Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
ANZ J Surg ; 89(11): 1424-1427, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31628729

RESUMO

BACKGROUND: Polymethylmethacrylate cement is used in total knee arthroplasty and plays a significant role in the success of the procedure. Temperature variation is known to influence cement setting time in vitro. Our aim is to evaluate the relationship between ambient theatre temperature and cement setting time in vivo. METHODS: Theatre temperature and cement setting time were prospectively recorded during 683 total knee arthroplasties over 8 years using a single cement and vacuum mixing system (Simplex with tobramycin). Setting time was defined as the time until a scalpel blade could not indent the cement surface. RESULTS: Mean temperature was 18.92°C (SD 1.16) and setting time 13.08 min (SD 1.92). A moderate inverse relationship exists between ambient temperature and setting time (Pearson's R = -0.423); however, potential setting times within a given temperature range varied considerably (<19°C: 8-19.1 min, 19-20°C: 7-18 min and >20°C: 7.5-16 min), suggesting that temperature alone cannot reliably predict setting time. CONCLUSION: Our data support the current understanding of bone cement properties in vivo and suggest that surgeons should be mindful in regards to unpredictable cement setting time and optimal theatre environment.


Assuntos
Artroplastia do Joelho , Cimentos Ósseos , Salas Cirúrgicas , Polimetil Metacrilato , Temperatura , Humanos , Fenômenos Físicos , Fatores de Tempo
2.
Front Surg ; 2: 65, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26697432

RESUMO

While the Lapidus procedure is a widely accepted technique for treatment of hallux valgus, the optimal fixation method to maintain joint stability remains controversial. The purpose of this study is to evaluate the biomechanical properties of new shape memory alloy (SMA) staples arranged in different configurations in a repeatable first tarsometatarsal arthrodesis model. Ten sawbones models of the whole foot (n = 5 per group) were reconstructed using a single dorsal staple or two staples in a delta configuration. Each construct was mechanically tested non-destructively in dorsal four-point bending, medial four-point bending, dorsal three-point bending, and plantar cantilever bending with the staples activated at 37°C. The peak load (newton), stiffness (newton per millimeter), and plantar gapping (millimeter) were determined for each test. Pressure sensors were used to measure the contact force and area of the joint footprint in each group. There was a statistically significant increase in peak load in the two staple constructs compared to the single staple constructs for all testing modalities with P values range from 0.016 to 0.000. Stiffness also increased significantly in all tests except dorsal four-point bending. Pressure sensor readings showed a significantly higher contact force at time zero (P = 0.037) and contact area following loading in the two staple constructs (P = 0.045). Both groups completely recovered any plantar gapping following unloading and restored their initial contact footprint. The biomechanical integrity and repeatability of the models was demonstrated with no construct failures due to hardware or model breakdown. SMA staples provide fixation with the ability to dynamically apply and maintain compression across a simulated arthrodesis following a range of loading conditions.

3.
Orthopedics ; 38(8): 490-3, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26313167

RESUMO

The extra-articular impingement of the greater trochanter against the ileum is an underrated cause of early dislocation in total hip arthroplasty. In this preliminary study, the authors assess the effectiveness of an anterior longitudinal osteotomy of the greater trochanter for preventing dislocation. A total of 115 patients underwent a total hip arthroplasty through a posterolateral approach. All patients underwent clinical and radiological follow-up at 1, 3, and 6 months. No dislocation was reported. All patients demonstrated fast recovery of range of motion and walking. No trochanter fractures were observed. The osteotomy of the greater trochanter is an effective surgical technique that decreases anterior impingement and consequently lowers the dislocation rate in primary total hip arthroplasty. [Orthopedics. 2015; 38(8):490-493.].


Assuntos
Artroplastia de Quadril/métodos , Fêmur/cirurgia , Osteotomia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artrite/cirurgia , Epífises/cirurgia , Feminino , Impacto Femoroacetabular/prevenção & controle , Necrose da Cabeça do Fêmur/cirurgia , Luxação do Quadril/prevenção & controle , Luxação Congênita de Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento , Caminhada/fisiologia
4.
Joints ; 1(4): 161-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-25606528

RESUMO

PURPOSE: to evaluate the safety and effectiveness of the polyurethane meniscal scaffold through clinical examination, MRI and arthroscopic second look, over a minimum two-year follow-up. METHODS: between 2009 and 2011, 19 patients underwent meniscal scaffold implantation in our department (medial meniscus in 16 cases lateral meniscus in two cases, and bilateral in one case). All the patients were clinically evaluated preoperatively, and at 6, 12, and 24 months after surgery using Lysholm score, Tegner score, and VAS. Ten patients were studied with MRI, and nine patients were evaluated arthroscopically. RESULTS: no adverse reactions to the implant were observed. The clinical scores showed a significant improvement at 6 months and increased progressively over time. On MRI studies, the implants showed a clear hyperintense signal, sometimes irregular, and the chondral surface was preserved in all cases. At arthroscopic second look in the first months after surgery, the scaffold size was unchanged and the scaffold appeared light yellowish in color and well integrated into the surrounding tissues. At arthroscopic second look at 12 and 24 months the scaffold was found to have an irregular morphology and to be slightly reduced in size. CONCLUSIONS: polyurethane meniscal scaffold is a good alternative to a collagen scaffold, but a longer follow-up is needed to evaluate the scaffold degradation and chondral coverage. LEVEL OF EVIDENCE: level IV, therapeutic case series.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA