Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Heart ; 108(1): 22-28, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33674353

RESUMO

OBJECTIVE: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is associated with a risk of sudden cardiac death. Optimal risk stratification is still under debate. The main purpose of this long-term, single-centre observation was to analyse predictors of appropriate and inappropriate implantable cardioverter-defibrillator (ICD) interventions in the population of patients with ARVC with a high risk of life-threatening arrhythmias. METHODS: The study comprised 65 adult patients (median age 40 years, 48 men) with a definite diagnosis of ARVC who received ICD over a time span of 20 years in primary (40%) or secondary (60%) prevention of sudden cardiac death. The study endpoints were first appropriate and inappropriate ICD interventions (shock or antitachycardia pacing) after device implantation. RESULTS: During a median follow-up of 7.75 years after ICD implantation, nine patients died and six individuals underwent heart transplantation. Appropriate ICD interventions occurred in 43 patients (66.2%) and inappropriate ICD interventions in 18 patients (27.7%). Multivariable analysis using cause-specific hazard model identified three predictors of appropriate ICD interventions: right ventricle dysfunction (cause-specific HR 2.85, 95% CI 1.56 to 5.21, p<0.001), age <40 years at ICD implantation (cause-specific HR 2.37, 95% CI 1.13 to 4.94, p=0.022) and a history of sustained ventricular tachycardia (cause-specific HR 2.55, 95% CI 1.16 to 5.63, p=0.020). Predictors of inappropriate ICD therapy were not found. Complications related to ICD implantation occurred in 12 patients. CONCLUSIONS: Right ventricle dysfunction, age <40 years and a history of sustained ventricular tachycardia were predictors of appropriate ICD interventions in patients with ARVC. The results may be used to improve risk stratification before ICD implantation.


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Taquicardia Ventricular , Adulto , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Taquicardia Ventricular/complicações , Taquicardia Ventricular/terapia
3.
Kardiol Pol ; 78(4): 364-373, 2020 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-32336071

RESUMO

Many cardiovascular diseases lead to heart failure, which is a progressive syndrome causing significant distress and limiting the quality of life, despite optimal cardiologic treatment. It is estimated that about 26 000 people in Poland suffer from advanced heart failure, and this number is growing. That is why palliative care (PC) dedicated to people living with end­stage cardiac diseases should be urgently implemented in Poland. Well­organized PC may not only relieve symptoms and improve quality of life in people living with cardiac diseases not responding to treatment but also support patients and their families during the dying process. Palliative care in patients with cardiac diseases should be continued during the end-of-life period. It should be implemented regardless of prognosis, and adjusted to patients' needs. Two approaches to PC are presented in this expert opinion. The first one (generic) is provided by all medical professionals incorporating PC principles into the usual patient care. The second approach, namely, specialized PC, is ensured by a multiprofessional team or at least a PC specialist who received appropriate training in PC. The model of needs-based (not prognosis-based) implementation of PC is discussed in this paper. Symptom control, support in decision-making, and sensitive, open communication are considered integral elements of PC interventions. Medical professionals developing PC in Poland should think about groups of patients with special needs like those with valvular heart disease, grown­up congenital heart disease, and pulmonary arterial hypertension, as well as elderly people. This consensus document presents main recommendations for future PC organization in Poland. Among others, we suggest changing the Polish National Health Fund reimbursement rules regarding PC and improving cardiologist education on PC.


Assuntos
Insuficiência Cardíaca , Cuidados Paliativos , Idoso , Consenso , Insuficiência Cardíaca/terapia , Humanos , Polônia , Qualidade de Vida
4.
Kardiol Pol ; 77(11): 1106-1116, 2019 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-31741466

RESUMO

Older age and high morbidity of the society contribute to a growing number of patients with cardiac implantable electronic devices (CIEDs) requiring effective cancer treatment, including radiotherapy (RT). The effect of RT on a CIED may vary depending on the type and physical parameters of radiation, location of the treated lesion, indications for electrotherapy, and the type of CIED. In the most dramatic scenarios, it may cause an irreversible damage to the CIED, with serious clinical consequences. The lack of precise guidelines may limit the access to RT for many patients with CIEDs who would otherwise benefit from the therapy or may lead to a therapy without taking the necessary precautions, which may worsen the prognosis. Therefore, clear and unequivocal recommendations for assessing patient eligibility for RT are aimed at ensuring that adequate precautions are taken as well as at providing patients with concomitant cardiovascular and oncologic diseases with access to safe and effective RT.


Assuntos
Desfibriladores Implantáveis , Neoplasias/radioterapia , Marca-Passo Artificial , Falha de Prótese/efeitos da radiação , Radioterapia/efeitos adversos , Sociedades Médicas , Cardiologia , Humanos , Polônia , Radioterapia (Especialidade) , Medição de Risco
5.
Kardiol Pol ; 73(12): 1304-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25987399

RESUMO

BACKGROUND: Ensuring a haemodynamically effective cardiac rhythm is a challenge in patients waiting for pacemaker reimplantation after transcutaneous lead extraction due to an infection of the implanted system. AIM: The authors report a retrospective analysis of temporary pacing with an active fixation lead (AFTP) connected to an externalised pacemaker in patients after transvenous lead extraction (TLE) due to an infection. METHODS: AFTP was used in 34 patients (12 women) aged from 38 to 88 years (mean 67.5 years). This represented 24.5% of the population of patients undergoing TLE due to infective indications. In 32 cases, the indication for temporary pacing was atrioventricular block, and in 2 patients sick sinus syndrome. The lead was implanted via the internal jugular vein puncture into the right ventricle in 33 cases and into the right atrium in 1 case. Leads were secured to the skin and attached to externalized pacemakers. RESULTS: AFTP was used for 4 to 26 days (average 14.5 days). Re-implantation was performed in 29 patients (85.3% of the study group). There was no early infection recurrence. Three patients died during AFTP (8.8% of the study group), including two due to septic shock, and a cardiac arrest due to pulseless electrical activity in another patient. CONCLUSIONS: Temporary pacing with an active fixation lead is an effective and safe method to ensure a hemodynamically stable heart rhythm for a period ranging from a few to several days after the surgery in patients after transcutaneous lead extraction due to infective indications.


Assuntos
Bloqueio Atrioventricular/terapia , Infecções Cardiovasculares/etiologia , Remoção de Dispositivo , Eletrodos Implantados/efeitos adversos , Marca-Passo Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Infecções Cardiovasculares/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
Cardiol J ; 22(2): 188-93, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25299498

RESUMO

BACKGROUND: Still increasing life expectancy in patients with implanted devices and large number of leads more and more often induce the need to cure the treatment complications or to change especially to cardiac resynchronization therapy (CRT). In order to prevent further complications, the possibility of damaged or redundant leads extraction should be taken into consideration. The aim of the paper was to assess the effectiveness and safety of transvenous lead extraction (TLE) with co-implantation of resynchronization systems. METHODS AND RESULTS: Between 2008 and March 2013, the system removal with TLE was conducted in 246 patients. In 38 patients (11 women, 28.9%), aged 43-79 (mean 65 years), it was combined with co-implantation of CRT-pacemaker or defibrillator (CRT-P/D). Indications for TLE covered: lead failure in 21 (55.3%) patients, redundant leads in 6 (15.8%), and the occluded venous system in 7 (18.4%). The up-grade of the pacemaker or defibrillator system to CRT-D was performed in 19 cases, CRT-P/D revision in next 19. Together 32 defibrillation leads and 42 pacing leads (27 left ventricular leads, and 1 epicardial lead) were implanted. The intended clinical target--an effective resynchronization therapy--was obtained in all patients. There was no case of death or severe complications. In 2 cases of venous occlusion, the implantation on the contralateral side was required. CONCLUSIONS: TLE enables effective resynchronization therapy also in the case of the presence of too many leads, occlusion of the venous system or lead failure. Significant technical problems can occur especially in patients with venous system occlusion.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Remoção de Dispositivo/métodos , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Falha de Prótese , Infecções Relacionadas à Prótese/cirurgia , Adulto , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Polônia , Desenho de Prótese , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Sistema de Registros , Reoperação , Fatores de Tempo , Resultado do Tratamento
7.
Kardiol Pol ; 71(1): 17-24, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23348529

RESUMO

BACKGROUND: Atrial fibrillation (AF) in patients with hypertrophic cardiomyopathy (HCM) is generally associated with deterioration of the clinical status, functional capacity, and quality of life. It is also an independent risk factor for stroke and death. Studies evaluating the effectiveness of AF ablation in this cohort are relatively scant, have included relatively few patients, and their results are somewhat conflicting. Thus, the aim of this study was to assess the safety and efficacy of catheter ablation of AF in patients with HCM. METHODS: Thirty patients (10 females; mean age 48.7 ± 11 years) with drug-refractory paroxysmal (n = 14), persistent (n = 7), or long-persistent (> 1 year; n = 9) AF were prospectively recruited into the study. Eleven patients were in New York Heart Association (NYHA) class I, 13 patients were in NYHA class II, and 6 patients were in NYHA class III. Mean atrial volume was 180 ± 47 mL, interventricular septum thickness was 20.5 ± 6.3 mm, and left atrial area was 29.8 ± 6.2 cm2. Ablation protocol was adjusted to the clinical and electrophysiological status of the patients. Pulmonary vein isolation and bidirectional cavo-tricuspid isthmus block were performed in all patients. In addition, left atrial linear lesions were created and complex fragmented atrial potentials were ablated in patients with persistent and long-persistent AF, as well as during repeated procedures. RESULTS: At 12 months, stable sinus rhythm (SR) was present in 16 (53%) patients, significantly more frequently in patients with paroxysmal AF (71% in SR) compared to those with persistent (57.1% in SR) or long-persistent (22% in SR) AF. A significant reduction of AF burden was observed in 85.7% of patients with paroxysmal AF, 71.4% of patients with persistent AF, and 55.5% of patients with long-persistent AF. Single procedure success rate was 33% (10 patients), and repeat ablation procedures were performed in 13 patients. No periprocedural complications occurred. Thromboembolic events were noted in 2 patients with arrhythmia recurrence during the follow-up, including stroke in 1 patient and peripheral embolism in the other patient. In both these patients, heart failure worsening was observed during these events, and anticoagulation was inadequate in one of them. Five of 16 patients in whom stable SR was observed during the follow-up were off antiarrhythmic drug therapy at final evaluation. In the other 6 patients, antiarrhythmic drug therapy was continued due to ventricular arrhythmias. Successfully treated patients more often had paroxysmal AF (successful ablation: paroxysmal AF in 10 of 16 patients; unsuccessful ablation: paroxysmal AF in 4 of 14 patients; p = 0.009) and were younger (45 ± 11.5 years vs. 52.6 ± 9.2 years; p = 0.046). In addition, a trend toward a reduced need for cardioversion at the end of the procedure was also observed in these patients (3 patients in the successful ablation group vs. 8 patients in the unsuccessful ablation group; p = 0.056). In multivariate regression analysis, paroxysmal AF was the only independent predictor of a successful outcome. CONCLUSIONS: Catheter ablation of AF in patients with HCM is an effective and safe therapeutic option, particularly in patients with paroxysmal AF. Effectiveness of ablation is significantly smaller in patients with persistent AF and even more so in those with long-persistent AF. Repeated procedures were often necessary. Continued antiarrhythmic drug therapy is often required due to a significant degree of atrial remodelling.


Assuntos
Fibrilação Atrial/cirurgia , Cardiomiopatia Hipertrófica/complicações , Ablação por Cateter/métodos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/classificação , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/etiologia , Volume Cardíaco , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reoperação , Resultado do Tratamento
8.
Kardiol Pol ; 68(9): 1023-9, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20859894

RESUMO

BACKGROUND: Transvenous implantable cardioverter-defibrillators (ICD) have been implanted in Poland since 1995. As the method spreads it is important to consider its long-term benefits and disadvantages. AIM: To assess survival, efficacy and complication rate in ICD patients, who received the device more than ten years earlier. METHODS: Retrospective analysis of 60 ICD patients implanted between 1995-1999. RESULTS: There were 42 (70%) males, mean age 50.6 ± 16.4 years. In 59 patients ICD was implanted for sudden cardiac death (SCD) secondary prevention. Thirty eight patients (34 M, 63.3%) had coronary artery disease (CAD). The CAD was diagnosed in 89.5% of males and 10.5% of females (p〈 0.0001). Mean follow-up time was 75.4 ± 34.7 months. During this time 22 patients died (37%, 19 M, 3 F). Three deaths were SCD. Mean one-year mortality was 6.7%. Deaths were more frequent among males: 45.2% vs 16.7%, p〈 0.005. In CAD mortality was higher than in non-CAD patients (50% vs 13.6%, p〈 0.005). Appropriate ICD discharges in the ventricular fibrillation (VF) zone occurred in 35 (58%) patients, and in ventricular tachycardia (VT) zone - in 26 (43%) patients. Mean intervention rate per year was 3.7 for VF and 0.6 for VT. Complications occurred in 27 (45%) patients and 5 (8%) of them had no ICD intervention during follow-up. In 5 patients more than one complication was diagnosed. There were inappropriate discharges in 15 (25%) patients, 11 (18%) had electrical storm, and ICD-related infections were noted in 3 (5%) patients. During the perioperative period, lead revisions were done in 4 patients; in 3 with discharges induced by T-wave oversensing and in one with lead dislocation. Four cases of lead failure occurred during follow-up, requiring new lead implantation. In 4 patients, electrical storm (3 patients) and supraventricular tachycardia with ICD discharges (1 patient) were treated with radiofrequency ablation. Only 10 (17%) patients did not demonstrate any ICD interventions or ICD-related complications. CONCLUSIONS: 1. ICD interventions caused by malignant ventricular arrhythmias occurred in 75% patients with the device implanted more than 10 years earlier. 2. Almost a half of the analysed population suffered from complications and side effects related to implanted ICD and they were present in 8% of subjects without ICD intervention. Neither ICD interventions nor device-related adverse events were recorded in 17% of patients.


Assuntos
Doença da Artéria Coronariana/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Análise de Falha de Equipamento , Taquicardia Ventricular/mortalidade , Fibrilação Ventricular/mortalidade , Adulto , Idoso , Desfibriladores Implantáveis/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Polônia , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Análise de Sobrevida , Taquicardia Ventricular/etiologia , Fatores de Tempo , Fibrilação Ventricular/etiologia
9.
J Cardiovasc Electrophysiol ; 21(8): 877-82, 2010 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-20158563

RESUMO

AIMS: The goal of this study was to describe mapping and ablation of severe arrhythmias during pregnancy, with minimum or no X-ray exposure. Treatment of tachyarrhythmia in pregnancy is a clinical problem. Pharmacotherapy entails a risk of adverse effects and is unsuccessful in some patients. Radiofrequency ablation has been performed rarely, because of fetal X-ray exposure and potential maternal and fetus complications. GROUP AND METHOD: Mapping and ablation was performed in 9 women (age 24-34 years) at 12-38th week of pregnancy. Three had permanent junctional reciprocating tachycardia, and 2 had incessant atrial tachycardia. Four of them had left ventricular ejection fraction < or =45%. One patient had atrioventricular nodal reciprocating tachycardia requiring cardioversion. Three patients had Wolff-Parkinson-White syndrome. Two of them had atrial fibrillation with ventricular rate 300 bpm and 1 had atrioventricular tachycardia 300 bpm. Fetal echocardiography was performed before and after the procedure. RESULTS: Three women had an electroanatomic map and ablation done without X-ray exposure. The mean fluoroscopy time in the whole group was 42 +/- 37 seconds. The mean procedure time was 56 +/- 18 minutes. After the procedure, all women and fetuses were in good condition. After a mean period of 43 +/- 23 months follow up (FU), all patients were free of arrhythmia without complications related to ablation either in the mothers or children. CONCLUSION: Ablation can be performed safely with no or minimal radiation exposure during pregnancy. In the setting of malignant, drug-resistant arrhythmia, ablation may be considered a therapeutic option in selected cases.


Assuntos
Antiarrítmicos/uso terapêutico , Arritmias Cardíacas/cirurgia , Ablação por Cateter , Complicações Cardiovasculares na Gravidez/cirurgia , Adulto , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/tratamento farmacológico , Ablação por Cateter/efeitos adversos , Resistência a Medicamentos , Técnicas Eletrofisiológicas Cardíacas , Europa (Continente) , Feminino , Fluoroscopia , Idade Gestacional , Humanos , Gravidez , Complicações Cardiovasculares na Gravidez/diagnóstico , Complicações Cardiovasculares na Gravidez/tratamento farmacológico , Doses de Radiação , Medição de Risco , Índice de Gravidade de Doença , Austrália do Sul , Taquicardia Reciprocante/cirurgia , Taquicardia Supraventricular/cirurgia , Falha de Tratamento , Ultrassonografia Doppler , Ultrassonografia Pré-Natal , Síndrome de Wolff-Parkinson-White/cirurgia , Adulto Jovem
11.
Kardiol Pol ; 67(1): 95-100, 2009 Jan.
Artigo em Polonês | MEDLINE | ID: mdl-19253199

RESUMO

We describe a case of persistent atrial tachycardia/flutter in a 19-year old female with corrected transposition of great arteries (ccTGA) and dual inlet left ventricle (DILV), treated with surgical palliative operations. The arrhythmia became persistent and symptomatic with dyspnea and severe cyanosis. During the EP study, the right atrial isthmus-dependent reentry was identified. In electroanatomical maps large areas of low voltage and electrical silence were localised. Due to these areas of slow conduction the isthmus dependent arrhythmia had long CL. Linear RF applications closed the isthmus, resulting in flutter termination. During 3 months of follow-up the patient remained free of arrhythmia.


Assuntos
Fibrilação Atrial/etiologia , Flutter Atrial/etiologia , Mapeamento Potencial de Superfície Corporal/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ablação por Cateter/métodos , Cardiopatias Congênitas/cirurgia , Cuidados Paliativos , Fibrilação Atrial/terapia , Flutter Atrial/terapia , Diagnóstico por Computador/métodos , Feminino , Cardiopatias Congênitas/complicações , Humanos , Resultado do Tratamento , Adulto Jovem
12.
J Interv Card Electrophysiol ; 24(1): 67-70, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18758930

RESUMO

This report presents a case of a 31-year-old male with congenitally corrected transposition of the great arteries, ventricular septal defect (VSD) and complete heart block who was admitted to our institution because of an exacerbation of heart failure after pacemaker implantation. The ECG and chest radiograph revealed that the ventricular lead was placed in the middle cardiac vein. After cardiosurgical procedure (VSD closure and atrioventricular valves replacement), the clinical symptoms of heart failure were still present. They diminished while the patient was on escape rhythm (40-70 bpm). Therefore, the previously implanted leads were removed and the transvenous, biventricular system was implanted, which resulted in a significant clinical improvement.


Assuntos
Arritmias Cardíacas/prevenção & controle , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/prevenção & controle , Comunicação Interventricular/cirurgia , Transposição dos Grandes Vasos/cirurgia , Adulto , Comunicação Interventricular/complicações , Humanos , Masculino , Transposição dos Grandes Vasos/complicações , Resultado do Tratamento
13.
Kardiol Pol ; 66(11): 1233-8, 2008 Nov.
Artigo em Polonês | MEDLINE | ID: mdl-19105105

RESUMO

We present a case of a 54 year old male with a long-standing atrial fibrillation (AF) who was scheduled for cardiac transplantation due to the progression of heart failure. Previous treatment included pacemaker implantation, mitral valvuloplasty, a-v node modification using RF ablation, and pharmacological therapy. This time the patient underwent complex AF ablation which consisted of pulmonary vein isolation, mitral and left atrial roof line creation, cavo-tricuspid isthmus ablation and ablation of complex fractionated atrial electrograms, which resulted in restoration of sinus rhythm. Because of the right atrial post-incisional tachycardia the patient underwent second ablation session. This complex invasive approach occurred successful. The patient remains in sinus rhythm with improved left ventricular function and better NYHA class over a 12-month follow-up.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Insuficiência Cardíaca/complicações , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Fibrilação Atrial/complicações , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Taquicardia por Reentrada no Nó Atrioventricular/complicações
14.
Kardiol Pol ; 65(8): 893-8; discussion 899, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17853318

RESUMO

BACKGROUND: Implantation of a cardioverter-defibrillator (ICD) is a well-established method to prevent sudden cardiac death (SCD). Due to the expanding indications for this type of treatment and increasing survival of these patients, the ICD population is growing rapidly. AIM: To assess the rate and causes of reoperations in patients with ICD over a long-term (at least 4 years) follow-up period. METHODS: Between 1995 and 2006, an ICD was implanted in 598 patients. This study included all patients with a follow-up duration of at least 4 years and only those who underwent a repeat procedure later than 6 weeks after the index ICD implantation. RESULTS: The study group consisted of 174 patients with a mean age of 51+/-18 years who were followed for a mean of 6+/-1.7 years. Coronary artery disease (CAD) was diagnosed in 92 (53%) patients, and non-ischaemic cardiomyopathy in 82 (47%) patients. Prophylactic ICD therapy was instituted in 11 (6%) patients, whereas 163 (94%) patients received ICD for secondary prophylactics. During the follow-up period, 10 deaths occurred: 6 of all deaths (60%) in patients with CAD and 4 of all deaths (40%) in the non--ischaemic group. A total of 211 redo procedures in 139 patients were performed. Indications for repeat procedures included battery depletion in 136 patients, ICD malfunction in 37 cases, infection related to the implanted system in 5 patients, problems with leads in 19 cases, an upgrade to the dual-chamber system in 5 or to the biventricular system in 3 patients, and the revision of an ICD pocket in 6 patients. CONCLUSIONS: Repeat procedures in ICD recipients are frequent. The most common cause is battery depletion and ICD replacement indicated by a manufacturer. Improvement in ICD technology is essential to increase ICD longevity and decrease the redo-procedure rates. Patients with ICD should be regularly followed in experienced centres in order to detect ICD system failure early.


Assuntos
Cardiomiopatias/terapia , Doença da Artéria Coronariana/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Adulto , Idoso , Falha de Equipamento/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação
15.
Kardiol Pol ; 65(5): 603-7, 2007 May.
Artigo em Polonês | MEDLINE | ID: mdl-17577856

RESUMO

We present a case of 53-year-old patient who experienced paroxysms of wide QRS complex tachycardia at a rate of 150 bpm and LBBB morphology 6 years after inferior myocardial infarction and CABG. Anamnesis and morphology of tachycardia could suggest ventricular tachycardia. However during electrophysiological study we observed AVRT with LBBB and "regularly irregular" AVRT with normal QRS complex and changing entrance to the AV node (through slow and fast pathway). In this paper we present our approach and try to explain why the tachycardia using concealed bypass tract appeared so late in life.


Assuntos
Bloqueio de Ramo/diagnóstico , Ponte de Artéria Coronária/efeitos adversos , Eletrocardiografia , Infarto do Miocárdio/complicações , Taquicardia Paroxística/diagnóstico , Bloqueio de Ramo/etiologia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/cirurgia , Taquicardia Paroxística/etiologia , Taquicardia Paroxística/terapia
16.
Kardiol Pol ; 64(10): 1113-7, 2006 Oct.
Artigo em Polonês | MEDLINE | ID: mdl-17089244

RESUMO

The authors present a case of a 77-year-old man with heart failure in the course of dilated cardiomyopathy (DCM) and atrial fibrillation (AF), after implantation of an automatic cardioverter-defibrillator (ICD) due to recurrent symptomatic ventricular tachycardia (VT). Addition of cardiac resynchronization therapy (CRT) was decided due to the heart-failure dependent intensification of the arrhythmia and poststimulation enlargement of QRS. CRT was led to withdraw patient's arrhythmia and to improvement of the general condition of the patient for approximately one year. After the arrhythmia reoccurred due to dislocation of the electrode in the coronary sinus with loss of left ventricle stimulation. Multiple attempts at restoration of resynchronization function via a transvenous approach failed. The patient was qualified for implantation of an epicardial left ventricle electrode. The surgery was combined with a planned exchange of ICD-CRT. Basing on a 6-month observation period an improvement heart performance and general state of health have been observed. No arrhythmic event has been noted in device memory. Performed procedures are picturing the evolution of in pacing techniques and automatic defibrillation in Poland over recent years.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Cardioversão Elétrica , Eletrodos Implantados , Miocardite/etiologia , Idoso , Arritmias Cardíacas/etiologia , Fibrilação Atrial/complicações , Cardiomiopatia Dilatada/complicações , Eletrodos Implantados/efeitos adversos , Falha de Equipamento , Insuficiência Cardíaca/complicações , Humanos , Masculino , Marca-Passo Artificial , Polônia , Recidiva , Taquicardia Ventricular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA