Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Photodiagnosis Photodyn Ther ; 38: 102785, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35231616

RESUMO

Fourier-transform infrared (FT-IR) and Raman spectroscopy are being widely applied as sensor-based techniques in oncology, particularly in the diagnosis of brain cancers and their subtypes. Overtime, these techniques have become more sensitive; and, accuracies of over 90% have been observed in several studies. This is indication of their potential for clinical implementation. Herein, we present a mini-review by revisiting some fundamentals of FT-IR and Raman spectroscopy along with their applications towards brain cancer detection in the literature.


Assuntos
Neoplasias Encefálicas , Fotoquimioterapia , Neoplasias Encefálicas/diagnóstico , Cabeça , Humanos , Fotoquimioterapia/métodos , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Análise Espectral Raman/métodos
2.
Spectrochim Acta A Mol Biomol Spectrosc ; 273: 121018, 2022 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-35189493

RESUMO

Meningiomas remains a clinical dilemma. They are the commonest "benign" types of brain tumours and, although being typically benign, they are divided into three WHO grades categories (I, II and III) which are associated with the tumour growth rate and likelihood of recurrence. Recurrence depends on extend of surgery as well as histopathological diagnosis. There is a marked variation amongst surgeons in the follow-up arrangements for their patients even within the same unit which has a significant clinical, and financial implication. Knowing the tumour grade rapidly is an important factor to predict surgical outcomes and adequate patient treatment. Clinical follow up sometimes is haphazard and not based on clear evidence. Spectrochemical techniques are a powerful tool for cancer diagnostics. Raman hyperspectral imaging is able to generate spatially-distributed spectrochemical signatures with great sensitivity. Using this technique, 95 brain tissue samples (66 meningiomas WHO grade I, 24 meningiomas WHO grade II and 5 meningiomas that reoccurred) were analysed in order to discriminate grade I and grade II samples. Newly-developed three-dimensional discriminant analysis algorithms were used to process the hyperspectral imaging data in a 3D fashion. Three-dimensional principal component analysis quadratic discriminant analysis (3D-PCA-QDA) was able to distinguish grade I and grade II meningioma samples with 96% test accuracy (100% sensitivity and 95% specificity). This technique is here shown to be a high-throughput, reagent-free, non-destructive, and can give accurate predictive information regarding the meningioma tumour grade, hence, having enormous clinical potential with regards to being developed for intra-operative real-time assessment of disease.


Assuntos
Neoplasias Encefálicas , Neoplasias Meníngeas , Meningioma , Neoplasias Encefálicas/diagnóstico por imagem , Criança , Análise Discriminante , Humanos , Imageamento Hiperespectral , Neoplasias Meníngeas/diagnóstico por imagem , Neoplasias Meníngeas/patologia , Meningioma/diagnóstico por imagem , Meningioma/patologia
3.
J Plast Reconstr Aesthet Surg ; 69(1): 101-7, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26507862

RESUMO

In this study, radiographic assessment was performed to find out the effectiveness of bone regeneration following the application of recombinant human bone morphogenetic protein 7 (rhBMP-7) for the reconstruction of alveolar cleft defects in 11 cases: nine unilateral and two bilateral alveolar clefs. Reconstruction of the alveolar cleft was performed by using 3.5 mg of rhBMP-7 (Osigraft OP1) on a type I collagen carrier. Radiographs were taken 6 months post operation using a Gendex Intraoral Unit with Agfa Dentus M2 Comfort occlusal film. The amount of bony infill was graded on a Kindelan four-point scale. The patients were followed up for an average of 6.6 years. Based on the radiographic analysis, eight out of the nine unilateral alveolar cleft cases received a score of grade I and one patient had a grade II score, using the Kindelan scale. In the two bilateral alveolar clefts, only one side had bone formation. The radiographic appearance showed a normal trabecular pattern similar to the adjacent bone. Thus, rhBMP-7 was radiographically and clinically successful in regenerating the bone at the alveolar cleft which resulted in shortening of the operation time, absence of donor-site morbidity and a shorter hospital stay. The promising results of this preliminary study should encourage a phase II trial to compare bone grafts with BMP for the reconstruction of alveolar defects.


Assuntos
Aumento do Rebordo Alveolar/métodos , Proteína Morfogenética Óssea 7/farmacologia , Fissura Palatina/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Criança , Fenda Labial/cirurgia , Feminino , Humanos , Masculino , Proteínas Recombinantes
4.
Med Biol Eng Comput ; 54(2-3): 475-84, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26133282

RESUMO

A multi-view three-dimensional stereophotogrammetry system was developed to capture 3D shape of breasts for breast cancer patients. The patients had received immediate unilateral breast reconstruction after mastectomy by the extended latissimus dorsi flap and without contralateral surgery. In order to capture the whole breast shape including the inframammary fold, the patients were introduced to the imaging room and leaned over the imaging rig to open up the inframammary fold and to expose the entire area of each breast. The imaging system consisted of eight high-resolution ([Formula: see text] pixels) digital cameras and four flash units. The cameras were arranged in four stereo pairs from four different view angles to cover the whole surface of the breasts. The system calibration was carried out ahead of every capture session, and the stereo images were matched to generate four range images to be integrated using an elastic model proposed. A watertight breast mesh model was reconstructed to measure the volume of the breast captured. The accuracy of using the developed multi-view stereophotogrammetry system for breast volume measurement was 11.12cc with SEM 7.74cc, comparing to the measurements of the water displacement method. It was concluded that the 3D stereophotogrammetry image system developed was more reliable than the method of water displacement.


Assuntos
Mamoplastia/métodos , Mastectomia/métodos , Fotogrametria/métodos , Artefatos , Calibragem , Feminino , Humanos , Imageamento Tridimensional
5.
J Plast Reconstr Aesthet Surg ; 66(11): 1551-6, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23849983

RESUMO

INTRODUCTION: 3D imaging of the breast has recently emerged as a new method for objective breast assessment. However in the ptotic breast shape, which is seen in the majority of cases, the sub-mammary fold remains obscured when the breast is captured in an upright body posture. METHOD: A self-designed positioning frame for 3D breast capture was utilized as a safe positioning aide. Six volunteers stood on an adjustable standing step, leaning with the hips against a soft-coated hip roll while stretching forward with the upper body extending to a nearly horizontal position and reaching with the arms forward resting on arm pads. 3D breast capture was conducted simultaneously with eight digital cameras that were positioned to capture the right, left, anterior and inferior views of the breast. Capture was repeated three times at different time intervals. The reproducibility of the pose, captures and 3D measurements were investigated. RESULTS: The custom-made positioning frame allowed the complete capture of the breast, even in the ptotic shapes. The investigation of the reproducibility revealed a 6.25% standard deviation of the pose; this being the variable with the smallest variation compared with the variations obtained for reproducibility of captures and 3D measurements. The difference between the first and second pose was not significant at 95% CI (-77.3; 11.9), p = 0.119. CONCLUSION: The presented system used a self-designed positioning frame, by which the complete capture of the ptotic breast in near horizontal upper body posture was achieved. Reproducibility of the pose for 3D capture was satisfactory.


Assuntos
Mama/anatomia & histologia , Imageamento Tridimensional , Fotografação/instrumentação , Postura , Software , Envelhecimento , Feminino , Humanos , Reprodutibilidade dos Testes
6.
J Plast Reconstr Aesthet Surg ; 66(5): 634-9, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23402935

RESUMO

BACKGROUND: To date breast assessment has been conducted mainly subjectively. However lately validated objective three-dimensional (3D) imaging was developed. The study aimed to assess breast reconstruction subjectively and objectively and conduct a comparison. METHODS: In forty-four patients after immediate unilateral breast reconstruction with solely the extended latissimus dorsi flap the breast was captured by validated 3D imaging method and standardized 2D photography. Breast symmetry was subjectively evaluated by six experts who applied the Harris score giving a mark of 1-4 for a poor to excellent result. An error study was conducted by examination of the intra and inter-observer agreement and agreement on controls. By Procrustes analysis an objective asymmetry score was obtained and compared to the subjective assessment. RESULTS: The subjective assessment showed that the inter-observer agreement was good or substantial (p-value: <0.0001). There was moderate agreement on the controls (p-value: <0.0001) and fair (p-values: 0.159, 0.134, 0.099) to substantial (p-value: 0.005) intra-observer agreement. The objective assessment revealed that the reconstructed breast showed a significantly smaller volume compared to the opposite side and that the average asymmetry score was 0.052, ranging from 0.019 to 0.136. When comparing the subjective and objective method the relationship between the two scores was highly significant. CONCLUSION: Subjective breast assessment lacked accuracy and reproducibility. This was the first error study of subjective breast assessment versus an objective validated 3D imaging method based on true 3D parameters. The substantial agreement between established subjective breast assessment and new validated objective method supported the value of the later and we expect its future role to expand.


Assuntos
Mama/cirurgia , Imageamento Tridimensional/instrumentação , Mamoplastia/métodos , Fotografação/instrumentação , Retalhos Cirúrgicos , Desenho de Equipamento , Feminino , Humanos , Reprodutibilidade dos Testes
7.
J Plast Reconstr Aesthet Surg ; 65(12): e332-7, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22766492

RESUMO

BACKGROUND: Errors derive from the variability seen in the repeat volume measurements for a particular individual. The aim of this study was to evaluate the variation and errors of a three-dimensional (3D) multiple stereo camera system for objective breast assessment. It was also investigated whether there was any correlation between these errors and the size of the breast. METHODS: A prototype eight camera multiple stereophotogrammetry system was utilized. The volumes of nine plaster breast models were determined by 3D imaging and the correlation between the size of the models and the variability of the measurements was investigated after ten repeats. The breasts of six live volunteers were examined following a specific protocol. The breasts were captured six times, three times each on two different occasions; from each breast capture a three-dimensional model was built and the breast volume was measured three times with breast analysis tool (BAT) software. This allowed for an assessment of the variability introduced at each stage of the measurement procedure. The correlation between the size of the breast and the variability of the measurements was investigated. Results of volume measurements by water displacement method, repeated ten times with the plaster models and six times with the live models, were used for comparison. RESULTS: The correlation between the size of the plaster models and the variability of the measurements revealed a significant correlation (p = 0.033), indicating that the larger the model, the more variable were the results. The correlation between the size of the breasts in the live models and the variability of the results revealed a non-significant correlation (p = 0.342), but there was a visible trend that the larger breasts showed more variable results. The average variation in the repeated measurements on each individual was found to be 32.95 cc across the two different poses, 19.43 cc across the various captures, and 28.32 across the different volume calculations with the BAT software. The error is less than what is clinically visible with the human eye, which is about 50 cc variation in volume by subjective assessment. As a proportion of the mean volume, namely 6.9%, 4.0% and 5.9% respectably, the values are small and indicate that the reproducibility of the system is good. CONCLUSION: The 3D imaging system using multiple stereo cameras revealed a positive correlation between the size of plaster models and the breasts of live models and the reproducibility of the measurements, indicating that the variation was higher for the larger sizes. The relationship was significant in the plaster models but not in the live models, although a trend was observed. The assessment of the variation and errors of the system was part of the necessary procedure that should be considered for the validation of any new measurement technology for breast assessment.


Assuntos
Mama/anatomia & histologia , Imageamento Tridimensional/instrumentação , Fotogrametria/instrumentação , Adulto , Erros de Diagnóstico , Feminino , Humanos , Modelos Lineares , Imagens de Fantasmas , Reprodutibilidade dos Testes
8.
J Plast Reconstr Aesthet Surg ; 65(9): 1209-15, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22525253

RESUMO

BACKGROUND: The latissimus dorsi muscle flap is a common method for the reconstruction of the breast following mastectomy. The study aimed to assess the quality of this reconstruction using a three-dimensional (3D) imaging method. The null hypothesis was that there was no difference in volume between the reconstructed breast and the opposite side. METHODS: This study was conducted in forty-four patients who had had immediate unilateral breast reconstruction by latissimus dorsi muscle flap. The breast was captured using the 3D imaging system. Ten landmarks were digitised on the 3D images. The volume of each breast was measured by the application of Breast Analysis Tool software. The symmetry of the breast was measured using Procrustes analysis. The impact of breast position, orientation, size and intrinsic shape on the overall breast asymmetry was investigated. RESULTS: The null hypothesis was rejected. The reconstructed breast showed a significantly smaller volume when compared to the opposite side, p < 0.0001, a mean difference of 176.8 cc and 95% CI (103.5, 250.0). The shape and the position of the reconstructed breast were the main contributing factors to the measured asymmetry score. CONCLUSIONS: 3D imaging was efficient in evaluating the outcome of breast surgery. The latissimus dorsi muscle flap on its own for breast reconstruction did not restore the volume and shape of the breast fully lost due to complete mastectomy. The modification of this method and the selection of other or additional surgical techniques for breast reconstruction should be considered. The asymmetry analysis through reflection and Procrustes matching was a useful method for the objective shape analysis of the female breast and presented a new approach for breast shape assessment. The intrinsic breast shape and the positioning of the breast were major components of postoperative breast asymmetry. The reconstructed breast was smaller overall than the un-operated breast at a significant level when assessing the breast volume using the surface area. 3D imaging by multiple stereophotogrammetry was a useful tool for volume measurements, shape analysis and the evaluation of symmetry.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/cirurgia , Imageamento Tridimensional , Mamoplastia/métodos , Retalhos Cirúrgicos , Adulto , Pontos de Referência Anatômicos , Estudos de Coortes , Feminino , Seguimentos , Rejeição de Enxerto , Sobrevivência de Enxerto , Humanos , Interpretação de Imagem Assistida por Computador , Mastectomia/métodos , Pessoa de Meia-Idade , Músculo Esquelético/transplante , Fotogrametria , Cuidados Pós-Operatórios/métodos , Estudos Retrospectivos , Resultado do Tratamento , Reino Unido
9.
J Plast Reconstr Aesthet Surg ; 64(5): 577-82, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-20947459

RESUMO

BACKGROUND: The aim of this study was to evaluate the validity of a three-dimensional (3D) multiple stereo camera system for objective breast assessment. METHODS: A multiple stereo camera system, which consisted of four pods and eight cameras, two cameras on each pod, developed by Glasgow University, was used. Nine specially shaped plaster breast models were captured once, 3Dmodels were constructed and the volume of each plaster model was measured 10 times by the breast analysis tool (BAT) software. A comparison was conducted with water displacement method, and measurements were repeated 10 times. The breast of six live volunteers was captured six times; from each breast capture, a 3D model was constructed and the volume was measured with BAT software. Breast volume assessment by the water displacement method was repeated six times. RESULTS: In all plaster casts, the discrepancies in volume measurements between 3D imaging and water displacement methods did not exceed 40 cc. The overall mean relative difference was 5%. The differences of the two methods were not significant at p = 0.189, overall mean difference: 11.1 cc and 95% confidence interval (CI) was (-6.732, 28.976). In the live models, the differences in breast volume measurements between the 3D imaging and water displacement methods were significant at p ≤ 0.017, overall mean difference: 207.05 cc and 95% CI (56.12, 357.98). Measurements by 3D imaging were consistently smaller. In the live models, 3D imaging overall was a more reproducible method for measuring breast volume than the water displacement method with a standard deviation of 36 units cc(-1) and 62.6 units cc(-1), respectively. CONCLUSIONS: The 3D breast imaging system using multiple stereo cameras was accurate for measuring the volumes of breast-shaped plaster models, and it was more reproducible than the water displacement method in live models. 3D imaging is a reliable method for the comparative assessment of breast volume.


Assuntos
Mama/anatomia & histologia , Imageamento Tridimensional/instrumentação , Modelos Anatômicos , Desenho de Equipamento , Feminino , Humanos , Fotogrametria/instrumentação , Reprodutibilidade dos Testes
10.
J Craniomaxillofac Surg ; 31(1): 40-1, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12553925

RESUMO

A simple method of measuring the volume of cortico-cancellous bone grafts is described. The method is quick and reliable. Only materials readily available in the operation theatre are used.


Assuntos
Transplante Ósseo/patologia , Humanos , Procedimentos de Cirurgia Plástica/instrumentação , Reprodutibilidade dos Testes , Cloreto de Sódio , Seringas , Temperatura , Pesos e Medidas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA