Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
EJNMMI Res ; 14(1): 46, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750398

RESUMO

BACKGROUND: Approaches targeting the sodium-glucose cotransporter (SGLT) could represent a promising future therapeutic strategy for numerous oncological and metabolic diseases. In this study, we evaluated the safety, biodistribution and radiation dosimetry of the glucose analogue positron emission tomography (PET) agent [18F] labeled alpha-methyl-4-deoxy-4-[18F]fluoro-D-glucopyranoside ([18F]Me4FDG) with high sodium-glucose cotransporter and low glucose transporter (GLUT) affinity. For this purpose, five healthy volunteers (1 man, 4 women) underwent multiple whole-body PET/computed tomography (CT) examinations starting with injection and up to 4 h after injection of averaged (2.4 ± 0.1) MBq/kg (range: 2.3-2.5 MBq/kg) administered activity. The PET/CT scans were conducted in 5 separate sessions, blood pressure and temperature were measured, and blood and urine samples were collected before the scans and one hour after injection to assess toxicity. Measurements of [18F]Me4FDG radioactivity in organs of interest were determined from the PET/CT scans at 5 time points. Internal dosimetry was performed on voxel level using a fast Monte Carlo approach. RESULTS: All studied volunteers could well tolerate the [18F]Me4FDG and no adverse event was reported. The calculated effective dose was (0.013 ± 0.003) mSv/MBq. The organs with the highest absorbed dose were the kidneys with 0.05 mSv/MBq per kidney. The brain showed almost no uptake. After 60 min, (12 ± 15) % of the administered dose was excreted into the bladder. CONCLUSION: Featuring an effective dose of only 0.013 ± 0.003 mSv/MBq and no occurrence of side effects, the glucose analogue [18F]Me4FDG seems to be a safe radio-tracer with a favorable biodistribution for PET imaging and also within several consecutive scans. TRIAL REGISTRATION NUMBER: NCT03557138, Registered 22 February 2017, https://ichgcp.net/clinical-trials-registry/NCT03557138 .

2.
Int J Mol Sci ; 24(18)2023 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-37761975

RESUMO

To investigate the use of kinetic parameters derived from direct Patlak reconstructions of [68Ga]Ga-PSMA-11 positron emission tomography/computed tomography (PET/CT) to predict the histological grade of malignancy of the primary tumor of patients with prostate cancer (PCa). Thirteen patients (mean age 66 ± 10 years) with a primary, therapy-naïve PCa (median PSA 9.3 [range: 6.3-130 µg/L]) prior radical prostatectomy, were recruited in this exploratory prospective study. A dynamic whole-body [68Ga]Ga-PSMA-11 PET/CT scan was performed for all patients. Measured quantification parameters included Patlak slope (Ki: absolute rate of tracer consumption) and Patlak intercept (Vb: degree of tracer perfusion in the tumor). Additionally, the mean and maximum standardized uptake values (SUVmean and SUVmax) of the tumor were determined from a static PET 60 min post tracer injection. In every patient, initial PSA (iPSA) values that were also the PSA level at the time of the examination and final histology results with Gleason score (GS) grading were correlated with the quantitative readouts. Collectively, 20 individual malignant prostate lesions were ascertained and histologically graded for GS with ISUP classification. Six lesions were classified as ISUP 5, two as ISUP 4, eight as ISUP 3, and four as ISUP 2. In both static and dynamic PET/CT imaging, the prostate lesions could be visually distinguished from the background. The average values of the SUVmean, slope, and intercept of the background were 2.4 (±0.4), 0.015 1/min (±0.006), and 52% (±12), respectively. These were significantly lower than the corresponding parameters extracted from the prostate lesions (all p < 0.01). No significant differences were found between these values and the various GS and ISUP (all p > 0.05). Spearman correlation coefficient analysis demonstrated a strong correlation between static and dynamic PET/CT parameters (all r ≥ 0.70, p < 0.01). Both GS and ISUP grading revealed only weak correlations with the mean and maximum SUV and tumor-to-background ratio derived from static images and dynamic Patlak slope. The iPSA demonstrated no significant correlation with GS and ISUP grading or with dynamic and static PET parameter values. In this cohort of mainly high-risk PCa, no significant correlation between [68Ga]Ga-PSMA-11 perfusion and consumption and the aggressiveness of the primary tumor was observed. This suggests that the association between SUV values and GS may be more distinctive when distinguishing clinically relevant from clinically non-relevant PCa.

3.
Cancers (Basel) ; 15(10)2023 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-37345077

RESUMO

OBJECTIVES: Advanced MR imaging of brain tumors is still mainly based on qualitative imaging. PET imaging offers additive metabolic information, and MR fingerprinting (MRF) offers a novel approach to quantitative data acquisition. The purpose of this study was to evaluate the ability of MRF to predict tumor regions and grading in combination with PET. METHODS: Seventeen patients with histologically verified infiltrating gliomas and available amino-acid PET data were enrolled. ROIs for solid tumor parts (SPo), perifocal edema (ED1), and normal-appearing white matter (NAWM) were selected on conventional MRI sequences and aligned to the MRF and PET images. The predictability of gliomas by region and grading as well as intermodal correlations were assessed. RESULTS: For MRF, we calculated an overall predictability by region (SPo, ED1, and NAWM) for all of the MRF parameters of 76.5%, 47.1%, and 94.1%, respectively. The overall ability to distinguish low- from high-grade gliomas using MRF was 88.9% for LGG and 75% for HGG, with an accuracy of 82.4%, a ppV of 85.71%, and an npV of 80%. PET positivity was found in 13/17 patients for solid tumor parts, and in 3/17 patients for the edema region. However, there was no significant difference in region-specific MRF values between PET positive and PET negative patients. CONCLUSIONS: MRF and PET provide quantitative measurements of the tumor tissue characteristics of gliomas, with good predictability. Nonetheless, the results are dissimilar, reflecting the different underlying mechanisms of each method.

4.
Front Oncol ; 13: 986788, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36816966

RESUMO

Introduction: Amino-acid positron emission tomography (PET) is a validated metabolic imaging approach for the diagnostic work-up of gliomas. This study aimed to evaluate sex-specific radiomic characteristics of L-[S-methyl-11Cmethionine (MET)-PET images of glioma patients in consideration of the prognostically relevant biomarker isocitrate dehydrogenase (IDH) mutation status. Methods: MET-PET of 35 astrocytic gliomas (13 females, mean age 41 ± 13 yrs. and 22 males, mean age 46 ± 17 yrs.) and known IDH mutation status were included. All patients underwent radiomic analysis following imaging biomarker standardization initiative (IBSI)-conform guidelines both from standardized uptake value (SUV) and tumor-to-background ratio (TBR) PET values. Aligned Monte Carlo (MC) 100-fold split was utilized for SUV and TBR dataset pairs for both sex and IDH-specific analysis. Borderline and outlier scores were calculated for both sex and IDH-specific MC folds. Feature ranking was performed by R-squared ranking and Mann-Whitney U-test together with Bonferroni correction. Correlation of SUV and TBR radiomics in relation to IDH mutational status in male and female patients were also investigated. Results: There were no significant features in either SUV or TBR radiomics to distinguish female and male patients. In contrast, intensity histogram coefficient of variation (ih.cov) and intensity skewness (stat.skew) were identified as significant to predict IDH +/-. In addition, IDH+ females had significant ih.cov deviation (0.031) and mean stat.skew (-0.327) differences compared to IDH+ male patients (0.068 and -0.123, respectively) with two-times higher standard deviations of the normal brain background MET uptake as well. Discussion: We demonstrated that female and male glioma patients have significantly different radiomic profiles in MET PET imaging data. Future IDH prediction models shall not be built on mixed female-male cohorts, but shall rely on sex-specific cohorts and radiomic imaging biomarkers.

5.
Cancers (Basel) ; 14(18)2022 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-36139596

RESUMO

Aim: The aim of this study was to assess the effects of including somatostatin receptor agonist (SSTR) PET imaging in meningioma radiotherapy planning by means of changes in inter-observer variability (IOV). Further, the possibility of using threshold-based delineation approaches for semiautomatic tumor volume definition was assessed. Patients and Methods: Sixteen patients with meningioma undergoing fractionated radiotherapy were delineated by five radiation oncologists. IOV was calculated by comparing each delineation to a consensus delineation, based on the simultaneous truth and performance level estimation (STAPLE) algorithm. The consensus delineation was used to adapt a threshold-based delineation, based on a maximization of the mean Dice coefficient. To test the threshold-based approach, seven patients with SSTR-positive meningioma were additionally evaluated as a validation group. Results: The average Dice coefficients for delineations based on MRI alone was 0.84 ± 0.12. For delineation based on MRI + PET, a significantly higher dice coefficient of 0.87 ± 0.08 was found (p < 0.001). The Hausdorff distance decreased from 10.96 ± 11.98 mm to 8.83 ± 12.21 mm (p < 0.001) when adding PET for the lesion delineation. The best threshold value for a threshold-based delineation was found to be 14.0% of the SUVmax, with an average Dice coefficient of 0.50 ± 0.19 compared to the consensus delineation. In the validation cohort, a Dice coefficient of 0.56 ± 0.29 and a Hausdorff coefficient of 27.15 ± 21.54 mm were found for the threshold-based approach. Conclusions: SSTR-PET added to standard imaging with CT and MRI reduces the IOV in radiotherapy planning for patients with meningioma. When using a threshold-based approach for PET-based delineation of meningioma, a relatively low threshold of 14.0% of the SUVmax was found to provide the best agreement with a consensus delineation.

6.
Med Phys ; 49(9): 5819-5829, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35838056

RESUMO

BACKGROUND: Hybrid imaging (e.g., positron emission tomography [PET]/computed tomography [CT], PET/magnetic resonance imaging [MRI]) helps one to visualize and quantify morphological and physiological tumor characteristics in a single study. The noninvasive characterization of tumor heterogeneity is essential for grading, treatment planning, and following-up oncological patients. However, conventional (CONV) image-based parameters, such as tumor diameter, tumor volume, and radiotracer activity uptake, are insufficient to describe tumor heterogeneities. Here, radiomics shows promise for a better characterization of tumors. Nevertheless, the validation of such methods demands imaging objects capable of reflecting heterogeneities in multi-modality imaging. We propose a phantom to simulate tumor heterogeneity repeatably in PET, CT, and MRI. METHODS: The phantom consists of three 50-ml plastic tubes filled partially with acrylic spheres of S1: 1.6 mm, S2: 50%(1.6 mm)/50%(6.3 mm), or S3: 6.3-mm diameter. The spheres were fixed to the bottom of each tube by a plastic grid, yielding one sphere free homogeneous region and one heterogeneous (S1, S2, or S3) region per tube. A 3-tube phantom and its replica were filled with a fluorodeoxyglucose (18F) solution for test-retest measurements in a PET/CT Siemens TPTV and a PET/MR Siemens Biograph mMR system. A number of 42 radiomic features (10 first order and 32 texture features) were calculated for each phantom region and imaging modality. Radiomic features stability was evaluated through coefficients of variation (COV) across phantoms and scans for PET, CT, and MRI. Further, the Wilcoxon test was used to assess the capability of stable features to discriminate the simulated phantom regions. RESULTS: The different patterns (S1-S3) did present visible heterogeneity in all imaging modalities. However, only for CT and MRI, a clear visual difference was present between the different patterns. Across all phantom regions in PET, CT, and MR images, 10, 16, and 21 features out of 42 evaluated features in total had a COV of 10% or less. In particular, CONV, histogram, and gray-level run length matrix features showed high repeatability for all the phantom regions and imaging modalities. Several of repeatable texture features allowed the image-based discrimination of the different phantom regions (p < 0.05). However, depending on the feature, different pattern discrimination capabilities were found for the different imaging modalities. CONCLUSION: The proposed phantom appears suitable for simulating heterogeneities in PET, CT, and MRI. We demonstrate that it is possible to select radiomic features for the readout of the phantom. Most of these features had been shown to be relevant in previous clinical studies.


Assuntos
Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Neoplasias/diagnóstico por imagem , Imagens de Fantasmas , Plásticos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons
7.
Cancers (Basel) ; 14(9)2022 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-35565293

RESUMO

(1) Background: Recent developments in 7T magnetic resonance spectroscopic imaging (MRSI) made the acquisition of high-resolution metabolic images in clinically feasible measurement times possible. The amino acids glutamine (Gln) and glycine (Gly) were identified as potential neuro-oncological markers of importance. For the first time, we compared 7T MRSI to amino acid PET in a cohort of glioma patients. (2) Methods: In 24 patients, we co-registered 7T MRSI and routine PET and compared hotspot volumes of interest (VOI). We evaluated dice similarity coefficients (DSC), volume, center of intensity distance (CoI), median and threshold values for VOIs of PET and ratios of total choline (tCho), Gln, Gly, myo-inositol (Ins) to total N-acetylaspartate (tNAA) or total creatine (tCr). (3) Results: We found that Gln and Gly ratios generally resulted in a higher correspondence to PET than tCho. Using cutoffs of 1.6-times median values of a control region, DSCs to PET were 0.53 ± 0.36 for tCho/tNAA, 0.66 ± 0.40 for Gln/tNAA, 0.57 ± 0.36 for Gly/tNAA, and 0.38 ± 0.31 for Ins/tNAA. (4) Conclusions: Our 7T MRSI data corresponded better to PET than previous studies at lower fields. Our results for Gln and Gly highlight the importance of future research (e.g., using Gln PET tracers) into the role of both amino acids.

8.
Z Med Phys ; 32(4): 466-476, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35597743

RESUMO

The choice of materials challenges the development of Magnetic Resonance Imaging (MRI) phantoms and, to date, is mainly limited to water-filled compartments or gel-based components. Recently, solid materials have been introduced through additive manufacturing (AM) to mimic complex geometrical structures. Nonetheless, no such manufactured solid materials are available with controllable MRI contrast to mimic organ substructures or lesion heterogeneities. Here, we present a novel AM design that allows MRI contrast manipulation by varying the partial volume contribution to a ROI/voxel of MRI-visible material within an imaging object. Two sets of 11 cubes and three replicates of a spherical tumour model were designed and printed using AM. Most samples presented varying MRI-contrast in standard MRI sequences, based mainly on spin density and partial volume signal variation. A smooth and continuous MRI-contrast gradient could be generated in a single-compartment tumour model. This concept supports the development of more complex MRI phantoms that mimic the appearance of heterogeneous tumour tissues.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias , Humanos , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos , Impressão Tridimensional
9.
Z Med Phys ; 32(3): 283-295, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35067426

RESUMO

PURPOSE: To assess dose levels in routine nuclear medicine (NUC) procedures in Austria as a prior to a legislative update of the National Diagnostic Reference Levels (NDRL). METHOD: As part of a nationwide survey of common NUC-examinations between June 2019 and November 2019, data sets were collected from 33 Austrian hospitals with NUC equipment. All hospitals were asked to report the NUC imaging devices in use (model, type, year of manufacture, detector material, collimators), the standard protocol parameters for selected examinations (standard activity, collimator, average acquisition time, reconstruction type, use of time-of-flight) and to report data from 10 representative examinations (e.g. injected activity, weight), incl. the most common NUC-examinations for planar imaging/SPECT and PET. Median/mean values for injected activity were calculated and compared to current Austrian and international NDRL. A Pearson correlation coefficient was computed comparing different variables. RESULTS: In total, all 33 hospitals (100% response rate) reported data for this study for 60 SPECT devices, 21 PET/CT devices and 23 scintigraphy devices. Fixed activity values for scintigraphy/SPECT and PET were employed by about 90% and 56% of the hospitals, respectively. The most widely performed examinations for scintigraphy/SPECT are bone imaging, thyroid imaging, renal imaging (with MAG3/EC) and lung perfusion imaging (in 88% of the hospitals) and F-18 FDG-PET studies for oncology indications (in 100% of the hospitals). Significant correlations were found for patient weight and injected activity (scintigraphy/SPECT), use of iterative reconstruction and injected activity (PET) as well as size of field-of-view and injected activity (PET). CONCLUSIONS: The reported injected activity levels were comparable to those in other countries. However, for procedures for which NDRL exist, deviations in injected activities of >20% compared to the NDRL were found. These deviations are assumed to result mainly from advances in technology but also from deviations between NDRL and prescribed activities as given in the information leaflets of the radiopharmaceuticals.


Assuntos
Medicina Nuclear , Adulto , Áustria , Níveis de Referência de Diagnóstico , Fluordesoxiglucose F18 , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único
10.
Mol Imaging Biol ; 23(5): 775-786, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33846898

RESUMO

PURPOSE: To investigate the possibility of reducing the injected activity for whole-body [18F]FDG-PET/CT studies of paediatric oncology patients and to assess the usefulness of time-of-flight (TOF) acquisition on PET image quality at reduced count levels. PROCEDURES: Twenty-nine paediatric oncology patients (12F/17M, 3-18 years old (median age 13y), weight 45±20 kg, BMI 19±4 kg/m2), who underwent routine whole-body PET/CT examinations on a Siemens Biograph mCT TrueV system with TOF capability (555ps) were included in this study. The mean injected activity was 156 ± 45 MBq (3.8 ± 0.8 kg/MBq) and scaled to patient weight. The raw data was collected in listmode (LM) format and pre-processed to simulate reduced levels of [18F]FDG activity (75, 50, 35, 20 and 10% of the original counts) by randomly removing events from the original LM data. All data were reconstructed using the vendor-specific e7-tools with standard OSEM only, with OSEM plus resolution recovery (PSF). The reconstructions were repeated with added TOF (TOF) and PSF+TOF. The benefit of TOF together with the reduced count levels was evaluated by calculating the gains in signal-to-noise ratio (SNR) in the liver and contrast-to-noise ratio (CNR) in all PET-positive lesions before and after TOF employed at every simulated reduced count level. Finally, the PSF+TOF images at 50, 75 and 100% of counts were evaluated clinically on a 5-point scale by three nuclear medicine physicians. RESULTS: The visual inspection of the reconstructed images did not reveal significant differences in image quality between 75 and 100% count levels for PSF+TOF. The improvements in SNR and CNR were the greatest for TOF reconstruction and PSF combined. Both SNR and CNR gains did increase linearly with the patients BMI for both OSEM only and PSF reconstruction. These benefits were observed until reducing the counts to 50 and 35% for SNR and CNR, respectively. CONCLUSIONS: The benefit of using TOF was noticeable when using 50% or greater of the counts when evaluating the CNR and SNR. For [18F]FDG-PET/CT, whole-body paediatric imaging the injected activity can be reduced to 75% of the original dose without compromising PET image quality.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Doses de Radiação , Adolescente , Pré-Escolar , Feminino , Fluordesoxiglucose F18/administração & dosagem , Fluordesoxiglucose F18/uso terapêutico , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Razão Sinal-Ruído
11.
Clin Nucl Med ; 46(1): 16-20, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33208624

RESUMO

PURPOSE OF THE REPORT: F-FDG PET is limited for assessment of central nervous system lymphoma (CNSL) due to physiologic tracer accumulation in the brain. We prospectively evaluated the novel PET tracer Ga-pentixafor, which targets the C-X-C chemokine receptor 4 (CXCR4), for lesion visualization and response assessment of CNSL. MATERIALS AND METHODS: Seven CNSL patients underwent Ga-pentixafor PET/MRI with contrast enhancement (CE-MRI) and diffusion-weighted sequences. The accuracy of Ga-pentixafor PET for CNSL lesion detection relative to the CE-MRI reference standard was determined. Standardized uptake values (SUVmean and SUVmax), PET-based (PTV) and MRI-based (VOLMRI) tumor volumes, and apparent diffusion coefficients (ADCs) were assessed, and correlation coefficients were calculated. Three SUVmax thresholds (41%, 50%, and 70%) were evaluated for PTV definitions (PTV41%, PTV50%, and PTV70%) and tested against VOLMRI using paired sample t tests. RESULTS: Twelve Ga-pentixafor PET/MRI examinations (including 5 follow-up scans) of 7 patients were evaluated. Ga-pentixafor PET demonstrated 18 lesions, all of which were confirmed by CE-MRI; there were no false-positive lesions on PET (accuracy, 100%). PTV41% showed the highest concordance with lesion morphology, with no significant difference compared with VOLMRI (mean difference, -0.24 cm; P = 0.45). The correlation between ADCmean and SUVmean41% (r = 0.68) was moderate. Changes in PTV41% on follow-up PET/MRI showed the same trend as VOLMRI changes, including progression of 1 lesion each in patient 1 (+456.0% PTV41% and +350.8% VOLMRI) and patient 3 (+110.4% PTV41% and +85.1% VOLMRI). CONCLUSIONS: Ga-pentixafor PET may be feasible for assessment and follow-up of CNSL. Future studies need to focus on testing its clinical value to distinguish between glioma and CNSL, and between radiation-induced inflammation and viable residual tumor.


Assuntos
Neoplasias do Sistema Nervoso Central/diagnóstico por imagem , Neoplasias do Sistema Nervoso Central/metabolismo , Complexos de Coordenação , Imageamento por Ressonância Magnética , Peptídeos Cíclicos , Tomografia por Emissão de Pósitrons , Receptores CXCR4/metabolismo , Adulto , Feminino , Regulação Neoplásica da Expressão Gênica , Humanos , Masculino , Pessoa de Meia-Idade
12.
Med Phys ; 47(4): 2023-2037, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31981214

RESUMO

BACKGROUND: In oncology, lesion characterization is essential for tumor grading, treatment planning, and follow-up of cancer patients. Hybrid imaging systems, such as Single Photon Emission Computed Tomography (SPECT)/CT, Positron Emission Tomography (PET)/CT, or PET/magnetic resonance imaging (MRI), play an essential role for the noninvasive quantification of tumor characteristics. However, most of the existing approaches are challenged by intra- and intertumor heterogeneity. Novel quantitative imaging parameters that can be derived from textural feature analysis (as part of radiomics) are promising complements for improved characterization of tumor heterogeneity, thus, supporting clinically relevant implementations of personalized medicine concepts. Nevertheless, establishing new quantitative parameters for tumor characterization requires the use of standardized imaging objects to test the reliability of results prior to their implementation in patient studies. METHODS: In this review, we summarize existing reports on heterogeneous phantoms with a focus on simulating tumor heterogeneity. We discuss the techniques, materials, advantages, and limitations of the existing phantoms for PET, CT, and MR imaging modalities. CONCLUSIONS: Finally, we outline the future directions and requirements for the design of cross modality imaging phantoms.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Neoplasias/diagnóstico por imagem , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Humanos , Neoplasias/patologia , Impressão Tridimensional
13.
Eur J Nucl Med Mol Imaging ; 47(1): 51-60, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31410538

RESUMO

PURPOSE: PET/MRI has recently been introduced into clinical practice. We prospectively investigated the clinical impact of PET/MRI compared with PET/CT, in a mixed population of cancer patients, and performed an economic evaluation of PET/MRI. METHODS: Cancer patients referred for routine staging or follow-up by PET/CT underwent consecutive PET/CT and PET/MRI, using single applications of [18F]FDG, [68Ga]Ga-DOTANOC, or [18F]FDOPA, depending on tumor histology. PET/MRI and PET/CT were rated separately, and lesions were assessed per anatomic region; based on regions, per-examination and per-patient accuracies were determined. A simulated, multidisciplinary team meeting served as reference standard and determined whether differences between PET/CT and PET/MRI affected patient management. The McNemar tests were used to compare accuracies, and incremental cost-effectiveness ratios (ICERs) for PET/MRI were calculated. RESULTS: Two hundred sixty-three patients (330 same-day PET/CT and PET/MRI examinations) were included. PET/MRI was accurate in 319/330 examinations and PET/CT in 277/330 examinations; the respective accuracies of 97.3% and 83.9% differed significantly (P < 0.001). The additional findings on PET/MRI-mainly liver and brain metastases-had implications for patient management in 21/263 patients (8.0%). The per-examination cost was 596.97 EUR for PET/MRI and 405.95 EUR for PET/CT. ICERs for PET/MRI were 14.26 EUR per percent of diagnostic accuracy and 23.88 EUR per percent of correctly managed patients. CONCLUSIONS: PET/MRI enables more appropriate management than PET/CT in a nonnegligible fraction of cancer patients. Since the per-examination cost is about 50% higher for PET/MRI than for PET/CT, a histology-based triage of patients to either PET/MRI or PET/CT may be meaningful.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Estudos Prospectivos
14.
Phys Med ; 65: 76-83, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31437602

RESUMO

Hybrid PET/MR offers new opportunities in radiation oncology for tissue/tumour characterisation and response assessment. Attenuation correction (AC) is an important issue especially in the presence of immobilization devices and flat table tops (FTT). The goal of this study was to compare two methods of AC using CT- and 68Ge/68Ga transmission scan-based attenuation maps (µ-maps) for a custom-designed FTT. Measurements were performed in the mMR PET/MR and TrueV PET/CT Biograph Siemens scanners with three different phantoms, namely the Siemens MR-QA, a cubic canister and the NEMA IEC body phantom. The study revealed that the MR image quality is not hampered by the presence of the FTT. For cubic canister applying the scanner's inherent AC alone resulted in inaccuracies in PET images, with up to -4.0% underestimation of the activity. The mean NEMA sphere activity measurements without FTT, agreed within 3.5% with the respective inserted activity. Placing the FTT in the PET/MR scanner resulted in a difference to the injected activity of 4.5% when the table was not corrected for. By introducing the µ-maps the discrepancy between the used activity and the measurements decreased down to 2.6%. To improve the AC of the FTT the creation of a dedicated µ-map was necessary while the CT-based µ-map performed equally good as the source transmission scan-based one.


Assuntos
Radioisótopos de Gálio , Germânio , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Radioisótopos , Tomografia Computadorizada por Raios X , Imagens de Fantasmas
15.
Nuklearmedizin ; 58(2): 68-76, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30818412

RESUMO

Combined PET/MR imaging (PET/MRI) was proposed for patient management in 2006 with first commercial versions of integrated whole-body systems becoming available as of 2010. PET/MRI followed the prior evolution of hybrid imaging as attested by the successful adoption of combined PET/CT and SPECT/CT since the early 2000 s. Today, around 150 whole-body PET/MRI systems have become operational worldwide. One of the main application fields of PET/MRI is oncologic imaging. Despite the increasing use of PET/MRI, little governance regarding standardized PET/MRI protocols has been provided to date. Standardization and harmonization of imaging protocols is, however, mandatory for efficient on-site patient management and multi-center studies. This document summarizes consensus recommendations on key aspects of patient referral and preparation, PET/MRI workflow and imaging protocols, as well as reporting strategies for whole-body [18F]-FDG-PET/MRI. These recommendations were created by early adopters and key experts in the field of PET, MRI and PET/MRI. This document is intended to provide guidance for the harmonization and standardization of PET/ MRI today and to support wider clinical adoption of this imaging modality for the benefit of patients. CITATION FORMAT:: Umutlu L, Beyer T, Grueneisen JS et al. Whole-Body [18F]-FDG-PET/MRI for Oncology: A Consensus Recommendation. Nuklearmedizin 2019, 58: 1-9.


Assuntos
Consenso , Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética , Imagem Multimodal , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Imagem Corporal Total , Humanos , Controle de Qualidade , Projetos de Pesquisa , Segurança
16.
Rofo ; 191(4): 289-297, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30818411

RESUMO

Combined PET/MR imaging (PET/MRI) was proposed for patient management in 2006 with first commercial versions of integrated whole-body systems becoming available as of 2010. PET/MRI followed the prior evolution of hybrid imaging as attested by the successful adoption of combined PET/CT and SPECT/CT since the early 2000 s. Today, around 150 whole-body PET/MRI systems have become operational worldwide. One of the main application fields of PET/MRI is oncologic imaging. Despite the increasing use of PET/MRI, little governance regarding standardized PET/MRI protocols has been provided to date. Standardization and harmonization of imaging protocols is, however, mandatory for efficient on-site patient management and multi-center studies. This document summarizes consensus recommendations on key aspects of patient referral and preparation, PET/MRI workflow and imaging protocols, as well as reporting strategies for whole-body [18F]-FDG-PET/MRI. These recommendations were created by early adopters and key experts in the field of PET, MRI and PET/MRI. This document is intended to provide guidance for the harmonization and standardization of PET/MRI today and to support wider clinical adoption of this imaging modality for the benefit of patients. CITATION FORMAT: · Umutlu L, Beyer T, Grueneisen JS et al. Whole-Body [18F]-FDG-PET/MRI for Oncology: A Consensus Recommendation. Fortschr Röntgenstr 2019; 191: 289 - 297.


Assuntos
Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Imagem Corporal Total/métodos , Artefatos , Humanos , Imageamento por Ressonância Magnética/normas , Educação de Pacientes como Assunto/métodos , Tomografia por Emissão de Pósitrons/normas , Controle de Qualidade , Sistemas de Informação em Radiologia , Imagem Corporal Total/normas , Fluxo de Trabalho
17.
Trop Med Int Health ; 24(6): 663-670, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30851233

RESUMO

BACKGROUND: [18 F]-2-fluoro-2-deoxy-D-glucose (18F-FDG) positron emission tomography/computed tomography (FDG-PET/CT) imaging provides important information about the size and metabolic activity of lesions caused by Echinococcus multilocularis and is therefore recommended for the initial assessment and follow-up of human alveolar echinococcosis (AE). The introduction of positron emission tomography/magnetic resonance imaging (PET/MRI) into clinical practice in affluent health care systems provides an alternative dual imaging modality, which has not yet been evaluated for AE. OBJECTIVE: Here, we describe the initial clinical experience with comparative PET/CT and PET/MR imaging in four human AE patients at an Austrian reference centre. RESULTS: PET/MR imaging showed comparable diagnostic capacity for liver lesions attributable to E. multilocularis infection, with a discrepancy only in the assessment of calcifications in one patient. Effective doses of radiation were 30.4-31 mSV for PET/CT, which were reduced in PET/MRI to the exposure of 18 F-FDG only (4.9-5.5 mSv). CONCLUSIONS: PET/MRI provides comparable diagnostic information for AE management. The reduction in radiation exposure compared to PET/CT may be of particular importance for children and young patients not amenable for curative surgery requiring repeated long-term follow-up with dual imaging modalities. Further studies are warranted to prospectively evaluate the potential of PET/MRI in the management of AE.


DONNÉES DE BASE: L'imagerie par la tomographie par émission de positrons au [18F]-2-fluoro-2-désoxy-D-glucose (18F-FDG)/tomodensitométrie (TEP/TDM) fournit des informations importantes sur la taille et l'activité métabolique des lésions causées par Echinococcus multilocularis et est donc recommandée pour l'évaluation initiale et le suivi de l'échinococcose alvéolaire (EA) humaine. L'introduction de la tomographie par émission de positons/imagerie par résonance magnétique (TEP/IRM) dans la pratique clinique des systèmes de soins de santé aisés offre une alternative de modalité d'imagerie double, qui n'a pas encore été évaluée pour l'EA. OBJECTIF: Nous décrivons ici l'expérience clinique initiale comparant les imageries TEP/TDM et TEP/IRM chez quatre patients humains atteints d'EA dans un centre de référence autrichien. RÉSULTATS: L'imagerie TEP/IRM a montré une capacité de diagnostic comparable pour les lésions hépatiques imputables à une infection à E. multilocularis, avec une divergence uniquement lors de l'évaluation des calcifications chez un patient. Les doses efficaces de rayonnement étaient de 30,4 à 31 mSV pour la TEP/TDM, qui ont été réduites dans la TEP/IRM à une exposition au 18 F-FDG uniquement (4,9 à 5,5 mSv). CONCLUSIONS: La TEP/IRM fournit des informations de diagnostic comparables pour la prise en charge de l'EA. La réduction de l'exposition aux rayonnements comparée à la TEP/TDM pourrait avoir une importance particulière pour les enfants et les jeunes patients ne pouvant pas subir de chirurgie curative nécessitant un suivi répété à long terme avec des modalités de double imagerie. Des études supplémentaires sont nécessaires pour évaluer de manière prospective le potentiel de la TEP/IRM dans la prise en charge de l'EA.


Assuntos
Equinococose/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Idoso , Animais , Áustria , Feminino , Fluordesoxiglucose F18 , Humanos , Fígado/parasitologia , Masculino , Pessoa de Meia-Idade
18.
Eur Radiol ; 29(8): 4276-4285, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30635757

RESUMO

AIM: To assess if tumour grading based on dynamic [18F]FET positron emission tomography/magnetic resonance imaging (PET/MRI) studies is affected by different MRI-based attenuation correction (AC) methods. METHODS: Twenty-four patients with suspected brain tumours underwent dynamic [18F]FET-PET/MRI examinations and subsequent low-dose computed tomography (CT) scans of the head. The dynamic PET data was reconstructed using the following AC methods: standard Dixon-based AC and ultra-short echo time MRI-based AC (MR-AC) and a model-based AC approach. All data were reconstructed also using CT-based AC (reference). For all lesions and reconstructions, time-activity curves (TACs) and time to peak (TTP) were extracted using different region-of-interest (ROI) and volume-of-interest (VOI) definitions. According to the most common evaluation approaches, TACs were categorised into two or three distinct curve patterns. Changes in TTP and TAC patterns compared to PET using CT-based AC were reported. RESULTS: In the majority of cases, TAC patterns did not change. However, TAC pattern changes as well as changes in TTP were observed in up to 8% and 17% of the cases when using different MR-AC methods and ROI/VOI definitions, respectively. However, these changes in TTP and TAC pattern were attributed to different delineations of the ROIs/VOIs in PET corrected with different AC methods. CONCLUSION: PET/MRI using different MR-AC methods can be used for the assessment of TAC patterns in dynamic [18F]FET studies, as long as a meaningful delineation of the area of interest within the tumour is ensured. KEY POINTS: • PET/MRI using different MR-AC methods can be used for dynamic [18F]FET studies. • A meaningful segmentation of the area of interest needs to be ensured, mandating a visual validation of the delineation by an experienced reader.


Assuntos
Neoplasias Encefálicas/diagnóstico , Radioisótopos de Flúor/farmacologia , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
19.
Pediatr Blood Cancer ; 65(1)2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28771999

RESUMO

PURPOSE: About 10% of patients with neurofibromatosis type 1 (NF-1) develop malignant peripheral nerve sheath tumours (MPNST) mostly arising in plexiform neurofibroma (PN); 15% of MPNST arise in children and adolescents. 2-[18 F]fluoro-2-deoxy-d-glucose ([18 F]FDG)-PET (where PET is positron emission tomography) is a sensitive method in differentiating PN and MPNST in symptomatic patients with NF-1. This study assesses the value of [18 F]FDG-PET imaging in detecting malignant transformation in symptomatic and asymptomatic children with PN. METHODS: Forty-one patients with NF-1 and extensive PN underwent prospective [18 F]FDG imaging from 2003 to 2014. Thirty-two of the patients were asymptomatic. PET data, together with histological results and clinical course were re-evaluated retrospectively. Maximum standardised uptake values (SUVmax) and lesion-to-liver ratio were assessed. RESULTS: A total of 104 examinations were performed. Mean age at first PET was 13.5 years (2.6-22.6). Eight patients had at least one malignant lesion; four of these patients were asymptomatic. Two of four symptomatic patients died, while all patients with asymptomatic malignant lesions are alive. All malignant tumours could be identified by PET imaging in both symptomatic and asymptomatic patients. All lesions judged as benign by [18 F]FDG imaging and clinical judgment were either histologically benign if removed or remained clinically silent during follow-up. SUVmax of malignant and benign lesions overlapped, but no malignant lesion showed FDG uptake ≤3.15. Asymptomatic malignant lesions were detected with a sensitivity of 100%, a negative predictive value of 100% and a specificity of 45.1%. CONCLUSION: Malignant transformation of PN also occurs in asymptomatic children and adolescents. Detection of MPNST at early stages could increase the possibility of oncologically curative resections.


Assuntos
Fluordesoxiglucose F18/administração & dosagem , Neurofibroma Plexiforme/diagnóstico por imagem , Neurofibromatose 1/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Masculino
20.
J Nucl Cardiol ; 25(5): 1742-1756, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-28176255

RESUMO

BACKGROUND: Accurate quantification of plaque imaging using 18F-NaF PET requires partial volume correction (PVC). METHODS: PVC of PET data was implemented by the use of a local projection (LP) method. LP-based PVC was evaluated with an image quality (NEMA) and with a thorax phantom with "plaque-type" lesions of 18-36 mL. The validated PVC method was then applied to a cohort of 17 patients, each with at least one plaque in the carotid or ascending aortic arteries. In total, 51 calcified (HU > 110) and 16 non-calcified plaque lesions (HU < 110) were analyzed. The lesion-to-background ratio (LBR) and the relative change of LBR (ΔLBR) were measured on PET. RESULTS: Following PVC, LBR of the spheres (NEMA phantom) was within 10% of the original values. LBR of the thoracic lesions increased by 155% to 440% when the LP-PVC method was applied to the PET images. In patients, PVC increased the LBR in both calcified [mean = 78% (-8% to 227%)] and non-calcified plaques [mean = 41%, (-9%-104%)]. CONCLUSIONS: PVC helps to improve LBR of plaque-type lesions in both phantom studies and clinical patients. Better results were obtained when the PVC method was applied to images reconstructed with point spread function modeling.


Assuntos
Placa Aterosclerótica/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Adulto , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Radioisótopos de Flúor , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Fluoreto de Sódio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA