1.
Phys Med Biol ; 69(4)2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38252974

RESUMO

Objectives. Evaluate the reproducibility, temperature tolerance, and radiation dose requirements of spectral CT thermometry in tissue-mimicking phantoms to establish its utility for non-invasive temperature monitoring of thermal ablations.Methods. Three liver mimicking phantoms embedded with temperature sensors were individually scanned with a dual-layer spectral CT at different radiation dose levels during heating (35 °C-80 °C). Physical density maps were reconstructed from spectral results using varying reconstruction parameters. Thermal volumetric expansion was then measured at each temperature sensor every 5 °C in order to establish a correlation between physical density and temperature. Linear regressions were applied based on thermal volumetric expansion for each phantom, and coefficient of variation for fit parameters was calculated to characterize reproducibility of spectral CT thermometry. Additionally, temperature tolerance was determined to evaluate effects of acquisition and reconstruction parameters. The resulting minimum radiation dose to meet the clinical temperature accuracy requirement was determined for each slice thickness with and without additional denoising.Results. Thermal volumetric expansion was robustly replicated in all three phantoms, with a correlation coefficient variation of only 0.43%. Similarly, the coefficient of variation for the slope and intercept were 9.6% and 0.08%, respectively, indicating reproducibility of the spectral CT thermometry. Temperature tolerance ranged from 2 °C to 23 °C, decreasing with increased radiation dose, slice thickness, and iterative reconstruction level. To meet the clinical requirement for temperature tolerance, the minimum required radiation dose ranged from 20, 30, and 57 mGy for slice thickness of 2, 3, and 5 mm, respectively, but was reduced to 2 mGy with additional denoising.Conclusions. Spectral CT thermometry demonstrated reproducibility across three liver-mimicking phantoms and illustrated the clinical requirement for temperature tolerance can be met for different slice thicknesses. The reproducibility and temperature accuracy of spectral CT thermometry enable its clinical application for non-invasive temperature monitoring of thermal ablation.


Assuntos
Termometria , Reprodutibilidade dos Testes , Termometria/métodos , Temperatura , Fígado/diagnóstico por imagem , Fígado/cirurgia , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
2.
J Appl Clin Med Phys ; 20(1): 237-249, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30597725

RESUMO

PURPOSE: As computed tomography (CT) imaging is the most commonly used modality for treatment planning in radiation therapy, metal artifacts in the planning CT images may complicate the target delineation and reduce the dose calculation accuracy. Although current CT scanners do provide certain correction steps, it is a common understanding that there is not a universal solution yet to the metal artifact reduction (MAR) in general. Particularly noting the importance of MAR for radiation treatment planning, we propose a novel MAR method in this work that recruits an additional tilted CT scan and synthesizes nearly metal-artifact-free CT images. METHODS: The proposed method is based on the facts that the most pronounced metal artifacts in CT images show up along the x-ray beam direction traversing multiple metallic objects and that a tilted CT scan can provide complementary information free of such metal artifacts in the earlier scan. Although the tilted CT scan would contain its own metal artifacts in the images, the artifacts may manifest in a different fashion leaving a chance to concatenate the two CT images with the metal artifacts much suppressed. We developed an image processing technique that uses the structural similarity (SSIM) for suppressing the metal artifacts. On top of the additional scan, we proposed to use an existing MAR method for each scan if necessary to further suppress the metal artifacts. RESULTS: The proposed method was validated by a simulation study using the pelvic region of an XCAT numerical phantom and also by an experimental study using the head part of the Rando phantom. The proposed method was found to effectively reduce the metal artifacts. Quantitative analyses revealed that the proposed method reduced the mean absolute percentages of the error by up to 86% and 89% in the simulation and experimental studies, respectively. CONCLUSIONS: It was confirmed that the proposed method, using complementary information acquired from an additional tilted CT scan, can provide nearly metal-artifact-free images for the treatment planning.


Assuntos
Metais , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Órgãos em Risco/efeitos da radiação , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/normas , Artefatos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos
3.
Healthc Inform Res ; 22(4): 316-325, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27895964

RESUMO

OBJECTIVES: With the increased use of computed tomography (CT) in clinics, dose reduction is the most important feature people seek when considering new CT techniques or applications. We developed an intensity-weighted region-of-interest (IWROI) imaging method in an exact half-fan geometry to reduce the imaging radiation dose to patients in cone-beam CT (CBCT) for image-guided radiation therapy (IGRT). While dose reduction is highly desirable, preserving the high-quality images of the ROI is also important for target localization in IGRT. METHODS: An intensity-weighting (IW) filter made of copper was mounted in place of a bowtie filter on the X-ray tube unit of an on-board imager (OBI) system such that the filter can substantially reduce radiation exposure to the outer ROI. In addition to mounting the IW filter, the lead-blade collimation of the OBI was adjusted to produce an exact half-fan scanning geometry for a further reduction of the radiation dose. The chord-based rebinned backprojection-filtration (BPF) algorithm in circular CBCT was implemented for image reconstruction, and a humanoid pelvis phantom was used for the IWROI imaging experiment. RESULTS: The IWROI image of the phantom was successfully reconstructed after beam-quality correction, and it was registered to the reference image within an acceptable level of tolerance. Dosimetric measurements revealed that the dose is reduced by approximately 61% in the inner ROI and by 73% in the outer ROI compared to the conventional bowtie filter-based half-fan scan. CONCLUSIONS: The IWROI method substantially reduces the imaging radiation dose and provides reconstructed images with an acceptable level of quality for patient setup and target localization. The proposed half-fan-based IWROI imaging technique can add a valuable option to CBCT in IGRT applications.