Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Anal Biochem ; 685: 115389, 2024 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-37951455

RESUMO

Cell and gene therapy is a fast-growing field for cancer therapeutics requiring reliable instrumentation and technologies. Key parameters essential for satisfying Chemistry Manufacturing and Controls criteria standards are routinely performed using flow cytometry. Recently, image cytometry was developed for cell characterization and cell-based assays but had not yet demonstrated sufficient sensitivity for surface marker detection. We developed the Cellaca® PLX image cytometry system and the respective methodologies required for immunophenotyping, GFP and RFP transfection/transduction efficiencies, and cell health analyses for routine cell characterization. All samples tested were compared directly to results from the CytoFLEX flow cytometer. PBMCs were stained with T-cell surface markers for immunophenotyping, and results show highly comparable CD3, CD4, and CD8 populations (within 5 %). GFP- or RFP-expressing cell lines were analyzed for transfection/transduction efficiencies, and the percentage positive cells and respective viabilities were equivalent on both systems. Staurosporine-treated Jurkat cells were stained for apoptotic markers, where annexin V and caspase-3 positive cells were within 5 % comparing both instruments. The proposed system may provide a complementary tool for performing routine cell-based experiments with improved efficiency and sensitivity compared to prior image cytometers, which may be significantly valuable to the cell and gene therapy field.


Assuntos
Apoptose , Humanos , Imunofenotipagem , Transfecção , Linhagem Celular , Células Jurkat , Citometria de Fluxo/métodos
2.
PLoS One ; 15(1): e0227950, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31978129

RESUMO

Trypan blue has long been the gold standard for staining dead cell to determine cell viability. The dye is excluded from membrane-intact live cells, but can enter and concentrate in membrane-compromised dead cells, rendering the cells dark blue. Over the years, there has been an understanding that trypan blue is inaccurate for cell viability under 80% without scientific support. We previously showed that trypan blue can alter the morphology of dead cells to a diffuse shape, which can lead to over-estimation of viability. Here, we investigate the origin of the dim and diffuse objects after trypan blue staining. Utilizing image and video acquisition, we show real-time transformation of cells into diffuse objects when stained with trypan blue. The same phenomenon was not observed when staining cells with propidium iodide. We also demonstrate the co-localization of trypan blue and propidium iodide, confirming these diffuse objects as cells that contain nuclei. The videos clearly show immediate cell rupturing after trypan blue contact. The formation of these diffuse objects was monitored and counted over time as cells die outside of the incubator. We hypothesize and demonstrate that rapid water influx may have caused the cells to rupture and disappear. Since some dead cells disappear after trypan blue staining, the total can be under-counted, leading to over-estimation of cell viability. This inaccuracy could affect the outcomes of cellular therapies, which require accurate measurements of immune cells that will be infused back into patients.


Assuntos
Sobrevivência Celular/efeitos dos fármacos , Corantes/farmacologia , Células Epiteliais/efeitos dos fármacos , Azul Tripano/farmacologia , Morte Celular/fisiologia , Rastreamento de Células/métodos , Células Epiteliais/ultraestrutura , Humanos , Iodetos/farmacologia , Células Jurkat , Imagem Óptica , Coloração e Rotulagem/métodos
3.
J Vis Exp ; (144)2019 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-30799861

RESUMO

Tumor spheroids have been developed as a three-dimensional (3D) cell culture model in cancer research and anti-cancer drug discovery. However, currently, high-throughput imaging modalities utilizing bright field or fluorescence detection, are unable to resolve the overall 3D structure of the tumor spheroid due to limited light penetration, diffusion of fluorescent dyes and depth-resolvability. Recently, our lab demonstrated the use of optical coherence tomography (OCT), a label-free and non-destructive 3D imaging modality, to perform longitudinal characterization of multicellular tumor spheroids in a 96-well plate. OCT was capable of obtaining 3D morphological and physiological information of tumor spheroids growing up to about 600 µm in height. In this article, we demonstrate a high-throughput OCT (HT-OCT) imaging system that scans the whole multi-well plate and obtains 3D OCT data of tumor spheroids automatically. We describe the details of the HT-OCT system and construction guidelines in the protocol. From the 3D OCT data, one can visualize the overall structure of the spheroid with 3D rendered and orthogonal slices, characterize the longitudinal growth curve of the tumor spheroid based on the morphological information of size and volume, and monitor the growth of the dead-cell regions in the tumor spheroid based on optical intrinsic attenuation contrast. We show that HT-OCT can be used as a high-throughput imaging modality for drug screening as well as characterizing biofabricated samples.


Assuntos
Imageamento Tridimensional/métodos , Monitorização Fisiológica , Neoplasias/patologia , Esferoides Celulares/patologia , Tomografia de Coerência Óptica/métodos , Humanos , Células Tumorais Cultivadas
4.
SLAS Discov ; 23(2): 202-210, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28915356

RESUMO

Three-dimensional tumor spheroid models have been increasingly used to investigate and characterize cancer drug compounds. Previously, the Celigo image cytometer has demonstrated its utility in a high-throughput screening manner for evaluating potential drug candidates in a 3D multicellular tumor spheroid (MCTS) primary screen. In addition, we have developed real-time kinetic caspase 3/7 apoptosis and propidium iodide viability 3D MCTS assays, both of which can be used in a secondary screen to better characterize the hit compounds. In this work, we monitored the kinetic apoptotic and cytotoxic effects of 14 compounds in 3D MCTS produced from the glioblastoma cell line U87MG in 384-well plates for 9 days. The kinetic results allowed the categorization of the effects from 14 drug compounds into early and late cytotoxic, apoptotic, cytostatic, and no effects. The real-time apoptosis and viability screening method can serve as an improved secondary screen to better understand the mechanism of action of these potential drug candidates identified from the primary screen, allowing one to identify a more qualified drug candidate and streamline the drug discovery process of research and development.


Assuntos
Antineoplásicos/farmacologia , Apoptose/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Ensaios de Triagem em Larga Escala/métodos , Citometria por Imagem/métodos , Esferoides Celulares/efeitos dos fármacos , Técnicas de Cultura de Células/métodos , Linhagem Celular Tumoral , Descoberta de Drogas/métodos , Ensaios de Seleção de Medicamentos Antitumorais/métodos , Glioblastoma/tratamento farmacológico , Humanos
5.
Cancer Res ; 77(21): 6011-6020, 2017 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-28904062

RESUMO

Three-dimensional (3D) tumor spheroid models have gained increased recognition as important tools in cancer research and anticancer drug development. However, currently available imaging approaches used in high-throughput screening drug discovery platforms, for example, bright-field, phase contrast, and fluorescence microscopies, are unable to resolve 3D structures deep inside (>50 µm) tumor spheroids. In this study, we established a label-free, noninvasive optical coherence tomography (OCT) imaging platform to characterize 3D morphologic and physiologic information of multicellular tumor spheroids (MCTS) growing from approximately 250 to 600 µm in height over 21 days. In particular, tumor spheroids of two cell lines, glioblastoma (U-87MG) and colorectal carcinoma (HCT116), exhibited distinctive evolutions in their geometric shapes at late growth stages. Volumes of MCTS were accurately quantified using a voxel-based approach without presumptions of their geometries. In contrast, conventional diameter-based volume calculations assuming perfect spherical shape resulted in large quantification errors. Furthermore, we successfully detected necrotic regions within these tumor spheroids based on increased intrinsic optical attenuation, suggesting a promising alternative of label-free viability tests in tumor spheroids. Therefore, OCT can serve as a promising imaging modality to characterize morphologic and physiologic features of MCTS, showing great potential for high-throughput drug screening. Cancer Res; 77(21); 6011-20. ©2017 AACR.


Assuntos
Imageamento Tridimensional/métodos , Neoplasias/diagnóstico por imagem , Esferoides Celulares/patologia , Tomografia de Coerência Óptica/métodos , Técnicas de Cultura de Células/métodos , Linhagem Celular Tumoral , Sobrevivência Celular , Células HCT116 , Humanos , Necrose , Reprodutibilidade dos Testes , Fatores de Tempo
6.
Cytometry A ; 91(9): 883-892, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28618188

RESUMO

The development of three-dimensional (3D) multicellular tumor spheroid models for cancer drug discovery research has increased in the recent years. The use of 3D tumor spheroid models may be more representative of the complex in vivo tumor microenvironments in comparison to two-dimensional (2D) assays. Currently, viability of 3D multicellular tumor spheroids has been commonly measured on standard plate-readers using metabolic reagents such as CellTiter-Glo® for end point analysis. Alternatively, high content image cytometers have been used to measure drug effects on spheroid size and viability. Previously, we have demonstrated a novel end point drug screening method for 3D multicellular tumor spheroids using the Celigo Image Cytometer. To better characterize the cancer drug effects, it is important to also measure the kinetic cytotoxic and apoptotic effects on 3D multicellular tumor spheroids. In this work, we demonstrate the use of PI and caspase 3/7 stains to measure viability and apoptosis for 3D multicellular tumor spheroids in real-time. The method was first validated by staining different types of tumor spheroids with PI and caspase 3/7 and monitoring the fluorescent intensities for 16 and 21 days. Next, PI-stained and nonstained control tumor spheroids were digested into single cell suspension to directly measure viability in a 2D assay to determine the potential toxicity of PI. Finally, extensive data analysis was performed on correlating the time-dependent PI and caspase 3/7 fluorescent intensities to the spheroid size and necrotic core formation to determine an optimal starting time point for cancer drug testing. The ability to measure real-time viability and apoptosis is highly important for developing a proper 3D model for screening tumor spheroids, which can allow researchers to determine time-dependent drug effects that usually are not captured by end point assays. This would improve the current tumor spheroid analysis method to potentially better identify more qualified cancer drug candidates for drug discovery research. © 2017 International Society for Advancement of Cytometry.


Assuntos
Apoptose/fisiologia , Sobrevivência Celular/fisiologia , Esferoides Celulares/fisiologia , Células A549 , Antineoplásicos/farmacologia , Apoptose/efeitos dos fármacos , Caspase 3/metabolismo , Caspase 7/metabolismo , Técnicas de Cultura de Células/métodos , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Descoberta de Drogas/métodos , Ensaios de Seleção de Medicamentos Antitumorais , Células HT29 , Humanos , Citometria por Imagem/métodos , Cinética , Esferoides Celulares/efeitos dos fármacos , Esferoides Celulares/metabolismo , Microambiente Tumoral/efeitos dos fármacos , Microambiente Tumoral/fisiologia
7.
SLAS Discov ; 22(5): 547-557, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28346096

RESUMO

Three-dimensional (3D) tumor models have been increasingly used to investigate and characterize cancer drug compounds. The ability to perform high-throughput screening of 3D multicellular tumor spheroids (MCTS) can highly improve the efficiency and cost-effectiveness of discovering potential cancer drug candidates. Previously, the Celigo Image Cytometer has demonstrated a novel method for high-throughput screening of 3D multicellular tumor spheroids. In this work, we employed the Celigo Image Cytometer to examine the effects of 14 cancer drug compounds on 3D MCTS of the glioblastoma cell line U87MG in 384-well plates. Using parameters such as MCTS diameter and invasion area, growth and invasion were monitored for 9 and 3 d, respectively. Furthermore, fluorescent staining with calcein AM, propidium iodide, Hoechst 33342, and caspase 3/7 was performed at day 9 posttreatment to measure viability and apoptosis. Using the kinetic and endpoint data generated, we created a novel multiparametric drug-scoring system for 3D MCTS that can be used to identify and classify potential drug candidates earlier in the drug discovery process. Furthermore, the combination of quantitative and qualitative image data can be used to delineate differences between drugs that induce cytotoxic and cytostatic effects. The 3D MCTS-based multiparametric scoring method described here can provide an alternative screening method to better qualify tested drug compounds.


Assuntos
Antineoplásicos/farmacologia , Técnicas de Cultura de Células/métodos , Ensaios de Seleção de Medicamentos Antitumorais/métodos , Ensaios de Triagem em Larga Escala/métodos , Esferoides Celulares/efeitos dos fármacos , Apoptose/efeitos dos fármacos , Caspases/metabolismo , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Descoberta de Drogas/métodos , Humanos , Citometria por Imagem/métodos , Esferoides Celulares/metabolismo
8.
SLAS Technol ; 22(4): 454-465, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-27272155

RESUMO

Oncologists have investigated the effect of protein or chemical-based compounds on cancer cells to identify potential drug candidates. Traditionally, the growth inhibitory and cytotoxic effects of the drugs are first measured in 2D in vitro models, and then further tested in 3D xenograft in vivo models. Although the drug candidates can demonstrate promising inhibitory or cytotoxicity results in a 2D environment, similar effects may not be observed under a 3D environment. In this work, we developed an image-based high-throughput screening method for 3D tumor spheroids using the Celigo image cytometer. First, optimal seeding density for tumor spheroid formation was determined by investigating the cell seeding density of U87MG, a human glioblastoma cell line. Next, the dose-response effects of 17-AAG with respect to spheroid size and viability were measured to determine the IC50 value. Finally, the developed high-throughput method was used to measure the dose response of four drugs (17-AAG, paclitaxel, TMZ, and doxorubicin) with respect to the spheroid size and viability. Each experiment was performed simultaneously in the 2D model for comparison. This detection method allowed for a more efficient process to identify highly qualified drug candidates, which may reduce the overall time required to bring a drug to clinical trial.


Assuntos
Antineoplásicos/farmacologia , Avaliação Pré-Clínica de Medicamentos/métodos , Ensaios de Triagem em Larga Escala , Citometria por Imagem/métodos , Esferoides Celulares , Linhagem Celular Tumoral , Humanos , Concentração Inibidora 50
9.
Cytotechnology ; 68(5): 2015-25, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27488883

RESUMO

To ensure cell-based assays are performed properly, both cell concentration and viability have to be determined so that the data can be normalized to generate meaningful and comparable results. Cell-based assays performed in immuno-oncology, toxicology, or bioprocessing research often require measuring of multiple samples and conditions, thus the current automated cell counter that uses single disposable counting slides is not practical for high-throughput screening assays. In the recent years, a plate-based image cytometry system has been developed for high-throughput biomolecular screening assays. In this work, we demonstrate a high-throughput AO/PI-based cell concentration and viability method using the Celigo image cytometer. First, we validate the method by comparing directly to Cellometer automated cell counter. Next, cell concentration dynamic range, viability dynamic range, and consistency are determined. The high-throughput AO/PI method described here allows for 96-well to 384-well plate samples to be analyzed in less than 7 min, which greatly reduces the time required for the single sample-based automated cell counter. In addition, this method can improve the efficiency for high-throughput screening assays, where multiple cell counts and viability measurements are needed prior to performing assays such as flow cytometry, ELISA, or simply plating cells for cell culture.

10.
Cancer Metab ; 1(1): 20, 2013 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-24279929

RESUMO

BACKGROUND: Although cells require nutrients to proliferate, most nutrient exchange rates of the NCI60 panel of cancer cell lines correlate poorly with their proliferation rate. Here, we provide evidence indicating that this inconsistency is rooted in the variability of cell size. RESULTS: We integrate previously reported data characterizing genome copy number variations, gene expression, protein expression and exchange fluxes with our own measurements of cell size and protein content in the NCI60 panel of cell lines. We show that protein content, DNA content, and protein synthesis per cell are proportional to the cell volume, and that larger cells proliferate slower than smaller cells. We estimate the metabolic fluxes of these cell lines and show that their magnitudes are proportional to their protein synthesis rate and, after correcting for cell volume, to their proliferation rate. At the level of gene expression, we observe that genes expressed at higher levels in smaller cells are enriched for genes involved in cell cycle, while genes expressed at higher levels in large cells are enriched for genes expressed in mesenchymal cells. The latter finding is further corroborated by the induction of those same genes following treatment with TGFß, and the high vimentin but low E-cadherin protein levels in the larger cells. We also find that aromatase inhibitors, statins and mTOR inhibitors preferentially inhibit the in vitro growth of cancer cells with high protein synthesis rates per cell. CONCLUSIONS: The NCI60 cell lines display various metabolic activities, and the type of metabolic activity that they possess correlates with their cell volume and protein content. In addition to cell proliferation, cell volume and/or biomarkers of protein synthesis may predict response to drugs targeting cancer metabolism.

11.
J Immunol Methods ; 388(1-2): 25-32, 2013 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-23201386

RESUMO

Peripheral blood mononuclear cells (PBMCs) have been widely researched in the fields of immunology, infectious disease, oncology, transplantation, hematological malignancy, and vaccine development. Specifically, in immunology research, PBMCs have been utilized to monitor concentration, viability, proliferation, and cytokine production from immune cells, which are critical for both clinical trials and biomedical research. The viability and concentration of isolated PBMCs are traditionally measured by manual counting with trypan blue (TB) using a hemacytometer. One of the common issues of PBMC isolation is red blood cell (RBC) contamination. The RBC contamination can be dependent on the donor sample and/or technical skill level of the operator. RBC contamination in a PBMC sample can introduce error to the measured concentration, which can pass down to future experimental assays performed on these cells. To resolve this issue, RBC lysing protocol can be used to eliminate potential error caused by RBC contamination. In the recent years, a rapid fluorescence-based image cytometry system has been utilized for bright-field and fluorescence imaging analysis of cellular characteristics (Nexcelom Bioscience LLC, Lawrence, MA). The Cellometer image cytometry system has demonstrated the capability of automated concentration and viability detection in disposable counting chambers of unpurified mouse splenocytes and PBMCs stained with acridine orange (AO) and propidium iodide (PI) under fluorescence detection. In this work, we demonstrate the ability of Cellometer image cytometry system to accurately measure PBMC concentration, despite RBC contamination, by comparison of five different total PBMC counting methods: (1) manual counting of trypan blue-stained PBMCs in hemacytometer, (2) manual counting of PBMCs in bright-field images, (3) manual counting of acetic acid lysing of RBCs with TB-stained PBMCs, (4) automated counting of acetic acid lysing of RBCs with PI-stained PBMCs, and (5) AO/PI dual staining method. The results show comparable total PBMC counting among all five methods, which validate the AO/PI staining method for PBMC measurement in the image cytometry method.


Assuntos
Contagem de Células Sanguíneas/métodos , Eritrócitos/citologia , Citometria por Imagem/métodos , Leucócitos Mononucleares/química , Leucócitos Mononucleares/citologia , Laranja de Acridina/química , Eritrócitos/química , Humanos , Propídio/química
12.
Cytometry A ; 79(7): 507-17, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21538841

RESUMO

Cell phenotyping and cell cycle analysis are two commonly used assays in both clinical diagnosis and biomedical research. Cell phenotyping by identifying different biomarkers is essential for the diagnosis of hematologic malignancy, sub-classifying diseases, monitoring response to treatment, predicting prognosis, detecting rare cell populations and residual malignant cells. Cell cycle analysis distinguishes cells in different phases of cell cycle and is often used to determine the cellular response to drugs and biological stimulations. These assays have been traditionally carried out by sensitive fluorescence detection methods such as flow cytometry and laser scanning cytometry for fluorescence-based cell population analysis. However, these instruments remain relatively expensive, large in size, and require a considerable amount of maintenance, which may not be feasible for smaller research groups that do not have access to these equipments or field clinics that require quick diagnostic results on site. Recently, a small portable imaging cytometry system (Cellometer Vision) has been developed by Nexcelom Bioscience LLC (Lawrence, MA) for automated cell concentration and viability measurement using bright-field and fluorescent imaging methods. Here we report new applications of the Cellometer imaging cytometry for fluorescence-based cell population analysis and compared them with conventional flow cytometry. Cell population analysis assays such as immunophenotyping, cell cycle, and mitochondrial membrane potential detection methods have not yet been reported for the Cellometer Vision system. Using this imaging cytometry method for fluorescence-based assays that are typically done by flow cytometry offers a quick, simple, and inexpensive alternative method for biomedical research, which may be beneficial for smaller research laboratories and clinics.


Assuntos
Ciclo Celular/fisiologia , Citometria de Fluxo/métodos , Citometria por Imagem/métodos , Imunofenotipagem/métodos , Potencial da Membrana Mitocondrial/fisiologia , Animais , Citometria de Fluxo/instrumentação , Citometria por Imagem/instrumentação , Camundongos , Camundongos Endogâmicos BALB C , Baço/citologia , Timo/citologia
13.
J Pharmacol Toxicol Methods ; 63(3): 217-22, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21112407

RESUMO

INTRODUCTION: The ATP-binding cassette (ABC) transporters P-glycoprotein (P-gp/ABCB1), multidrug resistance-associated protein 1 (MRP1/ABCC1), and breast cancer resistance protein (BCRP/ABCG2) are known to transport a wide range of structurally diverse compounds. Their high level of expression at the blood-brain, maternal-fetal, and blood-testis barriers as well as their purported roles in oral absorption suggests that ABC transporters play important pharmacologic roles. METHODS: We have developed a method to characterize the function and inhibition of ABC transporters using an automated cell counter with fluorescence detection capability. The assay was performed using stably-transfected HEK293 cells expressing P-gp, MRP1, or ABCG2 and examining transport of fluorescent substrates in the presence or absence of known inhibitors and compared to results obtained with a flow cytometer. Fold increase in intracellular fluorescence was then calculated for cells incubated with fluorescent substrate in the absence of inhibitor versus in the presence of inhibitor. RESULTS: Fold increase values obtained either with the cell counter or flow cytometer were comparable for cells expressing either MRP1 or ABCG2; slightly higher fold increase values were observed when cells expressing P-gp were read on a flow cytometer compared to the cell counter. DISCUSSION: The assay described provides an inexpensive detection method to aid in the development of novel ABC transporter inhibitors or to characterize potential drug-drug interactions.


Assuntos
Membro 1 da Subfamília B de Cassetes de Ligação de ATP/antagonistas & inibidores , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/metabolismo , Transportadores de Cassetes de Ligação de ATP/antagonistas & inibidores , Transportadores de Cassetes de Ligação de ATP/metabolismo , Bioensaio/métodos , Descoberta de Drogas/métodos , Proteínas de Neoplasias/antagonistas & inibidores , Proteínas de Neoplasias/metabolismo , Subfamília B de Transportador de Cassetes de Ligação de ATP , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/genética , Membro 2 da Subfamília G de Transportadores de Cassetes de Ligação de ATP , Transportadores de Cassetes de Ligação de ATP/genética , Transporte Biológico/efeitos dos fármacos , Linhagem Celular , Ciclosporinas/farmacologia , Interações Medicamentosas , Citometria de Fluxo , Corantes Fluorescentes/farmacocinética , Humanos , Indóis/farmacologia , Proteínas de Neoplasias/genética , Propionatos/farmacologia , Quinolinas/farmacologia , Especificidade por Substrato , Transfecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA