Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Am J Gastroenterol ; 119(4): 662-670, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37795907

RESUMO

INTRODUCTION: Endoscopic eradication therapy (EET) is standard of care for T1a esophageal adenocarcinoma (EAC). However, data on outcomes in high-risk T1a EAC are limited. We assessed and compared outcomes after EET of low-risk and high-risk T1a EAC, including intraluminal EAC recurrence, extraesophageal metastases, and overall survival. METHODS: Patients who underwent EET for T1a EAC at 3 referral Barrett's esophagus endotherapy units between 1996 and 2022 were included. Patients with submucosal invasion, positive deep margins, or metastases at initial diagnosis were excluded. High-risk T1a EAC was defined as T1a EAC with poor differentiation and/or lymphovascular invasion, with low-risk disease being defined without these features. All pathology was systematically assessed by expert gastrointestinal pathologists. Baseline and follow-up endoscopy and pathology data were abstracted. Time-to-event analyses were performed to compare outcomes between groups. RESULTS: One hundred eighty-eight patients with T1a EAC were included (high risk, n = 45; low risk, n = 143) with a median age of 70 years, and 84% were men. Groups were comparable for age, sex, Barrett's esophagus length, lesion size, and EET technique. Rates of delayed extraesophageal metastases (11.1% vs 1.4%) were significantly higher in the high-risk group ( P = 0.02). There was no significant difference in the rates of intraluminal EAC recurrence ( P = 0.79) and overall survival ( P = 0.73) between the 2 groups. DISCUSSION: Patients with high-risk T1a EAC undergoing successful EET had a substantially higher rate of extraesophageal metastases compared with those with low-risk T1a EAC on long-term follow-up. These data should be factored into discussions with patients while selecting treatment approaches. Additional prospective data in this area are critical.


Assuntos
Adenocarcinoma , Esôfago de Barrett , Neoplasias Esofágicas , Masculino , Humanos , Idoso , Feminino , Esôfago de Barrett/cirurgia , Esôfago de Barrett/patologia , Estudos Prospectivos , Neoplasias Esofágicas/patologia , Adenocarcinoma/patologia , Endoscopia Gastrointestinal
2.
Gastrointest Endosc ; 98(5): 713-721, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37356631

RESUMO

BACKGROUND AND AIMS: Endoscopic eradication therapy (EET) is guideline endorsed for management of early-stage (T1) esophageal adenocarcinoma (EAC). Patients with baseline high-grade dysplasia (HGD) and EAC are at highest risk of recurrence after successful EET, but limited data exist on long-term (>5 year) recurrence outcomes. Our aim was to assess the incidence and predictors of long-term recurrence in a multicenter cohort of patients with T1 EAC treated with EET. METHODS: Patients with T1 EAC achieving successful endoscopic cancer eradication with a minimum of 5 years' clinical follow-up were included. The primary outcome was neoplastic recurrence, defined as dysplasia or EAC, and it was characterized as early (<2 years), intermediate (2-5 years), or late (>5 years). Predictors of recurrence were assessed by time to event analysis. RESULTS: A total of 84 T1 EAC patients (75 T1a, 9 T1b) with a median 9.1 years (range, 5.1-18.3 years) of follow-up were included. The overall incidence of neoplastic recurrence was 2.0 per 100 person-years of follow-up. Seven recurrences (3 dysplasia, 4 EAC) occurred after 5 years of EAC remission. Overall, 88% of recurrences were treated successfully endoscopically. EAC recurrence-related mortality occurred in 3 patients at a median of 5.2 years from EAC remission. Complete eradication of intestinal metaplasia was independently associated with reduced recurrence (hazard ratio, .13). CONCLUSIONS: Following successful EET of T1 EAC, neoplastic recurrence occurred after 5 years in 8.3% of cases. Careful long-term surveillance should be continued in this patient population. Complete eradication of intestinal metaplasia should be the therapeutic end point for EET.

3.
J Gastroenterol Hepatol ; 37(9): 1785-1791, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35613903

RESUMO

BACKGROUND AND AIM: Endoscopy featured water-aided colonoscopy (WAC) as novel in the Innovation Forum in 2011. Gastrointestinal Endoscopy published a modified Delphi consensus review (MDCR) that supports WAC for clinical practice in 2021. We tested the hypothesis that experience was an important predictor of WAC use, either as water immersion (WI), water exchange (WE), or a combination of WI and WE. METHODS: A questionnaire was sent by email to the MDCR authors with an in-depth knowledge of WAC. They responded and also invited colleagues and trainees without in-depth knowledge to respond. Logistic regression analysis was used with the reasons for WAC use treated as the primary outcome. Reports related to WAC post MDCR were identified. RESULTS: Of 100 respondents, > 80% indicated willingness to adopt and modify practice to accommodate WAC. Higher adenoma detection rate (ADR) incentivized WE use. Procedure time slots ≤ 30 and > 30 min significantly predicted WI and WE use, respectively. Co-authors of the MDCR were significantly more likely to perform WAC (odds ratio [OR] = 7.5, P = 0.037). Unfamiliarity with (OR = 0.11, P = 0.02) and absence of good experience (OR = 0.019, P = 0.002) were associated with colonoscopists less likely to perform WAC. Reports related to WAC post MDCR revealed overall and right colon WE outcomes continued to improve. Network meta-analyses showed that WE was superior to Cap and Endocuff. On-demand sedation with WE shortened nursing recovery time. CONCLUSIONS: An important predictor of WAC use was experience. Superior outcomes continued to be reported with WE.


Assuntos
Adenoma , Neoplasias Colorretais , Insuflação , Adenoma/diagnóstico , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Humanos , Insuflação/métodos , Inquéritos e Questionários , Água
4.
Clin Gastroenterol Hepatol ; 20(2): 362-371.e23, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33991691

RESUMO

BACKGROUND & AIMS: Nonpedunculated colorectal polyps are normally endoscopically removed to prevent neoplastic progression. Delayed bleeding is the most common major adverse event. Clipping the resection defect has been suggested to reduce delayed bleedings. Our aim was to determine if prophylactic clipping reduces delayed bleedings and to analyze the contribution of polyp characteristics, extent of defect closure, and antithrombotic use. METHODS: An individual patient data meta-analysis was performed. Studies on prophylactic clipping in nonpedunculated colorectal polyps were selected from PubMed, Embase, Web of Science, and Cochrane database (last selection, April 2020). Authors were invited to share original study data. The primary outcome was delayed bleeding ≤30 days. Multivariable mixed models were used to determine the efficacy of prophylactic clipping in various subgroups adjusted for confounders. RESULTS: Data of 5380 patients with 8948 resected polyps were included from 3 randomized controlled trials, 2 prospective, and 8 retrospective studies. Prophylactic clipping reduced delayed bleeding in proximal polyps ≥20 mm (odds ratio [OR], 0.62; 95% confidence interval [CI], 0.44-0.88; number needed to treat = 32), especially with antithrombotics (OR, 0.59; 95% CI, 0.35-0.99; number needed to treat = 23; subgroup of anticoagulants/double platelet inhibitors: n = 226; OR, 0.40; 95% CI, 0.16-1.01; number needed to treat = 12). Prophylactic clipping did not benefit distal polyps ≥20 mm with antithrombotics (OR, 1.41; 95% CI, 0.79-2.52). CONCLUSIONS: Prophylactic clipping reduces delayed bleeding after resection of nonpedunculated, proximal colorectal polyps ≥20 mm, especially in patients using antithrombotics. No benefit was found for distal polyps. Based on this study, patients can be identified who may benefit from prophylactic clipping. (PROSPERO registration number CRD42020104317.).


Assuntos
Pólipos do Colo , Pólipos do Colo/etiologia , Pólipos do Colo/cirurgia , Colonoscopia/efeitos adversos , Humanos , Hemorragia Pós-Operatória/epidemiologia , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/prevenção & controle , Estudos Prospectivos , Estudos Retrospectivos , Instrumentos Cirúrgicos
5.
Am J Gastroenterol ; 116(3): 517-521, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33657040

RESUMO

INTRODUCTION: Systemic sclerosis or scleroderma (SSc) is a chronic autoimmune disease that renders the esophagus prone to significant gastroesophageal reflux due to impaired esophageal clearance and reduced lower esophageal sphincter pressure. The reported prevalence of Barrett's esophagus (BE) in women with SSc varies from 2% to 37% and is derived from older studies with small sample sizes. We aimed to assess the prevalence of BE in a large cohort of women with SSc. METHODS: Women with SSc referred from the Mayo Clinic Arizona Rheumatology Clinic who completed esophagogastroduodenoscopy between 2002 and 2020 were included. Demographic and high-resolution manometry data were evaluated. The diagnosis of scleroderma was confirmed by an expert rheumatologist. The BE diagnosis was confirmed by an expert gastrointestinal pathologist. RESULTS: There were 235 women with SSc who underwent EGD. High-resolution manometry (HRM) was completed in 172 patients. Women with SSc with BE were significantly more likely to have scleroderma esophagus (absent contractility with hypotensive lower esophageal sphincter) on HRM than women with SSc without BE (P = 0.018). There were 30 patients with SSc (12.8%) with histologically proven BE. Dysplasia was found in 13 (43.3%): 4 with indefinite, 7 with low grade, and 2 with adenocarcinoma. The incidence of any dysplasia was 5.3% per year (0.9% per year for adenocarcinoma). DISCUSSION: This the largest study on prevalence of BE in women with SSc, yielding a prevalence of 12.8%. Women with SSc with BE were significantly more likely to have absent contractility with hypotensive lower esophageal sphincter findings on HRM. The high prevalence and incidence of dysplasia found suggest that women with SSc should be included in the screening recommendations for BE.


Assuntos
Transtornos de Deglutição/epidemiologia , Escleroderma Sistêmico/epidemiologia , Adulto , Idoso , Esôfago de Barrett , Comorbidade , Feminino , Humanos , Incidência , Manometria , Prevalência
6.
Gastrointest Endosc ; 93(4): 880-887.e1, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32739482

RESUMO

BACKGROUND AND AIMS: Radiofrequency ablation (RFA) is the preferred ablative modality for treating dysplastic Barrett's esophagus. The recently introduced self-sizing circumferential ablation catheter eliminates the need for a sizing balloon. Although it enhances efficiency, outcomes have not been compared with the previous manual-sizing catheter. We evaluated the comparative safety and efficacy of these 2 ablation systems in a large, multicenter cohort. METHODS: Patients undergoing RFA at 3 tertiary care centers from 2005 to 2018 were included. Circumferential RFA was performed in a standard fashion, followed by focal RFA as needed. Outcomes were compared between the self-sizing and manual-sizing groups. The primary outcome was the rate of adverse events, including strictures, perforation, and bleeding. Secondary outcomes were procedure time and treatment efficacy, as assessed by rates and time to complete eradication of dysplasia (CE-D) and intestinal metaplasia (CE-IM). RESULTS: Three hundred eighteen patients were included, 90 (28.3%) treated with the self-sizing catheter and 228 (71.7%) with the manual-sizing catheter. Twenty-one patients (6.6%) developed strictures (8 [8.9%] in the self-sizing group and 13 [5.7%] in the manual-sizing group, P = .32). Of the self-sizing strictures, 75% occurred at the 12J dose before widespread adoption of the current 10J treatment standard. One patient developed bleeding, and no perforations were encountered. Procedure time was significantly shorter in the self-sizing group. No significant differences were observed in rates of and time to CE-D and CE-IM. CONCLUSIONS: These findings suggest that both systems are comparable in safety and efficacy. The use of the self-sizing system may enhance the efficiency of RFA for treating dysplastic Barrett's esophagus.


Assuntos
Esôfago de Barrett , Ablação por Cateter , Neoplasias Esofágicas , Esôfago de Barrett/cirurgia , Catéteres , Estudos de Coortes , Neoplasias Esofágicas/cirurgia , Esofagoscopia , Humanos , Resultado do Tratamento
7.
BMC Gastroenterol ; 20(1): 227, 2020 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-32660521

RESUMO

BACKGROUND: Inpatient status has been shown to be a predictor of poor bowel preparation for colonoscopy; however, the optimal bowel preparation regimen for hospitalized patients is unknown. Our aim was to compare the efficacy of bowel preparation volume size in hospitalized patients undergoing inpatient colonoscopy. METHODS: This prospective, single blinded (endoscopist), randomized controlled trial was conducted as a pilot study at a tertiary referral medical center. Hospitalized patients undergoing inpatient colonoscopy were assigned randomly to receive a high, medium, or low-volume preparation. Data collection included colon preparation quality, based on the Boston Bowel Preparation Scale, and a questionnaire given to all subjects evaluating the ability to completely finish bowel preparation and adverse effects (unpleasant taste, nausea, and vomiting). RESULTS: Twenty-five colonoscopies were performed in 25 subjects. Patients who received low-volume preparation averaged a higher mean total BBPS (7.4, SD 1.62), in comparison to patients who received high-volume (7.0, SD 1.41) and medium-volume prep (6.9, SD 1.55), P = 0.77. When evaluating taste a higher score meant worse taste. The low-volume group scored unpleasant taste as 0.6 (0.74), while the high-volume group gave unpleasant taste a score of 2.2 (0.97) and the medium-volume group gave a score of 2.1 (1.36), P < 0.01. CONCLUSION: In this pilot study we found that low-volume colon preparation may be preferred in the inpatient setting due its better rate of tolerability and comparable bowel cleanliness when compared to larger volume preparation, although we cannot overreach any definitive conclusion. Further more robust studies are required to confirm these findings. TRIAL REGISTRATION: The Affect of Low-Volume Bowel Preparation for Hospitalized Patients Colonoscopies. TRIAL REGISTRATION: NCT01978509 (terminated). Retrospectively registered on November 07, 2013.


Assuntos
Colonoscopia , Pacientes Internados , Catárticos/efeitos adversos , Colo , Humanos , Projetos Piloto , Polietilenoglicóis , Estudos Prospectivos , Método Simples-Cego
8.
Gastroenterology ; 156(8): 2198-2207.e1, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30742834

RESUMO

BACKGROUND & AIMS: Topically applied methylene blue dye chromoendoscopy is effective in improving detection of colorectal neoplasia. When combined with a pH- and time-dependent multimatrix structure, a per-oral methylene blue formulation (MB-MMX) can be delivered directly to the colorectal mucosa. METHODS: We performed a phase 3 study of 1205 patients scheduled for colorectal cancer screening or surveillance colonoscopies (50-75 years old) at 20 sites in Europe and the United States, from December 2013 through October 2016. Patients were randomly assigned to groups given 200 mg MB-MMX, placebo, or 100 mg MB-MMX (ratio of 2:2:1). The 100-mg MB-MMX group was included for masking purposes. MB-MMX and placebo tablets were administered with a 4-L polyethylene glycol-based bowel preparation. The patients then underwent colonoscopy by an experienced endoscopist with centralized double-reading. The primary endpoint was the proportion of patients with 1 adenoma or carcinoma (adenoma detection rate [ADR]). We calculated odds ratios (ORs) and 95% confidence intervals (CIs) for differences in detection between the 200-mg MB-MMX and placebo groups. False-positive (resection rate for non-neoplastic polyps) and adverse events were assessed as secondary endpoints. RESULTS: The ADR was higher for the MB-MMX group (273 of 485 patients, 56.29%) than the placebo group (229 of 479 patients, 47.81%) (OR 1.46; 95% CI 1.09-1.96). The proportion of patients with nonpolypoid lesions was higher in the MB-MMX group (213 of 485 patients, 43.92%) than the placebo group (168 of 479 patients, 35.07%) (OR 1.66; 95% CI 1.21-2.26). The proportion of patients with adenomas ≤5 mm was higher in the MB-MMX group (180 of 485 patients, 37.11%) than the placebo group (148 of 479 patients, 30.90%) (OR 1.36; 95% CI 1.01-1.83), but there was no difference between groups in detection of polypoid or larger lesions. The false-positive rate did not differ significantly between groups (83 [23.31%] of 356 patients with non-neoplastic lesions in the MB-MMX vs 97 [29.75%] of 326 patients with non-neoplastic lesions in the placebo group). Overall, 0.7% of patients had severe adverse events but there was no significant difference between groups. CONCLUSIONS: In a phase 3 trial of patients undergoing screening or surveillance colonoscopies, we found MB-MMX led to an absolute 8.5% increase in ADR, compared with placebo, without increasing the removal of non-neoplastic lesions. Clinicaltrials.gov no: NCT01694966.


Assuntos
Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Aumento da Imagem/métodos , Azul de Metileno/administração & dosagem , Administração Oral , Idoso , Método Duplo-Cego , Europa (Continente) , Feminino , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Estados Unidos
9.
J Clin Gastroenterol ; 53(5): 361-365, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29608452

RESUMO

GOALS: To investigate factors predictive of progression from nondysplastic Barrett esophagus (NDBE) or low-grade dysplasia (LGD) to high-grade dysplasia (HGD) or esophageal adenocarcinoma (EAC) using a large, prospective cohort of patients, wherein all esophageal biopsies undergo expert gastrointestinal pathologist review. BACKGROUND: Efficacy and cost-effectiveness of endoscopic surveillance to detect incident EAC in the setting of Barrett esophagus (BE), particularly in NDBE patients, is questioned. Previous studies have reported factors predictive of progression to EAC to guide surveillance intervals, but their strength is limited by small sample size and absence of expert gastrointestinal pathologist involvement in esophageal biopsy review. STUDY: NDBE and LGD subjects were identified from a prospective registry in a tertiary care center. "Progressors" were BE subjects who developed HGD/EAC>12 months after the initial NDBE or LGD diagnosis. Cox proportional hazards model were used to identify predictors of progression. RESULTS: In total, 318 with NDBE and 301 with BE-LGD (mean age, 62.6 y, 85% male) were included. The mean follow-up was 5.3 years. The 7 NDBE and 21 LGD subjects progressed to HGD/EAC. BE length [hazards ratio (HR), 1.16; 95% confidence interval (CI), 1.03-1.29], presence of nodularity (HR, 4.98; 95% CI, 1.80-11.7), and baseline LGD (HR, 2.57; 95% CI, 1.13-6.57) were significant predictors of progression on multivariate analysis. CONCLUSIONS: In this well-defined cohort of NDBE and BE-LGD subjects, BE length, presence of LGD, and nodularity were independent predictors of progression to HGD/EAC. These factors may aid in identifying high-risk patients who may benefit from closer endoscopic surveillance/therapy.


Assuntos
Adenocarcinoma/patologia , Esôfago de Barrett/patologia , Transtornos de Deglutição/etiologia , Neoplasias Esofágicas/patologia , Índice de Gravidade de Doença , Adenocarcinoma/complicações , Esôfago de Barrett/complicações , Estudos de Coortes , Progressão da Doença , Neoplasias Esofágicas/complicações , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Lesões Pré-Cancerosas , Valor Preditivo dos Testes , Estudos Prospectivos , Estados Unidos
10.
Gastrointest Endosc ; 89(4): 759-768, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30447215

RESUMO

BACKGROUND AND AIMS: There is controversy about finding intestinal metaplasia (IM) of the gastric cardia on biopsy. The most recent American College of Gastroenterology guideline comments that IM cardia is not more common in patients with Barrett's esophagus (BE). It provides limited guidance on whether the cardia should be treated when patients with BE undergo endoscopic eradication therapy (EET) and whether the cardia should undergo biopsy after ablation. The aims of our study were to determine the frequency in the proximal stomach of (1) histologic gastric cardia mucosa and (2) IM cardia. A third aim was to explore the frequency of advanced pathology (dysplasia and adenocarcinoma) in the cardia after patients with BE have undergone EET. METHODS: Consecutive patients undergoing esophagogastroduodenoscopy between January 2008 and December 2014 who had proximal stomach biopsies were included. Patients who had histologically confirmed BE were compared with those without BE. RESULTS: Four hundred sixty-two patients, 289 with BE and 173 without BE, were included. Histologically confirmed cardiac mucosa was found in 81.6% of all patients. This was more frequent in those with versus without BE (86% vs 75%; odds ratio [OR], 2.06; 95% confidence interval [CI], 1.28-3.32; P = .003). IM cardia was more common in the BE group (17% vs 7%; OR, 2.67; 95% CI, 1.38-5.19; P = .004). Advanced pathology was more likely in the patients with BE who had undergone EET. CONCLUSIONS: Cardiac mucosa is present in most patients who undergo endoscopy for upper GI symptoms. IM cardia is more common in patients with BE than those without. Advanced histologic changes in the cardia were seen only in the subgroup of patients with BE who had undergone EET.


Assuntos
Adenocarcinoma/patologia , Esôfago de Barrett/patologia , Cárdia/patologia , Mucosa Gástrica/patologia , Neoplasias Gástricas/patologia , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/epidemiologia , Idoso , Esôfago de Barrett/diagnóstico por imagem , Esôfago de Barrett/epidemiologia , Esôfago de Barrett/cirurgia , Cárdia/diagnóstico por imagem , Endoscopia do Sistema Digestório , Feminino , Mucosa Gástrica/diagnóstico por imagem , Humanos , Masculino , Metaplasia/diagnóstico por imagem , Metaplasia/epidemiologia , Metaplasia/patologia , Imagem de Banda Estreita , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/epidemiologia
11.
Ann Gastroenterol ; 31(2): 217-223, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29507469

RESUMO

BACKGROUND: The impact of Boston bowel preparation scale (BBPS) scores on the adenoma detection rate (ADR) in each segment has not been adequately addressed. The aim of this study was to determine the association between segmental or overall ADR and serrated polyp detection rate (SDR) with segmental and total BBPS scores. METHODS: All outpatient screening colonoscopies with documented BBPS scores were retrospectively reviewed at a tertiary institution from January to December 2013. Chi-square tests and logistic regression were used to analyze the detection rates of adenomas and serrated polyps with bowel prep scores. Odds ratios were calculated using logistic regression that controlled for withdrawal time, age, body mass index, diabetes status and sex. RESULTS: We analyzed 1991 colonoscopies. The overall ADR was 37.5% (95% confidence interval [CI], 35.3-39.6). There was a significant difference in the overall ADR, and in SDR across all bowel category groups, with total BBPS scores of 8 and 9 having lower detection rates than scores of 5, 6 and 7. As the quality of bowel preparation increased, there was a statistical decrease in the ADR (odds ratio [OR] 0.79 [CI 0.66-0.94], P=0.04) of the right colon, while in the left colon, there was a statistical decrease in SDR (OR 0.78, [CI 0.65-0.92] P=0.019). CONCLUSION: Segmental ADR and SDR both decreased as prep scores increased, decreasing notably in patients with excellent prep scores of 8 and 9. A possible explanation for this unexpected discrepancy may be related to longer and better visualization of the mucosa when cleansing and suctioning is necessary.

12.
J Gastroenterol Hepatol ; 33(3): 645-649, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28892839

RESUMO

BACKGROUND AND AIM: Feedback has been shown to improve performance in colonoscopy including adenoma detection rate (ADR). The frequency at which feedback should be given is unknown. As part of a quality improvement program, we sought to measure the outcome of providing quarterly and monthly feedback on colonoscopy quality measures. METHODS: All screening colonoscopies performed at endoscopy unit at Mayo Clinic Arizona by gastroenterologists between October 2010 and December 2012 were reviewed. Quality indicators, including ADR, were extracted for each individual endoscopist, and feedback was provided. The study period was divided into four distinct groups: pre-intervention that served as baseline, quarterly feedback, monthly feedback, and post-intervention. Based on ADR, endoscopists were grouped into "low detectors" (≤ 25%), "average detectors" (26-35%), and "high detectors" (> 35%). RESULTS: A total of 3420 screening colonoscopies were performed during the study period (555 patients during pre-intervention, 1209 patients during quarterly feedback, 599 during monthly feedback, and 1057 during the post-intervention period) by 16 gastroenterologists. The overall ADR for the group improved from 30.5% to 37.7% (P = 0.003). Compared with the pre-interventional period, all quality indicators measured significantly improved during the monthly feedback and post-intervention periods but not in the quarterly feedback period. CONCLUSIONS: In our quality improvement program, monthly feedback significantly improved colonoscopy quality measures, including ADR, while quarterly feedback did not. The impact of the intervention was most prominent in the "low detectors" group. Results were durable up to 6 months following the intervention.


Assuntos
Adenoma/diagnóstico , Colonoscopia , Neoplasias Colorretais/diagnóstico , Retroalimentação , Melhoria de Qualidade , Idoso , Detecção Precoce de Câncer , Feminino , Humanos , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Indicadores de Qualidade em Assistência à Saúde , Fatores de Tempo
15.
Am J Gastroenterol ; 112(6): 867-873, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28374813

RESUMO

OBJECTIVES: Low-grade dysplasia (LGD) is a risk factor for progression in Barrett's esophagus (BE). Progression estimates however vary and predictors of progression are not well established. We aimed to assess predictors of progression in a multicenter BE-LGD cohort. METHODS: All subjects with LGD (diagnosed by a GI pathologist) in a prospective BE registry were identified. Progression was defined development of HGD/EAC more than 12 months after index date of LGD diagnosis. Clinical, endoscopic factors and impact of histologic review by an independent panel of two GI pathologists were assessed as predictors of progression. Cox proportional hazard models were used to assess their association with risk of progression. RESULTS: 244 BE-LGD subjects met inclusion criteria. Their mean age was 63.2 years. 205 (84%) were males. The median follow up was 4.8 years. Fifty six patients were diagnosed with HGD/EAC in less than 12 months, while 14 progressed to HGD/EAC after 12 months, with an overall annual risk of progression of 1.2%. 29% of LGD subjects were downgraded to non-dysplastic and the remaining re-confirmed as LGD or indefinite dysplasia. The risk of progression in the reconfirmed LGD group was eight fold higher (hazards ratio: 7.6, 95% CI: 1.5-139.4) in a propensity score stratified model. CONCLUSIONS: In this large BE-LGD cohort, progression risk increased substantially when an additional panel of two expert GI pathologists re-confirmed a LGD diagnosis. These BE subjects may be candidates for endoscopic therapy. LGD was a marker of prevalent HGD/EAC in 18% of patients.


Assuntos
Adenocarcinoma/patologia , Esôfago de Barrett/patologia , Progressão da Doença , Neoplasias Esofágicas/patologia , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Pontuação de Propensão , Sistema de Registros , Fatores de Risco
16.
Gastroenterol Res Pract ; 2017: 7207595, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29445393

RESUMO

BACKGROUND: Adenoma detection rate (ADR) is a validated quality measure for screening colonoscopy, but there are little data for other indications. The distribution of adenomas is not well described for these indications. AIM: To describe ADR and the adenoma distribution in the proximal and distal colon based on colonoscopy indication. METHODS: Outpatient colonoscopies are subdivided by indication. PDR and ADR for the entire colon and for proximal and distal colon. Data were compared using generalized estimating equations to adjust for clustering amongst endoscopists while controlling for patient age and gender. RESULTS: 3436 colonoscopies were reviewed (51.2%: men (n = 1759)). Indications are screening 49.2%, surveillance 29.3%, change in bowel habit 8.4%, bleeding 5.8%, colitides 3.0%, pain 2.8%, and miscellaneous 1.5%. Overall ADR was 37% proximal ADR 28%, and distal ADR 17%. PDR and ADR were significantly higher in surveillance than in screening (PDR: 69% versus 51%; ADR: 50% versus 33%; p = 0.0001). Adenomas were more often detected in the proximal than in the distal colon, for all indications. CONCLUSIONS: Prevalence of polyps and adenomas differs based on colonoscopy indication. Adenoma detection is highest in surveillance and more commonly detected in the proximal colon. For quality assurance, distinct ADR and PDR targets may need to be established for different colonoscopy indications.

17.
Endosc Int Open ; 3(6): E621-6, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26716123

RESUMO

BACKGROUND AND STUDY AIMS: Gastroenterology trainees acquire skill and proficiency in performing colonoscopies at different rates. The cause for heterogeneous competency among the trainees is unclear. Kinematic analysis of the wrist joint while performing colonoscopy can objectively assess the variation in wrist motion. Our objective was to test the hypothesis that the time spent by the trainees in extreme ranges of wrist motion will decrease as the trainees advance through the fellowship year. SUBJECTS AND METHODS: Five first-year gastroenterology fellows were prospectively studied at four intervals while performing simulated colonoscopies. The setting was an endoscopy simulation laboratory at a tertiary care center. Kinematic assessment of wrist motion was done using a magnetic position/orientation tracker held in place by a custom-made arm sleeve and hand glove. The main outcome measure was time spent performing each of four ranges of wrist motion (mid, center, extreme, and out) for each wrist degree of freedom (pronation/supination, flexion/extension, and adduction/abduction). RESULTS: There were no statistically significant differences in the time spent for wrist movements across the three degrees of freedom throughout the study period. However, fellows spent significantly less time in extreme range (1.47 ±â€Š0.34 min vs. 2.44 ±â€Š0.34 min, P = 0.004) and center range (1.02 ±â€Š0.34 min vs 1.9 ±â€Š0.34 min, P = 0.01) at the end of the study compared to the baseline evaluation. The study was limited by the small number of subjects and performance of colonoscopies on a simulator rather than live patients. CONCLUSIONS: Gastroenterology trainees alter the time spent at the extreme range of wrist motion as they advance through training. Endoscopy training during the first 10 months of fellowship may have beneficial effects on learning ergonomically correct motion patterns.

18.
World J Gastrointest Endosc ; 7(5): 555-62, 2015 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-25992195

RESUMO

AIM: To compare the yield of adenomas between narrow band imaging and white light when using high definition/magnification. METHODS: This prospective, non-randomized comparative study was performed at the endoscopy unit of veteran affairs medical center in Phoenix, Arizona. Consecutive patients undergoing first average risk colorectal cancer screening colonoscopy were selected. Two experienced gastroenterologists performed all the procedures that were blinded to each other's findings. Demographic details were recorded. Data are presented as mean ± SEM. Proportional data were compared using the χ(2) test and means were compared using the Student's t test. Tandem colonoscopy was performed in a sequential and segmental fashion using one of 3 strategies: white light followed by narrow band imaging [Group A: white light (WL) → narrow band imaging (NBI)]; narrow band imaging followed by white light (Group B: NBI → WL) and, white light followed by white light (Group C: WL → WL). Detection rate of missed polyps and adenomas were evaluated in all three groups. RESULTS: Three hundred patients were studied (100 in each Group). Although the total time for the colonoscopy was similar in the 3 groups (23.8 ± 0.7, 22.2 ± 0.5 and 24.1 ± 0.7 min for Groups A, B and C, respectively), it reached statistical significance between Groups B and C (P < 0.05). The cecal intubation time in Groups B and C was longer than for Group A (6.5 ± 0.4 min and 6.5 ± 0.4 min vs 4.9 ± 0.3 min; P < 0.05). The withdrawal time for Groups A and C was longer than Group B (18.9 ± 0.7 min and 17.6 ± 0.6 min vs 15.7 ± 0.4 min; P < 0.05). Overall miss rate for polyps and adenomas detected in three groups during the second look was 18% and 17%, respectively (P = NS). Detection rate for polyps and adenomas after first look with white light was similar irrespective of the light used during the second look (WL → WL: 13.7% for polyps, 12.6% for adenomas; WL → NBI: 14.2% for polyps, 11.3% for adenomas). Miss rate of polyps and adenomas however was significantly higher when NBI was used first (29.3% and 30.3%, respectively; P < 0.05). Most missed adenomas were ≤ 5 mm in size. There was only one advanced neoplasia (defined by size only) missed during the first look. CONCLUSION: Our data suggest that the tandem nature of the procedure rather than the optical techniques was associated with the detection of additional polyps' and adenomas.

19.
World J Gastrointest Endosc ; 7(4): 328-35, 2015 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-25901211

RESUMO

Colonoscopy is the gold standard test for colorectal cancer screening. The primary advantage of colonoscopy as opposed to other screening modalities is the ability to provide therapy by removal of precancerous lesions at the time of detection. However, colonoscopy may miss clinically important neoplastic polyps. The value of colonoscopy in reducing incidence of colorectal cancer is dependent on many factors including, the patient, provider, and facility level. A high quality examination includes adequate bowel preparation, optimal colonoscopy technique, meticulous inspection during withdrawal, identification of subtle flat lesions, and complete polypectomy. Considerable variation among institutions and endoscopists has been reported in the literature. In attempt to diminish this disparity, various approaches have been advocated to improve the quality of colonoscopy. The overall impact of these interventions is not yet well defined. Implementing optimal education and training and subsequently analyzing the impact of these endeavors in improvement of quality will be essential to augment the utility of colonoscopy for the prevention of colorectal cancer.

20.
Gastrointest Endosc ; 82(2): 370-375.e1, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25843614

RESUMO

BACKGROUND: The frequency of nonneoplastic polypectomy (NNP) and its impact on the polyp detection rate (PDR) is unknown. The correlation between NNP and adenoma detection rate (ADR) and its impact on the cost of colonoscopy has not been investigated. OBJECTIVE: To determine the rate of NNP in screening colonoscopy, the impact of NNP on the PDR, and the correlation of NNP with ADR. The increased cost of NNP during screening colonoscopy also was calculated. DESIGN: We reviewed all screening colonoscopies. PDR and ADR were calculated. We then calculated a nonneoplastic polyp detection rate (patients with ≥1 nonneoplastic polyp). SETTING: Tertiary-care referral center. PATIENTS: Patients who underwent screening colonoscopies from 2010 to 2011. INTERVENTIONS: Colonoscopy. MAIN OUTCOME MEASUREMENTS: ADR, PDR, NNP rate. RESULTS: A total of 1797 colonoscopies were reviewed. Mean (±standard deviation) PDR was 47.7%±12.0%, and mean ADR was 27.3%±6.9%. The overall NNP rate was 10.4%±7.1%, with a range of 2.4% to 28.4%. Among all polypectomies (n=2061), 276 were for nonneoplastic polyps (13.4%). Endoscopists with a higher rate of nonneoplastic polyp detection were more likely to detect an adenoma (odds ratio 1.58; 95% confidence interval, 1.1-1.2). With one outlier excluded, there was a strong correlation between ADR and NNP (r=0.825; P<.001). The increased cost of removal of nonneoplastic polyps was $32,963. LIMITATIONS: Retrospective study. CONCLUSION: There is a strong correlation between adenoma detection and nonneoplastic polyp detection. The etiology is unclear, but nonneoplastic polyp detection rate may inflate the PDR for some endoscopists. NNP also adds an increased cost. Increasing the awareness of endoscopic appearances through advanced imaging techniques of normal versus neoplastic tissue may be an area to improve cost containment in screening colonoscopy.


Assuntos
Adenoma/diagnóstico , Pólipos do Colo/diagnóstico , Pólipos do Colo/cirurgia , Colonoscopia/estatística & dados numéricos , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/estatística & dados numéricos , Idoso , Pólipos do Colo/patologia , Colonoscopia/economia , Detecção Precoce de Câncer/economia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA