Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Neoplasia ; 21(11): 1085-1090, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31734629

RESUMO

Differentiating pancreatitis from pancreatic cancer would improve diagnostic specificity, and prognosticating pancreatitis that progresses to pancreatic cancer would also improve diagnoses of pancreas pathology. The high glycolytic metabolism of pancreatic cancer can cause tumor acidosis, and different levels of pancreatitis may also have different levels of acidosis, so that extracellular acidosis may be a diagnostic biomarker for these pathologies. AcidoCEST MRI can noninvasively measure extracellular pH (pHe) in the pancreas and pancreatic tissue. We used acidoCEST MRI to measure pHe in a KC model treated with caerulein, which causes pancreatitis followed by development of pancreatic cancer. We also evaluated the KC model treated with PBS, and wild-type mice treated with caerulein or PBS as controls. The caerulein-treated KC cohort had lower pHe of 6.85-6.92 before and during the first 48 h after initiating treatment, relative to a pHe of 6.92 to 7.05 pHe units for the other cohorts. The pHe of the caerulein-treated KC cohort decreased to 6.79 units at 5 weeks when pancreatic tumors were detected with anatomical MRI, and sustained a pHe of 6.75 units at the 8-week time point. Histopathology was used to evaluate and validate the presence of tumors and inflammation in each cohort. These results showed that acidoCEST MRI can differentiate pancreatic cancer from pancreatitis in this mouse model, but does not appear to differentiate pancreatitis that progresses to pancreatic cancer vs. pancreatitis that does not progress to cancer.


Assuntos
Acidose/metabolismo , Imageamento por Ressonância Magnética , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/metabolismo , Pancreatite/diagnóstico , Pancreatite/metabolismo , Animais , Biomarcadores , Meios de Contraste/administração & dosagem , Meios de Contraste/química , Diagnóstico Diferencial , Modelos Animais de Doenças , Espaço Extracelular/metabolismo , Feminino , Imuno-Histoquímica , Ácido Iotalâmico/administração & dosagem , Ácido Iotalâmico/química , Imageamento por Ressonância Magnética/métodos , Masculino , Camundongos
2.
Magn Reson Med ; 79(5): 2766-2772, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29024066

RESUMO

PURPOSE: Extracellular pH (pHe) is an important biomarker for cancer cell metabolism. Acido-chemical exchange saturation transfer (CEST) MRI uses the contrast agent iopamidol to create spatial maps of pHe. Measurements of amide proton transfer exchange rates (kex ) from endogenous CEST MRI were compared to pHe measurements by exogenous acido-CEST MRI to determine whether endogenous kex could be used as a proxy for pHe measurements. METHODS: Spatial maps of pHe and kex were obtained using exogenous acidoCEST MRI and an endogenous CEST MRI analyzed with the omega plot method, respectively, to evaluate mouse kidney, a flank tumor model, and a spontaneous lung tumor model. The pHe and kex results were evaluated using pixelwise comparisons. RESULTS: The kex values obtained from endogenous CEST measurements did not correlate with the pHe results from exogenous CEST measurements. The kex measurements were limited to fewer pixels and had a limited dynamic range relative to pHe measurements. CONCLUSION: Measurements of kex with endogenous CEST MRI cannot substitute for pHe measurements with acidoCEST MRI. Whereas endogenous CEST MRI may still have good utility for evaluating some specific pathologies, exogenous acido-CEST MRI is more appropriate when evaluating pathologies based on pHe values. Magn Reson Med 79:2766-2772, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Acidose/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico por imagem , Animais , Feminino , Concentração de Íons de Hidrogênio , Iopamidol/farmacocinética , Rim/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Camundongos , Camundongos Nus
3.
Mol Imaging Biol ; 20(2): 240-248, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28726131

RESUMO

PURPOSE: The detection of enzyme activities and evaluation of enzyme inhibitors have been challenging with magnetic resonance imaging (MRI). To address this need, we have developed a diamagnetic, nonmetallic contrast agent and a protocol known as catalyCEST MRI that uses chemical exchange saturation transfer (CEST) to detect enzyme activity as well as enzyme inhibition. PROCEDURES: We synthesized a diamagnetic MRI contrast agent that has enzyme responsive and enzyme unresponsive CEST signals. We tested the ability of this agent to detect the activity of kallikrein 6 (KLK6) in biochemical solutions, in vitro and in vivo, with and without a KLK6 inhibitor. RESULTS: The agent detected KLK6 activity in solution and also detected KLK6 inhibition by antithrombin III. KLK6 activity was detected during in vitro studies with HCT116 colon cancer cells, relative to the detection of almost no activity in a KLK6-knockdown HCT116 cell line and HCT116 cells treated with antithrombin III inhibitor. Finally, strong enzyme activity was detected within an in vivo HCT116 tumor model, while lower enzyme activity was detected in a KLK6 knockdown tumor model and in the HCT116 tumor model treated with antithrombin III inhibitor. In all cases, comparisons of the enzyme responsive and enzyme unresponsive CEST signals were critical for the detection of enzyme activity. CONCLUSIONS: This study has established that catalyCEST MRI with an exogenous diaCEST agent can evaluate enzyme activity and inhibition in solution, in vitro and in vivo.


Assuntos
Inibidores Enzimáticos/farmacologia , Calicreínas/antagonistas & inibidores , Calicreínas/metabolismo , Imageamento por Ressonância Magnética , Células HCT116 , Humanos , Soluções
4.
Tomography ; 3(4): 201-210, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29479563

RESUMO

Performing chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) in lung tissue is difficult because of motion artifacts. We, therefore, developed a CEST MRI acquisition and analysis method that performs retrospective respiration gating. Our method used an acquisition scheme with a short 200-millisecond saturation pulse that can accommodate the timing of the breathing cycle, and with saturation applied at frequencies in 0.03-ppm intervals. The Fourier transform of each image was used to calculate the difference in phase angle between adjacent pixels in the longitudinal direction of the respiratory motion. Additional digital filtering techniques were used to evaluate the breathing cycle, which was used to construct CEST spectra from images during quiescent periods. Results from CEST MRI with and without respiration gating analysis were used to evaluate the asymmetry of the magnetization transfer ratio (MTRasym), a measure of CEST, for an egg white phantom that underwent cyclic motion, in the liver of healthy patients, as well as liver and tumor tissues of patients diagnosed with lung cancer. Retrospective respiration gating analysis produced more precise measurements in all cases with significant motion compared with nongated analysis methods. Finally, a preliminary clinical study with the same respiration-gated CEST MRI method showed a large increase in MTRasym after radiation therapy, a small increase or decrease in MTRasym after chemotherapy, and mixed results with combined chemoradiation therapy. Therefore, our retrospective respiration-gated method can improve CEST MRI evaluations of tumors and organs that are affected by respiratory motion.

5.
Mol Imaging Biol ; 19(4): 617-625, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-27896628

RESUMO

PURPOSE: We optimized acido-chemical exchange saturation transfer (acidoCEST) magnetic resonance imaging (MRI), a method that measures extracellular pH (pHe), and translated this method to the radiology clinic to evaluate tumor acidosis. PROCEDURES: A CEST-FISP MRI protocol was used to image a flank SKOV3 tumor model. Bloch fitting modified to include the direct estimation of pH was developed to generate parametric maps of tumor pHe in the SKOV3 tumor model, a patient with high-grade invasive ductal carcinoma, and a patient with metastatic ovarian cancer. The acidoCEST MRI results of the patient with metastatic ovarian cancer were compared with DCE MRI and histopathology. RESULTS: The pHe maps of a flank model showed pHe measurements between 6.4 and 7.4, which matched with the expected tumor pHe range from past acidoCEST MRI studies in flank tumors. In the patient with metastatic ovarian cancer, the average pHe value of three adjacent tumors was 6.58, and the most reliable pHe measurements were obtained from the right posterior tumor, which favorably compared with DCE MRI and histopathological results. The average pHe of the kidney showed an average pHe of 6.73 units. The patient with high-grade invasive ductal carcinoma failed to accumulate sufficient agent to generate pHe measurements. CONCLUSIONS: Optimized acidoCEST MRI generated pHe measurements in a flank tumor model and could be translated to the clinic to assess a patient with metastatic ovarian cancer.


Assuntos
Acidose/diagnóstico por imagem , Imageamento por Ressonância Magnética , Pesquisa Translacional Biomédica , Acidose/patologia , Animais , Carcinoma Epitelial do Ovário , Linhagem Celular Tumoral , Simulação por Computador , Modelos Animais de Doenças , Humanos , Camundongos , Metástase Neoplásica , Neoplasias Epiteliais e Glandulares/patologia , Neoplasias Ovarianas/patologia
6.
Magn Reson Med ; 77(5): 2005-2014, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27221386

RESUMO

PURPOSE: We proposed to detect the in vivo enzyme activity of γ-glutamyl transferase (GGT) within mouse models of human ovarian cancers using catalyCEST MRI with a diamagnetic CEST agent. METHODS: A CEST-FISP MRI protocol and a diamagnetic CEST agent were developed to detect GGT enzyme activity in biochemical solution. A quantitative Michaelis-Menten enzyme kinetics study was performed to confirm that catalyCEST MRI can measure enzyme activity. In vivo catalyCEST MRI studies generated pixel-wise activity maps of GGT activities. Ex vivo fluorescence imaging was performed for validation. RESULTS: CatalyCEST MRI selectively detected two CEST signals from a single CEST agent, whereby one CEST signal was responsive to GGT enzyme activity and the other CEST signal was an unresponsive control signal. The comparison of these CEST signals facilitated in vivo catalyCEST MRI studies that detected high GGT activity in OVCAR-8 tumors, low GGT activity in OVCAR-3 tumors, and low or no GGT activity in muscle tissues. CONCLUSION: CatalyCEST MRI with a diamagnetic CEST agent can detect the level of GGT enzyme activity within in vivo tumor models of human ovarian cancers. Magn Reson Med 77:2005-2014, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias Ovarianas/diagnóstico por imagem , Animais , Catálise , Linhagem Celular Tumoral , Meios de Contraste/química , Cisteína/química , Modelos Animais de Doenças , Feminino , Corantes Fluorescentes/química , Glicina/química , Humanos , Concentração de Íons de Hidrogênio , Processamento de Imagem Assistida por Computador , Cinética , Camundongos , Camundongos Nus , Transplante de Neoplasias , Neoplasias Ovarianas/patologia , Peptídeos/química , gama-Glutamiltransferase/metabolismo
7.
Magn Reson Med ; 78(1): 97-106, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-27465207

RESUMO

PURPOSE: Multislice maps of extracellular pH (pHe) are needed to interrogate the heterogeneities of tumors and normal organs. To address this need, we have developed a multislice chemical exchange saturation transfer (CEST) MRI acquisition method with a CEST spectrum-fitting method that measures in vivo pHe over a range of 6.3 to 7.4. METHODS: The phase offset multiplanar (POMP) method was adapted for CEST fast imaging with steady-state free precession (FISP) MRI to acquire multiple image slices with a single CEST saturation pulse. The Bloch-McConnell equations were modified to include pH based on a calibration of pH and chemical exchange rate for the contrast agent iopamidol. These equations were used to estimate the pixel-wise pHe values throughout the multislice acidoCEST MR images of the tumor, kidney, bladder, and other tissues of a MDA-MB-231 tumor model. RESULTS: Multislice acidoCEST MRI successfully mapped a gradient of pHe from 6.73 to 6.81 units from the tumor core to rim, and also mapped a gradient of pHe 6.56 to 6.97 across the mouse kidney. The bladder was found to be pHe 6.3. CONCLUSION: AcidoCEST MRI with POMP acquisition and Bloch-McConnel analysis can map pHe in multiple imaging slices through the tumor, kidney, and bladder. This multislice evaluation facilitates assessments of spatial heterogeneity of tissue pHe. Magn Reson Med 78:97-106, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Concentração de Íons de Hidrogênio , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias Experimentais/química , Neoplasias Experimentais/diagnóstico por imagem , Espectroscopia de Prótons por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Animais , Feminino , Camundongos , Camundongos Nus , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise Espaço-Temporal
8.
J Magn Reson ; 270: 56-70, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27404128

RESUMO

QUantification of Exchange as a function of Saturation Power On the Water Resonance (QUESPOWR) MRI is a new method that can estimate chemical exchange rates. This method acquires a series of OPARACHEE MRI acquisitions with a range of RF powers for the WALTZ16(∗) pulse train, which are applied on the water resonance. A QUESPOWR plot can be generated from the power dependence of the % water signal, which is similar to a QUESP plot that is generated from CEST MRI acquisition methods with RF saturation applied off-resonance from water. A QUESPOWR plot can be quantitatively analyzed using linear fitting methods to provide estimates of average chemical exchange rates. Analyses of the shapes of QUESPOWR plots can also be used to estimate relative differences in average chemical exchange rates and concentrations of biomolecules. The performance of QUESPOWR MRI was assessed via simulations, an in vitro study with iopamidol, and an in vivo study with a mouse model of mammary carcinoma. The results showed that QUESPOWR MRI is especially sensitive to chemical exchange between water and biomolecules that have intermediate to fast chemical exchange rates and chemical shifts that are close to water, which are notoriously difficult to assess with other CEST MRI methods. In addition, in vivo QUESPOWR MRI detected acidic tumor tissues relative to normal tissues that are pH-neutral, and therefore may be a new paradigm for tumor detection with MRI.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética , Neoplasias Experimentais/diagnóstico por imagem , Água , Animais , Meios de Contraste , Concentração de Íons de Hidrogênio , Interpretação de Imagem Assistida por Computador , Camundongos , Imagens de Fantasmas
9.
Proc SPIE Int Soc Opt Eng ; 97882016 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-27212783

RESUMO

We have developed a MRI method that can measure extracellular pH in tumor tissues, known as acidoCEST MRI. This method relies on the detection of Chemical Exchange Saturation Transfer (CEST) of iopamidol, an FDA-approved CT contrast agent that has two CEST signals. A log10 ratio of the two CEST signals is linearly correlated with pH, but independent of agent concentration, endogenous T1 relaxation time, and B1 inhomogeneity. Therefore, detecting both CEST effects of iopamidol during in vivo studies can be used to accurately measure the extracellular pH in tumor tissues. Past in vivo studies using acidoCEST MRI have suffered from respiration artifacts in orthotopic and lung tumor models that have corrupted pH measurements. In addition, the non-linear fitting method used to analyze results is unreliable as it is subject to over-fitting especially with noisy CEST spectra. To improve the technique, we have recently developed a respiration gated CEST MRI pulse sequence that has greatly reduced motion artifacts, and we have included both a prescan and post scan to remove endogenous CEST effects. In addition, we fit the results by parameterizing the contrast of the exogenous agent with respect to pH via the Bloch equations modified for chemical exchange, which is less subject to over-fitting than the non-linear method. These advances in the acidoCEST MRI technique and analysis methods have made pH measurements more reliable, especially in areas of the body subject to respiratory motion.

10.
Contrast Media Mol Imaging ; 10(6): 446-55, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26108564

RESUMO

Acidosis within tumor and kidney tissues has previously been quantitatively measured using a molecular imaging technique known as acidoCEST MRI. The previous studies used iopromide and iopamidol, two iodinated contrast agents that are approved for clinical CT diagnoses and have been repurposed for acidoCEST MRI studies. We aimed to compare the performance of the two agents for measuring pH by optimizing image acquisition conditions, correlating pH with a ratio of CEST effects from an agent, and evaluating the effects of concentration, endogenous T1 relaxation time and temperature on the pH-CEST ratio correlation for each agent. These results showed that the two agents had similar performance characteristics, although iopromide produced a pH measurement with a higher dynamic range while iopamidol produced a more precise pH measurement. We then compared the performance of the two agents to measure in vivo extracellular pH (pHe) within xenograft tumor models of Raji lymphoma and MCF-7 breast cancer. Our results showed that the pHe values measured with each agent were not significantly different. Also, iopromide consistently measured a greater region of the tumor relative to iopamidol in both tumor models. Therefore, an iodinated contrast agent for acidoCEST MRI should be selected based on the measurement properties needed for a specific biomedical study and the pharmacokinetic properties of a specific tumor model.


Assuntos
Meios de Contraste/química , Iohexol/análogos & derivados , Iopamidol/química , Imageamento por Ressonância Magnética/métodos , Microambiente Tumoral/fisiologia , Acidose/patologia , Animais , Calibragem , Linhagem Celular Tumoral , Resistencia a Medicamentos Antineoplásicos/fisiologia , Líquido Extracelular/química , Feminino , Humanos , Concentração de Íons de Hidrogênio , Iohexol/química , Rim/patologia , Células MCF-7 , Camundongos , Camundongos SCID , Imagem Molecular , Transplante de Neoplasias , Neoplasias/patologia , Transplante Heterólogo
11.
Mol Imaging Biol ; 17(4): 488-96, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25622809

RESUMO

PURPOSE: We aimed to develop pixelwise maps of tumor acidosis to aid in evaluating extracellular tumor pH (pHe) in cancer biology. PROCEDURES: MCF-7 and MDA-MB-231 mouse models were imaged during a longitudinal study. AcidoCEST MRI and a series of image processing methods were used to produce parametric maps of tumor pHe, and tumor pHe was also measured with a pH microsensor. RESULTS: Sufficient contrast-to-noise for producing pHe maps was achieved by using standard image processing methods. A comparison of pHe values measured with acidoCEST MRI and a pH microsensor showed that acidoCEST MRI measured tumor pHe with an accuracy of 0.034 pH units. The MCF-7 tumor model was found to be more acidic compared to the MDA-MB-231 tumor model. The pHe was not related to tumor size during the longitudinal study. CONCLUSIONS: These results show that acidoCEST MRI can create pixelwise tumor pHe maps of mouse models of cancer.


Assuntos
Acidose/patologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagem Molecular/métodos , Neoplasias Experimentais/química , Neoplasias Experimentais/patologia , Animais , Linhagem Celular Tumoral , Feminino , Humanos , Concentração de Íons de Hidrogênio , Camundongos , Camundongos SCID
12.
Mol Imaging Biol ; 17(2): 177-84, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25187227

RESUMO

PURPOSE: A feed-forward loop involving lactic acid production may potentially occur during the formation of idiopathic pulmonary fibrosis. To provide evidence for this feed-forward loop, we used acidoCEST MRI to measure the extracellular pH (pHe), while also measuring percent uptake of the contrast agent, lesion size, and the apparent diffusion coefficient (ADC). PROCEDURES: We developed a respiration-gated version of acidoCEST MRI to improve the measurement of pHe and percent uptake in lesions. We also used T2-weighted MRI to measure lesion volumes and diffusion-weighted MRI to measure ADC. RESULTS: The longitudinal changes in average pHe and % uptake of the contrast agent were inversely related to reduction in lung lesion volume. The average ADC did not change during the time frame of the study. CONCLUSIONS: The increase in pHe during the reduction in lesion volume indicates a role for lactic acid in the proposed feed-forward loop of IPF.


Assuntos
Espaço Extracelular/química , Fibrose Pulmonar Idiopática/metabolismo , Imageamento por Ressonância Magnética/métodos , Animais , Colágeno/metabolismo , Simulação por Computador , Modelos Animais de Doenças , Concentração de Íons de Hidrogênio , Iopamidol/química , Iopamidol/farmacologia , Pulmão/patologia , Masculino , Camundongos Endogâmicos C57BL , Respiração
13.
J Am Chem Soc ; 135(17): 6396-8, 2013 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-23601132

RESUMO

CatalyCEST MRI can detect enzyme activity by employing contrast agents that are detected through chemical exchange saturation transfer (CEST). A CEST agent, Tm-DO3A-cadaverine, has been designed to detect the catalytic activity of transglutaminase (TGase), which creates a covalent bond between the agent and the side chain of a glutamine amino acid residue. CEST appeared at -9.2 ppm after TGase conjugated Tm-DO3A-cadaverine to albumin, which also caused a decrease in CEST from albumin at +4.6 ppm. Studies with model peptides revealed similar appearances and decreases in detectable CEST effects following TGase-catalyzed conjugation of the contrast agent and peptide. The MR frequencies and amplitudes of these CEST effects were dependent on the peptide sequence, which demonstrated the sensitivity of CEST agents to ligand conformations that may be exploited to create more responsive molecular imaging agents. The chemical exchange rates of the substrates and conjugated products were measured by fitting modified Bloch equations to CEST spectra, which demonstrated that changes in exchange rates can also be used to detect the formation of a covalent bond by catalyCEST MRI.


Assuntos
Meios de Contraste/química , Imageamento por Ressonância Magnética/métodos , Albuminas/química , Amidas/química , Cadaverina/química , Catálise , Glutamina/química , Conformação Molecular , Peptídeos/síntese química , Peptídeos/química , Prótons , Transglutaminases/química , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA