Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Cardiovasc Revasc Med ; 34: 128-133, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33526391

RESUMO

BACKGROUND/PURPOSE: Patients with a functional single ventricle undergo multiple, palliative open-heart surgeries. This includes a superior cavopulmonary anastomosis or bidirectional Glenn shunt. A less-invasive transcatheter approach may reduce morbidity. METHODS/MATERIALS: We analyzed pre-Glenn X-ray contrast angiography (XA), cardiac computed tomography (CT), and cardiac magnetic resonance (CMR) studies. RESULTS: Over an eleven-year period (1/2007 - 6/2017), 139 Glenn surgeries were performed at our institution. The typical age range at surgery was 59 - 371 days (median = 163; IQR = 138 - 203). Eight-nine XA, ten CT, and ten CMR studies obtained from these patients were analyzed. Cephalad SVC measurements (millimeters) were 7.3 ± 1.7 (XA), 7.7 ± 1.6 (CT) and 6.9 ± 1.8 (CMR). RPA measurements were 7.3 ± 1.9 (XA), 7.4 ± 1.6 (CT) and 6.6 ± 1.9 (CMR). Potential device lengths were 10.9 ± 6 - 17.4 ± 6.4 (XA), 10.1 ± 2.1 - 17.7 ± 2.4 (CT) and 17.3 ± 4. - 23.7 ± 5.5 (CMR). SVC-RPA angle (degrees) was 132.9 ± 13.2 (CT) and 140 ± 10.2 (MRI). Image quality of all CT (100%), almost all XA (SVC 100%, RPA 99%), and most MRI (SVC 80%, RPA 90%) were deemed sufficient. Parametric modeling virtual fit device with 10 mm diameter and 20 - 25 mm length was ideal. CONCLUSIONS: Ideal transcatheter cavopulmonary shunt device for the typical patient would be 10 mm in diameter and 20-25 mm in length.


Assuntos
Técnica de Fontan , Derivação Cardíaca Direita , Cardiopatias Congênitas , Técnica de Fontan/efeitos adversos , Técnica de Fontan/métodos , Derivação Cardíaca Direita/efeitos adversos , Derivação Cardíaca Direita/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Imagem Multimodal , Artéria Pulmonar , Estudos Retrospectivos
2.
J Invasive Cardiol ; 33(12): E954-E959, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34792481

RESUMO

OBJECTIVES: We report a multicenter experience with simultaneous right ventricular outflow tract (RVOT) stenting and transcatheter pulmonary valve implantation using the Melody valve (Medtronic). BACKGROUND: Prestenting the RVOT before Melody valve implantation is now the standard of care. Prestenting is usually performed as a separate step. The "one-step" technique for simultaneous landing zone stenting and Melody delivery was previously reported using only Max LD stents (Medtronic). We report a multicenter experience of simultaneous stenting and Melody implantation using multiple stent types in combination. METHODS: This retrospective cohort study includes 33 patients from 3 centers who underwent simultaneous stenting and Melody valve implantation between 2017 and 2020. Key variables were compared with 31 patients from the same centers who underwent standard (non-simultaneous) prestenting followed by Melody implantation during the same time frame. RESULTS: The 2 groups were similar in terms of age, weight, sex, and total procedure time. The 2 groups had similar clinical results and safety profiles, with no difference between the postimplantation right ventricle (RV) to pulmonary artery systolic pressure gradient, RV to aortic pressure ratio, and complication rate. The simultaneous group had lower radiation exposure as measured by dose area product. Up to 3 stents were safely placed simultaneously with a Melody valve. CONCLUSIONS: Simultaneous RVOT stenting and Melody valve implantation can safely be used to place up to 3 stents outside a Melody valve. This approach can simplify the catheterization procedure and potentially reduce radiation dose.


Assuntos
Valva Pulmonar , Catéteres , Ventrículos do Coração , Humanos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Estudos Retrospectivos , Stents
3.
Int J Pediatr Otorhinolaryngol ; 145: 110703, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33910043

RESUMO

OBJECTIVES: To report the first use of a balloon expandable bare metal stent for treating infant bronchomalacia. BACKGROUND: Infant bronchomalacia often requires prolonged mechanical ventilation and can be life-threatening. Effective treatment for severe infant bronchomalacia continues to be elusive. We present three cases of bronchial stenting for no-option or treatment refractory infant bronchomalacia. METHODS: Three consecutive cases of stenting to relieve conservative treatment refractory severe infant bronchomalacia were performed between February 2019 and December 2020. Initial diagnosis was confirmed with Computed Tomography (CT) angiography. Patients underwent rigid micro laryngoscopy, bronchoscopy, and flexible bronchoscopy to evaluate the airway. Initial conservative management strategies were pursued. Patients failing initial conservative management strategies were considered for rescue bronchial stenting. RESULTS: Our initial clinical experience with a coronary bare metal stent for these procedures has been favorable. The stent was easy to deploy with precision. We did not encounter stent embolization or migration. There was sufficient stent radial strength to relieve bronchomalacia without causing restenosis or erosion. There was no significant granulation tissue formation. In one patient, the stent was removed after 12 months of somatic growth; this was uneventful and bronchial patency was maintained. There were no complications in any of our patients regarding stent placement and reliability. CONCLUSION: In cases of three infants with severe bronchomalacia, we found that bronchial stenting with the bare metal coronary stent was effective in relieving bronchial stenosis.


Assuntos
Broncopatias , Broncomalácia , Brônquios/cirurgia , Broncopatias/diagnóstico , Broncopatias/etiologia , Broncopatias/cirurgia , Broncomalácia/diagnóstico , Broncomalácia/etiologia , Broncomalácia/cirurgia , Broncoscopia , Humanos , Lactente , Reprodutibilidade dos Testes , Stents
5.
Semin Thorac Cardiovasc Surg ; 33(3): 816-823, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33662555

RESUMO

This hemodynamic feasibility study examined total cavopulmonary connection (TCPC) designs connecting the extracardiac conduit to the anterior surface of pulmonary arteries (PAs) or superior vena cava (SVC) rather than to the inferior PA surface (traditional TCPC). The study involved twenty-five consecutive Fontan patients meeting inclusion criteria from a single institution. A virtual surgical platform mimicked the completed traditional TCPC and generated three anterior anastomosis designs: Anterior-PA, Middle-SVC, and SVC-Inn (Inn: innominate vein). Hemodynamic performance of anterior anastomosis designs was compared with the traditional TCPC regarding indexed power loss (iPL) and hepatic flow distribution (HFD). Compared to the traditional TCPC, the Anterior-PA design produces a similar iPL. The Middle-SVC design is also similar, though the iPL difference is positively correlated with the anastomosing height. The SVC-Inn design had significantly more iPL. The three anterior anastomosis designs did not have a significant difference in HFD (from traditional TCPC). Pulmonary flow distribution (PFD) has a stronger correlation with HFD from the anterior anastomosis designs than the traditional TCPC. This hemodynamic feasibility study examined anterior anastomosis, extracardiac TCPC designs that may offer surgeons clinical dexterity. The Anterior-PA design may be equivalent to the traditional TCPC. Fontan extracardiac conduit anastomosis just superior to the PAs (Middle-SVC) also preserves hemodynamic performance and avoids direct PA anastomosis. These designs could simplify surgical Fontan completion, and may particularly benefit patients requiring surgical dissection, having atypical PA orientation, or after PA stent angioplasty.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/cirurgia , Hemodinâmica , Humanos , Pulmão , Artéria Pulmonar/cirurgia , Veia Cava Superior/cirurgia
6.
World J Pediatr Congenit Heart Surg ; 11(5): 643-645, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32853069

RESUMO

A 15-year-old presented in cardiogenic shock secondary to viral myocarditis requiring venoarterial extracorporeal membrane oxygenation (ECMO) support. He developed large thrombi of the left ventricle and aortic root. Anticoagulation was increased, and medications were initiated to decrease the likelihood of aortic valve opening. He underwent balloon atrial septostomy followed by placement of a left atrial vent. A pigtail catheter was placed in the ascending aorta for direct heparin infusion. Serial echocardiograms showed progressive resolution of the thrombi. He was successfully weaned from ECMO and discharged home without neurological deficits.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Gerenciamento Clínico , Oxigenação por Membrana Extracorpórea/métodos , Trombose/terapia , Adolescente , Ecocardiografia , Átrios do Coração , Ventrículos do Coração , Humanos , Masculino , Guias de Prática Clínica como Assunto
7.
Pediatr Cardiol ; 41(3): 503-513, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32198594

RESUMO

In recent years, interventional cardiac magnetic resonance imaging (iCMR) has evolved from attractive theory to clinical routine at several centers. Real-time cardiac magnetic resonance imaging (CMR fluoroscopy) adds value by combining soft-tissue visualization, concurrent hemodynamic measurement, and freedom from radiation. Clinical iCMR applications are expanding because of advances in catheter devices and imaging. In the near future, iCMR promises novel procedures otherwise unsafe under standalone X-Ray guidance.


Assuntos
Cateterismo Cardíaco/métodos , Imagem por Ressonância Magnética Intervencionista/instrumentação , Fluoroscopia/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos
8.
J Am Coll Cardiol ; 75(12): 1455-1470, 2020 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-32216915

RESUMO

Transcatheter electrosurgery refers to a family of procedures using radiofrequency energy to vaporize and traverse or lacerate tissue despite flowing blood. The authors review theory, simulations, and benchtop demonstrations of how guidewires, insulation, adjunctive catheters, and dielectric medium interact. For tissue traversal, all but the tip of traversing guidewires is insulated to concentrate current. For leaflet laceration, the "Flying V" configuration concentrates current at the inner lacerating surface of a kinked guidewire. Flooding the field with non-ionic dextrose eliminates alternative current paths. Clinical applications include traversing occlusions (pulmonary atresia, arterial and venous occlusion, and iatrogenic graft occlusion), traversing tissue planes (atrial and ventricular septal puncture, radiofrequency valve repair, transcaval access, Potts and Glenn shunts), and leaflet laceration (BASILICA, LAMPOON, ELASTA-Clip, and others). Tips are provided for optimizing these techniques. Transcatheter electrosurgery already enables a range of novel therapeutic procedures for structural heart disease, and represents a promising advance toward transcatheter surgery.


Assuntos
Eletrocirurgia/métodos , Implante de Prótese de Valva Cardíaca/métodos , Desenho de Prótese/métodos , Substituição da Valva Aórtica Transcateter/métodos , Cardiologia/métodos , Cardiologia/tendências , Eletrocirurgia/tendências , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/tendências , Humanos , Desenho de Prótese/tendências , Literatura de Revisão como Assunto , Substituição da Valva Aórtica Transcateter/tendências
9.
World J Pediatr Congenit Heart Surg ; 10(3): 330-337, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31084312

RESUMO

BACKGROUND: Patients with heterotaxy, single ventricle and interrupted inferior vena cava are at risk of developing significant pulmonary arteriovenous malformations and cyanosis, and inequitable distribution of hepatic factor has been implicated in their development. We describe our experience with a technique for hepatic vein incorporation that reliably provides resolution of cyanosis and presumably equitable hepatic factor distribution. METHODS: A retrospective review of a single-surgeon experience was conducted for patients who underwent this modified Fontan operation utilizing an extracardiac conduit from the hepatic veins to the dominant superior cavopulmonary connection. Preoperative characteristics and imaging, operative details, and postoperative course and imaging were abstracted. RESULTS: Median age at operation was 5 years (2-10 years) and median weight was 19.6 kg (11.8-23 kg). Sixty percent (3/5) of patients had Fontan completion without cardiopulmonary bypass, and follow-up was complete at a median of 14 months (range 1-20 months). Systemic saturations increased significantly from 81% ± 1.9% preoperatively to 95% ± 3.5% postoperatively, P = .0008. Median length of stay was 10 days (range: 7-14 days). No deaths occurred. One patient required reoperation for bleeding and one was readmitted for pleural effusion. Postoperative imaging suggested distribution of hepatic factor to all lung segments with improved pulmonary arteriovenous malformation burden. CONCLUSIONS: Hepatic vein incorporation for patients with heterotaxy and interrupted inferior vena cava should optimally provide equitable pulmonary distribution of hepatic factor with resolution of cyanosis. The described technique is performed through a conventional approach, is facile, and improves cyanosis in these complex patients.


Assuntos
Anormalidades Múltiplas , Malformações Arteriovenosas/cirurgia , Veia Ázigos/cirurgia , Técnica de Fontan/métodos , Veias Hepáticas/cirurgia , Síndrome de Heterotaxia/cirurgia , Veia Cava Inferior/cirurgia , Veia Ázigos/anormalidades , Criança , Pré-Escolar , Feminino , Veias Hepáticas/anormalidades , Humanos , Masculino , Estudos Retrospectivos , Veia Cava Inferior/anormalidades
10.
Congenit Heart Dis ; 14(2): 288-296, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30620141

RESUMO

BACKGROUND: In the modern era, results of the arterial switch operation (ASO) for transposition of the great arteries are excellent. However, because of the LeCompte maneuver, there may be a propensity for development of pulmonary artery stenosis. We encountered atypical complications of pulmonary artery stenting in patients after the ASO, including aorto-pulmonary fistula and coronary compression. METHODS: We performed a 10-year retrospective review of catheterizations performed in patients after ASO in our institution with a focus on adverse events. RESULTS: Diagnostic and interventional catheterizations were performed in 47 patients. In 29 patients, 37 interventional procedures performed, which included pulmonary artery angioplasty and/or stenting. In this group, there were five major adverse events (14%), including three aorto-pulmonary fistulae and one coronary artery compression among patients having stent implantation or stent redilation. In addition, there were 6/37 (16%) intended stent procedures, which were aborted because there appeared to be high-risk of significant adverse events. CONCLUSIONS: This review suggests that percutaneous intervention on pulmonary artery stenosis after ASO has high-risk and should be undertaken advisedly. Prior thorough evaluation of coronary arteries is mandatory as coronary reimplantation sites may be adjacent to sites of pulmonary artery stenosis. Furthermore, if pulmonary artery stent implantation or stent redilation is contemplated, the risk of stent fracture and possible AP fistula should be recognized. Primary use of reinforced covered stents should be considered.


Assuntos
Transposição das Grandes Artérias/efeitos adversos , Complicações Pós-Operatórias , Artéria Pulmonar/cirurgia , Estenose de Artéria Pulmonar/cirurgia , Stents , Transposição dos Grandes Vasos/cirurgia , Procedimentos Cirúrgicos Vasculares/métodos , Adolescente , Angiografia , Cateterismo Cardíaco , Feminino , Humanos , Masculino , Artéria Pulmonar/diagnóstico por imagem , Reoperação , Estudos Retrospectivos , Estenose de Artéria Pulmonar/diagnóstico , Estenose de Artéria Pulmonar/etiologia , Transposição dos Grandes Vasos/diagnóstico , Resultado do Tratamento , Adulto Jovem
11.
J Cardiovasc Magn Reson ; 19(1): 65, 2017 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-28874164

RESUMO

BACKGROUND: Children with heart disease may require repeated X-Ray cardiac catheterization procedures, are more radiosensitive, and more likely to survive to experience oncologic risks of medical radiation. Cardiovascular magnetic resonance (CMR) is radiation-free and offers information about structure, function, and perfusion but not hemodynamics. We intend to perform complete radiation-free diagnostic right heart catheterization entirely using CMR fluoroscopy guidance in an unselected cohort of pediatric patients; we report the feasibility and safety. METHODS: We performed 50 CMR fluoroscopy guided comprehensive transfemoral right heart catheterizations in 39 pediatric (12.7 ± 4.7 years) subjects referred for clinically indicated cardiac catheterization. CMR guided catheterizations were assessed by completion (success/failure), procedure time, and safety events (catheterization, anesthesia). Pre and post CMR body temperature was recorded. Concurrent invasive hemodynamic and diagnostic CMR data were collected. RESULTS: During a twenty-two month period (3/2015 - 12/2016), enrolled subjects had the following clinical indications: post-heart transplant 33%, shunt 28%, pulmonary hypertension 18%, cardiomyopathy 15%, valvular heart disease 3%, and other 3%. Radiation-free CMR guided right heart catheterization attempts were all successful using passive catheters. In two subjects with septal defects, right and left heart catheterization were performed. There were no complications. One subject had six such procedures. Most subjects (51%) had undergone multiple (5.5 ± 5) previous X-Ray cardiac catheterizations. Retained thoracic surgical or transcatheter implants (36%) did not preclude successful CMR fluoroscopy heart catheterization. During the procedure, two subjects were receiving vasopressor infusions at baseline because of poor cardiac function, and in ten procedures, multiple hemodynamic conditions were tested. CONCLUSIONS: Comprehensive CMR fluoroscopy guided right heart catheterization was feasible and safe in this small cohort of pediatric subjects. This includes subjects with previous metallic implants, those requiring continuous vasopressor medication infusions, and those requiring pharmacologic provocation. Children requiring multiple, serial X-Ray cardiac catheterizations may benefit most from radiation sparing. This is a step toward wholly CMR guided diagnostic (right and left heart) cardiac catheterization and future CMR guided cardiac intervention. TRIAL REGISTRATION: ClinicalTrials.gov NCT02739087 registered February 17, 2016.


Assuntos
Cateterismo Cardíaco/métodos , Cardiopatias/diagnóstico , Imagem por Ressonância Magnética Intervencionista , Exposição à Radiação/prevenção & controle , Adolescente , Fatores Etários , Criança , Estudos de Viabilidade , Feminino , Cardiopatias/fisiopatologia , Hemodinâmica , Humanos , Masculino , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos , Fatores de Tempo
12.
J Am Coll Cardiol ; 70(6): 745-752, 2017 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-28774381

RESUMO

BACKGROUND: In the care of patients with congenital heart disease, percutaneous interventional treatments have supplanted many surgical approaches for simple lesions, such as atrial septal defect. By contrast, complex congenital heart defects continue to require open-heart surgery. In single-ventricle patients, a staged approach is employed, which requires multiple open-heart surgeries and significant attendant morbidity and mortality. A nonsurgical transcatheter alternative would be attractive. OBJECTIVES: The authors sought to show the feasibility of catheter-only, closed-chest, large-vessel anastomosis (superior vena cava and pulmonary artery [PA] or bidirectional Glenn operation equivalent) in a patient. METHODS: In preclinical testing over a decade, the authors developed the techniques and technology needed for nonsurgical crossing from a donor (superior vena cava) to a recipient (PA) vessel and endovascular stent-based anastomosis of those blood vessels. The authors undertook this transcatheter approach for an adult with untreated congenital heart disease with severe cyanosis and significant surgical risk. They rehearsed the procedure step by step using contrast-enhanced cardiac computed tomography and a patient-specific 3-dimensional printed heart model. RESULTS: The authors describe a first-in-human, fully percutaneous superior cavopulmonary anastomosis (bidirectional Glenn operation equivalent). The patient, a 35-year-old woman, was homebound due to dyspnea and worsening cyanosis. She was diagnosed with functional single ventricle and very limited pulmonary blood flow. The heart team believed surgical palliation conferred high operative risk due to the patient's complete condition. With the percutaneous procedure, the patient recovered uneventfully and remained improved clinically after 6 months. CONCLUSIONS: This procedure may provide a viable alternative to one of the foundational open-heart surgeries currently performed to treat single-ventricle congenital heart disease.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Derivação Cardíaca Direita/métodos , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração/cirurgia , Artéria Pulmonar/cirurgia , Veia Cava Superior/cirurgia , Adulto , Estudos de Viabilidade , Feminino , Cardiopatias Congênitas/diagnóstico , Humanos , Imageamento Tridimensional , Tomografia Computadorizada por Raios X
13.
J Cardiovasc Electrophysiol ; 28(5): 517-522, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28245348

RESUMO

BACKGROUND: Arrhythmia ablation with current techniques is not universally successful. Inadequate ablation lesion formation may be responsible for some arrhythmia recurrences. Periprocedural visualization of ablation lesions may identify inadequate lesions and gaps to guide further ablation and reduce risk of arrhythmia recurrence. METHODS: This feasibility study assessed acute postprocedure ablation lesions by MRI, and correlated these findings with clinical outcomes. Ten pediatric patients who underwent ventricular tachycardia ablation were transferred immediately postablation to a 1.5T MRI scanner and late gadolinium enhancement (LGE) imaging was performed to characterize ablation lesions. Immediate and mid-term arrhythmia recurrences were assessed. RESULTS: Patient characteristics include median age 14 years (1-18 years), median weight 52 kg (11-81 kg), normal cardiac anatomy (n = 6), d-transposition of great arteries post arterial switch repair (n = 2), anomalous coronary artery origin post repair (n = 1), and cardiac rhabdomyoma (n = 1). All patients underwent radiofrequency catheter ablation of ventricular arrhythmia with acute procedural success. LGE was identified at the reported ablation site in 9/10 patients, all arrhythmia-free at median 7 months follow-up. LGE was not visible in 1 patient who had recurrence of frequent premature ventricular contractions within 2 hours, confirmed on Holter at 1 and 21 months post procedure. CONCLUSIONS: Ventricular ablation lesion visibility by MRI in the acute post procedure setting is feasible. Lesions identifiable with MRI may correlate with clinical outcomes. Acute MRI identification of gaps or inadequate lesions may provide the unique temporal opportunity for additional ablation therapy to decrease arrhythmia recurrence.


Assuntos
Ablação por Cateter , Ventrículos do Coração/cirurgia , Imageamento por Ressonância Magnética , Taquicardia Ventricular/cirurgia , Adolescente , Fatores Etários , Ablação por Cateter/efeitos adversos , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Recidiva , Fatores de Risco , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
14.
JACC Basic Transl Sci ; 1(5): 376-383, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27631028

RESUMO

BACKGROUND: Diagnostic yield of endomyocardial biopsy is low, particularly in disease that affects the myocardium in a non-uniform distribution. We hypothesized that real-time MRI guidance could improve the yield through targeted biopsy of focal myocardial pathology. METHODS: An animal model of focal myocardial pathology was created by infusing 3mL of fluorescent microspheres (NuFlow Hydrocoat, 15µm diameter, 5 million spheres/mL) followed by 2mL of 100% ethanol to a branch coronary artery. Animals were survived for minimum 14days, before undergoing MRI guided endomyocardial biopsy using a custom 6.5Fr active visualization MRI-conditional bioptome and X-ray guided biopsy using a commercial bioptome. Specimens were analyzed using a dissecting microscope under ultraviolet light to determine the proportion of 'on-target' specimens containing fluorescent microspheres. RESULTS: A total of 77 specimens were obtained using real-time MRI guidance and 87 using X-ray guidance, in five animals. Specimens obtained with the MRI-conditional bioptome were smaller compared with the commercial X-ray bioptome. Real-time MRI guidance significantly increased the diagnostic yield of endomyocardial biopsy (82% vs. 56% on-target biopsy specimens with real-time MRI vs. X-ray guidance, p<0.01). CONCLUSIONS: Endomyocardial biopsy performed using real-time MRI guidance is feasible and significantly improves the diagnostic yield compared with X-ray fluoroscopy guidance.

15.
J Thorac Cardiovasc Surg ; 151(4): 1126-35.e2, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26611747

RESUMO

OBJECTIVES: Patients with single ventricle congenital heart disease often form aortopulmonary collateral vessels via an unclear mechanism. To gain insights into the pathogenesis of aortopulmonary collateral vessels, we correlated angiogenic factor levels with in vitro activity and angiographic aortopulmonary collateral assessment and examined whether patients with single ventricle physiology have increased angiogenic factors that can stimulate endothelial cell sprouting in vitro. METHODS: In patients with single ventricle physiology (n = 27) and biventricular acyanotic control patients (n = 21), hypoxia-inducible angiogenic factor levels were measured in femoral venous and arterial plasma at cardiac catheterization. To assess plasma angiogenic activity, we used a 3-dimensional in vitro cell sprouting assay that recapitulates angiogenic sprouting. Aortopulmonary collateral angiograms were graded using a 4-point scale. RESULTS: Compared with controls, patients with single ventricle physiology had increased vascular endothelial growth factor (artery: 58.7 ± 1.2 pg/mL vs 35.3 ± 1.1 pg/mL, P < .01; vein: 34.8 ± 1.1 pg/mL vs 21 ± 1.2 pg/mL, P < .03), stromal-derived factor 1-alpha (artery: 1901.6 ± 1.1 pg/mL vs 1542.6 ± 1.1 pg/mL, P < .03; vein: 2092.8 pg/mL ± 1.1 vs 1752.9 ± 1.1 pg/mL, P < .02), and increased arterial soluble fms-like tyrosine kinase-1, a regulatory vascular endothelial growth factor receptor (612.3 ± 1.2 pg/mL vs 243.1 ± 1.2 pg/mL, P < .003). Plasma factors and sprout formation correlated poorly with aortopulmonary collateral severity. CONCLUSIONS: We are the first to correlate plasma angiogenic factor levels with angiography and in vitro angiogenic activity in patients with single ventricle disease with aortopulmonary collaterals. Patients with single ventricle disease have increased stromal-derived factor 1-alpha and soluble fms-like tyrosine kinase-1, and their roles in aortopulmonary collateral formation require further investigation. Plasma factors and angiogenic activity correlate poorly with aortopulmonary collateral severity in patients with single ventricles, suggesting complex mechanisms of angiogenesis.


Assuntos
Proteínas Angiogênicas/sangue , Aorta/fisiopatologia , Circulação Colateral , Células Endoteliais/metabolismo , Cardiopatias Congênitas/sangue , Neovascularização Fisiológica , Artéria Pulmonar/fisiopatologia , Circulação Pulmonar , Adolescente , Aortografia , Estudos de Casos e Controles , Células Cultivadas , Quimiocina CXCL12/sangue , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/fisiopatologia , Humanos , Lactente , Masculino , Fator A de Crescimento do Endotélio Vascular/sangue , Receptor 2 de Fatores de Crescimento do Endotélio Vascular/sangue
17.
J Thorac Cardiovasc Surg ; 147(4): 1271-5, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24530198

RESUMO

BACKGROUND: Previous attempts to support single ventricle circulation mechanically have suggested that a custom-built assist device is needed to push, rather than pull, through the pulmonary circulation. We hypothesized that using a conventional ventricular assist device, with or without conversion of a total cavopulmonary connection to a bidirectional Glenn cavopulmonary connection, would allow assistance by pulling blood through the circuit and improve the cardiac index (CI). METHODS: Cavopulmonary connections were established in each of 5 Yorkshire pigs (25 kg) using ePTFE conduits in a Y configuration with appropriate clamping of the limbs of the Y to achieve a total cavopulmonary Fontan connection (TCPC), superior vena cava cavopulmonary connection (SVC Glenn), and inferior vena cava cavopulmonary connection (IVC Glenn). A common atrium had been established previously by balloon septostomy. Mechanical circulatory assistance of the single systemic ventricle was achieved using a centrifugal pump with common atrial inflow and proximal ascending aortic outflow. The CI was calculated using an ultrasonic flow meter placed on the distal ascending aorta and compared between the assisted and nonassisted circulation for 3 conditions: TCPC, SVC Glenn, and IVC Glenn. The mean pulmonary artery pressure, common atrial pressure, arterial oxygen saturation, partial pressure of arterial oxygen, and oxygen delivery were calculated. RESULTS: The unassisted SVC Glenn CI tended to be greater than the TCPC or IVC Glenn CI. Significant augmentation of total CI was achieved with mechanical assistance for SVC Glenn (109% ± 24%, P = .04) and TCPC (130% ± 109%, P = .01). The assisted CI achieved at least a mean baseline biventricular CI for all 3 support modes. Oxygen delivery was greatest for assisted SVC Glenn (1786 ± 1307 mL/L/min) and lowest for TCPC (1146 ± 386 mL/L/min), with a trend toward lower common atrial and pulmonary artery pressures for SVC Glenn. CONCLUSIONS: SVC bidirectional Glenn circulation might allow optimal augmentation of the CI and oxygen delivery in a failing single ventricle using a conventional pediatric ventricular assist device. The results from our model also suggest that the Fontan circulation itself can be supported with systemic ventricular assistance of the single ventricle.


Assuntos
Coração Auxiliar , Artéria Pulmonar/cirurgia , Veia Cava Superior/cirurgia , Função Ventricular , Anastomose Cirúrgica , Animais , Procedimentos Cirúrgicos Cardíacos/métodos , Fluxo Sanguíneo Regional , Suínos , Procedimentos Cirúrgicos Vasculares/métodos
18.
Med Phys ; 40(3): 032302, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23464334

RESUMO

PURPOSE: Volumetric roadmaps overlaid on live x-ray fluoroscopy may be used to enhance image guidance during interventional procedures. These roadmaps are often static and do not reflect cardiac or respiratory motion. In this work, the authors present a method for integrating cardiac and respiratory motion into magnetic resonance imaging (MRI)-derived roadmaps to fuse with live x-ray fluoroscopy images, and this method was tested in large animals. METHODS: Real-time MR images were used to capture cardiac and respiratory motion. Nonrigid registration was used to calculate motion fields to deform a reference end-expiration, end-diastolic image to different cardiac and respiratory phases. These motion fields were fit to separate affine motion models for the aorta and proximal right coronary artery. Under x-ray fluoroscopy, an image-based navigator and ECG signal were used as inputs to deform the roadmap for live overlay. The in vivo accuracy of motion correction was measured in four swine as the ventilator tidal volume was varied. RESULTS: Motion correction reduced the root-mean-square error between the roadmaps and manually drawn centerlines, even under high tidal volume conditions. For the aorta, the error was reduced from 2.4 ± 1.5 mm to 2.2 ± 1.5 mm (p < 0.05). For the proximal right coronary artery, the error was reduced from 8.8 ± 16.2 mm to 4.3 ± 5.2 mm (p < 0.001). Using real-time MRI and an affine motion model it is feasible to incorporate physiological cardiac and respiratory motion into MRI-derived roadmaps to provide enhanced image guidance for interventional procedures. CONCLUSIONS: A method has been presented for creating dynamic 3D roadmaps that incorporate cardiac and respiratory motion. These roadmaps can be overlaid on live X-ray fluoroscopy to enhance image guidance for cardiac interventions.


Assuntos
Fluoroscopia/métodos , Coração/fisiologia , Imageamento por Ressonância Magnética/métodos , Movimento , Respiração , Animais , Cirurgia Assistida por Computador , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA