Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
AJR Am J Roentgenol ; 166(5): 1173-9, 1996 May.
Artigo em Inglês | MEDLINE | ID: mdl-8615265

RESUMO

OBJECTIVE: The purpose of our study was to report long-term (more than 2 years of follow-up) angiographic patency after self-expandable stent implantation in the iliac artery and to identify patient- or procedure-related prognostic factors of angiographic patency. SUBJECTS AND METHODS: Ninety-five consecutive patients (101 arteries) underwent Wallstent implantation to treat claudication (n=95 limbs), rest pain (n=2), and nonhealing ulcer (n=3). Another patient was asymptomatic but was treated for acute occlusion of the iliac artery after coronary angioplasty. After implantation of self-expandable stents, we followed up by examining clinical and angiographic records at 6 months, 1 year, and annually thereafter. The Kaplan-Meier survival curve was used to determine primary and secondary patency rates. Primary patency was that achieved after the initial procedure only. Secondary patency was defined as that achieved after one or more successful additional percutaneous procedures within the stent or beyond the stent. Multivariate analysis using the Cox proportional hazard model was performed to identify predictive factors of angiographic failure, defined as restenosis of 50% or greater or occlusion. RESULTS: Four-year patency rates of 61% (primary) and 86% (secondary) were found (mean follow-up, 29 months). The following five factors were associated with long-term angiographic failure: occlusion of the superficial femoral artery (relative hazard = 5.21), absence of hypertension (relative hazard = 4.85), a stent diameter of less than 8 mm (relative hazard = 4.45), two or more stents implanted (relative hazard = 3.56), and current tobacco consumption (relative hazard = 2.46). CONCLUSION: Improved patency rates may be obtained by selecting patients for Wallstent implantation in the iliac artery based on five factors shown to be prognostically important.


Assuntos
Arteriopatias Oclusivas/terapia , Artéria Ilíaca , Stents , Adulto , Angioplastia com Balão , Arteriopatias Oclusivas/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Artéria Ilíaca/diagnóstico por imagem , Tábuas de Vida , Masculino , Pessoa de Meia-Idade , Prognóstico , Modelos de Riscos Proporcionais , Radiografia , Stents/estatística & dados numéricos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
2.
J Vasc Interv Radiol ; 7(3): 335-42, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8761808

RESUMO

PURPOSE: To report midterm follow-up after implantation of covered stents for hemodialysis access. PATIENTS AND METHODS: Over a 2-year period, a Cragg Endopro stent was placed in 14 patients (mean age, 66.6 years +/- 15) to treat angioplasty-induced ruptures (n = 3), pseudoaneurysm (n = 1), postangioplasty residual stenosis (n = 2), and early restenosis (n = 8, four of them in a Wallstent). RESULTS: Initial placement was successful in all cases. A clinical inflammatory reaction was observed in all three cases of placement in the forearm. When the covered stent was placed in a stenotic vessel, restenosis always occurred within 6 months. Primary and secondary patencies were 28.5% +/- 13.9 and 67.8% +/- 14.5, respectively, at 6 months. Covered stents were of undoubtable benefit in one case of rupture after Wallstent failure and in one case of restenosis in a Wallstent. CONCLUSION: Covered Cragg stents are effective in controlling angioplasty- induced rupture and sometimes for maintaining patency after restenosis in a Wallstent. They do not prevent restenosis and are responsible for an inflammatory reaction of unknown origin and long-term effect.


Assuntos
Derivação Arteriovenosa Cirúrgica/instrumentação , Falência Renal Crônica/terapia , Diálise Renal , Stents , Idoso , Idoso de 80 Anos ou mais , Angiografia , Falha de Equipamento , Feminino , Oclusão de Enxerto Vascular/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Reoperação , Propriedades de Superfície
3.
Cathet Cardiovasc Diagn ; 28(4): 339-41, 1993 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8462085

RESUMO

A case of traumatic arteriovenous fistula and false aneurysm of the internal mammary artery was encountered following sternal wire insertion during cardiac surgery. The diagnosis was suspected by echo-doppler and confirmed by arteriography allowing percutaneous embolization using cyanoacrylate in the same setting.


Assuntos
Falso Aneurisma/terapia , Fístula Arteriovenosa/terapia , Fios Ortopédicos , Embolização Terapêutica , Artéria Torácica Interna/lesões , Complicações Pós-Operatórias/terapia , Falso Aneurisma/etiologia , Fístula Arteriovenosa/etiologia , Embucrilato , Feminino , Humanos , Anastomose de Artéria Torácica Interna-Coronária , Pessoa de Meia-Idade , Esterno/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA