Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Catheter Cardiovasc Interv ; 99(6): 1807-1816, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35066988

RESUMO

OBJECTIVES: To compare all-cause mortality in patients with mitral annulus calcification (MAC) and severe mitral valve dysfunction (MVD) who received standard mitral intervention versus no intervention. BACKGROUND: Patients with MAC often have high surgical risk due to advanced age, comorbidities, and technical challenges related to calcium. The impact of a mitral intervention on outcomes of patients with MAC and severe MVD is not well known. METHODS: Retrospective review of patients with MAC by transthoracic echocardiography (TTE) in 2015 at a single institution. Patients with severe mitral stenosis (MS) or regurgitation (MR) were analyzed and stratified into two groups: surgical or transcatheter intervention performed <1 year after the index TTE, and no or later intervention. The primary endpoint was all-cause mortality. RESULTS: Of 5502 patients with MAC, 357 had severe MVD (MS = 27%, MR = 73%). Of those, 108 underwent mitral intervention (surgery = 87; transcatheter = 21). They were younger (73 ± 11 vs. 76 ± 11 years, p < 0.01) and less frequently had cardiovascular diseases compared with no-intervention. Frequency in women was similar (45% vs. 50%, p = 0.44). During median follow-up of 3.2 years, the intervention group had higher estimated survival than those without intervention (80% vs. 72% at 1 year and 55% vs. 35% at 4 year, p < 0.01). Adjusted for age, eGFR, LVEF < 50%, and pulmonary hypertension, mitral intervention was an independent predictor of lower mortality (hazard ratio = 0.66, 95% confidence interval 0.43-0.99, p = 0.046). CONCLUSION: Patients with MAC and severe MVD who underwent mitral intervention <1 year from index TTE had lower mortality than those without intervention. Mitral intervention was independently associated with lower mortality.


Assuntos
Calcinose , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Feminino , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/complicações , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/terapia , Estudos Retrospectivos , Resultado do Tratamento
2.
Int J Cardiol Heart Vasc ; 33: 100765, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33889711

RESUMO

AIMS: Percutaneous mitral balloon valvotomy PMBV is an acceptable alternative to Mitral valve surgery for patients with mitral stenosis. The purpose of this study was to explore the immediate results of PMBV with respect to echocardiographic changes, outcomes, and complications, using a meta-analysis approach. METHODS: MEDLINE, and EMBASE databases were searched (01/2012 to 10/2018) for original research articles regarding the efficacy and safety of PMBV. Two reviewers independently screened references for inclusion and abstracted data including article details and echocardiographic parameters before and 24-72 h after PMBV, follow-up duration, and acute complications. Disagreements were resolved by third adjudicator. Quality of all included studies was evaluated using the Newcastle-Ottawa Scale NOS. RESULTS: 44/990 references met the inclusion criteria representing 6537 patients. Our findings suggest that PMBV leads to a significant increase in MVA (MD = 0.81 cm2; 0.76-0.87, p < 0.00001), LVEDP (MD = 1.89 mmHg; 0.52-3.26, p = 0.007), LVEDV EDV (MD = 5.81 ml; 2.65-8.97, p = 0.0003) and decrease in MPG (MD = -7.96 mmHg; -8.73 to -7.20, p < 0.00001), LAP (MD = -10.09 mmHg; -11.06 to -9.12, p < 0.00001), and SPAP (MD = -15.55 mmHg; -17.92 to -13.18, p < 0.00001). On short term basis, the pooled overall incidence estimates of repeat PMBV, mitral valve surgery, post-PMBV severe MR, and post-PMBV stroke, and systemic thromboembolism were 0.5%, 2%, 1.4%, 0.4%, and 0.7%% respectively. On long term basis, the pooled overall incidence estimates of repeat PMBV, mitral valve surgery, post-PMBV severe MR, and post-PMBV stroke, systemic thromboembolism were 5%, 11.5%, 5.5%, 2.7%, and 1.7% respectively. CONCLUSION: PMBV represents a successful approach for patients with mitral stenosis as evidenced by improvement in echocardiographic parameters and low rate of complications.

3.
Catheter Cardiovasc Interv ; 96(6): 1323-1330, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32180349

RESUMO

BACKGROUND: Transcatheter edge-to-edge repair with MitraClip is only approved for treatment of mitral regurgitation but is increasingly used to treat concomitant tricuspid regurgitation (TR) due to its common coexistence and association with poor outcomes. This study aimed to describe the learning curve associated with the challenge of off-label treatment of concomitant TR. METHODS: This is a retrospective review of initial and consecutive patients who underwent combined edge-to-edge repair of mitral and tricuspid valves (TVs) at our institution from August 2017 to October 2019. RESULTS: Repair of both valves with MitraClip was performed in 22 patients (median age 81.5 years, 32% female). Mean procedure time was 176 ± 47 min; mean fluoroscopy time was 65 ± 24 min. Procedure duration in the first tertile was significantly longer (223 ± 13 min) than in the third tertile (143 ± 23 min, p = .0003). Median number of total clips placed per case was 3; in 15 patients (68%), the anterior and septal leaflets of the TV were clipped. The average changes in mean right atrial (RA) and left atrial (LA) pressures were -1.7 ± 2.5 mmHg (p = .0080) and -3.2 ± 4.6 mmHg (p = .0045), respectively. The average changes in RA and LA V-wave heights were -3.3 ± 4.0 mmHg (p = .0009) and -8.1 ± 9.9 mmHg (p = .038), respectively. There was a significant trend toward decreasing residual TR over the course of the series (p = .046). At 30 days, survival was 100% and mean NYHA class decreased from 2.8 to 1.8 (p < .0001). CONCLUSIONS: Combined edge-to-edge tricuspid and mitral valve repair is safe and feasible. With experience, procedure duration and residual TR decreased.


Assuntos
Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Curva de Aprendizado , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Idoso de 80 Anos ou mais , Competência Clínica , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Duração da Cirurgia , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia
4.
Heart ; 106(12): 898-903, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31980440

RESUMO

OBJECTIVE: A subset of patients at the time of transcatheter mitral valve repair (TMVR) will have normal left atrial pressure (LAP) (<13 mm Hg) despite having severe mitral regurgitation (MR). The goal of this study was to determine clinical characteristics and outcomes in patients with normal LAP undergoing TMVR. METHODS: A single-centre retrospective cohort of consecutive patients who underwent transcatheter edge-to-edge mitral valve clip and continuous LAP monitoring between 5/1/2014 and 5/1/2018 was analysed. One-year mortality was compared by Kaplan-Meier survival curves. Multivariable analysis was performed to identify predictors of normal LAP and 1 year mortality. RESULTS: Of the 204 patients undergoing TMVR, 65% were men and the mean age was 81. Of these patients, 31 (15%) had normal LAP (mean LAP 10.5 mm Hg, mean V wave 16.5 mm Hg) and 173 had elevated LAP (mean LAP 19 mm Hg, mean V wave 32.5 mm Hg). The prevalence of severe MR was not different between groups, although the normal LAP group had significantly lower effective regurgitant orifice area and regurgitant volume. Other notable baseline characteristics including prior cardiac surgery, atrial fibrillation, hypertension, diabetes, congestive heart failure, body mass index, mechanism of MR and ejection fraction were similar between groups. However, there was an increased prevalence of chronic lung disease (CLD) (45.2% vs 17.3%, p<0.001) in the normal LAP group. On multivariate analysis, the only significant predictor of normal LAP was the presence of CLD (OR 4.79 (1.83-12.36), p=0.001) and 1-year mortality was significantly higher in the normal LAP group (32.3% vs 12.7%, p=0.006). After adjustment for comorbidities, normal LAP was no longer a predictor of 1-year mortality (RR 1.62 (0.64-4.06), p=0.32); however, CLD (RR 3.44 (1.37-8.67), p=0.01) remained a statistically significant predictor. CONCLUSION: Normal LAP at the time of TMVR is associated with a higher incidence of CLD which independently predicts increased 1-year mortality. In patients with CLD and apparently severe MR, measurement of LAP may help identify those with lower likelihood of benefit from TMVR.


Assuntos
Função do Átrio Esquerdo , Pressão Atrial , Cateterismo Cardíaco , Insuficiência da Valva Mitral/terapia , Valva Mitral/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Feminino , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
5.
J Invasive Cardiol ; 31(10): E306-E307, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31567123

RESUMO

Aortic paravalvular leak (PVL) is a known complication of TAVR. PVL closure using vascular occluder devices can be used, particularly in cases with annular calcification preventing adequate seal; however, delivery of equipment can be challenging in TAVR patients due to interaction with the valve stent. We describe a novel antegrade closure approach to treat transcatheter aortic PVL.


Assuntos
Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fluoroscopia , Humanos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Falha de Prótese , Reoperação , Dispositivos de Acesso Vascular
6.
J Am Soc Echocardiogr ; 32(11): 1426-1435.e1, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31466850

RESUMO

BACKGROUND: Patient selection for transcatheter edge-to-edge mitral valve repair (TMVR) remains challenging because of heterogenous mitral valve pathology and highly variable anatomy. The aim of this study was to investigate whether quantitative three-dimensional (3D) transesophageal echocardiographic modeling parameters are associated with optimal mitral regurgitation (MR) reduction in patients undergoing TMVR. METHODS: Fifty-nine patients underwent 3D transesophageal echocardiography during TMVR. Volumetric data sets were retrospectively analyzed using mitral valve quantitative 3D modeling software (Mitral Valve Navigator). Optimal MR reduction was defined as less than moderate residual MR. Logistic regression was used to correlate 3D transesophageal echocardiographic quantitative data to procedural success. RESULTS: Thirty-five patients had primary MR, 24 had mixed or secondary MR, and all patients had grade ≥ 3/4 MR before the procedure. Optimal MR reduction was achieved in 40 of 59 patients (68%). Univariate correlates of optimal MR reduction in patients with primary MR were lower mitral leaflet tenting volume (P = .049) and lower tenting height (P = .025); tenting height < 3 mm and tenting volume < 0.7 mL were associated with increased likelihood of optimal MR reduction (92% vs 48% [P = .01] and 81% vs 47% [P = .03], respectively). In mixed or secondary MR, annular height ≥ 5.5 mm was associated with increased likelihood of optimal MR reduction (94% vs 38%; P = .03). During follow-up, redo TMVR or surgical mitral valve replacement occurred exclusively in patients with suboptimal anatomy defined by 3D transesophageal echocardiography (10% vs 0%, P = .045). CONCLUSIONS: Quantitative 3D echocardiographic data are associated with favorable response to TMVR and could help optimize patient selection.


Assuntos
Cateterismo Cardíaco/métodos , Ecocardiografia Tridimensional/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Monitorização Intraoperatória/métodos , Cirurgia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Masculino , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Prognóstico , Estudos Retrospectivos , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 92(7): 1427-1432, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30079571

RESUMO

OBJECTIVES: To measure the intraprocedural change in left atrial pressure (LAP) with saline administration during transcatheter mitral valve repair (TMVR). BACKGROUND: TMVR with MitraClip offers an alternative to surgery in select patients. During this procedure, large volumes of fluid are routinely administered with anesthesia and to facilitate transcatheter valve repair. LAP, a measure used to guide repair, may thereby change as a result of volume expansion, suggesting a need for continuous intracardiac pressure monitoring. METHODS: Consecutive patients with severe mitral regurgitation underwent TMVR with MitraClip and continuous LAP monitoring through a dedicated sampling catheter. Specific LAP values were acquired immediately after transseptal access; before first clip deployment; and after deployment of the last clip. RESULTS: 151 patients (age 80 ± 8 years, 64% male) underwent TMVR with MitraClip and continuous LAP monitoring. Mean LAP and v-wave pressure increased significantly from baseline to pre-MitraClip deployment (P < 0.0001) and decreased significantly from deployment to procedure end (P < 0.0001). Linear regression of v-wave pressure change (from procedure start to clip deployment) relative to volume administration yielded a significantly nonzero slope (0.28 mmHg/min, P < 0.0001, r = 0.30). CONCLUSION: Fluid administration during TMVR leads to time-dependent increases in LAP. Such intraprocedural change underscores the need for targeted, if not continuous, LAP measurement during TMVR to optimize MitraClip placement and mitral regurgitation reduction.


Assuntos
Função do Átrio Esquerdo , Pressão Atrial , Cateterismo Cardíaco/instrumentação , Hidratação , Insuficiência da Valva Mitral/terapia , Valva Mitral/fisiopatologia , Solução Salina/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Feminino , Hidratação/efeitos adversos , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Estudos Prospectivos , Solução Salina/efeitos adversos , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
8.
Am J Cardiol ; 121(11): 1373-1379, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29580630

RESUMO

In patients with unexplained cardiomyopathy, electroanatomical mapping can identify abnormal tissue to target during electrophysiology-guided endomyocardial biopsy (EP-guided EMB). The objective of this study is to determine whether catheter ablation performed in the same setting as EP-guided EMB increases procedural risk. Sixty-seven patients (mean age 54.4 ± 13.8, 57% male) undergoing EP-guided EMB were included. Radiofrequency catheter ablation was performed in 17 patients (25%) for ventricular arrhythmias and in 2 (3%) for typical atrial flutter. Femoral arterial access was obtained in 90% ablation patients and 40% biopsy-only patients; vascular access complications were more common in the ablation group than in the EMB-only group (p = 0.02). There were no significant differences in rate of tricuspid regurgitation, thromboembolism, or pericardial effusion, whether procedural anticoagulation was used. In conclusion, catheter ablation and procedural anticoagulation can be combined with EP-guided EMB with an increased risk of vascular access complications, but no significant increase in intracardiac complications.


Assuntos
Arritmias Cardíacas/patologia , Biópsia/métodos , Cardiomiopatias/patologia , Ablação por Cateter/métodos , Endocárdio/patologia , Miocardite/patologia , Miocárdio/patologia , Sarcoidose/patologia , Adulto , Idoso , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/cirurgia , Flutter Atrial/etiologia , Flutter Atrial/patologia , Flutter Atrial/cirurgia , Bloqueio Atrioventricular/patologia , Bloqueio Atrioventricular/cirurgia , Cardiomiopatias/complicações , Técnicas Eletrofisiológicas Cardíacas , Endocárdio/cirurgia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocardite/complicações , Complicações Pós-Operatórias/epidemiologia , Sarcoidose/complicações , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/patologia , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/etiologia , Complexos Ventriculares Prematuros/patologia , Complexos Ventriculares Prematuros/cirurgia
9.
JACC Cardiovasc Interv ; 10(19): 1946-1956, 2017 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-28982558

RESUMO

OBJECTIVES: The aim of this study was to report the use trends and immediate and long-term outcomes of a large cohort of patients who underwent redo surgery or transcatheter repair of paravalvular leaks (PVLs) at a tertiary referral center. BACKGROUND: Percutaneous treatment of mitral PVL has emerged as an alternative to surgical treatment in high-risk surgical candidates. There are limited data on the utilization trends, safety, and efficacy of both procedures in the management of mitral PVL. METHODS: Patients who underwent treatment of mitral PVL at the Mayo Clinic between January 1995 and December 2015 were enrolled. Utilization trends, procedural details, technical success, and in-hospital and long-term outcomes were assessed. RESULTS: Three hundred eighty-one patients underwent percutaneous (n = 195) or surgical (n = 186) treatment of mitral PVLs. The mean age was 66 ± 12 years, and 37% of patients had bioprosthetic valves. Technical success was higher in the surgical group (95.5% vs. 70.1%; p < 0.001). In-hospital major adverse events were more common after surgery (22.5% vs. 7.7%; p < 0.001). In-hospital death occurred in 3.1% and 8.6% of patients undergoing percutaneous and surgical treatment, respectively (p = 0.027). However, in a multivariate logistic regression analysis, only active endocarditis, chronic renal failure, and severe mitral annular calcifications were significant predictors of in-hospital mortality. Reintervention rates were similar (11.3% vs. 17.2% in the percutaneous and surgical groups, respectively; p = 0.10), with the majority of reinterventions in the percutaneous group occurring early because of residual leak or persistent hemolysis. After risk adjustment, there was no significant difference in long-term survival between patients who underwent surgical versus transcatheter treatment of PVLs. CONCLUSIONS: In contemporary practice, patients with symptomatic mitral PVLs are best treated with an integrated team approach incorporating both surgical and percutaneous techniques. Patient selection and timing of intervention are critical to achieve optimal results.


Assuntos
Cateterismo Cardíaco , Remoção de Dispositivo , Insuficiência da Valva Mitral/terapia , Valva Mitral/cirurgia , Idoso , Bioprótese , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/mortalidade , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Minnesota , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Análise Multivariada , Razão de Chances , Modelos de Riscos Proporcionais , Desenho de Prótese , Falha de Prótese , Reoperação , Fatores de Risco , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento
10.
EuroIntervention ; 13(12): e1436-e1443, 2017 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-28943495

RESUMO

AIMS: The differential diagnosis of intracardiac masses (ICM) is wide. While imaging modalities can suggest a diagnosis, clinical decision making usually requires histopathologic diagnosis. The aim of this study was to describe the procedural technique, safety outcomes, diagnostic accuracy and clinical utility of percutaneous transcatheter biopsy (TCB) for histopathologic diagnosis of ICM. The records of all patients undergoing TCB of ICM at the Mayo Clinic catheterisation laboratories in Rochester, Minnesota, between 2002 and 2017 were retrieved and reviewed. METHODS AND RESULTS: TCB of ICM to establish histopathologic diagnosis was performed in 29 patients. Masses were located in the right-sided chambers in 93% of cases. Echocardiographic guidance was used. Ventricular arrhythmias requiring immediate cardioversion occurred in 7% of patients. No other complications were noted. The average number of samples retrieved per procedure was 7±3.6. A histopathologic diagnosis was made by TCB in 72% and altered clinical decision making in 52% of patients overall. Eleven patients (38%) who would otherwise have required excisional biopsy were able to avoid cardiovascular surgery. Each additional biopsy sample was associated with an increase in the likelihood of making a histopathologic diagnosis (OR 1.74, 95% CI: 1.05-2.87, p=0.032). CONCLUSIONS: Echo-guided percutaneous TCB of ICM provides an accurate diagnosis and alters clinical management in the majority of cases. The procedural complication rate is low. An increase in the number of samples retrieved markedly improves the ability to render a diagnosis. TCB may therefore be considered as a first-line approach for the histopathologic diagnosis of ICM.


Assuntos
Cateterismo Cardíaco/métodos , Neoplasias Cardíacas/diagnóstico , Miocárdio/patologia , Adulto , Idoso , Biópsia , Feminino , Neoplasias Cardíacas/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
11.
Catheter Cardiovasc Interv ; 90(4): 680-689, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28185394

RESUMO

BACKGROUND: Percutaneous paravalvular leak (PVL) closure is an alternative treatment option for severely symptomatic, high-surgical risk patients with PVL. Some patients require multiple percutaneous PVL closure procedures. However, the procedural characteristics and success rate of re-do PVL closure have not been well studied. AIMS: The aim of this study is to investigate the indications, procedural characteristics, technical success rate, and 30-day major adverse cardiovascular events (MACE) in patients who underwent re-do PVL closure. METHODS: Consecutive patients who underwent percutaneous paramitral or paraaortic leak closure at Mayo Clinic, Rochester, Minnesota from 2004 through 2015 were studied. Clinical and procedural characteristics of patients who underwent re-do PVL closure were compared to age- and sex-matched patients who underwent their first percutaneous PVL closure. Procedure success and 30-day MACE were compared in both the groups. RESULTS: Among 223 identified percutaneous PVL closures, 16 (7%) were re-do procedures. Patients who underwent re-do PVL closure were predominantly men (87.5%) with a mean age of 68 ± 15 years and an estimated mean Society of Thoracic Surgery (STS) 30-day mortality of 4.6 ± 2.8. Half of the re-do PVL closures were performed on mechanical valves and 62.5% were performed on paramitral defects. Indications for re-do PVL closure were: (1) emergence of new significant paravalvular defects in 50%, (2) incomplete index defect closure in 43.75%, and (3) index procedural complication in 6.25% of the cases. Procedural success was 75% in re-do procedures vs. 85.4% in age- and sex-matched control group (P = 0.45). Thirty-day MACE was 12.5% in the re-do group compared to 4.2% in the age- and-sex matched patients who underwent PVL closure for the first time (P = 0.35). CONCLUSION: Re-do percutaneous PVL closure is feasible with favorable procedural success rate and low 30-day MACE. Development of new paravalvular defects is the most common indication for re-do PVL closure, highlighting the importance of careful longitudinal monitoring and follow-up. © 2017 Wiley Periodicals, Inc.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Bioprótese , Estudos de Casos e Controles , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Hospitais com Alto Volume de Atendimentos , Humanos , Masculino , Pessoa de Meia-Idade , Minnesota , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/fisiopatologia , Sistema de Registros , Reoperação , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
12.
J Interv Cardiol ; 29(5): 539-545, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27696544

RESUMO

OBJECTIVES: This study sought to assess the learning curve for TMVR for treatment of primary mitral regurgitation (MR). BACKGROUND: Data are lacking regarding the technical experience required to achieve optimal clinical outcomes with transcatheter mitral valve repair (TMVR) using the edge-to-edge MitraClip technique. METHODS: We examined the sequential experience of the first 75 patients (age 80 ± 9 years; 77% male) who underwent TMVR at our institution. A sequence number of each patient was assigned as a continuous variable and in tertiles for analysis. RESULTS: TMVR with MitraClip was successful in 97% with an average procedural time of 106 ± 39 minutes. The 30-day rate of major adverse cardiovascular events was 7%. With increased case experience, there were decreases in procedural time, fluoroscopy time, length of hospital stay, and major adverse cardiovascular events. Procedural success, residual mitral regurgitation and NYHA functional classification at 30-day follow-up remained unchanged throughout the experience. CONCLUSIONS: The learning curve for TMVR with MitraClip for treatment of primary MR is characterized by a sequential reduction in procedure time, fluoroscopy time, procedural complications, and hospital length of stay at a tertiary academic medical center. Thirty-day procedural results are favorable and similar during the initial learning period.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Complicações Pós-Operatórias/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Feminino , Fluoroscopia/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Humanos , Curva de Aprendizado , Tempo de Internação/estatística & dados numéricos , Masculino , Insuficiência da Valva Mitral/epidemiologia , Duração da Cirurgia , Avaliação de Processos e Resultados em Cuidados de Saúde , Estados Unidos
13.
Ann Thorac Surg ; 102(1): 56-61, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27112646

RESUMO

BACKGROUND: Prior publications note increased adverse events after transapical compared with transfemoral access transcatheter aortic valve insertion (TAVI). We reviewed our TAVI experience to understand the differences in baseline patient characteristics and outcomes associated with the two access methods. METHODS: The records were reviewed of 567 patients who underwent transfemoral (n = 351, 61.9%) and transapical (n = 216, 38.1%) TAVI from November 2008 through July 2015. RESULTS: Compared with patients who underwent transfemoral access, the patients who underwent transapical access were older (82.0 ± 7.5 versus 79.6 ± 9.7 years; p = 0.006), had more peripheral vascular disease (78.2% versus 54.7%; p < 0.001), more previous coronary artery bypass graft operations (50.9% versus 32.5%; p < 0.001), and higher Society of Thoracic Surgeons predicted risk of mortality (9.4% ± 5.4% versus 8.8% ± 6.5%; p = 0.032). In-hospital and 30-day mortality rates, however, were similar between the two groups (transapical, n = 7, 3.2%; transfemoral, n = 13, 3.7%; p = 0.772). Follow-up echocardiography in 547 (100.0%) surviving patients at a median of 182 days (interquartile range, 35 to 420) demonstrated less paravalvular regurgitation grade of moderate or greater in patients who underwent transapical access (transapical, n = 6, 2.9%; transfemoral, n = 35, 10.4%; p = 0.001) but similar ejection fraction in the two groups (transapical, 55.4% ± 12.2%; transfemoral, 55.9% ± 13.0%; p = 0.419). Mortality rates at 1 year (transapical, 19.2% ± 3.0%; transfemoral,14.7% ± 3.2%) and 4 years (transapical, 47.4% ± 6.4%; transfemoral, 42.7% ± 4.9%) were also similar between the two groups (p = 0.342). CONCLUSIONS: Transapical and transfemoral transcatheter aortic valve insertions result in similar operative and longer term mortality rates, despite differences in baseline patient risk. The findings support the concept that access does not influence treatment-related mortality rates.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Feminino , Artéria Femoral , Humanos , Incidência , Masculino , Minnesota/epidemiologia , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Resultado do Tratamento
14.
Ann Thorac Surg ; 101(2): 592-7; discussion 597-8, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26410157

RESUMO

BACKGROUND: Extreme-risk patients (ie, Society of Thoracic Surgeons [STS] risk 15% or higher) with severe aortic valve stenosis may not obtain mortality benefit from aortic valve replacement (AVR). We reviewed our experience with this group of patients to better understand our triage process and outcomes. METHODS: We performed a retrospective review of 97 patients with severe aortic valve stenosis and STS risk of 15% or higher treated from 2008 through 2013. The median patient age was 85 years (minimum, 44; maximum, 97 years), and 47 patients (48.5%) were male. The STS risk of mortality was 19.8% (minimum, 15.1%; maximum, 60.9%). Patients were assigned to treatment groups based on the first aortic valve intervention of balloon aortic valvuloplasty (BAV group, 66 [68%]) or de novo AVR (d-AVR group, 31 [32%]). RESULTS: Patients in the BAV group were sicker, with a reduced ejection fraction (0.35 vs 0.57; p = 0.002) and greater prevalence of urgent/emergency operative status (32% vs 10%; p = 0.004) compared with those in the d-AVR group. After BAV, 33 patients (50%) demonstrated clinical improvement and went on to receive subsequent staged AVR after a median of 64 days (minimum, 3; maximum, 390 days). The mortality rate at 2 years was worse in the BAV group (57.3% ± 6.3%) than in the d-AVR group (29.5% ± 8.3%; p = 0.015), but was similar in patients who received BAV followed by staged AVR and de novo AVR (p = 0.426). CONCLUSIONS: BAV may triage select patients with STS risk 15% or higher who are questionable candidates for AVR. Patients with clinical improvement after BAV experience benefit from staged AVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão/métodos , Medição de Risco , Sociedades Médicas , Cirurgia Torácica , Adulto , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
15.
J Heart Valve Dis ; 24(3): 323-4, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26901905

RESUMO

Transcatheter mitral valve repair is an effective treatment option for patients with symptomatic mitral regurgitation and high surgical risk. Typically, transcatheter mitral valve repair is less effective in reducing mitral regurgitation severity compared to surgical mitral valve repair. Herein is presented a case of complete resolution of mitral regurgitation, as assessed by Doppler echocardiography and left atrial V-wave.


Assuntos
Função do Átrio Esquerdo , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Insuficiência da Valva Mitral/cirurgia , Idoso de 80 Anos ou mais , Feminino , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Ultrassonografia
16.
Catheter Cardiovasc Interv ; 84(5): 801-8, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-24782364

RESUMO

OBJECTIVES: Our objective was to determine if technical changes combined with radiation safety initiatives reduced the radiation dose delivered to patients during congenital catheterization. BACKGROUND: Use of ionizing radiation is necessary during cardiac catheterization. Minimizing radiation dose, while maintaining clinically useful image quality, is an important safety issue. In our congenital heart center intentional practice changes, including technical changes and provider awareness initiatives, were implemented to decrease radiation dose. METHODS: Data were retrospectively collected for all procedures involving children and adults with congenital heart disease (CHD) undergoing catheterization over 45 months. Cases were divided into three categories including: noninterventional (NI), simple intervention (SI), and complex intervention (CI). The change in dose was modeled as log of cumulative air kerma (Ka,r ). The change in Ka,r was evaluated for each procedural category as well as changes occurring as a function of age and weight. RESULTS: Considering all procedures (n = 1,082), Ka,r decreased by 61%. In the NI group (n = 481), Ka,r decreased by 71%. In the SI group (n = 424), Ka,r decreased by 74%. The Ka,r for the 10-17 year old group (n = 125) and those ≥18 years (n = 709) decreased 74 and 67%, respectively. The Ka,r decreased 72 and 66% for those 20-60 kg and ≥60 kg, respectively. Groups not showing significant change in Ka,r included CI, age ≤9 years, and weight ≤20 kg. CONCLUSIONS: Through technical changes and provider awareness initiatives, our institution dramatically reduced the radiation dose in the majority of pediatric and adult CHD patients undergoing cardiac catheterization.


Assuntos
Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/diagnóstico , Doses de Radiação , Proteção Radiológica/métodos , Adulto , Fatores Etários , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Bases de Dados Factuais , Feminino , Cardiopatias Congênitas/terapia , Humanos , Lactente , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Melhoria de Qualidade , Valores de Referência , Estudos Retrospectivos , Medição de Risco
17.
Congenit Heart Dis ; 9(3): 228-34, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-23947956

RESUMO

OBJECTIVE: Percutaneous coronary intervention (PCI) is commonly used in adult patients with coronary artery disease, but data on PCI in children and adolescents remain limited. Herein, we describe our experience with the use of PCI in pediatric and adolescent patients. DESIGN: This is a retrospective review. SETTING: The study was conducted at Mayo Clinic, Rochester, MN. PATIENTS: All patients ≤18 years old who underwent PCI from 2004 to 2012 were included. INTERVENTIONS: Intravascular ultrasound and balloon angioplasty were performed in all patients, with subsequent stent placement in 6/7 (86%) procedures. OUTCOME MEASURES: Residual postintervention stenosis, early procedural morbidity and mortality were the outcome measures. RESULTS: Overall, seven unique PCI procedures were performed in five patients (four males, mean age 13.2 ± 3.8 years, range 8-18 years). Mean follow-up interval was 2 (0.6-5.5) years. Indications for the procedures included transplant coronary vasculopathy (n = 1), coronary dissection (n = 1), and acute coronary thrombosis/myocardial infarction (n = 1). Additionally, there were two patients (n = 2) who experienced coronary compression as a sequelae of prior heart surgery. Intravascular ultrasound and balloon angioplasty were performed in all patients, with subsequent stent placement in 6/7 (86%) procedures. A total of eight stents were placed (average stent diameter 3 ± 0.5 mm), including six (75%) drug-eluting stents. The targeted coronary artery lesions were successfully treated in all seven procedures. There was no early procedural morbidity or mortality. Two patients were noted to have angiographic evidence of in-stent restenosis at 3 and 15 months postdeployment, respectively, despite treatment with aspirin and clopidogrel. CONCLUSION: PCI in children and adolescents can be utilized to improve coronary blood flow in a variety of clinical situations. It may be particularly effective in cases of postsurgical coronary compression. Close angiographic follow-up is critical as these patients are at risk for in-stent restenosis.


Assuntos
Angioplastia Coronária com Balão , Cardiopatias/terapia , Adolescente , Fatores Etários , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Criança , Angiografia Coronária , Circulação Coronária , Feminino , Cardiopatias/diagnóstico , Cardiopatias/fisiopatologia , Humanos , Masculino , Minnesota , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção
18.
J Card Surg ; 28(4): 348-52, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23750934

RESUMO

BACKGROUND: Vascular complications associated with transfemoral transcatheter aortic valve insertion (TAVI) are a frequent untoward consequence of arterial sheath insertion. We report the prevalence of anatomic arterial injury with open artery access TAVI. METHODS: This review consisted of 53 consecutive patients who received transfemoral Sapien 23 or 26 mm TAVI via the 22- or 24-French sheath through open artery access from November 2008. The median age of the patients was 83 years (range, 59 to 94), and there were 31 males (58%). All arteries were examined to determine the optimal point of access and then explored after removal of the sheath to document injury. RESULTS: The accessed artery had a minimal lumen diameter of 8.9 mm (7.2 to 14.7) and a sheath-to-artery ratio of 1.0 (0.6 to 1.2). The point of access was the common femoral artery in 33 patients (62%) and the external iliac artery in 20 (38%). Exploration of the artery demonstrated localized arterial injury in 22 patients (42%). Female gender was predictive of injury (p = 0.03), but arterial access site location, presence of arterial access calcification, sheath-to-artery ratio, and sheath size were not. Techniques of artery repair included primary closure in 34 patients (64%), pericardial patch angioplasty in 15 (28%), and graft interposition in 4 (8%). There was one minor groin wound complication. CONCLUSIONS: Open artery access allows for direct examination and optimal access site choice of the vessel during transfemoral TAVI. Localized arterial injury was commonly encountered after 22- and 24-French sheath insertion, but the associated artery repair complication rate was low.


Assuntos
Valva Aórtica/cirurgia , Cateterismo Periférico/efeitos adversos , Artéria Femoral/lesões , Implante de Prótese de Valva Cardíaca/efeitos adversos , Dispositivos de Acesso Vascular/efeitos adversos , Lesões do Sistema Vascular/epidemiologia , Lesões do Sistema Vascular/etiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Artéria Femoral/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Fatores Sexuais , Lesões do Sistema Vascular/patologia
19.
Ann Thorac Surg ; 95(4): 1439-41, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23522208

RESUMO

Transcatheter aortic valve insertion is an accepted treatment for select patients at high-risk for standard aortic valve insertion. Constraints imposed by the Food and Drug Administration, Centers for Medicare and Medicaid Services, and the PARTNER Trial Executive Committee require a transfemoral approach in certain patients. The presence of aortoiliac aneurysms, occlusive disease, and excessive vessel tortuosity may create difficulties for safe transfemoral access. We report a case in which the limitation of severe iliac artery occlusive disease was overcome by placement of an abdominal aortic endovascular graft that subsequently allowed successful transfemoral access and transcatheter aortic valve implantation.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Estenose da Valva Aórtica/cirurgia , Prótese Vascular , Procedimentos Endovasculares/métodos , Implante de Prótese de Valva Cardíaca/métodos , Idoso de 80 Anos ou mais , Angiografia , Aneurisma da Aorta Abdominal/complicações , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Cateterismo Cardíaco , Humanos , Masculino , Tomografia Computadorizada por Raios X
20.
Mayo Clin Proc ; 81(5): 615-8, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16706258

RESUMO

OBJECTIVE: To describe a multicenter experience with patent foramen ovale (PFO) and atrial septal defect (ASD) device closure for presumed paradoxical emboli in children and young adults (<35 years old). PATIENTS AND METHODS: Medical records were reviewed of patients who had device closure of an ASD or PFO, who were younger than 35 years, and who had a history of presumed paradoxical embolus between January 1999 and August 2005 at Mayo Clinic, Rochester, Minn, University of Parma, Parma, Italy, and Loyola University Medical Center, Maywood, Ill. RESULTS: Forty-five patients fulfilled the inclusion criteria. Median patient age was 29.0 years (range, 5.0-34.9 years), and 23 patients (51%) were male. Clinical diagnoses included the following: stroke, 30 (67%); transient ischemic attack, 13 (29%); myocardial infarction, 1 (2%); and renal infarct, 1 (2%). Overall, 42 patients (93%) had a PFO, and 3 (7%) had an ASD. Seventeen patients had known cardiovascular disease risk factors: tobacco use (10 patients), hypercoagulable states (7 patients), systemic hypertension (3 patients), and hyperilpidemia (2 patients). No major procedural complications occurred. Median follow-up evaluation was performed at 5.3 months (range, 2.5-40.0 months). Forty-four patients (98%) had no recurrent neurologic events and no residual atrial shunt by contrast transthoracic echocardiography. CONCLUSIONS: Cryptogenic ischemic events occur in young patients and have serious sequelae. The potential for paradoxical embolization through a PFO or an ASD should be assessed in all such patients. In our short-term follow-up, device closure was a safe alternative therapeutic option for children and young adults with presumed paradoxical emboli.


Assuntos
Embolia Paradoxal/complicações , Comunicação Interatrial/complicações , Ataque Isquêmico Transitório/etiologia , Acidente Vascular Cerebral/etiologia , Adolescente , Adulto , Cateterismo , Criança , Pré-Escolar , Ecocardiografia , Feminino , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/terapia , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA