Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 25(1): 522, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38970051

RESUMO

BACKGROUND: For the treatment of coronoid process fractures, medial, lateral, anterior, anteromedial, and posterior approaches have been increasingly reported; however, there is no general consensus on the method of fixation of coronal fractures. Here, we present a highly-extensile minimally invasive approach to treat coronoid process fractures using a mini-plate that can achieve anatomic reduction, stable fixation, and anterior capsular repair. Further, the study aimed to determine the complication rate of the anterior minimally invasive approach and to evaluate functional and clinical patient-reported outcomes during follow-up. METHODS: Thirty-one patients diagnosed with coronoid fractures accompanied with a "terrible triad" or posteromedial rotational instability between April 2012 and October 2018 were included in the analysis. Anatomical reduction and mini-plate fixation of coronoid fractures were performed using an anterior minimally invasive approach. Patient-reported outcomes were evaluated using the Mayo Elbow Performance Index (MEPI) score, range of motion (ROM), and the visual analog score (VAS). The time of fracture healing and complications were recorded. RESULTS: The mean follow-up time was 26.7 months (range, 14-60 months). The average time to radiological union was 3.6 ± 1.3 months. During the follow-up period, the average elbow extension was 6.8 ± 2.9° while the average flexion was 129.6 ± 4.6°. According to Morrey's criteria, 26 (81%) elbows achieved a normal desired ROM. At the last follow-up, the mean MEPI score was 98 ± 3.3 points. There were no instances of elbow instability, elbow joint stiffness, subluxation or dislocation, infection, blood vessel complications, or nerve palsy. Overall, 10 elbows (31%) experienced heterotopic ossification. CONCLUSION: An anterior minimally invasive approach allows satisfactory fixation of coronoid fractures while reducing incision complications due to over-dissection of soft tissue injuries. In addition, this incision does not compromise the soft tissue stability of the elbow joint and allows the patient a more rapid return to rehabilitation exercises.


Assuntos
Placas Ósseas , Articulação do Cotovelo , Fixação Interna de Fraturas , Fraturas Cominutivas , Amplitude de Movimento Articular , Fraturas da Ulna , Humanos , Masculino , Feminino , Fraturas da Ulna/cirurgia , Fraturas da Ulna/diagnóstico por imagem , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Pessoa de Meia-Idade , Adulto , Fraturas Cominutivas/cirurgia , Fraturas Cominutivas/diagnóstico por imagem , Articulação do Cotovelo/cirurgia , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/fisiopatologia , Resultado do Tratamento , Estudos Retrospectivos , Seguimentos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Consolidação da Fratura , Idoso , Medidas de Resultados Relatados pelo Paciente , Adulto Jovem
2.
IEEE J Transl Eng Health Med ; 12: 162-170, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38088990

RESUMO

The accuracy of screw placement is a key factor for the stability of the cannulated screws used in the fixation of femoral neck fractures. In this study we designed a navigation device for ensuring the screw reaches the ideal position for optimal fixation. From March 2019 to September 2020, 66 patients with femoral neck fracture were enrolled and divided into 2 groups, one group was treated using the traditional free-hand cannulated screw fixation and the other using the new navigation device with assisted fixation. The effectiveness of the 2 methods was compared based on surgery duration, intraoperative bleeding, number of fluoroscopic examination and guidewire insertion attempts, screw parallelism, and effective fixation area. Fracture healing, complications and hip joint function were assessed after operation. The new navigation device reduced the duration of surgery without causing additional intraoperative bleeding, and significantly reduced number of fluoroscopy examination and guidewire insertion attempts (4.00±1.58 vs. 6.09±1.94 with traditional surgery). The accuracy of screw implantation was improved, as demonstrated by increased screw parallelism (0.71±0.57° vs. 1.66 ±1.01° with traditional surgery) and higher effective fixed area (64.88±10.52 vs. 58.61±9.19 mm2 with traditional surgery). In the postoperative follow-up, except for one case of femoral head necrosis and one case of bone nonunion in the traditional surgical group, the other patients showed fracture healing. There was no significant difference in hip joint function between the 2 groups. The new navigation device enables rapid and accurate guidewire positioning for cannulated screw fixation through simple operation procedures, resulting in good prospect for clinical transformation.


Assuntos
Fraturas do Colo Femoral , Fixação Interna de Fraturas , Humanos , Parafusos Ósseos , Fraturas do Colo Femoral/diagnóstico por imagem , Cabeça do Fêmur , Fluoroscopia
3.
J Orthop Surg Res ; 18(1): 913, 2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38031095

RESUMO

BACKGROUND: Our experience with the surgical flip-dislocation of the bicolumnar (SFDB) approach for type AO 13C3 humeral fractures indicates that this surgical approach can be performed safely and effectively in appropriately selected patients. We aimed to evaluate the clinical outcomes of the SFDB approach without olecranon osteotomy (OO) for type AO 13C3 distal humeral fractures. METHODS: We retrospectively reviewed 65 cases of type AO 13C3 distal humeral fractures treated between April 2008 and July 2018; 33 patients were treated with the SFDB approach, and the remaining were treated with OO. Propensity score matching was used to control for sex, age, and the American Society of Anesthesiology score. Elbow pain, range of motion, stability, and function were assessed using the Mayo Elbow Performance Index (MEPI) and the Disabilities of the Arm, Shoulder, and Hand questionnaire. Clinical complications, reoperation rates, and radiographic results were compared between the groups. RESULTS: Operative time and blood loss were significantly lower in the SFDB group than in the OO group (P = 0.001, P = 0.002, respectively). At the final follow-up, the mean postoperative MEPI did not significantly differ between the groups (P = 0.628). According to Morrey's criteria, a typical functional range of elbow motion was achieved in 12 and 15 patients in the SFDB and OO groups, respectively. CONCLUSIONS: The SFDB approach achieves superior exposure of the articular surface without injury to the extensor mechanism in type 13C3 articular surface fracture treatment. This approach also results in good early functional recovery and clinical outcomes, with a low risk of complications.


Assuntos
Articulação do Cotovelo , Fraturas Distais do Úmero , Fraturas do Úmero , Luxações Articulares , Olécrano , Humanos , Olécrano/cirurgia , Estudos de Coortes , Estudos Retrospectivos , Resultado do Tratamento , Fixação Interna de Fraturas/métodos , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/cirurgia , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/cirurgia , Osteotomia/métodos , Amplitude de Movimento Articular , Luxações Articulares/etiologia
4.
J Bone Joint Surg Am ; 104(23): 2074-2082, 2022 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-36137071

RESUMO

BACKGROUND: Anterior pelvic ring injuries can be treated via Pfannenstiel, modified Stoppa, or ilioinguinal approaches, but these require exposing the abdominal soft tissues and may damage pelvic organs. The scar on the abdominal wall is also unacceptable for some patients. The minimally invasive anterior pelvic ring internal fixator (INFIX) is not ideal for thin patients with easily irritated skin, and it is associated with complications such as femoral nerve palsy, vascular occlusion, and lateral femoral cutaneous nerve injury. In this study, we designed a new external pelvic approach for the treatment of an anterior pelvic ring fracture. METHODS: We retrospectively reviewed 28 patients with 36 pubic ramus fractures that had been treated via the covert-inferior pelvic approach. All patients underwent a surgical procedure between August 2019 and January 2021. According to the Nakatani classification, there were 6 cases of type-I fracture, 25 cases of type-II fracture, and 5 cases of type-III fracture. Operative time, blood loss, and postoperative radiographic and computed tomographic (CT) findings were recorded. Patients were followed for fracture healing time, functional status, esthetic satisfaction, and complications. RESULTS: A total of 27 patients had follow-up for at least 12 months (range, 12 to 29 months). Postoperative radiographs and CT scans showed well-positioned plates and screws. The mean preoperative time was 9.4 ± 3.8 days, the mean operative time was 61.3 ± 22.67 minutes, the mean intraoperative blood loss was 63.6 ± 42.62 mL, the mean fracture healing time was 4.1 ± 1.6 months, and the mean Majeed score was 89.74 ± 8.07. There were no complications of nonunion, internal fixation failure, vascular injury, nerve palsy, or hernia. All of the patients were esthetically satisfied with the scar. CONCLUSIONS: The covert-inferior pelvic approach combined with a subpubic plate effectively fixed Nakatani type-I, II, and III fractures. The advantages of this method include rapid recovery after the surgical procedure, safety, simplicity, a short learning curve, no damage to abdominal soft tissue, no effect on pubic symphysis micromotion, and esthetic benefits. It may be another option for anterior pelvic ring fractures and can supplement other approaches. LEVEL OF EVIDENCE: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Pelve , Humanos , Estudos Retrospectivos , Pelve/lesões , Pelve/cirurgia
5.
Eur J Med Res ; 27(1): 31, 2022 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-35236403

RESUMO

OBJECTIVE: Floating knee type IIC, according to Fraser's classification, is an uncommon severe injury that typically occurs in polytrauma. In such cases, intra-articular fracture and the high degree of comminution and deformity of the mid-distal femur make fixation challenging. The purpose of this study was to demonstrate that minimally invasive plate osteosynthesis (MIPO) technology can simplify these complex problems and improve patient prognosis. CASE PRESENTATION: A 38-year-old man injured his left leg in a car accident, causing pain, swelling, deformity, and limited mobility on his left knee and thigh, and two small open wounds were noted mainly of the anterior aspect of the mid-distal thigh. Physical examination and computed tomography angiography of the lower limb confirmed that there was no damage to the neurovascular system. The clinical diagnosis was closed intra-articular fracture of the proximal tibia, open intra-articular fracture of the distal femur with extension to the diaphysis, and a patellar fracture on the ipsilateral knee. The treatment strategy involved a locking plate system applying MIPO technology. Postoperative evaluation of the patient was satisfactory, with immediate functional exercise, full weight-bearing after three months, and return to daily activity without pain. Final follow-up taken 3 years after surgery showed good lower limb alignment and complete plasticity of the bone structure, by which time the patient showed good limb function. CONCLUSIONS: Minimally invasive techniques can provide a simple and effective treatment for some complex fractures.


Assuntos
Placas Ósseas , Fraturas do Fêmur/cirurgia , Consolidação da Fratura , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fraturas da Tíbia/cirurgia , Suporte de Carga/fisiologia , Adulto , Fraturas do Fêmur/diagnóstico , Fraturas do Fêmur/fisiopatologia , Humanos , Masculino , Fraturas da Tíbia/diagnóstico , Fraturas da Tíbia/fisiopatologia , Tomografia Computadorizada por Raios X
6.
Electron. j. biotechnol ; 52: 52-58, July. 2021. tab, ilus
Artigo em Inglês | LILACS | ID: biblio-1283505

RESUMO

BACKGROUND: Osteoporosis attacks approximately 10% of the population worldwide. Sika Deer (Cervus nippon), one of China's precious traditional medicinal animals, has been widely recorded in ancient Chinese medical books and claimed for centuries to have numerous medical benefits including bone strengthening. This study aimed to find the use of Sika Deer bone in treating osteoporosis according to traditional records and to investigate the protective effect of Sika Deer bone polypeptide extract on glucocorticoidinduced osteoporosis (GIOP) in rats. RESULTS: Sika Deer bone polypeptide extract could increase serum Ca2+ and BGP, decrease serum P3+, ALP, PTH, and CT, but had no effect on serum NO in rats with GIOP. The immunohistochemical iNOS results of the rats' distal femur were negative in each group. Besides the model group, the eNOS color reaction in osteoblasts was strongly positive in the other three groups. CONCLUSIONS: Sika Deer bone polypeptide extract can improve pathological changes in the microstructure and stimulate the expression of eNOS in osteoblasts. The protective effect on bone might be mediated by eNOS-dependent NO generation.


Assuntos
Animais , Masculino , Ratos , Osteoporose/prevenção & controle , Peptídeos/farmacologia , Osso e Ossos/metabolismo , Cervos , Osteoblastos , Dexametasona , Ratos Wistar , Óxido Nítrico Sintase Tipo III/efeitos dos fármacos
7.
BMC Musculoskelet Disord ; 21(1): 176, 2020 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-32188447

RESUMO

BACKGROUNDS: Poor prognosis was reported for complex Pilon fractures involving severe soft tissue damage. It is therefore useful to explore the evolution of different treatment strategies in an effort to reconstruct the axial alignment and articular surface, while minimizing additional damage to the surrounding soft tissues. METHODS: Seventeen patients with Pilon fractures were enrolled in this retrospective study from December 2009 to October 2014. The injuries were graded according to AO Classification and the Gustilo-Anderson system. Patients were treated with minimally invasive plate osteosynthesis (MIPO) combined with curved incision on the anterior area of ankle. The ankle function and radiological outcome were assessed by the modified Mazur ankle score and Burwell-Charnley criteria, respectively. Visual analogue score (VAS) score was used to assess the degree of patient's ankle pain, and related complications were also recorded. RESULTS: The mean time for fracture healing was 3.6 months (range: 3-6 months). According to Mazur's criteria, surgical treatment achieved good or excellent outcome in 15 (88.2%) cases, and the average VAS score was 1.19 ± 0.52. On the basis of Burwell-Charnley score, 12 (70.5%) patients achieved anatomic recovery, 4 (23.5%) obtained good reduction, and only 1 (5.9%) patient was diagnosed with valgus deformity. Additionally, 1 (5.9%) patient developed a superficial infection around incision, and 2 (11.8%) experienced superficial peroneal nerve damage. In addition, 2 (11.8%) patients showed radiographic evidence of existing ankle osteoarthritis at the final follow-up. CONCLUSIONS: This retrospective study is the first to assess the application of a curved incision on the anterior area of ankle with MIPO for the treatment of Pilon fractures, which achieves high functional recovery with a low complication rate. However, large randomized controlled trials comparing different approaches and fixation methods are still needed to conclusively identify the optimal treatment protocol.


Assuntos
Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Fixação Interna de Fraturas/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Adulto , Placas Ósseas , Terapia Combinada/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
8.
Med Sci Monit ; 25: 5997-6006, 2019 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-31402352

RESUMO

BACKGROUND Established tibial nonunions rarely heal without secondary intervention; revision surgery is the most common intervention. Herein, we evaluated the clinical outcomes of patients with tibial nonunion treated with a new technique - minimally invasive percutaneous plate osteosynthesis (MIPPO) - combined with a new onionskin-like autologous bone grafting method. MATERIAL AND METHODS From 2010 to 2013, 18 patients with tibial nonunions (average bone defect: 9.5 mm) were treated with MIPPO technology combined with onionskin-like autologous bone grafting. Indices for clinical evaluation included operative time, fluoroscopy time, blood loss, hospital stay, healing time, postoperative complaints, radiographic performances, the Short Musculoskeletal Function Assessment (SMFA) questionnaire, and the American Orthopedic Foot & Ankle Society (AOFAS) ankle-hindfoot score. RESULTS The average operation and fluoroscopy times for tibial nonunion were 65 min and 15.5 s, respectively, with a total blood loss of 107.7 mL. The mean duration of hospital stay was 12.8 days. The mean follow-up time was 11.9 months, and all patients achieved radiologically confirmed bony healing in an average time of 13.1 weeks. No lower-leg deformity, fixation failure, infection, and vascular, or nerve injuries were recorded in any patient, and only 4 patients complained of slight limb pain upon total weight-bearing at the end of follow-up. The SMFA and AOFAS ankle-hindfoot scores of patients were graded excellent in 14 (77.8%) and good in 4 (22.2%), indicating high functional recovery. CONCLUSIONS MIPPO technology combined with onionskin bone grafting is an efficient method to treat patients with tibial nonunion, especially for patients with poor soft tissue condition.


Assuntos
Transplante Ósseo/métodos , Cementoplastia/métodos , Fixação Interna de Fraturas/métodos , Adulto , Placas Ósseas , Consolidação da Fratura , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Duração da Cirurgia , Reoperação/métodos , Tíbia/fisiopatologia , Tíbia/cirurgia , Fraturas da Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA