Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ann Thorac Surg ; 71(3 Suppl): S150-5; discussion S183-4, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11265851

RESUMO

BACKGROUND: Two modifications of the surgical implantation protocol for the Penn State Total Artificial Heart (ETAH) were evaluated: Phrenic nerve ischemia was prevented by minimizing dissection and traction; and hemostasis was augmented and ETAH cuff anastomoses reinforced by using fibrin glue. METHODS: Thirteen Holstein calves underwent orthotopic surgical implantation of the Penn State ETAH between February 1998 and August 2000. Mean hemodynamic and laboratory chemistry variables from the first postoperative week were compared between calves receiving the original (n = 7) and modified (n = 6) protocol. RESULTS: Calves assigned to the modified protocol displayed an improvement in the Po2/FiO2 ratio compared to original (419.4 +/- 17.5 vs 336.3 +/- 35.4, respectively; p = 0.05). All additional parameters were equivalent between groups. The percent survival of animals receiving the modified protocol at 2, 4, and 12 weeks was higher than that of animals that underwent the original protocol. Original-protocol calf deaths consisting of hemothorax (n = 3), and respiratory failure (n = 1) were prevented in the modified protocol. CONCLUSIONS: Our results suggest that manipulations in surgical protocol may promote increased survival in calves implanted with the Penn State ETAH.


Assuntos
Coração Artificial , Implantação de Prótese/métodos , Animais , Bovinos , Causas de Morte , Coração Artificial/efeitos adversos , Hemodinâmica , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Implantação de Prótese/efeitos adversos , Taxa de Sobrevida
2.
Artif Organs ; 22(1): 87-94, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9456234

RESUMO

In vivo characterization studies were performed to compare the dynamic in vivo performance of the Penn State/3M Health Care electric total artificial heart to existing in vitro data. Fully implanted systems were utilized including the artificial heart, controller, backup batteries, compliance chamber, and transcutaneous energy transmission. Catheters were implanted to measure central venous pressure (CVP), left atrial pressure (LAP), right atrial pressure (RAP), pulmonary artery pressure (PAP), and aortic pressure (AoP). Cardiac output (CO) was determined from the implanted controller, and systemic vascular resistance (SVR) was calculated. Steady state data were collected for each animal along with data regarding the transient responses to changes in preload and afterload. Preload was manipulated through volume changes. Afterload changes were accomplished through vasoactive agents. Increased preload caused little change in cardiac output because the pump output was nearly maximum at baseline. LAP, AoP, and SVR increased with increasing RAP. Decreased preload caused a reduction in CO, LAP, and SVR. Afterload increase resulted in a slight decrease in flow and an increase in system power and SVR. Afterload reduction was accompanied by a decrease in preload and a concomitant reduction in flow. Overall, the system response was similar to the response observed in vitro.


Assuntos
Coração Artificial , Animais , Pressão Sanguínea/fisiologia , Débito Cardíaco/fisiologia , Bovinos , Hematócrito , Testes de Função Renal , Testes de Função Hepática , Pressão Propulsora Pulmonar/fisiologia , Análise de Sobrevida , Resistência Vascular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA