Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Cancers (Basel) ; 16(8)2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38672560

RESUMO

The diagnosis, treatment, and management of gynecologic malignancies benefit from both positron emission tomography/computed tomography (PET/CT) and MRI. PET/CT provides important information on the local extent of disease as well as diffuse metastatic involvement. MRI offers soft tissue delineation and loco-regional disease involvement. The combination of these two technologies is key in diagnosis, treatment planning, and evaluating treatment response in gynecological malignancies. This review aims to assess the performance of PET/MRI in gynecologic cancer patients and outlines the technical challenges and clinical advantages of PET/MR systems when specifically applied to gynecologic malignancies.

2.
medRxiv ; 2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38343810

RESUMO

Background: Restriction Spectrum Imaging restriction score (RSIrs) is a quantitative biomarker for detecting clinically significant prostate cancer (csPCa). However, the quantitative value of the RSIrs is affected by imaging parameters such as echo time (TE). Purpose: The purpose of the present study is to develop a calibration method to account for differences in echo times and facilitate use of RSIrs as a quantitative biomarker for the detection of csPCa. Methods: This study included 197 consecutive patients who underwent MRI and biopsy examination; 97 were diagnosed with csPCa (grade group ≥ 2). RSI data were acquired three times during the same session: twice at minimum TE∼75ms and once at TE=90ms (TEmin 1 , TEmin 2 , and TE90, respectively). A proposed calibration method, trained on patients without csPCa, estimated a linear scaling factor (f) for each of the four diffusion compartments (C) of the RSI signal model. A linear regression model was determined to match C-maps of TE90 to the reference C-maps of TEmin 1 within the interval ranging from 95 th to 99 th percentile of signal intensity within the prostate. RSIrs comparisons were made at 98 th percentile within each patient's prostate. We compared RSIrs from calibrated TE90 (RSIrs TE90corr ) and uncorrected TE90 (RSIrs TE90 ) to RSIrs from reference TEmin 1 (RSIrs TEmin1 ) and repeated TEmin 2 (RSIrs TEmin2 ). Calibration performance was evaluated with sensitivity, specificity, area under the ROC curve, positive predicted value, negative predicted value, and F1-score. Results: Scaling factors for C 1 , C 2 , C 3 , and C 4 were estimated as 1.70, 1.38, 1.03, and 1.19, respectively. In non-csPCa cases, the 98 th percentile of RSIrs TEmin2 and RSIrs TEmin1 differed by 0.27±0.86SI (mean±standard deviation), whereas RSIrs TE90 differed from RSIrs TEmin1 by 1.81±1.20SI. After calibration, this bias was reduced to -0.41±1.20SI, representing a 78% reduction in absolute error. For patients with csPCa, the difference was 0.54±1.98SI between RSIrs TEmin2 and RSIrs TEmin1 and 2.28±2.06SI between RSIrs TE90 and RSIrs TEmin1 . After calibration, the mean difference decreased to -0.86SI, a 38% reduction in absolute error. At the Youden index for patient-level classification of csPCa (8.94SI), RSIrs TEmin1 has a sensitivity of 66% and a specificity of 72%. Prior to calibration, RSIrs TE90 at the same threshold tended to over-diagnose benign cases (sensitivity 44%, specificity 88%). Post-calibration, RSIrs TE90corr performs more similarly to the reference (sensitivity 71%, specificity 62%). Conclusion: The proposed linear calibration method produces similar quantitative biomarker values for acquisitions with different TE, reducing TE-induced error by 78% and 38% for non-csPCa and csPCa, respectively.

3.
Front Oncol ; 13: 1237720, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37781199

RESUMO

Purpose: Dynamic contrast-enhanced MRI (DCE) and apparent diffusion coefficient (ADC) are currently used to evaluate treatment response of breast cancer. The purpose of the current study was to evaluate the three-component Restriction Spectrum Imaging model (RSI3C), a recent diffusion-weighted MRI (DWI)-based tumor classification method, combined with elastic image registration, to automatically monitor breast tumor size throughout neoadjuvant therapy. Experimental design: Breast cancer patients (n=27) underwent multi-parametric 3T MRI at four time points during treatment. Elastically-registered DWI images were used to generate an automatic RSI3C response classifier, assessed against manual DCE tumor size measurements and mean ADC values. Predictions of therapy response during treatment and residual tumor post-treatment were assessed using non-pathological complete response (non-pCR) as an endpoint. Results: Ten patients experienced pCR. Prediction of non-pCR using ROC AUC (95% CI) for change in measured tumor size from pre-treatment time point to early-treatment time point was 0.65 (0.38-0.92) for the RSI3C classifier, 0.64 (0.36-0.91) for DCE, and 0.45 (0.16-0.75) for change in mean ADC. Sensitivity for detection of residual disease post-treatment was 0.71 (0.44-0.90) for the RSI3C classifier, compared to 0.88 (0.64-0.99) for DCE and 0.76 (0.50-0.93) for ADC. Specificity was 0.90 (0.56-1.00) for the RSI3C classifier, 0.70 (0.35-0.93) for DCE, and 0.50 (0.19-0.81) for ADC. Conclusion: The automatic RSI3C classifier with elastic image registration suggested prediction of response to treatment after only three weeks, and showed performance comparable to DCE for assessment of residual tumor post-therapy. RSI3C may guide clinical decision-making and enable tailored treatment regimens and cost-efficient evaluation of neoadjuvant therapy of breast cancer.

4.
Int J Radiat Oncol Biol Phys ; 117(5): 1145-1152, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37453559

RESUMO

PURPOSE: In a phase III randomized trial, adding a radiation boost to tumor(s) visible on MRI improved prostate cancer (PCa) disease-free and metastasis-free survival without additional toxicity. Radiation oncologists' ability to identify prostate tumors is critical to widely adopting intraprostatic tumor radiotherapy boost for patients. A diffusion MRI biomarker, called the Restriction Spectrum Imaging restriction score (RSIrs), has been shown to improve radiologists' identification of clinically significant PCa. We hypothesized that (1) radiation oncologists would find accurately delineating PCa tumors on conventional MRI challenging and (2) using RSIrs maps would improve radiation oncologists' accuracy for PCa tumor delineation. METHODS AND MATERIALS: In this multi-institutional, international, prospective study, 44 radiation oncologists (participants) and 2 expert radiologists (experts) contoured prostate tumors on 39 total patient cases using conventional MRI with or without RSIrs maps. Participant volumes were compared to the consensus expert volumes. Contouring accuracy metrics included percent overlap with expert volume, Dice coefficient, conformal number, and maximum distance beyond expert volume. RESULTS: 1604 participant volumes were produced. 40 of 44 participants (91%) completely missed ≥1 expert-defined target lesion without RSIrs, compared to 13 of 44 (30%) with RSIrs maps. On conventional MRI alone, 134 of 762 contour attempts (18%) completely missed the target, compared to 18 of 842 (2%) with RSIrs maps. Use of RSIrs maps improved all contour accuracy metrics by approximately 50% or more. Mixed effects modeling confirmed that RSIrs maps were the main variable driving improvement in all metrics. System Usability Scores indicated RSIrs maps significantly improved the contouring experience (72 vs. 58, p < 0.001). CONCLUSIONS: Radiation oncologists struggle with accurately delineating visible PCa tumors on conventional MRI. RSIrs maps improve radiation oncologists' ability to target MRI-visible tumors for prostate tumor boost.


Assuntos
Neoplasias da Próstata , Planejamento da Radioterapia Assistida por Computador , Masculino , Humanos , Estudos Prospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Radio-Oncologistas , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/patologia
5.
medRxiv ; 2023 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-36824958

RESUMO

Background: High b -value diffusion-weighted images (DWI) are used for detection of clinically significant prostate cancer (csPCa). To decrease scan time and improve signal-to-noise ratio, high b -value (>1000 s/mm 2 ) images are often synthesized instead of acquired. Purpose: Qualitatively and quantitatively compare synthesized DWI (sDWI) to acquired (aDWI) for detection of csPCa. Study Type: Retrospective. Subjects: 151 consecutive patients who underwent prostate MRI and biopsy. Sequence: Axial DWI with b =0, 500, 1000, and 2000 s/mm 2 using a 3T clinical scanner using a 32-channel phased-array body coil. Assessment: We synthesized DWI for b =2000 s/mm 2 via extrapolation based on monoexponential decay, using b =0 and b =500 s/mm 2 (sDWI 500 ) and b =0, b =500, and b =1000 s/mm 2 (sDWI 1000 ). Differences between sDWI and aDWI were evaluated within regions of interest (ROIs). The maximum DWI value within each ROI was evaluated for prediction of csPCa. Classification accuracy was also compared to Restriction Spectrum Imaging restriction score (RSIrs), a previously validated biomarker based on multi-exponential DWI. Statistical Tests: Discrimination of csPCa was evaluated via area under the receiver operating characteristic curve (AUC). Statistical significance was assessed using bootstrap difference (two-sided α=0.05). Results: Within the prostate, mean ± standard deviation of percent mean differences between sDWI and aDWI signal were -46±35% for sDWI 1000 and -67±24% for sDWI 500 . AUC for aDWI, sDWI 500, sDWI 1000 , and RSIrs within the prostate 0.62[95% confidence interval: 0.53, 0.71], 0.63[0.54, 0.72], 0.65[0.56, 0.73] and 0.78[0.71, 0.86], respectively. When considering the whole field of view, classification accuracy and qualitative image quality decreased notably for sDWI compared to aDWI and RSIrs. Data Conclusion: sDWI is qualitatively comparable to aDWI within the prostate. However, hyperintense artifacts are introduced with sDWI in the surrounding pelvic tissue that interfere with quantitative cancer detection and might mask metastases. In the prostate, RSIrs yields superior quantitative csPCa detection than sDWI or aDWI.

6.
Abdom Radiol (NY) ; 48(5): 1645-1662, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36750478

RESUMO

Breast cancer is the most common malignancy in women, and for women under 40, it is the leading cause of cancer-related deaths. A specific type of breast cancer is pregnancy-associated breast cancer, which is diagnosed during pregnancy, the first-year postpartum, or during lactation. Pregnancy-associated breast cancer is seen in 3/1000 pregnancies and is increasing in incidence as women delay pregnancy. This type of breast cancer is more aggressive, and not infrequently, there is a delay in diagnosis attributed to physiologic changes that occur during pregnancy and a lack of awareness among physicians. In this review, we discuss the demographics of pregnancy-associated breast cancer, provide differential considerations, and illustrate the multimodality imaging features to bring attention to the radiologist about this aggressive form of breast cancer.


Assuntos
Neoplasias da Mama , Complicações Neoplásicas na Gravidez , Gravidez , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Complicações Neoplásicas na Gravidez/diagnóstico por imagem , Complicações Neoplásicas na Gravidez/etiologia , Lactação , Período Pós-Parto , Incidência
7.
Eur Urol Open Sci ; 47: 20-28, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36601040

RESUMO

Background: Multiparametric magnetic resonance imaging (mpMRI) improves detection of clinically significant prostate cancer (csPCa), but the subjective Prostate Imaging Reporting and Data System (PI-RADS) system and quantitative apparent diffusion coefficient (ADC) are inconsistent. Restriction spectrum imaging (RSI) is an advanced diffusion-weighted MRI technique that yields a quantitative imaging biomarker for csPCa called the RSI restriction score (RSIrs). Objective: To evaluate RSIrs for automated patient-level detection of csPCa. Design setting and participants: We retrospectively studied all patients (n = 151) who underwent 3 T mpMRI and RSI (a 2-min sequence on a clinical scanner) for suspected prostate cancer at University of California San Diego during 2017-2019 and had prostate biopsy within 180 d of MRI. Intervention: We calculated the maximum RSIrs and minimum ADC within the prostate, and obtained PI-RADS v2.1 from medical records. Outcome measurements and statistical analysis: We compared the performance of RSIrs, ADC, and PI-RADS for the detection of csPCa (grade group ≥2) on the best available histopathology (biopsy or prostatectomy) using the area under the curve (AUC) with two-tailed α = 0.05. We also explored whether the combination of PI-RADS and RSIrs might be superior to PI-RADS alone and performed subset analyses within the peripheral and transition zones. Results and limitations: AUC values for ADC, RSIrs, and PI-RADS were 0.48 (95% confidence interval: 0.39, 0.58), 0.78 (0.70, 0.85), and 0.77 (0.70, 0.84), respectively. RSIrs and PI-RADS were each superior to ADC for patient-level detection of csPCa (p < 0.0001). RSIrs alone was comparable with PI-RADS (p = 0.8). The combination of PI-RADS and RSIrs had an AUC of 0.85 (0.78, 0.91) and was superior to either PI-RADS or RSIrs alone (p < 0.05). Similar patterns were seen in the peripheral and transition zones. Conclusions: RSIrs is a promising quantitative marker for patient-level csPCa detection, warranting a prospective study. Patient summary: We evaluated a rapid, advanced prostate magnetic resonance imaging technique called restriction spectrum imaging to see whether it could give an automated score that predicted the presence of clinically significant prostate cancer. The automated score worked about as well as expert radiologists' interpretation. The combination of the radiologists' scores and automated score might be better than either alone.

8.
Radiol Imaging Cancer ; 5(1): e210115, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36705559

RESUMO

Purpose To develop a multicompartmental signal model for whole-body diffusion-weighted imaging (DWI) and apply it to study the diffusion properties of normal tissue and metastatic prostate cancer bone lesions in vivo. Materials and Methods This prospective study (ClinicalTrials.gov: NCT03440554) included 139 men with prostate cancer (mean age, 70 years ± 9 [SD]). Multicompartmental models with two to four tissue compartments were fit to DWI data from whole-body scans to determine optimal compartmental diffusion coefficients. Bayesian information criterion (BIC) and model-fitting residuals were calculated to quantify model complexity and goodness of fit. Diffusion coefficients for the optimal model (having lowest BIC) were used to compute compartmental signal-contribution maps. The signal intensity ratio (SIR) of bone lesions to normal-appearing bone was measured on these signal-contribution maps and on conventional DWI scans and compared using paired t tests (α = .05). Two-sample t tests (α = .05) were used to compare compartmental signal fractions between lesions and normal-appearing bone. Results Lowest BIC was observed from the four-compartment model, with optimal compartmental diffusion coefficients of 0, 1.1 × 10-3, 2.8 × 10-3, and >3.0 ×10-2 mm2/sec. Fitting residuals from this model were significantly lower than from conventional apparent diffusion coefficient mapping (P < .001). Bone lesion SIR was significantly higher on signal-contribution maps of model compartments 1 and 2 than on conventional DWI scans (P < .008). The fraction of signal from compartments 2, 3, and 4 was also significantly different between metastatic bone lesions and normal-appearing bone tissue (P ≤ .02). Conclusion The four-compartment model best described whole-body diffusion properties. Compartmental signal contributions from this model can be used to examine prostate cancer bone involvement. Keywords: Whole-Body MRI, Diffusion-weighted Imaging, Restriction Spectrum Imaging, Diffusion Signal Model, Bone Metastases, Prostate Cancer Clinical trial registration no. NCT03440554 Supplemental material is available for this article. © RSNA, 2023 See also commentary by Margolis in this issue.


Assuntos
Neoplasias Ósseas , Neoplasias da Próstata , Masculino , Humanos , Idoso , Estudos Prospectivos , Teorema de Bayes , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário
9.
Front Oncol ; 12: 844790, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35880168

RESUMO

The role of diffusion weighted imaging (DWI) as a biomarker has been the subject of active investigation in the field of breast radiology. By quantifying the random motion of water within a voxel of tissue, DWI provides indirect metrics that reveal cellularity and architectural features. Studies show that data obtained from DWI may provide information related to the characterization, prognosis, and treatment response of breast cancer. The incorporation of DWI in breast imaging demonstrates its potential to serve as a non-invasive tool to help guide diagnosis and treatment. In this review, current technical literature of diffusion-weighted breast imaging will be discussed, in addition to clinical applications, advanced techniques, and emerging use in the field of radiomics.

10.
Cancers (Basel) ; 14(13)2022 06 30.
Artigo em Inglês | MEDLINE | ID: mdl-35804972

RESUMO

Diffusion-weighted MRI (DW-MRI) offers a potential adjunct to dynamic contrast-enhanced MRI to discriminate benign from malignant breast lesions by yielding quantitative information about tissue microstructure. Multi-component modeling of the DW-MRI signal over an extended b-value range (up to 3000 s/mm2) theoretically isolates the slowly diffusing (restricted) water component in tissues. Previously, a three-component restriction spectrum imaging (RSI) model demonstrated the ability to distinguish malignant lesions from healthy breast tissue. We further evaluated the utility of this three-component model to differentiate malignant from benign lesions and healthy tissue in 12 patients with known malignancy and synchronous pathology-proven benign lesions. The signal contributions from three distinct diffusion compartments were measured to generate parametric maps corresponding to diffusivity on a voxel-wise basis. The three-component model discriminated malignant from benign and healthy tissue, particularly using the restricted diffusion C1 compartment and product of the restricted and intermediate diffusion compartments (C1 and C2). However, benign lesions and healthy tissue did not significantly differ in diffusion characteristics. Quantitative discrimination of these three tissue types (malignant, benign, and healthy) in non-pre-defined lesions may enhance the clinical utility of DW-MRI in reducing excessive biopsies and aiding in surveillance and surgical evaluation without repeated exposure to gadolinium contrast.

12.
Sci Rep ; 12(1): 265, 2022 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-34997164

RESUMO

Diffusion-weighted magnetic resonance imaging (DWI) of the musculoskeletal system has various applications, including visualization of bone tumors. However, DWI acquired with echo-planar imaging is susceptible to distortions due to static magnetic field inhomogeneities. This study aimed to estimate spatial displacements of bone and to examine whether distortion corrected DWI images more accurately reflect underlying anatomy. Whole-body MRI data from 127 prostate cancer patients were analyzed. The reverse polarity gradient (RPG) technique was applied to DWI data to estimate voxel-level distortions and to produce a distortion corrected DWI dataset. First, an anatomic landmark analysis was conducted, in which corresponding vertebral landmarks on DWI and anatomic T2-weighted images were annotated. Changes in distance between DWI- and T2-defined landmarks (i.e., changes in error) after distortion correction were calculated. In secondary analyses, distortion estimates from RPG were used to assess spatial displacements of bone metastases. Lastly, changes in mutual information between DWI and T2-weighted images of bone metastases after distortion correction were calculated. Distortion correction reduced anatomic error of vertebral DWI up to 29 mm. Error reductions were consistent across subjects (Wilcoxon signed-rank p < 10-20). On average (± SD), participants' largest error reduction was 11.8 mm (± 3.6). Mean (95% CI) displacement of bone lesions was 6.0 mm (95% CI 5.0-7.2); maximum displacement was 17.1 mm. Corrected diffusion images were more similar to structural MRI, as evidenced by consistent increases in mutual information (Wilcoxon signed-rank p < 10-12). These findings support the use of distortion correction techniques to improve localization of bone on DWI.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Neoplasias da Próstata/patologia , Imagem Corporal Total , Artefatos , Neoplasias Ósseas/secundário , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes
13.
Magn Reson Med ; 87(4): 1938-1951, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34904726

RESUMO

PURPOSE: Restriction spectrum imaging (RSI) decomposes the diffusion-weighted MRI signal into separate components of known apparent diffusion coefficients (ADCs). The number of diffusion components and optimal ADCs for RSI are organ-specific and determined empirically. The purpose of this work was to determine the RSI model for breast tissues. METHODS: The diffusion-weighted MRI signal was described using a linear combination of multiple exponential components. A set of ADC values was estimated to fit voxels in cancer and control ROIs. Later, the signal contributions of each diffusion component were estimated using these fixed ADC values. Relative-fitting residuals and Bayesian information criterion were assessed. Contrast-to-noise ratio between cancer and fibroglandular tissue in RSI-derived signal contribution maps was compared to DCE imaging. RESULTS: A total of 74 women with breast cancer were scanned at 3.0 Tesla MRI. The fitting residuals of conventional ADC and Bayesian information criterion suggest that a 3-component model improves the characterization of the diffusion signal over a biexponential model. Estimated ADCs of triexponential model were D1,3 = 0, D2,3 = 1.5 × 10-3 , and D3,3 = 10.8 × 10-3 mm2 /s. The RSI-derived signal contributions of the slower diffusion components were larger in tumors than in fibroglandular tissues. Further, the contrast-to-noise and specificity at 80% sensitivity of DCE and a subset of RSI-derived maps were equivalent. CONCLUSION: Breast diffusion-weighted MRI signal was best described using a triexponential model. Tumor conspicuity in breast RSI model is comparable to that of DCE without the use of exogenous contrast. These data may be used as differential features between healthy and malignant breast tissues.


Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Teorema de Bayes , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Meios de Contraste , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade
14.
J Magn Reson Imaging ; 54(3): 975-984, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33786915

RESUMO

BACKGROUND: Diffusion magnetic resonance imaging (MRI) is integral to detection of prostate cancer (PCa), but conventional apparent diffusion coefficient (ADC) cannot capture the complexity of prostate tissues and tends to yield noisy images that do not distinctly highlight cancer. A four-compartment restriction spectrum imaging (RSI4 ) model was recently found to optimally characterize pelvic diffusion signals, and the model coefficient for the slowest diffusion compartment, RSI4 -C1 , yielded greatest tumor conspicuity. PURPOSE: To evaluate the slowest diffusion compartment of a four-compartment spectrum imaging model (RSI4 -C1 ) as a quantitative voxel-level classifier of PCa. STUDY TYPE: Retrospective. SUBJECTS: Forty-six men who underwent an extended MRI acquisition protocol for suspected PCa. Twenty-three men had benign prostates, and the other 23 men had PCa. FIELD STRENGTH/SEQUENCE: A 3 T, multishell diffusion-weighted and axial T2-weighted sequences. ASSESSMENT: High-confidence cancer voxels were delineated by expert consensus, using imaging data and biopsy results. The entire prostate was considered benign in patients with no detectable cancer. Diffusion images were used to calculate RSI4 -C1 and conventional ADC. Classifier images were also generated. STATISTICAL TESTS: Voxel-level discrimination of PCa from benign prostate tissue was assessed via receiver operating characteristic (ROC) curves generated by bootstrapping with patient-level case resampling. RSI4 -C1 was compared to conventional ADC for two metrics: area under the ROC curve (AUC) and false-positive rate for a sensitivity of 90% (FPR90 ). Statistical significance was assessed using bootstrap difference with two-sided α = 0.05. RESULTS: RSI4 -C1 outperformed conventional ADC, with greater AUC (mean 0.977 [95% CI: 0.951-0.991] vs. 0.922 [0.878-0.948]) and lower FPR90 (0.032 [0.009-0.082] vs. 0.201 [0.132-0.290]). These improvements were statistically significant (P < 0.05). DATA CONCLUSION: RSI4 -C1 yielded a quantitative, voxel-level classifier of PCa that was superior to conventional ADC. RSI classifier images with a low false-positive rate might improve PCa detection and facilitate clinical applications like targeted biopsy and treatment planning. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 2.


Assuntos
Neoplasias da Próstata , Imagem de Difusão por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Curva ROC , Estudos Retrospectivos
15.
J Magn Reson Imaging ; 53(2): 628-639, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33131186

RESUMO

BACKGROUND: Multicompartmental modeling outperforms conventional diffusion-weighted imaging (DWI) in the assessment of prostate cancer. Optimized multicompartmental models could further improve the detection and characterization of prostate cancer. PURPOSE: To optimize multicompartmental signal models and apply them to study diffusion in normal and cancerous prostate tissue in vivo. STUDY TYPE: Retrospective. SUBJECTS: Forty-six patients who underwent MRI examination for suspected prostate cancer; 23 had prostate cancer and 23 had no detectable cancer. FIELD STRENGTH/SEQUENCE: 3T multishell diffusion-weighted sequence. ASSESSMENT: Multicompartmental models with 2-5 tissue compartments were fit to DWI data from the prostate to determine optimal compartmental apparent diffusion coefficients (ADCs). These ADCs were used to compute signal contributions from the different compartments. The Bayesian Information Criterion (BIC) and model-fitting residuals were calculated to quantify model complexity and goodness-of-fit. Tumor contrast-to-noise ratio (CNR) and tumor-to-background signal intensity ratio (SIR) were computed for conventional DWI and multicompartmental signal-contribution maps. STATISTICAL TESTS: Analysis of variance (ANOVA) and two-sample t-tests (α = 0.05) were used to compare fitting residuals between prostate regions and between multicompartmental models. T-tests (α = 0.05) were also used to assess differences in compartmental signal-fraction between tissue types and CNR/SIR between conventional DWI and multicompartmental models. RESULTS: The lowest BIC was observed from the 4-compartment model, with optimal ADCs of 5.2e-4, 1.9e-3, 3.0e-3, and >3.0e-2 mm2 /sec. Fitting residuals from multicompartmental models were significantly lower than from conventional ADC mapping (P < 0.05). Residuals were lowest in the peripheral zone and highest in tumors. Tumor tissue showed the largest reduction in fitting residual by increasing model order. Tumors had a greater proportion of signal from compartment 1 than normal tissue (P < 0.05). Tumor CNR and SIR were greater on compartment-1 signal maps than conventional DWI (P < 0.05) and increased with model order. DATA CONCLUSION: The 4-compartment signal model best described diffusion in the prostate. Compartmental signal contributions revealed by this model may improve assessment of prostate cancer. Level of Evidence 3 Technical Efficacy Stage 3 J. MAGN. RESON. IMAGING 2021;53:628-639.


Assuntos
Neoplasias da Próstata , Teorema de Bayes , Imagem de Difusão por Ressonância Magnética , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos
16.
AJR Am J Roentgenol ; 216(4): 860-873, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33295802

RESUMO

BI-RADS is a communication and data tracking system that has evolved since its inception as a brief mammography lexicon and reporting guide into a robust structured reporting platform and comprehensive quality assurance tool for mammography, ultrasound, and MRI. Consistent and appropriate use of the BI-RADS lexicon terminology and assessment categories effectively communicates findings, estimates the risk of malignancy, and provides management recommendations to patients and referring clinicians. The impact of BI-RADS currently extends internationally through six language translations. A condensed version has been proposed to facilitate a phased implementation of BI-RADS in resource-constrained regions. The primary advance of the 5th edition of BI-RADS is harmonization of the lexicon terms across mammography, ultrasound, and MRI. Harmonization has also been achieved across these modalities for the reporting structure, assessment categories, management recommendations, and data tracking system. Areas for improvement relate to certain common findings that lack lexicon descriptors and a need for further clarification of proper use of category 3. BI-RADS is anticipated to continue to evolve for application to a range of emerging breast imaging modalities.


Assuntos
Mama/diagnóstico por imagem , Mamografia , Imagem Multimodal , Neoplasias da Mama/diagnóstico por imagem , Feminino , Previsões , Gestão da Informação em Saúde/métodos , Gestão da Informação em Saúde/tendências , Humanos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/tendências , Mamografia/métodos , Mamografia/normas , Mamografia/tendências , Imagem Multimodal/métodos , Imagem Multimodal/tendências , Ultrassonografia Mamária/métodos , Ultrassonografia Mamária/tendências
17.
Clin Cancer Res ; 27(4): 1094-1104, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-33148675

RESUMO

PURPOSE: Diffusion-weighted MRI (DW-MRI) is a contrast-free modality that has demonstrated ability to discriminate between predefined benign and malignant breast lesions. However, how well DW-MRI discriminates cancer from all other breast tissue voxels in a clinical setting is unknown. Here we explore the voxelwise ability to distinguish cancer from healthy breast tissue using signal contributions from the newly developed three-component multi-b-value DW-MRI model. EXPERIMENTAL DESIGN: Patients with pathology-proven breast cancer from two datasets (n = 81 and n = 25) underwent multi-b-value DW-MRI. The three-component signal contributions C 1 and C 2 and their product, C 1 C 2, and signal fractions F 1, F 2, and F 1 F 2 were compared with the image defined on maximum b-value (DWI max), conventional apparent diffusion coefficient (ADC), and apparent diffusion kurtosis (K app). The ability to discriminate between cancer and healthy breast tissue was assessed by the false-positive rate given a sensitivity of 80% (FPR80) and ROC AUC. RESULTS: Mean FPR80 for both datasets was 0.016 [95% confidence interval (CI), 0.008-0.024] for C 1 C 2, 0.136 (95% CI, 0.092-0.180) for C 1, 0.068 (95% CI, 0.049-0.087) for C 2, 0.462 (95% CI, 0.425-0.499) for F 1 F 2, 0.832 (95% CI, 0.797-0.868) for F 1, 0.176 (95% CI, 0.150-0.203) for F 2, 0.159 (95% CI, 0.114-0.204) for DWI max, 0.731 (95% CI, 0.692-0.770) for ADC, and 0.684 (95% CI, 0.660-0.709) for K app. Mean ROC AUC for C 1 C 2 was 0.984 (95% CI, 0.977-0.991). CONCLUSIONS: The C 1 C 2 parameter of the three-component model yields a clinically useful discrimination between cancer and healthy breast tissue, superior to other DW-MRI methods and obliviating predefining lesions. This novel DW-MRI method may serve as noncontrast alternative to standard-of-care dynamic contrast-enhanced MRI.


Assuntos
Neoplasias da Mama/diagnóstico , Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/patologia , Neoplasias da Mama/patologia , Conjuntos de Dados como Assunto , Diagnóstico Diferencial , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Curva ROC , Adulto Jovem
18.
Radiol Case Rep ; 15(11): 2358-2361, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32994841

RESUMO

Magnetic resonance imaging (MRI) is used for preoperative evaluation, high-risk screening, and other select indications for breast cancer. However, the interpretation of breast MR images in pregnant and lactating women is complicated by physiologic changes of the breast that may result in marked background enhancement. Breast MRI with contrast administration is contraindicated in pregnancy. Restriction spectrum imaging (RSI) is an advanced diffusion-weighted (DW)-MRI method that theoretically reflects signal from cells with high nuclear-to-cytoplasm ratio without gadolinium-based contrast. This report describes a case in which RSI notably increased tumor conspicuity in a lactating woman, compared to contrast-enhanced (CE)-MRI and conventional DW-MRI.

19.
J Ultrasound Med ; 39(8): 1601-1614, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32118312

RESUMO

OBJECTIVES: To investigate prenatal imaging findings supporting a diagnosis of suspected septo-optic dysplasia (SOD) by fetal ultrasound (US), magnetic resonance imaging (MRI), or both. METHODS: A retrospective review identified 11 patients with SOD: 9 had a clinical diagnosis of SOD postnatally, and 2 were terminated on the basis of suspicious prenatal imaging. Prenatal and neonatal imaging of the cavum septi pellucidi (CSP), frontal horns (FHs), and lateral ventricles was evaluated. RESULTS: The appearance of the CSP varied on US and MRI. Complete ("fused") FHs or partial absence of the CSP was reported in 6 of 11 patients by fetal US and 7 of 8 patients by fetal MRI. The diagnosis of SOD was prospectively suspected prenatally in 6 of 11 and in an additional 5 of 11 cases retrospectively. Fetal MRI incorrectly initially reported normal morphologic abnormalities for 2 cases with partial absence of the CSP, whereas US accurately identified the morphologic abnormalities in 1 of these cases before MRI. Imaging features were first suggested at anatomic US (4 patients) and follow-up prenatal US (2 patients). Neonatal imaging was concordant in all 9 live births: 5 completely absent CSP, 3 partially absent CSP, and 1 completely present CSP. Clinical manifestations included optic nerve hypoplasia (9 of 9), panhypopituitarism (5 of 9), and neurodevelopmental delays. CONCLUSIONS: Primary imaging features of SOD are "continuous" FHs with complete or partial absence of the CSP. Septo-optic dysplasia can be suspected in utero and can appear isolated but has substantial associated central nervous system anomalies identified on fetal MRI or after birth. Partial absence of the CSP can be a prenatal sign of suspected SOD, although fetal MRI lacked the spatial resolution to identify it accurately in all cases.


Assuntos
Displasia Septo-Óptica , Feminino , Humanos , Recém-Nascido , Imageamento por Ressonância Magnética , Gravidez , Estudos Retrospectivos , Displasia Septo-Óptica/diagnóstico por imagem , Septo Pelúcido/diagnóstico por imagem , Ultrassonografia Pré-Natal
20.
Magn Reson Med ; 84(2): 1011-1023, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31975448

RESUMO

PURPOSE: To evaluate different non-Gaussian representations for the diffusion-weighted imaging (DWI) signal in the b-value range 200 to 3000 s/mm2 in benign and malignant breast lesions. METHODS: Forty-three patients diagnosed with benign (n = 18) or malignant (n = 25) tumors of the breast underwent DWI (b-values 200, 600, 1200, 1800, 2400, and 3000 s/mm2 ). Six different representations were fit to the average signal from regions of interest (ROIs) at different b-value ranges. Quality of fit was assessed by the corrected Akaike information criterion (AICc), and the Friedman test was used for assessing representation ranks. The area under the curve (AUC) of receiver operating characteristic curves were used to evaluate the power of derived parameters to differentiate between malignant and benign lesions. The lesion ROI was divided in central and peripheral parts to assess potential effect of heterogeneity. Sensitivity to noise-floor correction was also evaluated. RESULTS: The Padé exponent was ranked as the best based on AICc, whereas 3 models (kurtosis, fractional, and biexponential) achieved the highest AUC = 0.99 for lesion differentiation. The monoexponential model at bmax = 600 s/mm2 already provides AUC = 0.96, with considerably shorter acquisition time and simpler analysis. Significant differences between central and peripheral parts of lesions were found in malignant lesions. The mono- and biexponential models were most stable against varying degrees of noise-floor correction. CONCLUSION: Non-Gaussian representations are required for fitting of the DWI curve at high b-values in breast lesions. However, the added clinical value from the high b-value data for differentiation of benign and malignant lesions is not clear.


Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Humanos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA