AF were performed using the Airwaze investigational device. RESULTS: A total of 58 pulmonary lesions with a median size of 19.0 mm (range 7 to 48 mm) were biopsied. The overall diagnostic yield at index procedure was 87.9% (95% CI: 77.1%-94.0%). No severe adverse events related to CBCT-guided bronchoscopy, such as pneumothorax, bleeding, or respiratory failure, were observed. CONCLUSION: CBCT-guided bronchoscopic biopsy with augmented fluoroscopic views of the airways and target lesion for navigational guidance is technically feasible and safe. Three-dimensional image-guided navigation biopsy is associated with high navigational success and a high diagnostic yield for peripheral pulmonary nodules.


Assuntos
Biópsia Guiada por Imagem , Neoplasias Pulmonares , Humanos , Estudos Prospectivos , Biópsia Guiada por Imagem/métodos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Fluoroscopia/métodos , Broncoscopia/métodos , Estudos Retrospectivos
3.
PLoS One ; 18(7): e0287409, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37432960

RESUMO

A blood-based integrated classifier (IC) has been clinically validated to improve accuracy in assessing probability of cancer risk (pCA) for pulmonary nodules (PN). This study evaluated the clinical utility of this biomarker for its ability to reduce invasive procedures in patients with pre-test pCA ≤ 50%. This was a propensity score matching (PSM) cohort study comparing patients in the ORACLE prospective, multicenter, observational registry to control patients treated with usual care. This study enrolled patients meeting the intended use criteria for IC testing: pCA ≤ 50%, age ≥40 years, nodule diameter 8-30 mm, and no history of lung cancer and/or active cancer (except for non-melanomatous skin cancer) within 5 years. The primary aim of this study was to evaluate invasive procedure use on benign PNs of registry patients as compared to control patients. A total of 280 IC tested, and 278 control patients met eligibility and analysis criteria and 197 were in each group after PSM (IC and control groups). Patients in the IC group were 74% less likely to undergo an invasive procedure as compared to the control group (absolute difference 14%, p <0.001) indicating that for every 7 patients tested, one unnecessary invasive procedure was avoided. Invasive procedure reduction corresponded to a reduction in risk classification, with 71 patients (36%) in the IC group classified as low risk (pCA < 5%). The proportion of IC group patients with malignant PNs sent to surveillance were not statistically different than the control group, 7.5% vs 3.5% for the IC vs. control groups, respectively (absolute difference 3.91%, p 0.075). The IC for patients with a newly discovered PN has demonstrated valuable clinical utility in a real-world setting. Use of this biomarker can change physicians' practice and reduce invasive procedures in patients with benign pulmonary nodules. Trial registration: Clinical trial registration: ClinicalTrials.gov NCT03766958.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Humanos , Adulto , Estudos de Coortes , Estudos Prospectivos , Neoplasias Pulmonares/diagnóstico , Grupos Controle , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Pontuação de Propensão
4.
Respiration ; 102(3): 182-193, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36652940

RESUMO

BACKGROUND: Image-guided percutaneous thermal ablation is an established treatment option for early-stage lung cancer in medically inoperable patients but carries a high risk of pleura-related complications, particularly pneumothorax. OBJECTIVE: This study aimed to determine if image-guided transbronchial microwave ablation (tMWA) is a feasible approach to treat peripheral stage 1 lung cancer. METHOD: A prospective, single-arm, multicenter study sought to enroll 40 adults who were medically inoperable or declined surgery for peripheral stage 1 lung tumors (≤20 mm). Ablation was performed using navigational bronchoscopy and a flexible MWA probe, guided by cone-beam CT with augmented fluoroscopy. Follow-up at 1, 6, and 12 months included CT imaging of the ablation zone and possible tumor recurrence, adverse events (AEs), pulmonary function, and quality of life. RESULTS: Across 2 sites, 11 tumors (10 NSCLC, 1 carcinoid) were treated in 10 enrolled patients. Median tumor diameter was 13 × 14 mm (7-19 mm) and median minimum ablative margin was 11 mm (5-19 mm). Technical success and technique efficacy were achieved in all patients. No tumor recurrence was seen during 12-month follow-up. No pneumothorax, pleural effusion, or bronchopleural fistula were noted. Minor AEs included scant hemoptysis, pain, cough, and dyspnea. Two serious AEs occurred ≤30 days of ablation and included a COPD exacerbation (day 9) and a death of unknown cause (day 15). The death led the sponsor to halt enrollment. Pulmonary function and quality-of-life indices remained stable. CONCLUSIONS: Image-guided tMWA is a technically feasible approach for peripheral early-stage lung cancer but warrants further evaluation of safety and efficacy in larger cohorts.


Assuntos
Ablação por Cateter , Neoplasias Pulmonares , Pneumotórax , Adulto , Humanos , Micro-Ondas/uso terapêutico , Estudos Prospectivos , Qualidade de Vida , Ablação por Cateter/efeitos adversos , Recidiva Local de Neoplasia/etiologia , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/cirurgia , Neoplasias Pulmonares/patologia , Pneumotórax/etiologia , Pneumotórax/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
5.
Semin Respir Crit Care Med ; 43(4): 473-479, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-36104024

RESUMO

The process of detection, diagnosis, and management of lung nodules is complex due to the heterogeneity of lung pathology and a relatively low malignancy rate. Technological advances in bronchoscopy have led to less-invasive diagnostic procedures and advances in imaging technology have helped to improve nodule localization and biopsy confirmation. Future research is required to determine which modality or combination of complimentary modalities is best suited for safe, accurate, and cost-effective management of lung nodules.


Assuntos
Broncoscopia , Procedimentos Cirúrgicos Robóticos , Biópsia , Broncoscopia/métodos , Diagnóstico por Imagem , Humanos
6.
J Thorac Oncol ; 17(4): 519-531, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34973418

RESUMO

INTRODUCTION: Electromagnetic navigation bronchoscopy (ENB) is a minimally invasive, image-guided approach to access lung lesions for biopsy or localization for treatment. However, no studies have reported prospective 24-month follow-up from a large, multinational, generalizable cohort. This study evaluated ENB safety, diagnostic yield, and usage patterns in an unrestricted, real-world observational design. METHODS: The NAVIGATE single-arm, pragmatic cohort study (NCT02410837) enrolled subjects at 37 academic and community sites in seven countries with prospective 24-month follow-up. Subjects underwent ENB using the superDimension navigation system versions 6.3 to 7.1. The prespecified primary end point was procedure-related pneumothorax requiring intervention or hospitalization. RESULTS: A total of 1388 subjects were enrolled for lung lesion biopsy (1329; 95.7%), fiducial marker placement (272; 19.6%), dye marking (23; 1.7%), or lymph node biopsy (36; 2.6%). Concurrent endobronchial ultrasound-guided staging occurred in 456 subjects. General anesthesia (78.2% overall, 56.6% Europe, 81.4% United States), radial endobronchial ultrasound (50.6%, 4.0%, 57.4%), fluoroscopy (85.0%, 41.7%, 91.0%), and rapid on-site evaluation use (61.7%, 17.3%, 68.5%) differed between regions. Pneumothorax and bronchopulmonary hemorrhage occurred in 4.7% and 2.7% of subjects, respectively (3.2% [primary end point] and 1.7% requiring intervention or hospitalization). Respiratory failure occurred in 0.6%. The diagnostic yield was 67.8% (range: 61.9%-70.7%; 55.2% Europe, 69.8% United States). Sensitivity for malignancy was 62.6%. Lung cancer clinical stage was I to II in 64.7% (55.3% Europe, 65.8% United States). CONCLUSIONS: Despite a heterogeneous cohort and regional differences in procedural techniques, ENB demonstrates low complications and a 67.8% diagnostic yield while allowing biopsy, staging, fiducial placement, and dye marking in a single procedure.


Assuntos
Neoplasias Pulmonares , Pneumotórax , Broncoscopia/métodos , Estudos de Coortes , Fenômenos Eletromagnéticos , Humanos , Pulmão/patologia , Neoplasias Pulmonares/complicações , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/cirurgia , Pneumotórax/epidemiologia , Pneumotórax/etiologia , Pneumotórax/patologia , Estudos Prospectivos , Estados Unidos
7.
Ann Thorac Surg ; 113(1): 308-315, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34370981

RESUMO

PURPOSE: This report describes the Ion Endoluminal System (Intuitive Surgical, Inc, Sunnyvale, CA) and practices for safe and effective use in patients with small peripheral pulmonary nodules (PPNs). DESCRIPTION: This shape-sensing robotic-assisted bronchoscopy system allows airway visualization and navigation to reach and biopsy small PPNs through a stable platform. The system provides 3-dimensional mapping and visualization of the airways, a flexible and fully articulating 3.5-mm (outer diameter) catheter, a peripheral vision probe, and system-specific biopsy needles. EVALUATION: The Ion Endoluminal System was evaluated in an ongoing prospective, multicenter trial including 241 patients with 270 PPNs (largest mean cardinal measurement, 18.8 ± 6.5 mm). Mean time to register and navigate decreased from 10 minutes in the first 10 cases to 7 minutes in the subsequent cases. Asymptomatic pneumothorax occurred in 8 patients (3.3%), 1 (0.4%) with pigtail catheter placement. Two patients (0.8%) experienced airway bleeding; both cases of bleeding resolved within 5 minutes of tamponade. CONCLUSIONS: The Ion Endoluminal System's unique shape-sensing technology can be leveraged to facilitate localization and sampling of PPNs and potentially improve diagnostic accuracy.


Assuntos
Broncoscopia/instrumentação , Broncoscopia/métodos , Nódulos Pulmonares Múltiplos/cirurgia , Procedimentos Cirúrgicos Robóticos/instrumentação , Adulto , Desenho de Equipamento , Feminino , Humanos , Masculino , Estudos Prospectivos
8.
J Bronchology Interv Pulmonol ; 29(1): 7-17, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33734150

RESUMO

BACKGROUND: Computed tomography-to-body divergence caused by respiratory motion, atelectasis, diaphragmatic motion and other factors is an obstacle to peripheral lung biopsies. We examined a conventional ventilation strategy versus a lung navigation ventilation protocol (LNVP) optimized for intraprocedural 3-dimensional image acquisition and bronchoscopic biopsy of peripheral lung nodules. METHODS: A retrospective, single center study was conducted in consecutive subjects with peripheral lung lesions measuring <30 mm. Effects of ventilation strategies including atelectasis and tool-in-lesion confirmation were assessed using cone beam computed tomography images. Diagnostic yield was also evaluated. Complications were assessed through 7 days. RESULTS: Fifty subjects were included (25 per group) with 27 nodules in the conventional group and 25 nodules in the LNVP group. Atelectasis was assessed by 2 blinded readers: [reader 1 (R1) and reader 2 (R2)]. Atelectasis was more prevalent in the conventional ventilation group, both for dependent atelectasis (R1: 64% and R2: 68% vs. R1: 36% and R2: 16%, P=0.00014) and sublobar/lobar atelectasis (R1: 48% and R2: 56% vs. R1: 20% and R2: 32%, P=0.01). Similarly, the target lesion was obscured due to atelectasis more often in the conventional ventilation group (R1: 36% and R2: 36% vs. R1: 4% and R2: 8%, P=0.01). Diagnostic yield was 70% for conventional ventilation and 92% for LNVP (P=0.08). CONCLUSION: LNVP demonstrated markedly reduced dependent and sublobar/lobar atelectasis and lesions either partially or completely obscured by atelectasis compared with conventional ventilation. Future prospective studies are necessary to understand the impact of protocolized ventilation strategies for bronchoscopic biopsy of peripheral lung lesions.


Assuntos
Broncoscopia , Atelectasia Pulmonar , Biópsia , Humanos , Pulmão/diagnóstico por imagem , Estudos Prospectivos , Atelectasia Pulmonar/diagnóstico por imagem , Estudos Retrospectivos
9.
BMC Pulm Med ; 21(1): 322, 2021 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-34656103

RESUMO

BACKGROUND: Traditional bronchoscopy provides limited approach to peripheral nodules. Shape-sensing robotic-assisted bronchoscopy (SSRAB, Ion™ Endoluminal System) is a new tool for minimally invasive peripheral nodule biopsy. We sought to answer the research question: Does SSRAB facilitate sampling of pulmonary nodules during bronchoscopists' initial experience? METHODS: The lead-in stage of a multicenter, single-arm, prospective evaluation of the Ion Endoluminal System (PRECIsE) is described. Enrolled subjects ≥ 18 years old had recent computed tomography evidence of one or more solid or semi-solid pulmonary nodules ≥ 1.0 to ≤ 3.5 cm in greatest dimension and in any part of the lung. Subjects were followed at 10- and 30-days post-procedure. This stage provided investigators and staff their first human experience with the SSRAB system; safety and procedure outcomes were analyzed descriptively. Neither diagnostic yield nor sensitivity for malignancy were assessed in this stage. Categorical variables are summarized by percentage; continuous variables are summarized by median/interquartile range (IQR). RESULTS: Sixty subjects were enrolled across 6 hospitals; 67 nodules were targeted for biopsy. Median axial, coronal and sagittal diameters were < 18 mm with a largest cardinal diameter of 20.0 mm. Most nodules were extraluminal and distance from the outer edge of the nodule to the pleura or nearest fissure was 4.0 mm (IQR: 0.0, 15.0). Median bronchial generation count to the target location was 7.0 (IQR: 6.0, 8.0). Procedure duration (catheter-in to catheter-out) was 66.5 min (IQR: 50.0, 85.5). Distance from the catheter tip to the closest edge of the virtual nodule was 7.0 mm (IQR: 2.0, 12.0). Biopsy completion was 97.0%. No pneumothorax or airway bleeding of any grade was reported. CONCLUSIONS: Bronchoscopists leveraged the Ion SSRAB's functionality to drive the catheter safely in close proximity of the virtual target and to obtain biopsies. This initial, multicenter experience is encouraging, suggesting that SSRAB may play a role in the management of pulmonary nodules. Clinical Trial Registration identifier and date NCT03893539; 28/03/2019.


Assuntos
Broncoscopia/métodos , Nódulos Pulmonares Múltiplos/patologia , Procedimentos Cirúrgicos Robóticos/métodos , Nódulo Pulmonar Solitário/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Estados Unidos
10.
BMC Pulm Med ; 21(1): 240, 2021 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-34273966

RESUMO

Partnership between anesthesia providers and proceduralists is essential to ensure patient safety and optimize outcomes. A renewed importance of this axiom has emerged in advanced bronchoscopy and interventional pulmonology. While anesthesia-induced atelectasis is common, it is not typically clinically significant. Advanced guided bronchoscopic biopsy is an exception in which anesthesia protocols substantially impact outcomes. Procedure success depends on careful ventilation to avoid excessive motion, reduce distortion causing computed tomography (CT)-to-body-divergence, stabilize dependent areas, and optimize breath-hold maneuvers to prevent atelectasis. Herein are anesthesia recommendations during guided bronchoscopy. An FiO2 of 0.6 to 0.8 is recommended for pre-oxygenation, maintained at the lowest tolerable level for the entire the procedure. Expeditious intubation (not rapid-sequence) with a larger endotracheal tube and non-depolarizing muscle relaxants are preferred. Positive end-expiratory pressure (PEEP) of up to 10-12 cm H2O and increased tidal volumes help to maintain optimal lung inflation, if tolerated by the patient as determined during recruitment. A breath-hold is required to reduce motion artifact during intraprocedural imaging (e.g., cone-beam CT, digital tomosynthesis), timed at the end of a normal tidal breath (peak inspiration) and held until pressures equilibrate and the imaging cycle is complete. Use of the adjustable pressure-limiting valve is critical to maintain the desired PEEP and reduce movement during breath-hold maneuvers. These measures will reduce atelectasis and CT-to-body divergence, minimize motion artifact, and provide clearer, more accurate images during guided bronchoscopy. Following these recommendations will facilitate a successful lung biopsy, potentially accelerating the time to treatment by avoiding additional biopsies. Application of these methods should be at the discretion of the anesthesiologist and the proceduralist; best medical judgement should be used in all cases to ensure the safety of the patient.


Assuntos
Anestesia Geral/métodos , Broncoscopia/efeitos adversos , Complicações Intraoperatórias/prevenção & controle , Pulmão/diagnóstico por imagem , Atelectasia Pulmonar/prevenção & controle , Suspensão da Respiração , Broncoscopia/métodos , Humanos , Complicações Intraoperatórias/etiologia , Respiração com Pressão Positiva/métodos , Atelectasia Pulmonar/etiologia , Tomografia Computadorizada por Raios X
11.
J Bronchology Interv Pulmonol ; 28(2): 107-115, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32732491

RESUMO

BACKGROUND: Navigational bronchoscopy has improved upon traditional bronchoscopy to identify suspicious pulmonary lesions, but wide variability exists in the diagnostic yield of various modalities. The aim of this study was to measure localization accuracy and diagnostic yield of a novel endobronchial augmented fluoroscopic navigation system (first-generation LungVision system) for peripheral pulmonary lesions (PPLs). METHODS: This prospective single-center study included adults undergoing guided bronchoscopy to evaluate PPLs. Preprocedure computed tomography (CT) images were obtained, and planning software calculated a pathway to the lesion. A flexible bronchoscope was used to navigate along the pathway overlaid on the intraprocedural fluoroscopic image. When real-time display indicated the catheter tip had reached the lesion, cone-beam computed tomography (CBCT) was used to measure the actual location of the tip. Biopsy and rapid on-site cytopathologic evaluation were performed. RESULTS: Fifty-one patients were included in the analysis. The median lesion diameter was 18.0 mm (range: 7.0 to 48.0 mm). Localization success was 96.1%. The average distance between lesion location as shown by LungVision augmented fluoroscopy and actual location measured by CBCT was 5.9 mm (range: 2.1 to 10.0 mm). Diagnostic yield at the index procedure was 78.4%. Diagnostic accuracy assessed at 12 months follow-up was 88.2%. Average CT-to-body divergence was 14.5 mm (range: 2.6 to 33.0 mm) from preprocedure CT to intraprocedural CBCT images. CONCLUSION: Augmented fluoroscopy for navigation and biopsy of PPLs with the LungVision system showed a high localization success rate and corresponding high diagnostic yield. Navigation and biopsy with real-time visualization can improve diagnostic yield for PPLs.


Assuntos
Neoplasias Pulmonares , Adulto , Biópsia , Broncoscopia , Fluoroscopia , Humanos , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem
12.
J Bronchology Interv Pulmonol ; 28(1): 10-20, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32412920

RESUMO

BACKGROUND: Electromagnetic navigation bronchoscopy (ENB) aids in lung lesion biopsy. However, anatomic divergence between the preprocedural computed tomography (CT) and the actual bronchial anatomy during the procedure can limit localization accuracy. An advanced ENB system has been designed to mitigate CT-to-body divergence using a tomosynthesis-based software algorithm that enhances nodule visibility and allows for intraprocedural local registration. MATERIALS AND METHODS: A prospective, 2-center study was conducted in subjects with single peripheral lung lesions ≥10 mm to assess localization accuracy of the superDimension navigation system with fluoroscopic navigation technology. Three-dimensional accuracy was confirmed by cone-beam computed tomography. Complications were assessed through 7 days. RESULTS: Fifty subjects were enrolled (25 per site). Lesions were <20 mm in 61.2% (30/49). A bronchus sign was present in 53.1% (26/49). Local registration was completed in 95.9% (47/49). Three-dimensional target overlap (primary endpoint) was achieved in 59.6% (28/47) and 83.0% (39/47) before and after location correction, respectively. Excluding subjects with unevaluable video files, target overlap was achieved 68.3% (28/41) and 95.1% (39/41), respectively. Malignant results were obtained in 53.1% (26/49) by rapid on-site evaluation and 61.2% (30/49) by final pathology of the ENB-aided sample. Diagnostic yield was not evaluated. Procedure-related complications were pneumothorax in 1 subject (no chest tube required) and scant hemoptysis in 3 subjects (no interventions required). CONCLUSION: ENB with tomosynthesis-based fluoroscopic navigation improved the 3-dimensional convergence between the virtual target and actual lung lesion as confirmed by cone-beam computed tomography. Future studies are necessary to understand the impact of this technology on diagnostic yield.


Assuntos
Broncoscopia , Neoplasias Pulmonares , Tomografia Computadorizada de Feixe Cônico , Fenômenos Eletromagnéticos , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Estudos Prospectivos
13.
J Bronchology Interv Pulmonol ; 28(3): 174-183, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-33369988

RESUMO

BACKGROUND: The diagnostic yield of electromagnetic navigation bronchoscopy (ENB) is impacted by biopsy tool strategy and rapid on-site evaluation (ROSE) use. This analysis evaluates usage patterns, accuracy, and safety of tool strategy and ROSE in a multicenter study. METHODS: NAVIGATE (NCT02410837) evaluates ENB using the superDimension navigation system (versions 6.3 to 7.1). The 1-year analysis included 1215 prospectively enrolled subjects at 29 United States sites. Included herein are 416 subjects who underwent ENB-aided biopsy of a single lung lesion positive for malignancy at 1 year. Use of a restricted number of tools (only biopsy forceps, standard cytology brush, and/or bronchoalveolar lavage) was compared with an extensive multimodal strategy (biopsy forceps, cytology brush, aspirating needle, triple needle cytology brush, needle-tipped cytology brush, core biopsy system, and bronchoalveolar lavage). RESULTS: Of malignant cases, 86.8% (361/416) of true positive diagnoses were obtained using extensive multimodal strategies. ROSE was used in 300/416 cases. The finding of malignancy by ROSE reduced the total number of tools used. A malignant ROSE call was obtained in 71% (212/300), most (88.7%; 188/212) by the first tool used (49.5% with aspirating needle, 20.2% with cytology brush, 17.0% with forceps). True positive rates were highest for the biopsy forceps (86.9%) and aspirating needle (86.6%). Use of extensive tool strategies did not increase the rates of pneumothorax (5.5% restricted, 2.8% extensive) or bronchopulmonary hemorrhage (3.6% restricted, 1.1% extensive). CONCLUSION: These results suggest that extensive biopsy tool strategies, including the aspirating needle, may provide higher true positive rates for detecting lung cancer without increasing complications.


Assuntos
Neoplasias Pulmonares , Pneumotórax , Biópsia , Broncoscopia , Fenômenos Eletromagnéticos , Humanos , Neoplasias Pulmonares/diagnóstico , Estudos Prospectivos
15.
J Thorac Dis ; 12(4): 1595-1611, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32395297

RESUMO

Guided bronchoscopy offers a minimally invasive and safe method for accessing indeterminate pulmonary nodules. However, all current guided bronchoscopy systems rely on a preprocedural computed tomography (CT) scan to create a virtual map of the patient's airways. Changes in lung anatomy between the preprocedural CT scan and the bronchoscopy procedure can lead to a divergence between the expected and actual location of the target lesion. Termed "CT-to-body divergence", this effect reduces diagnostic yield, adds time to the procedure, and can be challenging for the operator. The objective of this paper is to describe the concept of CT-to-body divergence, its contributing factors, and methods and technologies that might minimize its deleterious effects on diagnostic yield.

16.
Clin Respir J ; 13(11): 700-707, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31424623

RESUMO

INTRODUCTION: Electromagnetic navigation bronchoscopy (ENB)-guided pleural dye marking is useful to localize small peripheral pulmonary nodules for sublobar resection. OBJECTIVE: To report findings on the use of ENB-guided dye marking among participants in the NAVIGATE study. METHODS: NAVIGATE is a prospective, multicentre, global and observational cohort study of ENB use in patients with lung lesions. The current subgroup report is a prespecified 1-month interim analysis of ENB-guided pleural dye marking in the NAVIGATE United States cohort. RESULTS: The full United States cohort includes 1215 subjects from 29 sites (April 2015 to August 2016). Among those, 23 subjects (24 lesions) from seven sites underwent dye marking in preparation for surgical resection. ENB was conducted for dye marking alone in nine subjects while 14 underwent dye marking concurrent with lung lesion biopsy, lymph node biopsy and/or fiducial marker placement. The median nodule size was 10 mm (range 4-22) and 83.3% were <20 mm in diameter. Most lesions (95.5%) were located in the peripheral third of the lung, at a median of 3.0 mm from the pleura. The median ENB-specific procedure time was 11.5 minutes (range 4-38). The median time from dye marking to resection was 0.5 hours (range 0.3-24). Dye marking was adequate for surgical resection in 91.3%. Surgical biopsies were malignant in 75% (18/24). CONCLUSION: In this study, ENB-guided dye marking to localize lung lesions for surgery was safe, accurate and versatile. More information is needed about surgical practice patterns and the utility of localization procedures.


Assuntos
Broncoscopia/métodos , Corantes/administração & dosagem , Campos Eletromagnéticos/efeitos adversos , Neoplasias Pulmonares/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Biópsia , Broncoscopia/tendências , Fenômenos Eletromagnéticos , Feminino , Marcadores Fiduciais , Humanos , Pulmão/patologia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/cirurgia , Linfonodos/patologia , Masculino , Pessoa de Meia-Idade , Pleura/metabolismo , Pleura/patologia , Estudos Prospectivos , Cirurgia Torácica Vídeoassistida/métodos , Estados Unidos/epidemiologia
17.
Ther Adv Respir Dis ; 13: 1753466619841234, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30958102

RESUMO

BACKGROUND: Fiducial markers (FMs) help direct stereotactic body radiation therapy (SBRT) and localization for surgical resection in lung cancer management. We report the safety, accuracy, and practice patterns of FM placement utilizing electromagnetic navigation bronchoscopy (ENB). METHODS: NAVIGATE is a global, prospective, multicenter, observational cohort study of ENB using the superDimension™ navigation system. This prospectively collected subgroup analysis presents the patient demographics, procedural characteristics, and 1-month outcomes in patients undergoing ENB-guided FM placement. Follow up through 24 months is ongoing. RESULTS: Two-hundred fifty-eight patients from 21 centers in the United States were included. General anesthesia was used in 68.2%. Lesion location was confirmed by radial endobronchial ultrasound in 34.5% of procedures. The median ENB procedure time was 31.0 min. Concurrent lung lesion biopsy was conducted in 82.6% (213/258) of patients. A mean of 2.2 ± 1.7 FMs (median 1.0 FMs) were placed per patient and 99.2% were accurately positioned based on subjective operator assessment. Follow-up imaging showed that 94.1% (239/254) of markers remained in place. The procedure-related pneumothorax rate was 5.4% (14/258) overall and 3.1% (8/258) grade ⩾ 2 based on the Common Terminology Criteria for Adverse Events scale. The procedure-related grade ⩾ 4 respiratory failure rate was 1.6% (4/258). There were no bronchopulmonary hemorrhages. CONCLUSION: ENB is an accurate and versatile tool to place FMs for SBRT and localization for surgical resection with low complication rates. The ability to perform a biopsy safely in the same procedure can also increase efficiency. The impact of practice pattern variations on therapeutic effectiveness requires further study. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT02410837.


Assuntos
Broncoscopia/métodos , Fenômenos Eletromagnéticos , Marcadores Fiduciais , Neoplasias Pulmonares/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia/métodos , Estudos de Coortes , Endossonografia/métodos , Feminino , Seguimentos , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Masculino , Pessoa de Meia-Idade , Pneumotórax/epidemiologia , Pneumotórax/etiologia , Estudos Prospectivos , Radiocirurgia/métodos , Insuficiência Respiratória/epidemiologia , Insuficiência Respiratória/etiologia
18.
Artigo em Inglês | MEDLINE | ID: mdl-32914040

RESUMO

PURPOSE: Guidelines advocate molecular profiling in the evaluation of advanced non-small-cell lung cancer (NSCLC) and support the use of plasma circulating tumor DNA (ctDNA)-based profiling for patients with insufficient tissue. Thorough prospective clinical validation studies of next-generation sequencing (NGS)-based ctDNA assays are lacking. We report the multicentered prospective clinical validation of the InVision ctDNA assay in patients with advanced untreated NSCLC. METHODS: A total of 264 patients with untreated advanced NSCLC were prospectively recruited, and their plasma was analyzed using a ctDNA NGS assay for detection of genomic alterations in 36 commonly mutated genes. Tumor tissue was available in 178 patients for molecular profiling for comparison with plasma profiling. The remaining 86 patients were included to compare ctDNA profiles in patients with and without tissue for profiling. RESULTS: Concordance of InVisionFirst with matched tissue profiling was 97.8%, with 82.9% positive predictive value, 98.5% negative predictive value, 70.6% sensitivity, and 99.2% specificity. Considering specific alterations in eight genes that most influence patient management, the positive predictive value was 97.8%, with 97.1% negative predictive value, 73.9% sensitivity, and 99.8% specificity. Across the entire study, 48 patients with actionable alterations were identified by ctDNA testing compared with only 38 by tissue testing. ctDNA NGS reported either an actionable alteration or an alteration generally considered mutually exclusive for such actionable changes in 53% of patients. CONCLUSION: The liquid biopsy NGS assay demonstrated excellent concordance with tissue profiling in this multicenter, prospective, clinical validation study, with sensitivity and specificity equivalent to Food and Drug Administration-approved single-gene ctDNA assays. The use of plasma-based molecular profiling using NGS led to the detection of 26% more actionable alterations compared with standard-of-care tissue testing in this study.

19.
J Thorac Oncol ; 14(3): 445-458, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30476574

RESUMO

INTRODUCTION: Electromagnetic navigation bronchoscopy (ENB) is a minimally invasive technology that guides endoscopic tools to pulmonary lesions. ENB has been evaluated primarily in small, single-center studies; thus, the diagnostic yield in a generalizable setting is unknown. METHODS: NAVIGATE is a prospective, multicenter, cohort study that evaluated ENB using the superDimension navigation system (Medtronic, Minneapolis, Minnesota). In this United States cohort analysis, 1215 consecutive subjects were enrolled at 29 academic and community sites from April 2015 to August 2016. RESULTS: The median lesion size was 20.0 mm. Fluoroscopy was used in 91% of cases (lesions visible in 60%) and radial endobronchial ultrasound in 57%. The median ENB planning time was 5 minutes; the ENB-specific procedure time was 25 minutes. Among 1157 subjects undergoing ENB-guided biopsy, 94% (1092 of 1157) had navigation completed and tissue obtained. Follow-up was completed in 99% of subjects at 1 month and 80% at 12 months. The 12-month diagnostic yield was 73%. Pathology results of the ENB-aided tissue samples showed malignancy in 44% (484 of 1092). Sensitivity, specificity, positive predictive value, and negative predictive value for malignancy were 69%, 100%, 100%, and 56%, respectively. ENB-related Common Terminology Criteria for Adverse Events grade 2 or higher pneumothoraces (requiring admission or chest tube placement) occurred in 2.9%. The ENB-related Common Terminology Criteria for Adverse Events grade 2 or higher bronchopulmonary hemorrhage and grade 4 or higher respiratory failure rates were 1.5% and 0.7%, respectively. CONCLUSIONS: NAVIGATE shows that an ENB-aided diagnosis can be obtained in approximately three-quarters of evaluable patients across a generalizable cohort based on prospective 12-month follow-up in a pragmatic setting with a low procedural complication rate.


Assuntos
Broncoscopia/métodos , Pneumopatias/diagnóstico , Pneumotórax/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Eletromagnéticos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Adulto Jovem
20.
Chest ; 155(1): 137-146, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30292760

RESUMO

BACKGROUND: While the complexity of flexible bronchoscopy has increased, standard options for moderate sedation medications have not changed in three decades. There is a need to improve moderate sedation while maintaining safety. Remimazolam was developed to address shortcomings of current sedation strategies. METHODS: A prospective, double-blind, randomized, multicenter, parallel group trial was performed at 30 US sites. The efficacy and safety of remimazolam for sedation during flexible bronchoscopy were compared with placebo and open-label midazolam. RESULTS: The success rates were 80.6% in the remimazolam arm, 4.8% in the placebo arm (P < .0001), and 32.9% in the midazolam arm. Bronchoscopy was started sooner in the remimazolam arm (mean, 6.4 ± 5.82 min) compared with placebo (17.2 ± 4.15 min; P < .0001) and midazolam (16.3 ± 8.60 min). Time to full alertness after the end of bronchoscopy was significantly shorter in patients treated with remimazolam (median, 6.0 min; 95% CI, 5.2-7.1) compared with those treated with placebo (13.6 min; 95% CI, 8.1-24.0; P = .0001) and midazolam (12.0 min; 95% CI, 5.0-15.0). Remimazolam registered superior restoration of neuropsychiatric function compared with placebo and midazolam. Safety was comparable among all three arms, and 5.6% of the patients in the remimazolam group had serious treatment-emergent adverse events as compared with 6.8% in the placebo group. CONCLUSIONS: Remimazolam administered under the supervision of a pulmonologist was effective and safe for moderate sedation during flexible bronchoscopy. In an exploratory analysis, it demonstrated a shorter onset of action and faster neuropsychiatric recovery than midazolam.


Assuntos
Benzodiazepinas/administração & dosagem , Broncoscopia/métodos , Sedação Consciente/métodos , Midazolam/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Humanos , Hipnóticos e Sedativos/administração & dosagem , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA