Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
ESC Heart Fail ; 8(4): 2968-2981, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33934536

RESUMO

AIMS: Failure of right ventricular (RV) function worsens outcome in pulmonary hypertension (PH). The adaptation of RV contractility to afterload, the RV-pulmonary artery (PA) coupling, is defined by the ratio of RV end-systolic to PA elastances (Ees/Ea). Using pressure-volume loop (PV-L) technique we aimed to identify an Ees/Ea cut-off predictive for overall survival and to assess hemodynamic and morphologic conditions for adapted RV function in secondary PH due to heart failure with reduced ejection fraction (HFREF). METHODS AND RESULTS: This post hoc analysis is based on 112 patients of the prospective Magdeburger Resynchronization Responder Trial. All patients underwent right and left heart echocardiography and a baseline PV-L and RV catheter measurement. A subgroup of patients (n = 50) without a pre-implanted cardiac device underwent magnetic resonance imaging at baseline. The analysis revealed that 0.68 is an optimal Ees/Ea cut-off (area under the curve: 0.697, P < 0.001) predictive for overall survival (median follow up = 4.7 years, Ees/Ea ≥ 0.68 vs. <0.68, log-rank 8.9, P = 0.003). In patients with PH (n = 76, 68%) multivariate Cox regression demonstrated the independent prognostic value of RV-Ees/Ea in PH patients (hazard ratio 0.2, P < 0.038). Patients without PH (n = 36, 32%) and those with PH but RV-Ees/Ea ≥ 0.68 showed comparable RV-Ees/Ea ratios (0.88 vs. 0.9, P = 0.39), RV size/function, and survival. In contrast, secondary PH with RV-PA coupling ratio Ees/Ea < 0.68 corresponded extremely close to cut-off values that define RV dilatation/remodelling (RV end-diastolic volume >160 mL, RV-mass/volume-ratio ≤0.37 g/mL) and dysfunction (right ventricular ejection fraction <38%, tricuspid annular plane systolic excursion <16 mm, fractional area change <42%, and stroke-volume/end-systolic volume ratio <0.59) and is associated with a dramatically increased short and medium-term all-cause mortality. Independent predictors of prognostically unfavourable RV-PA coupling (Ees/Ea < 0.68) in secondary PH were a pre-existent dilated RV [end-diastolic volume >171 mL, odds ratio (OR) 0.96, P = 0.021], high pulsatile load (PA compliance <2.3 mL/mmHg, OR 8.6, P = 0.003), and advanced systolic left heart failure (left ventricular ejection fraction <30%, OR 1.23, P = 0.028). CONCLUSIONS: The RV-PA coupling ratio Ees/Ea predicts overall survival in PH due to HFREF and is mainly affected by pulsatile load, RV remodelling, and left ventricular dysfunction. Prognostically favourable coupling (RV-Ees/Ea ≥ 0.68) in PH was associated with preserved RV size/function and mid-term survival, comparable with HFREF without PH.


Assuntos
Insuficiência Cardíaca , Hipertensão Pulmonar , Disfunção Ventricular Direita , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Prognóstico , Estudos Prospectivos , Volume Sistólico , Disfunção Ventricular Direita/diagnóstico , Disfunção Ventricular Direita/etiologia , Função Ventricular Esquerda , Função Ventricular Direita
2.
Cardiovasc Ultrasound ; 17(1): 12, 2019 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-31186001

RESUMO

BACKGROUND: A new zero-fluoroscopy technique for electrophysiology catheter navigation relying on intracardiac echocardiography (ICE) has been recently reported (Ice&ICE trial). We investigated potential differences in efficacy, safety or procedural performance between conventional fluoroscopy- and ICE-guided cryothermal ablation (CA) in symptomatic AVNRT patients. METHODS: Clinical and electrophysiological data of AVNRT patients included in the Ice&ICE trial (22 patients, 16 females; =zero-fluoroscopy group) were compared to those of consecutive AVNRT patients, who underwent fluoroscopy-guided CA (25 patients, 17 females; = fluoroscopy group) during the last 2 years in our institution. RESULTS: Slow pathway ablation or modulation was successful in all patients. Fluoroscopy time and radiation dose in the fluoroscopy group were 11.2 ± 9.0 min and 20.3 ± 16.2Gycm2, whereas no fluoroscopy was used in the opposite group (p <  0.001, respectively). EPS duration was not different between the groups (zero-fluoroscopy:101.6 ± 40.2 min, fluoroscopy:99.4 ± 37.2 min, p = n.s.). Catheter placement time was significantly shorter in the fluoroscopy group (2.2 ± 1.6 min vs. 12.0 ± 7.5 min, p <  0.05), whereas cryo-application duration (from the first cryo-mapping to the last CA) was significantly shorter in the zero-fluoroscopy group (27.5 ± 37.0 min vs. 38.1 ± 33.9 min, p <  0.05). Mean cryo-mapping and CA applications were numerically lower in the zero-fluoroscopy group (CM:7.5 ± 5.7 vs. 8.8 ± 6.2; CA:3.1 ± 1.7 vs. 3.2 ± 2.0, p = n.s.). No major adverse events occurred in both groups. After 15.0 ± 4.2 months, arrhythmia recurrence was not different between the groups (4.5% vs. 8.0%, p = n.s.). CONCLUSIONS: Zero-fluoroscopy ICE-guided EP catheter navigation shows comparable efficacy and safety to fluoroscopic guidance during CA in AVNRT patients. ICE visualization of catheters and endocardial structures within the triangle of Koch shortens the cryo-application duration, though time needed for catheter placement is longer, when compared with conventional fluoroscopic guidance, which results in similar mean EPS duration with both navigation techniques. TRIAL REGISTRATION: (German Clinical Trials Register ID: DRKS00011360 ; Registration Date 14.12.2016).


Assuntos
Cateterismo Cardíaco/métodos , Criocirurgia/métodos , Ecocardiografia/métodos , Procedimentos Endovasculares/métodos , Fluoroscopia/métodos , Cirurgia Assistida por Computador/métodos , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Eletrocardiografia , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Pericárdio , Reprodutibilidade dos Testes , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Ultrassonografia de Intervenção/métodos
3.
J Cardiol ; 72(2): 135-139, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29544658

RESUMO

BACKGROUND: Implantable cardioverter/defibrillator (ICD) shocks can cause myocardial injury, contributing to the progression of the underlying heart disease. The aim was to evaluate whether internal electrical cardioversion (int-CV) via the ICD or conventional external CV (ext-CV) of persistent atrial fibrillation (AF) in heart failure (HF) patients induces myocardial injury and initiates inflammation. METHODS AND RESULTS: A total of 115 HF patients with an ejection fraction between 20% and 45% were prospectively enrolled. Fifty-one patients were excluded due to failure of electrical CV at the first attempt as well as early relapse of AF within 8h after CV. The int-CV group consisted of 22 and the ext-CV group of 42 patients. Baseline values of high sensitive troponin T (hsTnT), interleukin (IL)-6, and C-reactive protein (CRP) did not differ significantly in both groups, whereas baseline N-terminal pro B-type natriuretic peptide (NT-pro BNP) was significantly lower in the ext-CV group. Eight hours after CV, the level of hsTnT increased significantly in the int-CV group, whereas no significant change was observed in the ext-CV group. Furthermore, CV significantly increased IL-6 and CRP in the int-CV group, whereas an insignificant increase could be documented in the ext-CV group. Due to electrical CV in both groups, the NT-pro BNP levels significantly declined in approximately the same content (int-CV 29% vs. ext-CV 36%). CONCLUSIONS: The significant increase in hsTnT, IL-6, and CRP in patients who underwent int-CV compared to those undergoing ext-CV may suggest that int-CV causes significant myocardial damage and induces systemic inflammation.


Assuntos
Fibrilação Atrial/terapia , Cardioversão Elétrica/métodos , Insuficiência Cardíaca/terapia , Idoso , Fibrilação Atrial/sangue , Proteína C-Reativa/análise , Desfibriladores Implantáveis , Feminino , Humanos , Interleucina-6/sangue , Masculino , Pessoa de Meia-Idade , Miocárdio/metabolismo , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Troponina T/sangue
4.
J Cardiovasc Electrophysiol ; 29(1): 160-166, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28960632

RESUMO

INTRODUCTION: Stochastic damage of the ionizing radiation to both patients and medical staff is a drawback of fluoroscopic guidance during catheter ablation of cardiac arrhythmias. Therefore, emerging zero-fluoroscopy catheter-guidance techniques are of great interest. METHODS AND RESULTS: We investigated, in a prospective pilot study, the feasibility and safety of the cryothermal (CA) slow-pathway ablation in patients with symptomatic atrioventricular-nodal-re-entry-tachycardia (AVNRT) using solely intracardiac echocardiography (ICE) for endovascular and endocardial catheter visualization. Twenty-five consecutive patients (mean age 55.6 ± 12.0 years, 17 female) with ECG-documentation or symptoms suggesting AVNRT underwent an electrophysiology study (EPS) in our laboratory utilizing ICE for catheter navigation. Supraventricular tachycardia was inducible in 23 (92%) patients; AVNRT was confirmed by appropriate stimulation maneuvers in 20 (80%) patients. All EPS in the AVNRT subgroup could be accomplished without need for fluoroscopy, relying solely on ICE-guidance. CA guided by anatomical location and slow-pathway potentials was successful in all patients, median cryo-mappings = 6 (IQR:3-10), median cryo-ablations = 2 (IQR:1-3). Fluoroscopy was used to facilitate the trans-septal puncture and localization of the ablation substrate in the remaining 3 patients (one focal atrial tachycardia and two atrioventricular-re-entry-tachycardias). Mean EPS duration in the AVNRT subgroup was 99.8 ± 39.6 minutes, ICE guided catheter placement 11.9 ± 5.8 minutes, time needed for diagnostic evaluation 27.1 ± 10.8 minutes, and cryo-application duration 26.3 ± 30.8 minutes. CONCLUSIONS: ICE-guided zero-fluoroscopy CA in AVNRT patients is feasible and safe. Real-time visualization of the true endovascular borders and cardiac structures allow for safe catheter navigation during the ICE-guided EPS and might be an alternative to visualization technologies using geometry reconstructions.


Assuntos
Cateterismo Cardíaco , Criocirurgia , Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Supraventricular/cirurgia , Ultrassonografia de Intervenção/métodos , Potenciais de Ação , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Estimulação Cardíaca Artificial , Criocirurgia/efeitos adversos , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
5.
BMC Cardiovasc Disord ; 17(1): 294, 2017 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-29233088

RESUMO

BACKGROUND: Interventional closure of the left atrial appendage (LAA) in patients with non-valvular atrial fibrillation, high thromboembolic and bleeding risk or bleeding history is an alternative therapeutic strategy to oral anticoagulation. It is not known if the exclusion of the LAA from the blood circulation affects the left atrial volume (LAV) and consequently its prognostic value or the circulatory performance of the heart in humans. METHODS: We aimed to prospectively assess potential changes in baseline LAV, left ventricular ejection fraction (LVEF), NT-proBNP-level and the covered distance in the 6-min walk-test 6 weeks and 6 months after LAA closure with the WATCHMAN™ device. We used serial 3-dimensional transthoracic and transesophageal echocardiography to assess LAV, residual interatrial shunt and device performance in 58 consecutive patients with successful LAA closure. RESULTS: Accurate 3D-echocardiographic data for LAV measurements were evaluable for 51 (91%) patients. Maximum LAV (LAVmax) at baseline was 102.8 ± 30.8 ml and increased significantly to 107.7 ± 32.8 ml after 6 weeks (p < 0.01) and 113.5 ± 34.2 ml after 6 months (p < 0.01). Minimal LAV (LAVmin) increased from 76.9 ± 29.5 ml at baseline to 81.8 ± 30.2 ml after 45 days (p < 0.01) and 82.1 ± 33.3 ml after 6 months (p < 0.01). Similarly, their indexes to BSA (LAVImax and LAVImin) increased significantly, as well. Patients without a residual left-to-right interatrial shunt showed a significantly higher increase in LAVmax or LAVmin. Baseline LVEF, NT-proBNP-level or the distance covered at the 6-min walk test did not significantly change 6 weeks or 6 months after LAA closure. CONCLUSIONS: LAVmax and LAVmin increase significantly after interventional LAA closure. LA enlargement does not correlate with clinical progression of heart failure. Persistent left-to-right interatrial shunt counteracts the LA enlargement. A reduced LA compliance after exclusion of the LAA from the blood circulation with consecutive increase in LA pressure may be a potential cause of LA enlargement and warrants further investigation. TRIAL REGISTRATION: German Clinical Trials Register ID: DRKS00010768 ; Registration Date 07.07.2016.


Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Remodelamento Atrial , Cateterismo Cardíaco/instrumentação , Hemodinâmica , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Biomarcadores/sangue , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Tolerância ao Exercício , Feminino , Humanos , Masculino , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Estudos Prospectivos , Recuperação de Função Fisiológica , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda , Teste de Caminhada
6.
Pacing Clin Electrophysiol ; 33(2): e17-9, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19821937

RESUMO

Irregular sensing by triple counting of wide QRS complexes resulted in inappropriate shocks in a patient with a biventricular implantable cardioverter defibrillator (ICD): A 66-year-old male patient with ischemic cardiomyopathy, left bundle branch block, and impaired left ventricular function received a biventricular ICD for optimal therapy of heart failure (CHF). Two years after implantation, the patient experienced recurrent unexpected ICD shocks without clinical symptoms of malignant tachyarrhythmia, or worsened CHF. The patient's condition rapidly worsened, with progressive cardiogenic shock and electrical-mechanical dissociation. After unsuccessful resuscitation of the patient the interrogation of the ICD showed an initial triple counting of extremely wide and fragmented QRS complexes with inappropriate shocks.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Falha de Prótese , Taquicardia/etiologia , Bloqueio de Ramo/fisiopatologia , Cardiomiopatias/fisiopatologia , Evolução Fatal , Feminino , Humanos , Masculino , Função Ventricular Esquerda
7.
Clin Res Cardiol ; 95(2): 119-21, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16598522

RESUMO

A single coronary artery is a rare congenital anomaly with an incidence of 0.02-0.04%. We report on a 65-year-old male presenting with atypical chest pain and a history of hypertension and hypercholesterinemia, having diagnosed a very rare variant of a single coronary artery arising from the right sinus of Valsalva continuing as circumflex coronary artery (LCX) and thereafter as left anterior descending artery (LAD). Because the patient was asymptomatic on antiischemic medication and had a proposed relative benign course, we recommended medical treatment without coronary artery bypass surgery, and the patient has been in fine condition up to now (11 months after angiography).


Assuntos
Anomalias dos Vasos Coronários/diagnóstico por imagem , Seio Aórtico/anormalidades , Angiografia Coronária , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA