Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Spectrochim Acta A Mol Biomol Spectrosc ; 279: 121330, 2022 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-35605418

RESUMO

L-cystine (L-cys) functionalized plasmonic silver nanomaterial (Ag NPs) was fabricated toward the selective and sensitive detection of paracetamol and cadmium. The prepared L-cys-Ag nanoparticles (NPs) were characterized by transmission electron microscopy (TEM), scanning electron microscopy (SEM), X-ray diffraction spectroscopy (XRD) and fourier transform infrared spectroscopy (FTIR) analyses. SEM imaging show that Ag NPs was decorated on the surface of L-cysteine 3D cubic nanosheet. L-cys-Ag NPs showed selective and sensitive detection towards paracetamol and cadmium. The interference study confirms that the presence of other metal ions didn't inhibit the detection of cadmium by L-cys-Ag NPs. The limit of detection of paracetamol and cadmium by L-cys-Ag NPs was calculated to be 1.2 and 2.82 nM respectively. In addition, the real sample detection of paracetamol on blood serum and urine, and cadmium on STP were performed and the recovery percentage was above 97%. Further, the real sample analysis was performed in tap and drinking water and the recovery percentage was more than 98%. The analytic logic gate on the multicolour detection of cadmium and paracetamol was performed for the semi-quantitative monitoring of paracetamol and cadmium by L-cys-Ag NPs. The developed L-cys-Ag NPs were found to be an effective tool for the monitoring of cadmium in environmental water bodies and paracetamol in blood and urine.


Assuntos
Nanopartículas Metálicas , Prata , Acetaminofen , Cádmio , Cistina , Nanopartículas Metálicas/química , Prata/química , Espectroscopia de Infravermelho com Transformada de Fourier
2.
Int J Biol Macromol ; 193(Pt B): 2054-2061, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34774598

RESUMO

L-Cysteine (L-cys) plays very crucial role in biological systems. The study reports the colorimetric detection of L-cys at nanomolar level using chitosan capped Ag decorated NiS nanocomposite (chit-Ag/NiS NCs).The chemical reduction and co-precipitation methods were adopted to prepare chit-Ag/NiS NCs. The fabricated NCs was characterized by X-ray diffraction (XRD), fourier-transform infrared spectroscopy (FT-IR), FT-Raman, scanning electron microscopy (SEM), thermogravimetric analysis (TGA), high-resolution transmission electron microscopy (HR-TEM), energy-dispersive X-ray spectroscopy (EDS) and X-ray photoelectron spectroscopy (XPS). The chit-Ag/NiS NCs particularly detect L-cys even in other amino acids presence. The chit-Ag/NiS NCs showed the surface charge of -26 ± 39.9 mV. The detection of L-cys was indicated by disappearance of yellowish-brown color of Chit-Ag/NiS NCs to colorless. A good linear correlation was found between absorbance vs logarithmic concentration of L-cys (1 µM to 1 nM) with R2 value of 0.99. The chit-Ag/NiS NCs impregnated cotton swabs was prepared for real time detection of L-cys and the prepared probe was found to be highly selective and specific. The effect of pH, temperature and salinity influencing the L-cys detection was studied. Also, the antimicrobial activity of Chit-Ag/NiS NCs was investigated against gram negative (E. coli) and gram positive (B. subtilis) bacteria.


Assuntos
Antibacterianos/química , Antibacterianos/farmacologia , Quitosana/química , Cisteína/química , Nanocompostos/química , Prata/química , Sulfonamidas/química , Bactérias/efeitos dos fármacos , Colorimetria/métodos , Nanopartículas Metálicas/química , Testes de Sensibilidade Microbiana/métodos , Microscopia Eletrônica de Varredura/métodos , Microscopia Eletrônica de Transmissão/métodos , Espectroscopia Fotoeletrônica/métodos , Espectrometria por Raios X/métodos , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Difração de Raios X/métodos
3.
Spectrochim Acta A Mol Biomol Spectrosc ; 243: 118766, 2020 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-32799187

RESUMO

Trivalent chromium (Cr(III)) is considered to exhibit hormesis (bi-phasic dose-response) property, where low dose be beneficial and high dose shows toxic effect. The present work describe the development of a bimetallic Ag/Co-polyvinylpyrrolidone nanocomposite (Ag/Co-PVP NPs) probe to detect and quantify Cr(III) ions from aqueous samples. The hydrodynamic size and zeta potential of the particle was determined to be 29 ± 1.3 nm and -37.19 ± 2.4 mV respectively. The interaction of Cr(III) with Ag/Co-PVP probe showed drastic change in colour of NPs from dark brown to pale yellow, with corresponding blue shift, tapering width and increased peak intensity. The probe showed high specificity towards Cr(III) among the tested metal ions. A linearity was observed between various dilutions of Cr(III) ions (10 to 50 nM) and the absorbance of Ag/Co-PVP NPs at 428 nm with R2 value of 0.998. The minimum detectable limit of Cr(III) was calculated to be 0.6 nM. The influence of salinity, temperature and pH on detection was studied. The probe was found to detect Cr(III) at acidic pH effectively. Competitive metal ions did not interfere the detection of Cr(III). The water sample collected from Noyyal river was taken to estimate Cr(III) by using the prepared probe to ensure practical applicability. The sample contains 9.3 nM of Cr(III) that was cross verified with AAS analysis. Hence, it is understood that the reported probe can be used to detect Cr(III) selectively with high accuracy from aqueous samples. In addition, the particles also exhibited excellent photocatalytic activity under visible light. Ag/Co-PVP nanocomposites exhibited excellent antibacterial activity against both gram +ve (B. subtilis) and gram -ve (E. coli) bacteria.


Assuntos
Nanopartículas Metálicas , Nanocompostos , Antibacterianos/farmacologia , Escherichia coli , Povidona , Prata
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA