Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38992191

RESUMO

PURPOSE: In patients with inner ear schwannomas (IES), reports on hearing rehabilitation with cochlear implants (CI) have increased over the past decade, most of which are case reports or small case series. The aim of this study is to systematically review the reported hearing results with CI in patients with IES considering the different audiologic outcome measures used in different countries. METHODS: According to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline, a search of published literature was conducted. We included patients with IES (primary or with secondary extension from the internal auditory canal (IAC) to the inner ear, sporadic or NF2 related) undergoing cochlear implantation with or without tumour removal. The audiological results were divided into the categories "monosyllables", "disyllables", "multisyllabic words or numbers", and "sentences". RESULTS: Predefined audiological outcome measures were available from 110 patients and 111 ears in 27 reports. The mean recognition scores for monosyllabic words with CI were 55% (SD: 24), for bisyllabic words 61% (SD: 36), for multisyllabic words and numbers 87% (SD: 25), and 71% (SD: 30) for sentences. Results from for multisyllabic words and numbers in general showed a tendency towards a ceiling effect. Possible risk factors for performance below average were higher complexity tumours (inner ear plus IAC/CPA), NF2, CI without tumour removal ("CI through tumour"), and sequential cochlear implantation after tumour removal (staged surgery). CONCLUSION: Hearing loss in patients with inner ear schwannomas can be successfully rehabilitated with CI with above average speech performance in most cases. Cochlear implantation thus represents a valuable option for hearing rehabilitation also in patients with IES while at the same time maintaining the possibility of MRI follow-up. Further studies should investigate possible risk factors for poor performance. Audiological tests and outcome parameters should be reported in detail and ideally be harmonized to allow better comparison between languages.

2.
Otol Neurotol ; 45(5): 580-586, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38437842

RESUMO

OBJECTIVE: To describe the genetic characteristics and the management of two very rare cases of unilateral multifocal inner ear and internal auditory canal or cerebellopontine angle cochleovestibular schwannomas not being associated to full neurofibromatosis type 2-related schwannomatosis. PATIENTS: In a 29-year-old man and a 55-year-old woman with single-sided deafness multifocal unilateral cochleovestibular schwannomas were surgically resected, and hearing was rehabilitated with a cochlear implant (CI). Unaffected tissue was analyzed using next generation sequencing of the NF2 gene. Tumor tissue was analyzed using a 340-parallel sequencing gene panel. MAIN OUTCOME MEASURES: Mutations in the NF2 gene, word recognition score for monosyllables at 65 dB SPL (WRS 65 ) with CI. RESULTS: No disease-causing mutation was detected in the examined sequences in blood leucokytes. All tumor samples revealed, among others, somatic pathogenic NF2 mutations. While the anatomically separate tumors in case 1 were likely molecular identical, the tumors in case 2 showed different genetic patterns. WRS 65 was 55% at 6 years of follow-up and 60% at 4.5 years of follow-up, respectively. CONCLUSIONS: The occurrence of multifocal unilateral cochleovestibular schwannomas without pathogenic variants in NF2 in non-affected blood leucocytes can be associated with mosaic NF2 -related schwannomatosis (case 1), or with likely sporadic mutations (case 2) and may be overlooked due to their extreme rarity. Although challenging, successful hearing rehabilitation could be achieved through surgical resection of the tumors and cochlear implantation.


Assuntos
Ângulo Cerebelopontino , Implante Coclear , Neuroma Acústico , Humanos , Feminino , Pessoa de Meia-Idade , Implante Coclear/métodos , Masculino , Adulto , Neuroma Acústico/cirurgia , Neuroma Acústico/genética , Neuroma Acústico/patologia , Ângulo Cerebelopontino/cirurgia , Ângulo Cerebelopontino/patologia , Orelha Interna/cirurgia , Orelha Interna/patologia , Neurilemoma/cirurgia , Neurilemoma/genética , Neurilemoma/patologia , Mutação , Neoplasias da Orelha/cirurgia , Neoplasias da Orelha/genética , Neoplasias da Orelha/patologia , Neurofibromina 2/genética
3.
PLoS One ; 18(9): e0287216, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37682960

RESUMO

OBJECTIVE: Cochlear implants (CIs) can restore hearing not only in patients with profound hearing loss and deafness, but also in patients following tumour removal of intra-cochlear schwannomas. In such cases, design and placement differ from conventional electrode insertion, in which the cochlea remains filled with fluid. Despite these technical and surgical differences, previous studies have tended to show positive results in speech perception in tumour patients. The purpose of this study is to retrospectively evaluate the ability to predict speech recognition outcomes using individual electric field spreads and to investigate worldwide unique tumour cases. STUDY DESIGN: In a retrospective analysis in a university tertiary center electric field spreads were compared between two groups of electrode designs implanted between 2009 and 2020 i.e., between lateral wall electrodes and custom-made perimodiolar electrode carriers from the same company. The voltage gradients were analysed and grouped with speech recognition results. RESULTS: Differences in electrical field spreads were found between lateral wall electrodes and the custom-made perimodiolar electrodes, whereas a significant influence of electric fields on scores in speech recognition cannot be demonstrated. CONCLUSION: Prediction of speech recognition outcome based on electric field propagation results seems not feasible. Significant differences in field spread between electrode arrays can be clearly demonstrated. This observation and its relevance to hearing treatment and speech recognition should therefore be further investigated in upcoming studies.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Estudos Retrospectivos , Cóclea/cirurgia , Eletrodos Implantados
4.
Otol Neurotol ; 44(5): e305-e310, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37167447

RESUMO

OBJECTIVE: To assess the rate of dilatory (chronic obstructive) eustachian tube dysfunction (ETD) in adult patients scheduled for surgery for chronic inflammatory middle ear disease. PATIENTS: We included adult patients with chronic inflammatory middle ear disease (chronic suppurative otitis media, adhesive otitis media [middle ear atelectasis], cholesteatoma). We excluded patients with pathologies that do not stem from ETD (e.g., noninflammatory chronic middle ear disease [e.g., otosclerosis], tumors, solely external auditory canal conditions), patients scheduled for implantable electronic hearing devices independent of disease, patients with otitis media with effusion and scheduled paracentesis or ventilation tubes only, patients with previous radiotherapy or previous balloon eustachian tuboplasty, and children and patients unable to complete questionnaires. INTERVENTIONS: We evaluated ETD with Valsalva maneuver and in case of negative or unclear Valsalva with the eustachian tube score (ETS). A negative Valsalva maneuver and an ETS score of 5 or lower were used to define dilatory (chronic obstructive) ETD. MAIN OUTCOME MEASURES: Rate of ETD in the included patients. RESULTS: From a total of 482 consecutive patients, 350 patients had positive Valsalva maneuver or ETS score higher than 5. From the 193 patients with negative or unclear Valsalva maneuver, 77 patients had an ETS score of 5 or lower, and 55 rejected further diagnostics with ETS. CONCLUSIONS: Based on a large cohort of adult patients with chronic inflammatory middle ear disease scheduled for middle ear surgery, the majority (82%) seems to have no dilatory (chronic obstructive) ETD that can be detected with current routine clinical methods and tubomanometry. Common pathophysiological explanations should be questioned critically, especially in the context of communication with patients.


Assuntos
Otopatias , Tuba Auditiva , Otite Média Supurativa , Otite Média , Criança , Adulto , Humanos , Tuba Auditiva/patologia , Orelha Média , Otopatias/patologia , Otite Média/cirurgia , Timpanoplastia , Otite Média Supurativa/cirurgia , Doença Crônica
5.
HNO ; 71(Suppl 1): 1-9, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36083471

RESUMO

BACKGROUND: The simultaneous implantation of the Bonebridge (MED-EL, Innsbruck, Austria), a semi-implantable active transcutaneous bone conduction hearing device and anchors for auricular prostheses can be challenging as both implants contain magnets and compete for the narrow space in the designated implantation area. MATERIAL AND METHODS: A preoperative planning tool (virtual surgery) was used with individual 3D computer models of the skull and implants for finding optimal implant positions for both the floating mass transducer (FMT) and the anchors for the auricular prosthesis. The interaction between the magnetic prosthesis anchors and the FMT was measured by means of static magnetic forces. A retrospective data analysis was conducted to evaluate the surgical and audiological outcome. RESULTS: Between 2014 and 2021, a 3D planning of a simultaneous implantation of the Bonebridge with auricular prosthesis anchors was conducted on 6 ears of 5 patients (3 males, 2 females; age range 17-56 years). The individual preoperative planning was considered very useful for the optimal placement of bone anchors in combination with the Bonebridge. Audiological data showed a clear benefit for hearing 3 months and > 11 months after implantation. No adverse interactions between the magnetic prosthesis anchors and the FMT were observed. In two patients, revision surgery was carried out due to skin inflammation or wound healing problems. No long-term complications were observed 3-5 years after surgery. CONCLUSION: Preoperative 3D planning represents a clear benefit for the simultaneous audiological and esthetic rehabilitation using the Bonebridge and anchors for auricular prostheses.


Assuntos
Auxiliares de Audição , Perda Auditiva Condutiva , Masculino , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Perda Auditiva Condutiva/etiologia , Condução Óssea , Estudos Retrospectivos , Próteses e Implantes/efeitos adversos , Computadores , Resultado do Tratamento
6.
HNO ; 71(6): 365-374, 2023 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-35920881

RESUMO

BACKGROUND: The simultaneous implantation of the Bonebridge (MED-EL, Innsbruck, Austria), a semi-implantable active transcutaneous bone conduction hearing device and anchors for auricular prostheses can be challenging as both implants contain magnets and compete for the narrow space in the designated implantation area. MATERIAL AND METHODS: A preoperative planning tool (virtual surgery) was used with individual 3D computer models of the skull and implants for finding optimal implant positions for both the floating mass transducer (FMT) and the anchors for the auricular prosthesis. The interaction between the magnetic prosthesis anchors and the FMT was measured by means of static magnetic forces. A retrospective data analysis was conducted to evaluate the surgical and audiological outcome. RESULTS: Between 2014 and 2021 a 3D planning of a simultaneous implantation of the Bonebridge with auricular prosthesis anchors was conducted on 6 ears of 5 patients (3 males, 2 females; age range 17-56 years). The individual preoperative planning was considered very useful for the optimal placement of bone anchors in combination with the Bonebridge. Audiological data showed a clear benefit for hearing 3 months and > 11 months after implantation. No adverse interactions between the magnetic prosthesis anchors and the FMT were observed. In two patients, revision surgery was carried out due to skin inflammation or wound healing problems. No long-term complications were observed 3-5 years after surgery. CONCLUSION: Preoperative 3D planning represents a clear benefit for the simultaneous audiological and esthetic rehabilitation using the Bonebridge and anchors for auricular prostheses.


Assuntos
Auxiliares de Audição , Próteses e Implantes , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Condução Óssea , Computadores , Estudos Retrospectivos , Resultado do Tratamento
9.
Laryngorhinootologie ; 101(4): 335-362, 2022 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-35320854

RESUMO

Diagnostics of hearing loss comprises subjective and objective methods and is successfully applied since many decades. This article introduces into the methods of impedance audiometry, otoacoustic emissions, auditory evoked potentials and electrically evoked potentials and describes the respective methodologies. Using an exemplary case, in this article we guide through all stages of objective audiological diagnostics and introduce the scientific and technical background, the application and evaluation of the findings of the objective test procedures. An application pathway for objective audiometric diagnostic tools is also described, including newborn hearing screening, differential diagnostics of hearing loss, auditory neuropathy, sudden sensorineural hearing loss, vestibular schwannoma and pediatrics patients. Finally, the application to patients with active middle-ear implants and cochlear implants is described.


Assuntos
Surdez , Perda Auditiva Central , Perda Auditiva Neurossensorial , Perda Auditiva , Audiometria de Tons Puros , Criança , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Perda Auditiva Neurossensorial/diagnóstico , Humanos , Recém-Nascido , Emissões Otoacústicas Espontâneas/fisiologia
10.
Acta Otolaryngol ; 142(2): 140-153, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35209792

RESUMO

BACKGROUND: Middle ear implants (MEI) are for the medical rehabilitation of the hearing function in case of sound conduction hearing losses as well as cochlear hearing losses and their combinations. OBJECTIVES: An objective tool to reach the best fitting of the external worn sound processors is essential for patients who do not want or cannot participate in the fitting process. METHODS: In addition to Laser-Doppler-Vibrometry (LDV) measurement, the sound pressure was measured distant to the eardrum to attain additional information for comparison. Three groups of patients with different middle ear characteristics were examined. RESULTS: Because of the large spreading of measuring results even within a patient group with similar eardrum and middle ear conditions it is difficult to develop characteristic diagrams which represent the mean values of eardrum displacements with different sound processor adjustments being the base for normative data courses. CONCLUSIONS AND SIGNIFICANCE: The LDV measurements can be used as a tool for fitting sound processors by finding individual maximum eardrum velocities in the frequency range 125 Hz to 8 kHz. In comparison to acoustical measurements the optical measurements have advantages concerning lower variations of measurement values, higher spectral resolution, and robustness against disturbing acoustic noise, especially at low frequencies.


Assuntos
Meato Acústico Externo , Prótese Ossicular , Meato Acústico Externo/cirurgia , Orelha Média , Humanos , Som , Membrana Timpânica , Vibração
11.
Eur Arch Otorhinolaryngol ; 279(10): 4667-4675, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34874465

RESUMO

PURPOSE: The Vibrant Soundbridge (VSB) was introduced in 1996, and the fourth generation of the audio processor recently released. This clinical study evaluates the audiological performance and subjective satisfaction of the new SAMBA 2 audio processor compared to its predecessor, SAMBA. METHOD: Fifteen VSB users tested both audio processors for approximately 3 weeks. Air conduction and bone conduction thresholds and unaided and aided sound field thresholds were measured with both devices. Speech performance in quiet (Freiburg monosyllables) and noise (OLSA) was evaluated as well as subjective listening effort (ACALES) and questionnaire outcomes (SSQ12 and APSQ). In addition, data from 16 subjects with normal hearing were gathered on sound field tests and ACALES. RESULTS: Both audio processors showed substantial improvement compared to the unaided condition. The SAMBA and SAMBA 2 had comparable performance in sound filed thresholds, while the SAMBA 2 was significantly better in speech in quiet, speech in noise, reduced listening effort, and improved subjective satisfaction compared with the SAMBA. CONCLUSION: The SAMBA 2 audio processor, compared to its predecessor SAMBA, offers improved performance throughout the parameters investigated in this study. Patients with a VSB implant would benefit from an upgrade to SAMBA 2.


Assuntos
Auxiliares de Audição , Prótese Ossicular , Percepção da Fala , Condução Óssea , Audição , Humanos
12.
Eur Arch Otorhinolaryngol ; 279(1): 101-113, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33674927

RESUMO

PURPOSE: Aim of the study was to evaluate the surgical, clinical and audiological outcome of 32 implantations of the Bonebridge, a semi-implantable transcutaneous active bone conduction implant. METHODS: In a retrospective cohort study, we analyzed data for 32 implantations in 31 patients (one bilateral case; seven age < 16 years) with conductive or mixed hearing loss, malformations, after multiple ear surgery, or with single-sided deafness as contralateral routing of signal (CROS). RESULTS: Four implantations were done as CROS. Five cases were simultaneously planned with ear prosthesis anchors, and 23 implantations (72%) were planned through three-dimensional (3D) "virtual surgery." In all 3D-planned cases, the implant could be placed as expected. For implant-related complications, rates were 12.5% for minor and 3.1% for major complications. Implantation significantly improved mean sound field thresholds from a preoperative 60 dB HL (SD 12) to 33 dB HL (SD 6) at 3 postoperative months and 34 dB HL (SD 6) at > 11 postoperative months (p < 0.0001). Word recognition score in quiet at 65 dB SPL improved from 11% (SD 20) preoperatively to 74% (SD 19) at 3 months and 83% (SD 15) at > 11 months (p < 0.0001). The speech reception threshold in noise improved from - 1.01 dB unaided to - 2.69 dB best-aided (p = 0.0018). CONCLUSION: We found a clinically relevant audiological benefit with Bonebridge. To overcome anatomical challenges, we recommend preoperative 3D planning in small and hypoplastic mastoids, children, ear malformation, and simultaneous implantation of ear prosthesis anchors and after multiple ear surgery.


Assuntos
Auxiliares de Audição , Percepção da Fala , Adolescente , Adulto , Condução Óssea , Criança , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/etiologia , Perda Auditiva Condutiva/cirurgia , Humanos , Próteses e Implantes , Estudos Retrospectivos , Resultado do Tratamento
13.
HNO ; 70(5): 396-400, 2022 May.
Artigo em Alemão | MEDLINE | ID: mdl-34468776

RESUMO

We report on a case in which macroscopic and microscopic changes of the vestibulocochlear nerve could be observed after radiosurgery of an intrameatal vestibular schwannoma. This case shows for the first time a morphological correlate for undesirable effects after radiosurgical treatment of a vestibular schwannoma and indicates that despite a certain distance to the actual tumor, degenerative changes in neural structures can be expected.


Assuntos
Neuroma Acústico , Radiocirurgia , Humanos , Neuroma Acústico/diagnóstico , Neuroma Acústico/cirurgia , Radiocirurgia/efeitos adversos , Resultado do Tratamento , Nervo Vestibulococlear/patologia , Nervo Vestibulococlear/cirurgia
14.
Trials ; 22(1): 475, 2021 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-34294114

RESUMO

BACKGROUND: A previously performed phase III trial on 112 subjects investigating prophylactic nimodipine treatment in vestibular schwannoma (VS) surgery showed no clear beneficial effects on preservation of facial and cochlear nerve functions, though it should be considered that protection of facial nerve function was the primary outcome. However, the risk for postoperative hearing loss was halved in the nimodipine group compared to the control group (OR 0.49; 95% CI 0.18-1.30; p = 0.15). Accordingly, this phase III extension trial investigates the efficacy and safety of prophylactic nimodipine for hearing preservation in VS surgery. METHODS: This is a randomized, multi-center, two-armed, open-label phase III trial with blinded expert review and two-stage with interim analysis. Three hundred thirty-six adults with the indication for microsurgical removal of VS (Koos I-IV) and serviceable preoperative hearing (Gardner-Robertson scale (GR) 1-3) are assigned to either the therapy (intravenous nimodipine 1-2 mg/h from the day before surgery until the fifth postoperative day and standard of care) or the control group (surgery only and standard of care). The primary endpoint of the trial is postoperative cochlear nerve function measured before discharge according to GR 1-3 versus GR 4-5 (binary). Hearing function will be determined by pre- and postoperative audiometry with speech discrimination, which will be evaluated by a blinded expert reviewer. Furthermore, patient-reported outcomes using standardized questionnaires will be analyzed. DISCUSSION: Prophylactic parenteral nimodipine treatment may have a positive effect on hearing preservation in VS surgery and would improve patient's quality of life. Further secondary analyses are planned. Except for dose-depending hypotension, nimodipine is known as a safe drug. In the future, prophylactic nimodipine treatment may be recommended as a routine medication in VS surgery. VS can be considered as an ideal model for clinical evaluation of neuroprotection, since hearing outcome can be classified by well-recognized criteria. The beneficial effect of nimodipine may be transferable to other surgical procedures with nerves at risk and may have impact on basic research. TRIAL REGISTRATION: EudraCT 2019-002317-19, DRKS00019107 . 8th May 2020.


Assuntos
Neuroma Acústico , Nimodipina , Adulto , Ensaios Clínicos Fase III como Assunto , Audição , Humanos , Estudos Multicêntricos como Assunto , Neuroma Acústico/diagnóstico , Neuroma Acústico/cirurgia , Nimodipina/efeitos adversos , Complicações Pós-Operatórias , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos , Resultado do Tratamento
15.
Sci Rep ; 11(1): 8608, 2021 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-33883565

RESUMO

In vestibular schwannoma (VS) patients hearing outcome and surgery related risks can vary and depend on the nerve of origin. Preoperative origin differentiation between inferior or superior vestibular nerve may influence the decision on treatment, and the selection of optimal treatment and counselling modalities. A novel scoring system based on functional tests was designed to predict the nerve of origin for VS and was applied to a large number of consecutive patients. A prospective, double blind, cohort study including 93 patients with suspected unilateral VS was conducted at a tertiary referral centre. Preoperatively before tumor resection a functional test battery [video head-impulse test (vHIT) of all semicircular canals (SCC)], air-conducted cervical/ocular vestibular evoked myogenic potential tests (cVEMP, oVEMP), pure-tone audiometry, and speech discrimination was applied. Sensitivity and specificity of prediction of intraoperative finding by a preoperative score based on vHIT gain, cVEMP and oVEMP amplitudes and asymmetry ratios was calculated. For the prediction of inferior vestibular nerve origin, sensitivity was 73% and specificity was 80%. For the prediction of superior vestibular nerve origin, sensitivity was 60% and specificity was 90%. Based on the trade-off between sensitivity and specificity, optimized cut-off values of - 0.32 for cVEMP and - 0.11 for oVEMP asymmetry ratios and vHIT gain thresholds of 0.77 (anterior SCC), 0.84 (lateral SCC) and 0.80 (posterior SCC) were identified by receiver operator characteristic curves. The scoring system based on preoperative functional tests improves prediction of nerve of origin and can be applied in clinical routine.


Assuntos
Neurilemoma/patologia , Nervo Vestibular/patologia , Adolescente , Adulto , Idoso , Audiometria de Tons Puros/métodos , Método Duplo-Cego , Feminino , Teste do Impulso da Cabeça/métodos , Audição/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Neuroma Acústico/patologia , Estudos Prospectivos , Canais Semicirculares/patologia , Potenciais Evocados Miogênicos Vestibulares/fisiologia , Adulto Jovem
16.
Commun Med (Lond) ; 1: 37, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35602216

RESUMO

Background: The receptors for hearing and balance are housed together in the labyrinth of the inner ear and share the same fluids. Surgical damage to either receptor system was widely believed to cause certain permanent loss of the receptor function of the other. That principle, however, has been called into question because there have been anecdotal reports in individual patients of at least partial preservation of cochlear function after major surgical damage to the vestibular division and vice versa. Methods: We performed specific objective vestibular function tests before and after surgical trauma (partial or subtotal cochlear removal) for treatment of intracochlear tumors in 27 consecutive patients in a tertiary referral center. Vestibular function was assessed by calorics (low-frequency response of the lateral semicircular canal), vestibulo-ocular reflex by video head impulse test (vHIT) of the three semicircular canals, cervical and ocular vestibular evoked myogenic potentials (cVEMP, saccule and oVEMP, utricle). Preoperative and postoperative distributions were compared with paired t-tests. Results: Here we show that there was no significant difference between pre- and post-operative measures for all tests of the five vestibular organs, and that after major surgical cochlear trauma, the vestibular receptors continue to function independently. Conclusions: These surprising observations have important implications for our understanding of the function and the surgery of the peripheral auditory and vestibular system in general and open up new possibilities for the development, construction and evaluation of neural interfaces for electrical or optical stimulation of the peripheral auditory and vestibular nervous system.

17.
Eur Arch Otorhinolaryngol ; 278(1): 67-75, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32451668

RESUMO

PURPOSE: To evaluate the safety and performance of three novel vibroplasty couplers that allow attachment of the floating mass transducer of a transcutaneous active middle ear implant (AMEI) to the round window (RW) membrane, the long process (LP), or the incus body and the short process (SP) of the incus. METHODS: Retrospective multicenter cohort study of 25 AMEI users with sensorineural or mixed hearing loss that were among the first implanted with an AMEI vibrating ossicular prosthesis in combination with the third generation of vibroplasty couplers between 2014 and 2016. Main Outcome Measures were bone-conduction pure-tone and vibroplasty thresholds, postoperative aided sound field thresholds and postoperative aided word recognition score (WRS). RESULTS: Bone conduction threshold changes of more than 10 dB in 4PTABC were observed in two subjects. A mean improvement of 57.8% in speech recognition was observed with a mean WRS at 65 dB SPL improving from 14.8% (SD 21.9%) preoperatively to a mean aided score of 72.6% (SD 18.6%). Sound field thresholds improved from an average 4PTASF of 64.1 dB HL (SD 9.8 dB HL) to 37.0 dB HL (SD 8.9 dB HL), resulting in a mean functional gain of 27.1 dB. There was no significant difference in WRS or functional gain between the coupler types. CONCLUSION: Initial experience shows that all three third generation vibroplasty couplers represent safe and efficient attachment options for the FMT allowing the surgeon to choose the coupling type based on the present pathology.


Assuntos
Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Prótese Ossicular , Substituição Ossicular/métodos , Adolescente , Adulto , Idoso , Criança , Estudos de Coortes , Orelha Média , Características da Família , Feminino , Auxiliares de Audição , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Estudos Retrospectivos , Janela da Cóclea/fisiologia , Janela da Cóclea/cirurgia , Resultado do Tratamento , Adulto Jovem
18.
Eur Arch Otorhinolaryngol ; 278(2): 353-362, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32504199

RESUMO

PURPOSE: We here report about the first surgical experience and audiological outcome using a new, perimodiolar malleable cochlear implant electrode array for hearing rehabilitation after subtotal cochleoectomy for intralabyrinthine schwannoma (ILS). METHOD: Based on a cochlear implant with MRI compatibility of the magnet in the receiver coil up to 3 T, a cochlear implant electrode array was developed that is malleable and can be placed perimodiolar after tumor removal from the cochlea via subtotal cochleoectomy. Malleability was reached by incorporating a nitinol wire into the silicone of the electrode array lateral to the electrode contacts. The custom-made device was implanted in four patients with intracochlear, intravestibulocochlear or transmodiolar schwannomas. Outcome was assessed by evaluating the feasibility of the surgical procedure and by measuring sound field thresholds and word recognition scores. RESULTS: After complete or partial tumor removal via subtotal cochleoectomy with or without labyrinthectomy, the new, perimodiolar malleable electrode array could successfully be implanted in all four patients. Six months after surgery, the averaged sound field thresholds to pulsed narrowband noise in the four patients were 36, 28, 41, and 35 dB HL, and the word recognitions scores for monosyllables at 65 dB SPL were 65, 80, 70, and 25% (one patient non-German speaking). CONCLUSION: The surgical evaluation demonstrated the feasibility of cochlear implantation with the new, perimodiolar malleable electrode array after subtotal cochleoectomy. The audiological results were comparable to those achieved with another commercially available type of perimodiolar electrode array from a different manufacturer applied in patients with ILS.


Assuntos
Implante Coclear , Implantes Cocleares , Neuroma Acústico , Cóclea/cirurgia , Eletrodos Implantados , Audição , Humanos , Neuroma Acústico/cirurgia
19.
HNO ; 69(7): 545-555, 2021 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-32885307

RESUMO

BACKGROUND: Surgical training is increasingly supported by the use of simulators. For temporal bone surgery, shown here by means of mastoidectomy, there are other training models besides cadaver specimens, such as artificial temporal bones or computer-based simulators. OBJECTIVES: A structured training concept was created which integrates different training methods of mastoidectomy with regard to effectiveness and current learning theory in education. METHOD: A selective literature research was conducted to compare learning-theoretical findings and the availability and effectiveness of currently existing training models. RESULTS: To acquire surgical skills, a stepwise approach is suggested. Depending on the progress with computer-based simulation, plastic or native temporal bones should be used. To achieve a plateau of the learning curve, approximately 25 semi-autonomous preparations are recommended. Different 'Objective Structured Assessments of Technical Skills' (OSATS) are implemented to assess the learning progress at different levels. DISCUSSION: Simulation-based training is recommended until an adequate learning curve plateau is achieved. This is reasonable for patient safety, based on limited accessibility of human cadaveric temporal bones but also by findings of the learning theory. CONCLUSION: The curriculum integrates different training models of mastoidectomy and OSATS into an overall concept. The training plan has to be continuously adapted to new findings and technical developments.


Assuntos
Internato e Residência , Treinamento por Simulação , Competência Clínica , Simulação por Computador , Humanos , Curva de Aprendizado , Osso Temporal
20.
Eur Arch Otorhinolaryngol ; 278(7): 2277-2288, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32880736

RESUMO

PURPOSE: Evaluating the effectiveness of intraoperative auditory brainstem responses (ABRs) to stimulation by the Vibrant Soundbridge (VSB) active middle ear implant for quantifying the implant's floating mass transducer (FMT) coupling quality. METHODS: In a diagnostic multicentric study, patients (> 18 years) who received a VSB with different coupling modalities were included. Pre- and postoperative bone conduction thresholds, intraoperative VSB-evoked ABR thresholds (VSB-ABR) using a modified audio processor programmed to preoperative bone conduction thresholds, postoperative vibrogram thresholds, and postoperative VSB-ABR thresholds were measured. Coupling quality was calculated from the difference between the pure tone average at 1000, 2000, and 4000 Hz (3PTA) vibrogram and postoperative 3PTA bone conduction thresholds. RESULTS: Twenty-three patients (13 males, 10 females, mean age 56.6 (± 12.5) years) were included in the study. Intraoperative VSB-ABR response thresholds could be obtained in all except one patient where the threshold was > 30 dB nHL. Postoperatively, an insufficient coupling of 36.7 dB was confirmed in this patient. In a Bland-Altman analysis of the intraoperative VSB-ABRs and coupling quality, the limits of agreement exceeded ± 10 dB, i.e., the maximum allowed difference considered as not clinically important but the variation was within the general precision of auditory brainstem responses to predict behavioral thresholds. Five outliers were identified. In two patients, the postoperative VSB-ABR thresholds were in agreement with the coupling quality, indicating a change of coupling before the postoperative testing. CONCLUSION: The response thresholds recorded in this set-up have the potential to predict the VSB coupling quality and optimize postoperative audiological results.


Assuntos
Perda Auditiva Condutiva-Neurossensorial Mista , Prótese Ossicular , Limiar Auditivo , Condução Óssea , Potenciais Evocados Auditivos do Tronco Encefálico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Transdutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA