RESUMO
BACKGROUND: Ablation of some myocardial substrates requires catheter-based radiofrequency delivery at the root of a great artery. We studied the safety and efficacy parameters associated with catheter-based radiofrequency delivery at the root of the aorta and pulmonary artery. METHODS: Thirty-six pigs underwent in-vivo catheter-based ablation under continuous contact-force and lesion index (power, contact-force, and time) monitoring during 60-s radiofrequency delivery with an open-irrigated tip catheter. Twenty-eight animals were allocated to groups receiving 40 W (n=9), 50 W (n=10), or 60 W (n=9) radiofrequency energy, and acute (n=22) and chronic (n=6) arterial wall damage was quantified by multiphoton microscopy in ex vivo samples. Adjacent myocardial lesions were quantified in parallel samples. The remaining 8 pigs were used to validate safety and efficacy parameters. RESULTS: Acute collagen and elastin alterations were significantly associated with radiofrequency power, although chronic assessment revealed vascular wall recovery in lesions without steam pop. The main parameters associated with steam pops were median peak temperature >42°C and impedance falls >23 ohms. Unlike other parameters, lesion index values of 9.1 units (interquartile range, 8.7-9.8) were associated with the presence of adjacent myocardial lesions in both univariate ( P=0.03) and multivariate analyses ( P=0.049; odds ratio, 1.99; 95% CI, 1.02-3.98). In the validation group, lesion index values using 40 W over a range of contact-forces correlated with the size of radiofrequency lesions (R2=0.57; P=0.03), with no angiographic or histopathologic signs of coronary artery damage. CONCLUSIONS: Lesion index values obtained during 40 W radiofrequency applications reliably monitor safe and effective lesion creation at the root of the great arteries.
Assuntos
Aorta/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Artéria Pulmonar/cirurgia , Irrigação Terapêutica/instrumentação , Animais , Aorta/metabolismo , Aorta/patologia , Ablação por Cateter/efeitos adversos , Colágeno/metabolismo , Elastina/metabolismo , Desenho de Equipamento , Masculino , Modelos Animais , Duração da Cirurgia , Pressão , Artéria Pulmonar/metabolismo , Artéria Pulmonar/patologia , Medição de Risco , Fatores de Risco , Sus scrofaRESUMO
Abstract Objective: Ventricular fibrillation (VF)-related sudden cardiac death (SCD) is a leading cause of mortality and morbidity. Current biological and imaging parameters show significant limitations on predicting cerebral performance at hospital admission. The AWAKE study (NCT03248557) is a multicentre observational study to validate a model based on spectral ECG analysis to early predict cerebral performance and survival in resuscitated comatose survivors. Methods: Data from VF ECG tracings of patients resuscitated from SCD will be collected using an electronic Case Report Form. Patients can be either comatose (Glasgow Coma Scale GCS --- ≤8) survivors undergoing temperature control after return of spontaneous circulation (RoSC), or those who regain consciousness (GCS = 15) after RoSC; all admitted to Intensive Cardiac Care Units in 4 major university hospitals. VF tracings prior to the first direct current shock will be digitized and analyzed to derive spectral data and feed a predictive model to estimate favorable neurological performance (FNP). The results of the model will be compared to the actual prognosis. Results: The primary clinical outcome is FNP during hospitalization. Patients will be categorized into 4 subsets of neurological prognosis according to the risk score obtained from the predictive model. The secondary clinical outcomes are survival to hospital discharge, and FNP and survival after 6 months of follow-up. The model-derived categorisation will be also compared with clinical variables to assess model sensitivity, specificity, and accuracy. Conclusions: A model based on spectral analysis of VF tracings is a promising tool to obtain early prognostic data after SCD.
Resumen Objetivo: La muerte súbita (MS) por fibrilación ventricular (FV) es una importante causa de morbilidad y mortalidad. Los métodos biológicos y de imagen actuales muestran limitaciones para predecir el pronóstico cerebral al ingreso hospitalario. AWAKE es un estudio observacional, multicéntrico, con el objetivo de validar un modelo basado en el análisis espectral del elec- trocardiograma (ECG), que predice precozmente el pronóstico cerebral y la supervivencia en pacientes resucitados y en estado de coma. Métodos: Se recogerán datos de los ECG con FV de pacientes reanimados de MS. Los pacientes pueden ser tanto supervivientes en estado de coma (Glasgow Coma Scale GCS ≤ 8) sometidos a control de temperatura tras la recuperación de circulación espontánea (RCE), como aquellos que recuperan la consciencia (GCS = 15) tras RCE; todos ellos ingresados en unidades de terapia intensiva cardiológica de 4 hospitales de referencia. Los registros de FV previos al primer choque se digitalizarán y analizarán para obtener datos espectrales que se incluirán en un modelo predictivo que estime el pronóstico neurológico favorable (PNF). El resultado del modelo se comparará con el pronóstico real. Resultados: El objetivo principal es el PNF durante la hospitalización. Los pacientes se categorizarán en 4 subgrupos de pronóstico neurológico según la estimación de riesgo obtenida en el modelo predictivo. Los objetivos secundarios son supervivencia al alta hospitalaria, y PNF y supervivencia a los 6 meses. El resultado de este modelo también se comparará con el pronóstico según variables clínicas. Conclusiones: Un modelo basado en el análisis espectral de registros de FV es una herramienta prometedora para obtener datos pronósticos precoces tras MS por FV.
Assuntos
Humanos , Algoritmos , Morte Súbita Cardíaca/epidemiologia , Eletrocardiografia/métodos , Prognóstico , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/fisiopatologia , Seguimentos , Modelos Estatísticos , Sensibilidade e Especificidade , Hospitalização , Unidades de Terapia IntensivaRESUMO
Pressure overload and heart failure electrophysiological remodeling (HF-ER) in pigs are associated with decreased conduction velocity (CV) and dispersion of repolarization, which lead to higher risk of ventricular arrhythmia. This work aimed to establish the correlation between QRS complex duration and underlying changes in CV during increased intraventricular pressure (IVP) and/or HF-ER ex-vivo, and to determine whether QRS duration could be sensitive to an acute increase in left ventricular (LV) afterload in-vivo. HF-ER was induced in 7 pigs by high-rate ventricular pacing. Seven weight-matched animals were used as controls. Isolated Langendorff-perfused hearts underwent programmed ventricular stimulation to study QRS complex duration and CV under low/high IVP, using volume-conducted ECG and epicardial optical mapping, respectively. Four additional pigs underwent open-chest surgery to increase LV afterload by partially clamping the ascending aorta, while measuring QRS complex duration during sinus rhythm (SR). In 13 hearts included for analysis, both HF-ER and increased IVP showed significantly slower epicardial CV (-40% and -15%, p < 0.001 and p = 0.004, respectively), which correlated with similar widening of the QRS complex (+41% and +17%, p = 0.005 and p < 0.001, respectively). HF-ER hearts shower larger prolongation of the QRS complex than controls upon increasing the IVP (+21% vs. +12%, respectively. HF-ER*IVP interaction: p = 0.004). QRS complex widened after increasing LV afterload in-vivo (n=3), with correlation between QRS duration and aortic diastolic pressures (R = 0.58, p < 0.001). In conclusion, high IVP and/or HF-ER significantly decrease CV, which correlates with QRS widening on the ECG during ventricular pacing. Increased myocardial wall stress also widens the QRS complex during SR in-vivo.