Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
2.
Catheter Cardiovasc Interv ; 100(5): 903-909, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36040688

RESUMO

OBJECTIVES: To report the experience of a high-volume center with balloon-expandable (BE) stents implantation to manage vascular complications after transcatheter aortic valve replacement (TAVR). BACKGROUND: Despite increased operator experience and better devices, vascular complications after TAVR are still a major issue and covered stent implantation is often required. METHODS: We retrospectively collected baseline and procedural data about 78 consecutive patients who underwent BE stent implantation to manage a vascular complication after transfemoral TAVR. Primary endpoints were technical success, incidence of new-onset claudication and need for vascular interventions during long-term follow-up. Secondary endpoints included length of hospitalization, in-hospital and 30-day mortality, and major postoperative complications. RESULTS: BE stents implantation to manage vascular complications after TAVR was successfully performed in 96.2% of the cases, with bailout surgery required in two cases. One patient suffered in-hospital death. Predischarge Doppler Ultrasound revealed no cases of in-stent occlusion or fracture. At a median follow-up of 429 days (interquartile range, 89-994 days), no cases of symptomatic leg ischemia were reported and only one patient experienced new-onset claudication. CONCLUSIONS: Our experience showed good periprocedural and long-term results of BE covered stent implantation to manage vascular complication after TAVR. Their great radial outward force may guarantee effective hemostasis without necessarily being associated with stent deformation/fracture resulting in restenosis or further interventions. More research is needed to define the role of BE covered stents in this setting.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Doenças Vasculares , Humanos , Seguimentos , Estudos Retrospectivos , Mortalidade Hospitalar , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Resultado do Tratamento , Stents , Doenças Vasculares/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
3.
ESC Heart Fail ; 9(5): 3188-3197, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35770333

RESUMO

AIMS: Aortic stenosis (AS) and cardiac amyloidosis (CA) are typical diseases of the elderly. Up to 16% of older adults with severe AS referred to transcatheter aortic valve replacement (TAVR) have a concomitant diagnosis of CA. CA-AS population suffers from reduced functional capacity and worse prognosis than AS patients. As the prognostic impact of TAVR in patients with CA-AS has been historically questioned and in light of recently published evidence, we aim to provide a comprehensive synthesis of the efficacy and safety of TAVR in CA-AS patients. METHODS AND RESULTS: We performed a systematic review and meta-analysis of studies: (i) evaluating mortality with TAVR as compared with medical therapy in CA-AS patients and (ii) reporting complications and clinical outcomes of TAVR in CA-AS patients as compared with patients with AS alone. A total of seven observational studies were identified: four reported mortality with TAVR, and four reported complications and clinical outcomes after TAVR of patients with CA-AS compared with AS alone patients. In patients with CA-AS, the risk of mortality was lower with TAVR (n = 44) as compared with medical therapy (n = 36) [odds ratio (OR) 0.23, 95% confidence interval (CI) 0.07-0.73, I2  = 0%, P = 0.001, number needed to treat = 3]. The safety profile of TAVR seems to be similar in patients with CA-AS (n = 75) as compared with those with AS alone (n = 536), with comparable risks of stroke, vascular complications, life-threatening bleeding, acute kidney injury, and 30 day mortality, although CA-AS was associated with a trend towards an increased risk of permanent pacemaker implantation (OR 1.76, 95% CI 0.91-4.09, I2  = 0%, P = 0.085). CA is associated with a numerically higher rate of long-term mortality and rehospitalizations following TAVR in patients with CA-AS as compared with those with AS alone. CONCLUSIONS: TAVR is an effective and safe procedure in CA-AS patients, with a substantial survival benefit as compared with medical therapy, and a safety profile comparable with patients with AS alone except for a trend towards higher risk of permanent pacemaker implantation.


Assuntos
Amiloidose , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Amiloidose/complicações , Amiloidose/diagnóstico , Amiloidose/cirurgia
4.
Catheter Cardiovasc Interv ; 99(6): 1766-1777, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35312151

RESUMO

INTRODUCTION: Device entrapment is a life-threatening complication during percutaneous coronary intervention (PCI). However, the success for its management is predominantly based on operator experience with limited available guidance in the published literature. METHODS: A systematic review was performed on December 2021; we searched PubMed for articles on device entrapment during PCI. In addition, backward snowballing (i.e., review of references from identified articles and pertinent reviews) was employed. RESULTS: A total of 4209 articles were retrieved, of which 150 studies were included in the synthesis of the data. A methodical algorithmic approach to prevention and management of device entrapment can help to optimize outcomes. The recommended sequence of steps are as follows: (a) pulling, (b) trapping, (c) snaring, (d) plaque modification, (e) telescoping, and (f) surgery. CONCLUSIONS: In-depth knowledge of the techniques and necessary tools can help optimize the likelihood of successful equipment retrieval and minimization of complications.


Assuntos
Intervenção Coronária Percutânea , Placa Aterosclerótica , Humanos , Resultado do Tratamento
5.
Eur J Cardiothorac Surg ; 61(4): 934-941, 2022 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-35188566

RESUMO

OBJECTIVES: Vascular complications (VC) are the most frequent drawback of transcatheter aortic valve implantation (TAVI), affecting up to 20% of overall procedures. Data on the treatment and their long-term impact are scarce. The goal of this study was to report on the incidence, management and impact on the long-term outcomes of VC following TAVI. METHODS: This was a multicentric retrospective analysis of consecutive patients undergoing TAVI. The primary endpoint was freedom from major adverse cardiac and cerebrovascular events at long-term follow-up. Adverse events were evaluated according to Valve Academic Research Consortium-2 criteria. RESULTS: A total of 2145 patients were included: VC occurred in 188 (8.8%); of which 180 were limited to the access site. Two-thirds of the VC were minor; 8% required surgical treatment; the remaining were repaired percutaneously. The major adverse cardiac and cerebrovascular events-free survival at 2 years was 83.0% for patients with VC and 86.7% for those without (P = 0.143), but 71.9% for patients with major compared to 89.0% in those with minor VC (P = 0.022). Major VC and diabetes mellitus independently predicted worse outcomes at 2 years. The major adverse cardiac and cerebrovascular events-free survival rate and the occurrence of vascular adverse events in the long term among patients with VC at the access site treated by endovascular techniques (covered stent implantation or angioplasty) were similar to those without VC (84.2% vs 86.7%; P = 0.635). CONCLUSIONS: Major but not minor VC impact long-term survival after TAVI. Covered stents implanted to manage VC at the access site have no impact on the long-term clinical outcome of TAVI.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
Curr Cardiol Rep ; 23(10): 137, 2021 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-34410511

RESUMO

PURPOSE OF THE REVIEW: Annular-based strategies for treating tricuspid valve (TV) regurgitation do not always have satisfactory long-term outcomes. Management of failed TV annuloplasty can be challenging and requires a dedicated heart team approach. This review explores the treatment options available for failed TV annuloplasty. RECENT FINDINGS: Recent developments and novel percutaneous treatment options have emerged as promising alternatives for patients with failed TV annuloplasty. Leaflet-based interventions, valve-in-valve procedures, transcatheter tricuspid valves and new-generation trans-caval valves are all feasible options, which can assure good results whilst minimizing risks for the patient. Failure of tricuspid annuloplasty is not uncommon amongst patients treated with either a tricuspid ring or suture-based device. The complex anatomy, physiology and clinical risk profile should be carefully evaluated on an individual patient-by-patient basis in order to select the most appropriate clinical and percutaneous treatment strategy. Different transcatheter tricuspid valve repair or replacement techniques may provide an attractive alternative treatment option for managing this challenging patient cohort.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide , Valva Aórtica , Humanos , Valva Mitral/cirurgia , Recidiva , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
8.
Int J Cardiol ; 338: 58-62, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34090956

RESUMO

BACKGROUND: Horizontal aorta (HA) is an anatomical feature that can pose significant technical challenges for the successful positioning of the bioprosthetic valve during transcatheter aortic valve replacement (TAVR). Physiological range of aortic angle (AA) is unknown; hence there is no cutoff AA for classifying HA. Moreover, patient characteristics predicting HA are under-investigated. METHODS: This was a retrospective analysis of prospective collected data from 16 heart valve centers in Europe. The study utilized a common dataset with a priori agreed-upon definitions and variables. Eligible patients underwent TAVR between 2014 and 2020 and had multidetector computed tomographic imaging data available for determining the AA. The analysis described the distribution of AA and potential predictors of HA. Inter-center variability was also explored. RESULTS: For 4022 patients analyzed, the mean AA ± standard deviation was 49.4° ± 9.4° (median 49°, inter-quartile range [IQR] 12°, range 18-90°). There was no significant difference in mean AA between men and women (49.4° ± 9.1° vs. 49.6° ± 9.3°, respectively; p = 0.53); therefore, 49.4° was accepted as the cutoff value for HA in subsequent analyses. Covariates significantly associated with HA included age (odds ratio [OR]: 1.02, 95% confidence interval [CI]: 1.01-1.04, p < 0.001), body mass index (OR: 1.06, 95% CI: 1.05-1.08, p < 0.01), previous cardiac surgery (OR: 0.58, 95% CI: 0.45-0.75, p < 0.001), and porcelain aorta (OR: 0.66, 95% CI: 0.52-0.85, p = 0.001). Some inter-center variability was observed. CONCLUSIONS: We defined 49.4° as the mean AA, and also associated predictors of HA in a large case series of patients with severe aortic stenosis candidates for TAVR.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Aorta , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Europa (Continente) , Feminino , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
9.
G Ital Cardiol (Rome) ; 22(3 Suppl 1): 32S-38S, 2021 03.
Artigo em Italiano | MEDLINE | ID: mdl-33847321

RESUMO

Acute mitral regurgitation is a life-threatening pathology. Nowadays, percutaneous mitral valve repair with the MitraClip device offers, in selected patients, a safe and effective therapeutic alternative to open surgery. Hereby, we report the case of an 82-year-old woman with lateral ST-elevation myocardial infarction determining severe acute mitral regurgitation, who was treated with an urgent MitraClip procedure. Moreover, we discuss echocardiographic assessment of acute mitral regurgitation and we review available literature and possible management of this complex scenario.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso de 80 Anos ou mais , Feminino , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 98(3): 595-604, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33586278

RESUMO

BACKGROUND: Valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) is an emerging alternative to re-do surgery. However, the challenge of coronary access (CA) following ViV-TAVR is a potential limitation as TAVR expands to younger lower-risk populations. OBJECTIVES: Using post-implantation computed tomography (CT) scans to evaluate the geometrical relationship between coronary ostia and valve frame in patients undergoing ViV-TAVR with the ACURATE neo valve. METHODS: Post-implant CT scans of 18 out of 20 consecutive patients treated with the ACURATE neo valve were analyzed. Coronary ostia location in relation to the highest plane (HP) (highest point of the ACURATE neo or surgical valve) was determined. Ostia located below the highest plan were further subclassified according to the gap available between the transcatheter heart valve frame and ostium (transcatheter-to-coronary [TTC] distance). The impact implantation depth has on these geometrical relationships was evaluated. RESULTS: A total of 21 out of 36 coronary ostia (58%) were located below the level of the HP with the left coronary artery (36%) more likely to be affected than the right (22%). Further sub-classification of these ostia revealed a large (>6 mm), moderate (4-6 mm), and small (<4 mm) TTC distance in 57% (12/21), 38% (8/21), and in 6% (1/18) of cases, respectively. At an implantation depth <4 mm compared to >4 mm, all ostia were located below the HP with no difference in post-procedural mean gradients (14.5 mmHg ± 4.7 vs. 12.6 mmHg ± 5.8; p = .5, 95%CI 3.8-7.5). CONCLUSIONS: CA following ACURATE neo implantation for ViV-TAVR could potentially be challenging in a significant proportion of patients and specific consideration should be given to the implantation depth.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Tomografia , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Cardiovasc Revasc Med ; 28S: 118-120, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32855084

RESUMO

We report the case of an 85-year-old man with severe aortic stenosis who underwent high-risk percutaneous coronary intervention with Impella CP support. Unfortunately, the device caused mitral chordae tendineae rupture leading to severe mitral regurgitation. The patient underwent a staged fully percutaneous treatment with transcatheter aortic valve replacement followed by elective Mitraclip therapy. Echocardiographic monitoring is of paramount importance during Impella insertion and removal in order to avoid and deal with mitral damage. Mitraclip therapy is a feasible rescue therapy for severe mitral regurgitation due to chordae rupture in patients at high risk for surgery.


Assuntos
Estenose da Valva Aórtica , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
12.
Interact Cardiovasc Thorac Surg ; 32(1): 20-28, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33201993

RESUMO

OBJECTIVES: To compare device success and paravalvular leak rates of 3 new-generation transcatheter aortic valve replacement devices in patients with bicuspid aortic valve stenosis and to test their biomechanical performance in a computer-based simulation model of aortic root with increasing ellipticity. METHODS: This retrospective multicentre study included 56 bicuspid aortic valve patients undergoing transcatheter aortic valve replacement with new-generation devices: Lotus/Lotus Edge (N = 15; 27%), Evolut-R (N = 20; 36%) and ACURATE neo (N = 21; 37%). Three virtual simulation models of aortic root with increasing index of eccentricity (0-0.25-0.5) were implemented. Stress distribution, stent-root contact area and paravalvular orifice area were computed. RESULTS: Device success was achieved in 43/56 patients (77%) with comparable rates among Lotus (87%), Evolut-R (60%) and ACURATE neo (86%; P = 0.085). Moderate paravalvular leak rate was significantly lower in the Lotus group as compared to Evolut-R group (0% vs 30%; P = 0.027) and comparable to the ACURATE neo group (0% vs 10%; P = 0.33). By index of eccentricity = 0.5, Lotus showed a uniform and symmetric pattern of stress distribution with absent paravalvular orifice area, ACURATE neo showed a mild asymmetry with small paravalvular orifice area (1.1 mm2), whereas a severely asymmetric pattern was evident with Evolut-R, resulting in a large paravalvular orifice area (12.0 mm2). CONCLUSIONS: Transcatheter aortic valve replacement in bicuspid aortic valve patients with new-generation devices showed comparable device success rates. Lotus showed moderate paravalvular leak rate comparable to that of ACURATE neo and significantly lower than Evolut-R. On simulation, Lotus and ACURATE neo showed optimal adaptability to elliptic anatomies as compared to Evolut-R.


Assuntos
Doença da Válvula Aórtica Bicúspide/cirurgia , Constrição Patológica/cirurgia , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Aorta/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Humanos , Masculino , Estudos Retrospectivos , Stents , Resultado do Tratamento
13.
Lancet ; 395(10235): 1487-1495, 2020 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-32386592

RESUMO

BACKGROUND: Antiplatelet therapy is recommended among patients with established atherosclerosis. We compared monotherapy with a P2Y12 inhibitor versus aspirin for secondary prevention. METHODS: In this systematic review and meta-analysis, all randomised trials comparing P2Y12 inhibitor with aspirin monotherapy for secondary prevention in patients with cerebrovascular, coronary, or peripheral artery disease were evaluated for inclusion. On Dec 18, 2019, we searched PubMed, Embase, BioMedCentral, Google Scholar, and the Cochrane Central Register of Controlled Trials. Additionally, we reviewed references from identified articles and searched abstracts from 2017 to 2019 presented at relevant scientific meetings. Data about year of publication, inclusion and exclusion criteria, sample size, baseline patients' features including the baseline condition determining study inclusion (ie, cerebrovascular, coronary, or peripheral artery disease), P2Y12 inhibitor type and dosage, aspirin dosage, endpoint definitions, effect estimates, follow-up duration, and percentage of patients lost to follow-up were collected. Odds ratios (ORs) and 95% CIs were used as metric of choice for treatment effects with random-effects models. Co-primary endpoints were myocardial infarction and stroke. Key secondary endpoints were all-cause death and vascular death. Heterogeneity was assessed with the I2 index. This study is registered with PROSPERO (CRD42018115037). FINDINGS: A total of nine randomised trials were identified and included in this study, and 42 108 patients randomly allocated to a P2Y12 inhibitor (n=21 043) or aspirin (n=21 065) were included in our analyses. Patients who received a P2Y12 inhibitor had a borderline reduction for the risk of myocardial infarction compared with those who received aspirin (OR 0·81 [95% CI 0·66-0·99]; I2=10·9%). Risks of stroke (OR 0·93 [0·82-1·06]; I2=34·5%), all-cause death (OR 0·98 [0·89-1·08]; I2=0%), and vascular death (OR 0·97 [0·86-1·09]; I2=0%) did not differ between patients who received a P2Y12 inhibitor and those who received aspirin. Similarly, the risk of major bleeding (OR 0·90 [0·74-1·10]; I2=3·9%) did not differ between patients who received a P2Y12 inhibitor and those who received aspirin. The number needed to treat to prevent one myocardial infarction with P2Y12 inhibitor monotherapy was 244 patients. Findings were consistent regardless of the type of P2Y12 inhibitor used. INTERPRETATION: Compared with aspirin monotherapy, P2Y12 inhibitor monotherapy is associated with a risk reduction for myocardial infarction and a comparable risk of stroke in the setting of secondary prevention. The benefit of P2Y12 inhibitor monotherapy is of debatable clinical relevance, in view of the high number needed to treat to prevent a myocardial infarction and the absence of any effect on all-cause and vascular mortality. FUNDING: Italian Ministry of Education.


Assuntos
Aspirina/uso terapêutico , Aterosclerose/tratamento farmacológico , Clopidogrel/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Antagonistas do Receptor Purinérgico P2Y/uso terapêutico , Ticagrelor/uso terapêutico , Ticlopidina/uso terapêutico , Idoso , Aterosclerose/complicações , Transtornos Cerebrovasculares/tratamento farmacológico , Doença das Coronárias/tratamento farmacológico , Feminino , Hemorragia/induzido quimicamente , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/prevenção & controle , Doença Arterial Periférica/tratamento farmacológico , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Prevenção Secundária/métodos , Acidente Vascular Cerebral/prevenção & controle
14.
Int J Cardiol ; 290: 52-58, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30917900

RESUMO

BACKGROUND: This study aimed to evaluate real-world clinical outcome of patients needing short dual antiplatelet therapy (S-DAPT) following PCI with Ultimaster® thin-strut, biodegradable polymer sirolimus-eluting stent (BP-SES), which was supposed to induce faster stent endothelialization and reduce device thrombogenicity. METHODS: In this sub-group analysis of patients enrolled in the ULISSE registry, two groups were identified: 1) patients discharged with S-DAPT (≤3-month) due to high bleeding risk or need for urgent major non-cardiac surgery and 2) patients discharged with recommended DAPT (R-DAPT) duration (≥6-month). The primary ischemic-safety and bleeding-safety endpoints were TLF (composite of cardiac-death, target vessel MI, and clinically driven target lesion revascularization), and BARC major bleedings (≥type-3a) at 1-year follow-up. To account for events occurring before DAPT discontinuation we performed 3-month landmark analysis. RESULTS: 82 patients (5%) were discharged with ≤3-month DAPT (57 ±â€¯27 days), and 1558 patients (94%) were discharged with ≥6-month DAPT (318 ±â€¯75 days). No significant differences between S-DAPT and R-DAPT group were observed in TLF at 1-year (7.9% vs. 4.6%). The rate of BARC major bleeding resulted significantly higher in S-DAPT group (3.9% vs. 0.3%; p = 0.001), with the majority of bleeding events occurring within 3 months. The landmark analysis showed no significant differences in BARC major bleedings between groups (1.4% vs. 0.3%; p = 0.142). CONCLUSIONS: As compared to those treated with R-DAPT (≥6-month), patients needing -S-DAPT (≤3-month) after PCI with Ultimaster® BP-SES had similar rates of 1-year TLF and BARC major bleedings following early DAPT discontinuation.


Assuntos
Implantes Absorvíveis/tendências , Síndrome Coronariana Aguda/terapia , Stents Farmacológicos/tendências , Inibidores da Agregação Plaquetária/administração & dosagem , Sistema de Registros , Sirolimo/administração & dosagem , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Seguimentos , Humanos , Imunossupressores/administração & dosagem , Itália/epidemiologia , Pessoa de Meia-Idade , Polímeros , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
15.
Cardiovasc Revasc Med ; 20(5): 371-375, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30857975

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a well-established treatment option for severe aortic stenosis (AS). AS and coronary artery disease frequently coincide, and therefore some patients may require coronary angiography (CAG) and/or intervention (PCI) post-TAVR. Due to valve stent design, most self-expanding prostheses always cover the coronary ostium, and therefore may hinder future access. The objective of this research was to evaluate the incidence, safety and feasibility of CAG/PCI in patients with prior self-expanding TAVR valves. METHODS: Among 2170 patients (age 82 ±â€¯6 years, 43% male) who underwent TAVR with Corevalve or Evolut prostheses, as part of the Italian CoreValve ClinicalService® framework (data from 13 Italian centers), the occurrence of CAG/PCI following TAVR and periprocedural characteristics were examined. RESULTS: During median follow-up of 379 days, 41 patients (1.9%) required CAG and/or PCI (total 46; 16 CAG, 14 PCI, 16 both PCI/CAG). 56.5% of the procedures were performed under emergency/urgency settings. Left system coronary angiography was successfully performed in most cases (28/32, 87.5%), while right coronary angiography was successful only in 50.0% (16/32). PCI procedures (20 for left system, 3 for right system, 4 for graft) were successfully performed in 93.3% (28/30) of the procedures. No CAG/PCI procedure-related complications including prosthesis dislodgment or coronary ostium dissection occurred. CONCLUSIONS: CAG and PCI procedures following CoreValve TAVR is safe and mostly feasible, although the success rate of selective right coronary angiography was relatively low when compared to the left system. Further investigations are required to explore this issue.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Angiografia Coronária/efeitos adversos , Ponte de Artéria Coronária , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/terapia , Bases de Dados Factuais , Estudos de Viabilidade , Feminino , Humanos , Incidência , Itália/epidemiologia , Masculino , Intervenção Coronária Percutânea , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
16.
Cardiovasc Revasc Med ; 20(12): 1196-1202, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30905659

RESUMO

Mitral stenosis is a rare and potentially severe complication of transcatheter aortic valve replacement (TAVR). Given the anatomic coupling and interdependence of the aortic and mitral valves, it comes by itself that procedures (either surgical or percutaneous) involving the aortic valve imply the risk of altering mitral valve function. Indeed, transcatheter aortic prostheses may impair adequate anterior mitral leaflet (AML) opening, especially when implanted in a "low" position, thus resulting in high transvalvular gradients. Hereby, we report the case of a 71-year-old male with symptomatic severe aortic stenosis and a history of previous surgical mitral valve repair who underwent TAVR with a self-expandable prosthesis. Notwithstanding an acceptable angiographic position, the prosthetic frame was shown to interfere with the AML, as evidenced by augmented transmitral gradients; nonetheless, pulmonary artery pressures remained unchanged, and the patient experienced symptomatic improvement. Therefore, a conservative approach was chosen and the patient was discharged home after medical therapy optimization. Moreover, we provide a review of the available literature regarding the incidence, predictors and possible management of this infrequent complication.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Hemodinâmica , Estenose da Valva Mitral/etiologia , Valva Mitral/fisiopatologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Tratamento Conservador , Próteses Valvulares Cardíacas , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/fisiopatologia , Estenose da Valva Mitral/terapia , Desenho de Prótese , Recuperação de Função Fisiológica , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
17.
G Ital Cardiol (Rome) ; 19(3): 191-193, 2018 Mar.
Artigo em Italiano | MEDLINE | ID: mdl-29873647

RESUMO

Coronary artery disease and aortic stenosis frequently coexist. The pathophysiology of both conditions is similar where atherosclerosis is the hallmark feature. Risk factors for aortic stenosis are also similar for coronary artery disease. The standard therapy in the past decades has been coronary artery bypass grafting and aortic valve replacement; however, with the introduction of transcatheter aortic valve implantation their management is probably going to shift towards a percutaneous strategy.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/cirurgia , Idoso , Estenose da Valva Aórtica/complicações , Doença da Artéria Coronariana/complicações , Humanos , Masculino , Índice de Gravidade de Doença , Procedimentos Cirúrgicos Vasculares/métodos , Disfunção Ventricular Esquerda/complicações
18.
Circ Cardiovasc Interv ; 10(5)2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28500135

RESUMO

BACKGROUND: The benefits and harms of dual antiplatelet therapy (DAPT) continuation beyond 1 year after drug-eluting stent implantation as compared with 1-year DAPT remain controversial. METHODS AND RESULTS: We searched for randomized trials that compared longer than 1-year DAPT versus 1-year DAPT after drug-eluting stenting. A meta-analysis was performed by using standard frequentist and random-effects Bayesian approaches. Four trials comprising 17 650 participants were included. Compared with 1-year DAPT, extended DAPT did not affect all-cause mortality (odds ratio [OR], 1.11; 95% confidence interval [CI], 0.79-1.5; P=0.53) or cardiovascular mortality (OR, 1.03; 95% CI, 0.72-1.46; P=0.88). Extended DAPT was associated with a reduction in the risk of myocardial infarction (OR, 0.56; 95% CI, 0.43-0.73; P<0.001), nonsignificant reductions of stent thrombosis (OR, 0.46; 95% CI, 0.16-1.27; P=0.13), similar risk of stroke (OR, 0.91; 95% CI, 0.65-1.26; P=0.56), and an increased risk of major bleeding (OR, 1.49; 95% CI, 1.06-2.11; P=0.02). By using Bayesian meta-analysis, we found moderate evidence of a reduction of myocardial infarction (OR, 0.62; 95% credible intervals, 0.39-1.05) and weak evidence of an increase in major bleeding (OR, 1.66; 95% credible intervals, 0.89-3.09) associated with extended DAPT. CONCLUSIONS: In this meta-analysis, extended DAPT beyond 1 year prevented myocardial infarctions and increased major bleedings, but the strength of evidence for these effects was not strong. DAPT continuation beyond 1 year showed no effects on mortality.


Assuntos
Aspirina/administração & dosagem , Doença das Coronárias/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Inibidores da Agregação Plaquetária/administração & dosagem , Antagonistas do Receptor Purinérgico P2Y/administração & dosagem , Idoso , Aspirina/efeitos adversos , Teorema de Bayes , Distribuição de Qui-Quadrado , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/mortalidade , Trombose Coronária/etiologia , Esquema de Medicação , Quimioterapia Combinada , Feminino , Hemorragia/induzido quimicamente , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/efeitos adversos , Antagonistas do Receptor Purinérgico P2Y/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
19.
Am J Cardiol ; 119(12): 1942-1948, 2017 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-28433215

RESUMO

Few randomized controlled trials (RCTs) and observational studies had shown acceptable short-term efficacy and safety of percutaneous coronary intervention (PCI) with drug-eluting stents (DES) compared with coronary artery bypass grafting (CABG) in selected patients with left main coronary artery disease (LMCAD). We aimed to evaluate long-term outcomes of PCI using DES compared with CABG in patients with LMCAD. On November 1, 2016, we searched available databases for published RCTs directly comparing DES PCI with CABG in patients with LMCAD. Odds ratios (ORs) were used as the metric of choice for treatment effects using a random-effects model. I-squared index was used to assess heterogeneity across trials. Prespecified end points were all-cause mortality, cardiovascular mortality, myocardial infarction (MI), stroke, and repeat revascularization at maximal available follow-up. We identified 5 RCTs including a total of 4,595 patients, with a median follow-up of 60 months. The risk of all-cause mortality (OR 1.01; 95% confidence interval [CI] 0.76 to 1.34) and cardiovascular mortality (OR 1.02; 95% CI 0.73 to 1.42) were comparable between PCI with DES and CABG. Similarly, there were no statistically significant differences between PCI with DES and CABG for MI (OR 1.45; 95% CI 0.87 to 2.40) and stroke (OR 0.87; 95% CI 0.38 to 1.98). Conversely, repeat revascularization was significantly higher with PCI compared with CABG (OR 1.82; 95% CI 1.51 to 2.21). In conclusion, in patients with LMCAD, PCI with DES appears to be a viable alternative to CABG at long-term follow-up, with similar risks of ischemic adverse events (mortality, MI, and stroke) but a higher risk of repeat revascularization.


Assuntos
Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto
20.
Int J Cardiol ; 240: 92-96, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28318657

RESUMO

BACKGROUND: Interventional radiology and cardiology procedures contribute significantly to the collective dose of radiation exposure from medical interventions. Recent and dedicated studies comparing directly these procedures in term of patient radiation exposure are lacking. Our aim was to compare radiation exposure among different interventional procedures performed under fluoroscopic guidance. METHODS: The RODEO study (NCT: 02972736) is an international observational retrospective multicenter study enrolling all patients undergoing diagnostic or interventional procedures performed by different interventional operators (i.e. radiologists, interventional cardiologists or electrophysiologists) in 6 centers, without exclusion criteria. The primary end-point of the study was the comparison of dose area product (DAP) among interventional cardiology, electrophysiology or interventional radiology procedures. RESULTS: A total of 17,711 procedures were included in the study: 13,522 interventional cardiology, 2352 electrophysiology and 1864 interventional radiology procedures. The highest DAP values were observed for interventional radiology procedures (74Gy∗cm2 [Interquartile range 27-178Gy∗cm2]), followed by interventional cardiology (40Gy∗cm2 [22-78Gy∗cm2]) and electrophysiology procedures (13Gy∗cm2 [4-44Gy∗cm2], p<0.0001). In term of specific procedures, the highest DAP values were observed in structural or valvular cardiac procedures (134Gy∗cm2 [51-260Gy∗cm2]) whereas the lowest DAP values in pacemaker insertion (11Gy∗cm2 [4-28Gy∗cm2]). CONCLUSION: In this large multicenter study, the highest radiation exposure was observed in procedures performed by interventional radiologists. However, among specific procedures, structural or valvular cardiac procedures were associated with the highest radiation exposure.


Assuntos
Procedimentos Endovasculares/efeitos adversos , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Exposição à Radiação/prevenção & controle , Monitoramento de Radiação/métodos , Radiologistas , Idoso , Idoso de 80 Anos ou mais , Procedimentos Endovasculares/normas , Feminino , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/normas , Exposição à Radiação/normas , Monitoramento de Radiação/normas , Radiologistas/normas , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA