Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ann Card Anaesth ; 26(1): 78-82, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36722592

RESUMO

Concomitant mitral and aortic valve stenosis in a patient with mitral annular calcification and porcelain aorta poses a unique problem to the surgical team. Transcatheter aortic and mitral valve replacements in native valves offer a viable option for such selected group of patients. We present the case of a 54-year-old male who presented with severe aortic stenosis (AS) and severe mitral stenosis (MS) but was deemed high risk for surgery owing to intense calcification of the aorta and mitral annular calcification, and successfully underwent transcatheter double native valve replacement.


Assuntos
Estenose da Valva Aórtica , Calcinose , Procedimentos Cirúrgicos Cardíacos , Estenose da Valva Mitral , Masculino , Humanos , Pessoa de Meia-Idade , Estenose da Valva Mitral/complicações , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Calcinose/complicações , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia
2.
Future Cardiol ; 17(1): 73-80, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32628046

RESUMO

The transcatheter aortic valve replacement (TAVR) is an established treatment for patients with severe symptomatic aortic stenosis (AS) at prohibitive risk for surgery. It is an alternative treatment to surgical aortic valve replacement in patients with AS at intermediate- and high-surgical risk. Although regulatory authorities extend the indications of TAVR to treat patients at low-surgical risk, the limitations of earlier-generation transcatheter heart valve (THV) systems accelerate the development of improved newer generation of THV systems. Myval™ THV (Meril Life Sciences Pvt. Ltd., Vapi, Gujarat, India) is a newer-generation, balloon-expandable TAVR system with features that facilitate accurate positioning of the bioprosthetic valve and favorable procedural and clinical outcomes. This review summarizes existing preclinical and clinical data on Myval THV for the intervention of symptomatic native AS and lays out the plan for future research program.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
3.
Ann Thorac Surg ; 103(5): 1399-1405, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27765175

RESUMO

BACKGROUND: Smaller transcatheter aortic valve replacement (TAVR) delivery systems have increased the number of patients eligible for transfemoral procedures while decreasing the need for transaortic (TAo) or transapical (TA) access. As a result, newer TAVR centers are likely to have less exposure to these alternative access techniques, making it harder to achieve proficiency. The purpose of this study was to evaluate the learning curve for TAVR approaches and compare perioperative outcomes. METHODS: From January 2008 to December 2014, 400 patients underwent TAVR (transfemoral, n = 179; TA, n = 120; and TAo, n = 101)). Learning curves were constructed using metrics of contrast utilization, procedural, and fluoroscopy times. Outcomes during the learning curve were compared with after proficiency was achieved. RESULTS: Depending on the metric, learning curves for all three routes differed slightly but all demonstrated proficiency by the 50th case. There were no significant differences in procedural times whereas improvements in contrast use were most notable for TA (69 ± 40 mL versus 50 ± 23 mL, p = 0.002). For both TA and TAo, fewer patients received transfusions once proficiency was reached (62% versus 34%, p = 0.003, and 42% versus 14%, p = 0.002, respectively). No differences in 30-day or 1-year mortality were seen before or after proficiency was reached for any approach. CONCLUSIONS: The learning curves for TA and TAo are distinct but technical proficiency begins to develop by 25 cases and becomes complete by 50 cases for both approaches. Given the relatively low volume of alternative access, achieving technical proficiency may take significant time. However, technical proficiency had no effect on 30-day or 1-year mortality for any access approach.


Assuntos
Institutos de Cardiologia , Curva de Aprendizado , Substituição da Valva Aórtica Transcateter/educação , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Competência Clínica , Meios de Contraste/administração & dosagem , Feminino , Necessidades e Demandas de Serviços de Saúde , Humanos , Comunicação Interdisciplinar , Colaboração Intersetorial , Estimativa de Kaplan-Meier , Masculino , Duração da Cirurgia , Seleção de Pacientes , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA