Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Gastroenterol Hepatol ; 39(6): 1008-1015, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38326979

RESUMO

BACKGROUND AND AIM: The study aims to evaluate the feasibility of body mass index (BMI)-based individualized small bowel preparation for computed tomography enterography (CTE). METHODS: In this prospective randomized controlled study, patients undergoing CTE were randomly assigned to the individualized group or standardized group. Those in individualized group were given different volumes of mannitol solution based on BMI (1000 mL for patients with BMI < 18.5 kg/m2, 1500 mL for patients with 18.5 kg/m2 ≤ BMI < 25 kg/m2 and 2000 mL for patients with BMI ≥ 25 kg/m2) while patients in the standardized group were all asked to consume 1500-mL mannitol solution. CTE images were reviewed by two experienced radiologists blindly. Each segment of the small bowel was assessed for small bowel image quality and disease detection rates. Patients were invited to record a diary regarding adverse events and acceptance. RESULTS: A total of 203 patients were enrolled and randomly divided into two groups. For patients with BMI < 18.5 kg/m2, 1000-mL mannitol solution permitted a significantly lower rate of flatulence (P = 0.045) and defecating frequency (P = 0.011) as well as higher acceptance score (P = 0.015), but did not affect bowel image quality and diseases detection compared with conventional dosage. For patients with BMI ≥ 25 kg/m2, 2000-mL mannitol solution provided better overall image quality (P = 0.033) but comparable rates of adverse events and patients' acceptance compared with conventional dosage. CONCLUSIONS: Individualized bowel preparation could achieve both satisfactory image quality and patients' acceptance thus might be an acceptable alternative in CTE.


Assuntos
Índice de Massa Corporal , Intestino Delgado , Manitol , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Estudos Prospectivos , Pessoa de Meia-Idade , Manitol/administração & dosagem , Manitol/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Intestino Delgado/diagnóstico por imagem , Adulto , Idoso , Estudos de Viabilidade , Catárticos/administração & dosagem , Catárticos/efeitos adversos , Medicina de Precisão
2.
J Gastroenterol Hepatol ; 38(6): 962-969, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37094943

RESUMO

BACKGROUND AND AIM: Lugol chromoendoscopy is the standard technique to detect an esophageal squamous cell carcinoma (ESCC). However, a high concentration of Lugol's solution can induce mucosal injury and adverse events. We aimed to investigate the optimal concentration of Lugol's solution to reduce mucosal injury and adverse events without degrading image quality. METHODS: This was a two-phase double-blind randomized controlled trial. In phase I, 200 eligible patients underwent esophagogastroduodenoscopy and then were randomly (1:1:1:1:1) sprayed with 1.2%, 1.0%, 0.8%, 0.6%, or 0.4% Lugol's solution. Image quality, gastric mucosal injury, adverse events, and operation satisfaction were compared to investigate the minimal effective concentration. In phase II, 42 cases of endoscopic mucosectomy for early ESCC were included. The patients were randomly assigned (1:1) to the minimal effective (0.6%) or conventional (1.2%) concentration of Lugol's solution for further comparison of the effectiveness. RESULTS: In phase I, the gastric mucosal injury was significantly reduced in 0.6% group (P < 0.05). Furthermore, there was no statistical significance in image quality between 0.6% and higher concentrations of Lugol's solution (P > 0.05, respectively). It also showed that the operation satisfaction decreased in 1.2% group compared with the lower concentration groups (P < 0.05). In phase II, the complete resection rate was 100% in both groups, while 0.6% Lugol's solution showed higher operation satisfaction (W = 554.500, P = 0.005). CONCLUSIONS: The study indicates that 0.6% might be the optimal concentration of Lugol's solution for early detection and delineation of ESCC, considering minimal mucosal injury and satisfied image. The registry of clinical trials: ClinicalTrials.gov (NCT03180944).


Assuntos
Neoplasias Esofágicas , Carcinoma de Células Escamosas do Esôfago , Humanos , Neoplasias Esofágicas/patologia , Esofagoscopia/métodos , Corantes
3.
Helicobacter ; 27(2): e12880, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35150600

RESUMO

BACKGROUND: Helicobacter pylori (H. pylori) infections are of serious concern due to the associated risk of gastric cancer. However, many patients have poor medication and therapy compliance, which makes it difficult to eradicate their infections. This points to the need for stronger educational interventions aimed at enhancing compliance, thus increasing the potential for treatment success. As such, this study conducted a meta-analysis to clarify the effects of enhanced patient education (EPE) programs for H. pylori. MATERIALS AND METHODS: We searched electronic databases (PubMed, EMBASE, Web of Science, and Cochrane Library) for randomized controlled trials (RCTs) on health education for patients infected with H. pylori from inception to June 2021. The primary outcome was the eradication rate of H. pylori, while the secondary outcomes included the incidence of individual adverse symptoms, treatment compliance, clinical symptom remission after treatment, and patient satisfaction. We used the fixed or random-effects model to pool the risk ratio (RR), with 95% confidence interval. We also conducted sensitivity and subgroup analyses. RESULTS: Our search returned seven relevant studies across a total of 1,433 patients. Compared with controls, EPE was significantly associated with improved H. pylori eradication rates (RR = 1.16, 95%CI: 1.04-1.29, p = 0.006) and patient compliance (RR = 1.48, 95%CI: 1.14-1.93, p = 0.003). A subgroup analysis also showed that EPE benefits were consistent across patients with different eradication programs, WeChat intervention plans, and intervention frequencies (p < 0.05). However, there were no significant differences in the total adverse effects, common side effects (diarrhea, nausea, abdominal pain, taste disorder, and skin rash), or discontinuation rate (p > 0.05). CONCLUSIONS: Patient education is inexpensive, safe, and convenient. In this context, our findings suggest that enhanced educational interventions have positive effects on both the H. pylori eradication rate and adherence among infected patients, and thus constitute promising complements to clinical treatment regimens.


Assuntos
Infecções por Helicobacter , Helicobacter pylori , Neoplasias Gástricas , Antibacterianos/farmacologia , Quimioterapia Combinada , Infecções por Helicobacter/diagnóstico , Humanos , Neoplasias Gástricas/tratamento farmacológico
5.
Dig Endosc ; 33(7): 1075-1084, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33275789

RESUMO

BACKGROUND AND AIMS: Endoscopic diagnosis of early esophageal squamous cell cancer (ESCC) is complicated and dependent on operators' experience. This study aimed to develop an artificial intelligence (AI) model for automatic diagnosis of early ESCC. METHODS: Non-magnifying and magnifying endoscopic images of normal/noncancerous lesions, early ESCC, and advanced esophageal cancer (AEC) were retrospectively obtained from Qilu Hospital of Shandong University. A total of 10,988 images from 5075 cases were chosen for training and validation. Another 2309 images from 1055 cases were collected for testing. One hundred and four real-time videos were also collected to evaluate the diagnostic performance of the AI model. The diagnostic performance of the AI model was compared with endoscopists by magnifying images and the assistant efficiency of the AI model for novices was evaluated. RESULTS: The AI diagnosis for non-magnifying images showed a per-patient accuracy, sensitivity, and specificity of 99.5%, 100%, 99.5% for white light imaging, and 97.0%, 97.2%, 96.4% for optical enhancement/iodine straining images. Regarding diagnosis for magnifying images, the per-patient accuracy, sensitivity, and specificity were 88.1%, 90.9%, and 85.0%. The diagnostic accuracy of the AI model was similar to experts (84.5%, P = 0.205) and superior to novices (68.5%, P = 0.005). The diagnostic performance of novices was significantly improved by AI assistance. When it comes to the diagnosis for real-time videos, the AI model showed acceptable performance as well. CONCLUSIONS: The AI model could accurately recognize early ESCC among noncancerous mucosa and AEC. It could be a potential assistant for endoscopists, especially for novices.


Assuntos
Carcinoma de Células Escamosas , Neoplasias Esofágicas , Inteligência Artificial , Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias Esofágicas/diagnóstico por imagem , Humanos , Imagem de Banda Estreita , Estudos Retrospectivos
6.
J Gastroenterol Hepatol ; 35(12): 2066-2073, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32562282

RESUMO

BACKGROUND AND AIMS: Add-on devices have been widely used in clinical practice. The aim of this meta-analysis was to compare the adenoma detection rate between Endocuff-assisted colonoscopy (EAC) and cap-assisted colonoscopy (CAC). METHODS: PubMed, EMBASE, SCOPUS, and Cochrane databases were searched. Outcomes included adenoma detection rate, cecal intubation rate, cecal intubation time, and withdrawal time. Dichotomous data were pooled to obtain the odds ratio or risk ratio. Continuous data were pooled using the mean difference. RESULTS: Of the 240 articles reviewed, six randomized controlled trials were included, with a total of 1994 patients. In the meta-analysis, no statistical difference in adenoma detection rate was detected between EAC and CAC (47.0% vs 45.1%; P = 0.33). EAC significantly improved detection rate of diminutive adenomas/polyps compared with CAC (P = 0.01). Cecal intubation was achieved in 96.5% in EAC group and 97.9% in CAC group (P = 0.04). Besides, no statistical difference was found in cecal intubation time (P = 0.86), withdrawal time (P = 0.88), small adenomas/polyps (P = 0.60), or large adenomas/polyps (P = 0.95). CONCLUSION: EAC and CAC have their respective merits. EAC significantly improve the detection of diminutive adenomas/polyps. CAC was better in cecal intubation rate.


Assuntos
Adenoma/diagnóstico , Neoplasias do Colo/diagnóstico , Colonoscopia/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Adenoma/patologia , Neoplasias do Colo/patologia , Pólipos do Colo/diagnóstico , Pólipos do Colo/patologia , Feminino , Humanos , Masculino
7.
Clin Transl Gastroenterol ; 12(1): e00282, 2020 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-33395075

RESUMO

INTRODUCTION: Conventional gastrointestinal (GI) endoscopy reports written by physicians are time consuming and might have obvious heterogeneity or omissions, impairing the efficiency and multicenter consultation potential. We aimed to develop and validate an image recognition-based structured report generation system (ISRGS) through a multicenter database and to assess its diagnostic performance. METHODS: First, we developed and evaluated an ISRGS combining real-time video capture, site identification, lesion detection, subcharacteristics analysis, and structured report generation. White light and chromoendoscopy images from patients with GI lesions were eligible for study inclusion. A total of 46,987 images from 9 tertiary hospitals were used to train, validate, and multicenter test (6:2:2). Moreover, 5,699 images were prospectively enrolled from Qilu Hospital of Shandong University to further assess the system in a prospective test set. The primary outcome was the diagnosis performance of GI lesions in multicenter and prospective tests. RESULTS: The overall accuracy in identifying early esophageal cancer, early gastric cancer, early colorectal cancer, esophageal varices, reflux esophagitis, Barrett's esophagus, chronic atrophic gastritis, gastric ulcer, colorectal polyp, and ulcerative colitis was 0.8841 (95% confidence interval, 0.8775-0.8904) and 0.8965 (0.8883-0.9041) in multicenter and prospective tests, respectively. The accuracy of cecum and upper GI site identification were 0.9978 (0.9969-0.9984) and 0.8513 (0.8399-0.8620), respectively. The accuracy of staining discrimination was 0.9489 (0.9396-0.9568). The relative error of size measurement was 4.04% (range 0.75%-7.39%). DISCUSSION: ISRGS is a reliable computer-aided endoscopic report generation system that might assist endoscopists working at various hospital levels to generate standardized and accurate endoscopy reports (http://links.lww.com/CTG/A485).


Assuntos
Endoscopia Gastrointestinal/métodos , Gastroenteropatias/diagnóstico , Trato Gastrointestinal/diagnóstico por imagem , Troca de Informação em Saúde , Interpretação de Imagem Assistida por Computador/métodos , China , Bases de Dados como Assunto , Gastroenteropatias/patologia , Trato Gastrointestinal/patologia , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Gravação em Vídeo
8.
J Dig Dis ; 20(11): 578-588, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31429214

RESUMO

OBJECTIVE: This meta-analysis aimed to evaluate whether EndoCuff-assisted colonoscopy (EAC) could improve adenoma detection rate (ADR) compared with standard colonoscopy (SC). METHODS: PubMed, EMBASE, Scopus, Cochrane Library, and Google Scholar databases were searched for articles published up to March 2019. All pure randomized controlled trials comparing ADR between EAC and SC groups were included. Dichotomous data were pooled to obtain the odds ratio with a 95% confidence interval (CI), whereas continuous data were pooled using a mean difference with 95% CI. Review Manager Version 5.3 was used for data analysis. RESULTS: Thirteen randomized controlled trials consisting of 9038 patients (EAC: 4574; SC: 4464) were included. The EAC group showed significant superiority over the SC group in ADR (odds ratio 1.37, 95% CI 1.15-1.62). However, there were no differences between the EAC and SC groups in adverse events, cecal intubation rate, and cecal intubation time. CONCLUSIONS: EAC could significantly improve ADR without increasing adverse events, especially for operators with low ADRs. In addition, no significant difference was observed in cecal intubation time and cecal intubation rate between EAC and SC.


Assuntos
Adenoma/diagnóstico , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Colonoscopia/efeitos adversos , Humanos , Intubação Gastrointestinal , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA