Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 336
Filtrar
1.
Biosens Bioelectron ; 266: 116726, 2024 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-39226752

RESUMO

The oriented design of reticular materials as emitters can significantly enhance the sensitivity of electrochemiluminescence (ECL) sensing analysis for disease markers. However, due to the structural fragility of hydrogen bonds, relational research on hydrogen-bonded organic frameworks (HOFs) has not been thoroughly conducted. Additionally, the modulation of luminescence behavior through HOFs has been rarely reported. In view of this, hydrogen-bonded biohybrid organic frameworks (HBOFs) were synthesized and recruited for ECL immunoassay applications. HBOFs was easily prepared using 6,6',6″,6‴-(pyrene-1,3,6,8-tetrayl)tetrakis(2-naphthoic acid) as linkers via bovine serum albumin (BSA) activated hydrogen-bonded cross-linking. The material exhibited good fluorescence emission characteristics. And the highly ordered topological structure and molecular motion limitation mediated by BSA overcome aggregation-caused quenching and generate strong aggregation induced emission, expressing hydrogen-bond interaction enhanced ECL (HIE-ECL) activity with the participation of tri-n-propylamine. Furthermore, a sandwich immunosensor was constructed employing cobalt-based metal-phenolic network (CMPN) coated ferrocene nanoparticles (FNPs) as quenchers (CMPN@FNPs). Signal closure can be achieved by annihilating the excited state through electron transfer from both CMPN and FNPs. Using a universal disease marker, carcinoembryonic antigen, as the analysis model, the signal-off sensor obtained a detection limit of 0.47 pg/mL within the detection range of 1 pg/mL - 50 ng/mL. The synthesis and application of highly stable HBOFs triggered by proteins provide a reference for the development of new reticular ECL signal labels, and electron transfer model provides flexible solutions for more sensitive sensing analysis.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Ligação de Hidrogênio , Medições Luminescentes , Soroalbumina Bovina , Técnicas Biossensoriais/métodos , Imunoensaio/métodos , Técnicas Eletroquímicas/métodos , Medições Luminescentes/métodos , Humanos , Soroalbumina Bovina/química , Animais , Estruturas Metalorgânicas/química , Limite de Detecção , Bovinos , Metalocenos/química , Compostos Ferrosos/química , Anticorpos Imobilizados/química , Biomarcadores/análise , Cobalto/química
2.
Anal Chem ; 96(37): 14926-14934, 2024 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-39219294

RESUMO

In conventional metal-organic framework (MOF) luminophore-involved electrochemiluminescence (ECL) systems, the aggregation-caused quenching commonly exists for the organic luminescent ligands, limiting the ECL efficiency and detection sensitivity. Herein, by employing the aggregation-induced emission luminogen (AIEgen) 1,1,2,2-tetra(4-carboxylbiphenyl)ethylene (H4TCBPE) as a ligand, one high-efficiency ECL emitter (Zr-MOF) was synthesized through a simple hydrothermal reaction. Compared with H4TCBPE monomers and their aggregates, the resultant Zr-MOF possesses the strongest ECL emission, which is mainly attributed to the framework-induced ECL enhancement. Specifically, the heterostructure was prepared by the deposition of silver nanoparticles on TiO2 microflowers and utilized as an efficient coreaction accelerator. Remarkably, the formative heterojunction can increase the interfacial charge transfer efficiency and promote the carrier separation, facilitating the oxidation of coreactant tripropylamine. In this way, a novel aptamer-mediated ECL sensing platform is constructed, achieving the sensitive analysis of adenosine triphosphate with a low detection limit of 0.17 nM. As a proof-of-concept study, this work may enlighten the rational design of new-type MOF-based ECL materials and expand the application scope of the ECL technology.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Medições Luminescentes , Nanopartículas Metálicas , Estruturas Metalorgânicas , Prata , Titânio , Titânio/química , Prata/química , Estruturas Metalorgânicas/química , Técnicas Biossensoriais/métodos , Nanopartículas Metálicas/química , Limite de Detecção , Trifosfato de Adenosina/análise , Aptâmeros de Nucleotídeos/química , Zircônio/química
3.
J Orthop Surg Res ; 19(1): 461, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39095911

RESUMO

BACKGROUND: Trigger thumb is a prevalent hand condition observed in children, and its management remains a topic of considerable debate, ranging from mere observation to surgical intervention. In recent times, there has been a growing interest in exploring nonoperative treatments as alternatives to surgical procedures for managing pediatric trigger thumb. Gaining insight into the prevalence of spontaneous resolution in pediatric trigger thumb is of paramount importance. However, the literature presents a wide variation in estimates regarding the prevalence of this spontaneous resolution, highlighting the need for further investigation and consensus. The aim of this review was to estimate the overall prevalence of spontaneous resolution among pediatric trigger thumb. METHODS: This study meticulously followed the PRISMA guidelines and registered in the PROSPERO. The PubMed, Embase, and Cochrane Library databases were searched for all relevant studies up to May 2024.Inclusion criteria were studies reported only observation spontaneous resolution pediatric trigger thumb, aged up to 14 years, reported at least 10 thumbs and followed up time at least 3 months. Confounded intervention treatment measure studies were excluded. To synthesize the prevalence rates from individual studies, we employed a random-effects meta-analysis. In order to uncover the sources of heterogeneity and to compare prevalence estimates across different groups, we performed sensitivity and subgroup analyses. To meticulously evaluate the quality of the included studies, the Joanna Briggs Institute's quality assessment checklist was employed. Furthermore, to assess the heterogeneity among the studies, both Cochran's Q test and the I² statistic were utilized. RESULTS: A total of eleven studies were included for the final analysis, with 599 pediatric trigger thumbs. Our final meta-analysis showed that more than one-third of these pediatric trigger thumb cases resolved spontaneously, with a resolution rate of 43.5% (95% CI 29.6-58.6). Subgroup analyses showed that in terms of age at the first visit, the prevalence of spontaneous resolution in the less than 24 months group and in the 24 months or older group was 38.7%(95% CI 18.1-64.4)and 45.8%(95% CI 27.4-65.4), respectively. There was no significant difference between the two groups(P = 0.690). When analyzing follow up time, the prevalence of spontaneous resolution in the 24 months or longer group and in the less than 24 months group was 58.9%(95% CI 41.6-74.2)and 26.8%(95% CI 14.7-43.8), respectively.There was significant statistical differences between the two groups(P = 0.009). Based on the initial severity of interphalangeal (IP) joint flexion contracture, the prevalence of spontaneous resolution in the 30 degrees or less group and in the other measurements group was 54.1%(95% CI 31.5-75.1)and 37.1%(95% CI 21.9-55.4), respectively.There was no significant difference between the two groups(P = 0.259). CONCLUSION: Our study demonstrates that a significant proportion of pediatric trigger thumbs resolve spontaneously. This finding highlights the benefits of early observation in managing this condition. By prioritizing non-operative observation, both parents and surgeons are better equipped to make informed decisions regarding the treatment of pediatric trigger thumb, potentially reducing the need for surgical intervention.


Assuntos
Remissão Espontânea , Dedo em Gatilho , Humanos , Dedo em Gatilho/epidemiologia , Criança , Prevalência , Adolescente , Pré-Escolar , Feminino , Masculino , Lactente
4.
Zhong Nan Da Xue Xue Bao Yi Xue Ban ; 49(5): 818-824, 2024 May 28.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-39174896

RESUMO

Actinomycosis is a rare chronic granulomatous disease characterized by granuloma formation and tissue fibrosis with sinus tracts, often misdiagnosed due to its similarity to many infectious and non-infectious diseases. This report presents a case of a 60-year-old female with more than 10 years history of rheumatoid arthritis who developed actinomycosis infection after long-term treatment with immunosuppressants and biologics, including methotrexate, leflunomide, and infliximab, leading to recurrent joint pain, poorly controlled rheumatoid arthritis activity, and persistent elevation of white blood cell counts. Abdominal CT revealed a pelvic mass and right ureteral dilation. Pathological examination of cervical tissue showed significant neutrophil infiltration and sulfur granules, indicating actinomycosis. The patient received 18 months of doxycycline treatment for the infection and continued rheumatoid arthritis therapy with leflunomide, hydroxychloroquine sulfate, and tofacitinib, resulting in improved joint symptoms and normalized white blood cell counts. After 2 years of follow-up, the patient remained stable with no recurrence. This case highlights the importance of clinicians being vigilant for infections, particularly chronic, occult infections from rare pathogens, in rheumatoid arthritis patients on potent immunosuppressants and biologics, advocating for early screening and diagnosis.


Assuntos
Actinomicose , Artrite Reumatoide , Obstrução Ureteral , Humanos , Feminino , Artrite Reumatoide/complicações , Artrite Reumatoide/tratamento farmacológico , Pessoa de Meia-Idade , Actinomicose/diagnóstico , Actinomicose/complicações , Actinomicose/tratamento farmacológico , Obstrução Ureteral/etiologia , Imunossupressores/uso terapêutico
5.
Front Pediatr ; 12: 1418616, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39040666

RESUMO

Background: Retroperitoneal lymphatic malformations (LMs) are rare. Currently, the treatment of retroperitoneal LMs remains challenging. This study aimed to examine the safety and efficacy of laparoscopic-assisted sclerotherapy for retroperitoneal LMs in pediatric patients. Methods: We retrospectively reviewed patients treated with laparoscopic-assisted sclerotherapy for retroperitoneal LMs in a single tertiary medical center between July 2020 and February 2023. Doxycycline was prepared into a solution with a concentration of 10 mg/ml for use in sclerotherapy. Demographic data, clinical features, details of management, and outcomes were collected and analyzed. Results: A total of six patients, comprising three males and three females, were identified. The LMs were categorized into four macrocystic and two mixed-cystic types. The mean age and weight were 52.2 months (range, 11-108 months) and 20 kg (range, 12.5-27.5 kg), respectively. Three patients presented with abdominal pain or distension, while the other three patients were asymptomatic. All six patients underwent a total of eight sclerotherapy sessions. Two patients experienced intra-cystic hemorrhage and required a second sclerotherapy session. Only one patient presented with vomiting after sclerotherapy, which resolved spontaneously. Five patients met the complete response criteria, and one patient met the effective criteria. The mean reduction in lesion size was 92.3% (range, 69.9%-99.6%). No further complications or recurrence were recorded during follow-up. Conclusion: Laparoscopic-assisted sclerotherapy is a safe and effective approach for treating retroperitoneal LMs. This technique is applicable for both macrocystic and mixed-cystic retroperitoneal LMs.

6.
Biotechnol Bioeng ; 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39081029

RESUMO

Gallic acid (GA) and ß-glucogallin (BGG) are natural products with diverse uses in pharmaceutical, food, chemical and cosmetic industries. They are valued for their wide-ranging properties such as antioxidant, antibacterial, antidiabetic, and anticancer properties. Despite their significant importance, microbial production of GA and BGG faces challenges such as limited titers and yields, along with the incomplete understanding of BGG biosynthesis pathways in microorganisms. To address these challenges, we developed a recombinant Escherichia coli strain capable of efficiently producing GA. Our approach involved screening efficient pathway enzymes, integrating biosynthetic pathway genes into the genome while balancing carbon flux via adjusting expression levels, and strengthening the shikimate pathway to remove bottlenecks. The resultant strain achieved impressive results, producing 51.57 g/L of GA with a carbon yield of 0.45 g/g glucose and a productivity of 1.07 g/L/h. Furthermore, we extended this microbial platform to biosynthesize BGG by screening GA 1-O-glucosyltransferase, leading to the de novo production of 92.42 mg/L of BGG. This work establishes an efficient chassis for producing GA at an industrial level and provides a microbial platform for generating GA derivatives.

7.
Front Cell Infect Microbiol ; 14: 1355397, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39081867

RESUMO

Aims: This study is designed to generalize and depict the research hotspots of endophthalmitis through bibliometric methods and software and analyze the evolutive tendency of the work on this severe disease over the past 30 years. Methods: This study employed a rigorous bibliometric approach. We identified all endophthalmitis-related literature by conducting a comprehensive search of the Science Citation Index Expanded database under the Web of Science Core Collection. The data was then analyzed and visualized using CiteSpace and VOSviewer, two widely recognized software tools in the field of bibliometrics. CiteSpace was used to analyze the country distributions, dual map overlay of journals, keyword bursts, and co-cited references. VOSviewer was employed to describe the authors and co-cited authors, the journals, the co-cited journals, and the keywords co-occurrence network. This robust methodology ensures the reliability and validity of the study's findings. Results: A total of 2960 publications, including 2695 articles and 265 reviews, were included in this bibliometric study. There has been no shortage of endophthalmitis-related publications since 1993, with an apparent upward trend during recent years. Possible correlations with the COVID-19 pandemic are also analyzed. These studies were finished by 11,048 authors from 75 countries worldwide, with the United States in the lead. In the keyword co-occurrence network, except for the endophthalmitis term, cataract surgery becomes the keyword with the highest frequency. Different categories of endophthalmitis, including postoperative, post-injection, post-traumatic, and endogenous endophthalmitis, and antibacterial and anti-inflammatory therapies of infectious endophthalmitis, are discussed by categories. From the perspective of the timeline, postoperative and post-injection endophthalmitis were the dominant forms before and after the year 2000, respectively. Co-citation analyses reveal that the Endophthalmitis Vitrectomy Study (EVS) conducted in 1995 provides pivotal guidance for later research. Diverse pathogenic bacteria (e.g., Coagulase-negative Staphylococci, Propionibacterium acnes, Viridians Streptococci, and Bacillus cereus) or fungi (e.g., Candida, Aspergillus, and Fusarium) contribute to varying treatment principles and clinical prognosis, which should be taken seriously. In addition, intravitreal and intracameral antibiotics are the mainstay for treating and preventing infectious endophthalmitis, respectively. Conclusion: Our bibliometric analysis provides an overview of dynamic evolution and structural relationships in the research field of endophthalmitis. The displayed hotspots and developmental directions have reference values for future investigation.


Assuntos
Bibliometria , Endoftalmite , Endoftalmite/epidemiologia , Humanos , COVID-19/epidemiologia , SARS-CoV-2 , Software
8.
BMC Cancer ; 24(1): 921, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39080613

RESUMO

BACKGROUND: Chemoresistance remains a significant challenge in colorectal cancer (CRC) treatment, necessitating a deeper understanding of its underlying mechanisms. HOXC11 has emerged as a potential regulator in various cancers, but its role in CRC chemoresistance remains unclear. METHODS: Sulforhodamine B assay was employed to assess the cell viability of CRC cells following treatment with chemotherapeutic drugs. Immunofluorescence staining was performed to examine the subcellular localization of HOXC11 in normal and chemoresistant CRC cells. The Seahorse mito stress test was conducted to evaluate the mitochondrial respiratory function of CRC cells. Real-time PCR was utilized to measure the expression level and copy number of mitochondrial DNA (mtDNA). RESULTS: Our findings revealed that HOXC11 was overexpressed in CRC cells compared to normal colorectal cells and correlated with poorer prognosis in CRC patients. Knockout of HOXC11 reversed acquired chemoresistance in CRC cells. Furthermore, we observed a functional subset of HOXC11 localized to the mitochondria in chemoresistant CRC cells, which regulated mitochondrial function by modulating mtDNA transcription, thereby affecting chemoresistance. CONCLUSIONS: In summary, our study reveals that HOXC11 regulates mitochondrial function through the modulation of mtDNA transcription, impacting chemoresistance in colorectal cancer cells. These findings underscore the significance of understanding the molecular mechanisms underlying chemoresistance and highlight the potential therapeutic implications of targeting mitochondrial function in CRC treatment.


Assuntos
Neoplasias Colorretais , DNA Mitocondrial , Resistencia a Medicamentos Antineoplásicos , Proteínas de Homeodomínio , Mitocôndrias , Humanos , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/genética , Neoplasias Colorretais/metabolismo , Neoplasias Colorretais/patologia , Resistencia a Medicamentos Antineoplásicos/genética , Mitocôndrias/metabolismo , Proteínas de Homeodomínio/metabolismo , Proteínas de Homeodomínio/genética , DNA Mitocondrial/genética , DNA Mitocondrial/metabolismo , Linhagem Celular Tumoral , Regulação Neoplásica da Expressão Gênica , Prognóstico , Antineoplásicos/farmacologia , Antineoplásicos/uso terapêutico , Sobrevivência Celular/efeitos dos fármacos
9.
Anal Chem ; 96(31): 12593-12597, 2024 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-39041729

RESUMO

In this Letter, a sensitive DNA sensing platform was developed using an indium-ion-coordinated 1,1,2,2-tetra(4-carboxylphenyl)ethylene (TPE) metal-organic gel (In-MOG) as an aggregation-induced electrochemiluminescence (AIECL) emitter and nanosurface energy transfer (NSET) as an efficient quenching strategy for detecting aflatoxin B1 (AFB1), the most dangerous food toxin. The coordination occurred in indium ions, and carboxyl groups restricted the internal rotation and vibration of TPE molecules, forcing them to release photons via radiative transitions. The quenchers of microfluidic-produced gold nanoparticles were embedded in a long-tailed triangular DNA structure, where the quenching phenomenon aligned with the theory of ECL-NSET under the overlap of spectra and appropriate donor-acceptor spacing. The proposed analytical method showed a sensitive ECL response to AFB1 in the wide concentration range of 0.50-200.00 ng/mL with a limit of detection of 0.17 ng/mL. Experimental results confirmed that constraining luminescent molecules using coordination and bonding to trigger the AIECL phenomenon was a promising method to prepare signal labels for the trace detection of food toxins.


Assuntos
Aflatoxina B1 , Técnicas Eletroquímicas , Transferência de Energia , Medições Luminescentes , Aflatoxina B1/análise , Ouro/química , Nanopartículas Metálicas/química , DNA/química , Géis/química , Limite de Detecção
10.
Anal Chem ; 96(27): 11044-11051, 2024 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-38937378

RESUMO

Metal nanoclusters (NCs) as a new kind of luminophore have acquired sufficient interest, but their widespread application is restricted on account of their relatively low electrochemiluminescence (ECL) efficiency. Then, aqueous metal NCs with high ECL efficiency were strongly anticipated, especially for the ultrasensitive analysis of biomarkers. Herein, a near-infrared (NIR) ECL biosensing strategy for the test of neuron-specific enolase (NSE) was proposed by utilizing N-acetyl-l-cysteine (NAC)- and cysteamine (Cys)-stabilized gold NCs (NAC/Cys-AuNCs) as ECL emitters with the NIR ECL emission around 860 nm and a metal-organic framework/palladium nanocubes (ZIF-67/PdNCs) hybrid as the coreaction accelerator through their admirable electrocatalytic activity. The NIR emission would reduce photochemical injury to the samples and even realize nondestructive analysis with highly strong susceptibility and suitability. Furthermore, the utilization of ZIF-67/PdNCs could improve the ECL response of NAC/Cys-AuNCs by facilitating the oxidation of the coreactant triethylamine (TEA), leading to the production of a larger quantity of reducing intermediate radical TEA•+. Consequently, NAC/Cys-AuNCs with ZIF-67/PdNCs displayed 2.7 fold enhanced ECL emission compared with the single NAC/Cys-AuNCs using TEA as the coreactant. In addition, HWRGWVC (HWR), a heptapeptide, was introduced to immobilize antibodies for the specially binding Fc fragment of the antibodies, which improved the binding efficiency and sensitivity. As a result, a "signal-on" immunosensor for NSE analysis was obtained with an extensive linear range of 0.1 to 5 ng/mL and a low limit of detection (0.033 fg/mL) (S/N = 3). This study provides a wonderful method for the development of an efficient nondestructive immunoassay.


Assuntos
Biomarcadores , Técnicas Eletroquímicas , Ouro , Medições Luminescentes , Nanopartículas Metálicas , Estruturas Metalorgânicas , Ouro/química , Estruturas Metalorgânicas/química , Nanopartículas Metálicas/química , Imunoensaio/métodos , Técnicas Eletroquímicas/métodos , Biomarcadores/análise , Cobalto/química , Humanos , Fosfopiruvato Hidratase/análise , Limite de Detecção , Cisteamina/química , Paládio/química , Raios Infravermelhos , Técnicas Biossensoriais/métodos
11.
Anal Chim Acta ; 1310: 342703, 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38811134

RESUMO

BACKGROUND: Photoelectrochemical (PEC) sensors have attracted much attention due to their low cost, simple instrumentation and high sensitivity. However, conventional PEC sensors require layer-by-layer modification of the photoelectrode surface, which has the disadvantages of being time-consuming and unstable. In addition, complex interfering substances in real samples may lead to false-positive or false-negative detection results. It was thought that the above drawbacks could be eliminated by the construction of a polarity inversion PEC sensor. In this work, a magnetically separated PEC sensor was constructed for the detection of Carcinoembryonic antigen (CEA). RESULTS: During the experiment, the construction of the sensor was used for sensitive detection of CEA. In the experimental process, Fe3O4@SiO2@CdS, a semiconductor material with magnetic properties, was chosen as the substrate material, and ZnO/CuO was used as the marker on the DNA2 molecule, and a split magnetic separation PEC sensor was constructed, which was used to realize the sensitive detection of CEA. Eventually, the detection range of the sensor for CEA detection is 1-10000 pg/mL, with the detection limit of 0.34 pg/mL. Additionally, the PEC sensor has the advantages of high speed, high efficiency, high sensitivity, good specificity, and high stability. The sensing platform constructed in this work can also be extended to detect other targets, which provides a new idea for PEC sensing platforms. SIGNIFICANCE: In this experiment, we developed a split PEC immunosensor based on magneto-optic nanostructure and photocurrent polarity switching strategy. Specifically, the proposed magnetic nanostructure Fe3O4@SiO2@CdS-DNA1 exhibits good paramagnetism and dispersion ability. By magnetic separation process, the PEC signals of opposite polarity can be obtained.

12.
Acta Pharmacol Sin ; 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38802569

RESUMO

Graft-versus-host disease (GVHD), an immunological disorder that arises from donor T cell activation through recognition of host alloantigens, is the major limitation in the application of allogeneic hematopoietic stem cell transplantation (allo-HSCT). Traditional immunosuppressive agents can relieve GVHD, but they induce serious side effects. It is highly required to explore alternative therapeutic strategy. Human amniotic epithelial stem cells (hAESCs) were recently considered as an ideal source for cell therapy with special immune regulatory property. In this study, we evaluated the therapeutic role of hAESCs in the treatment of GVHD, based on our previous developed cGMP-grade hAESCs product. Humanized mouse model of acute GVHD (aGVHD) was established by injection of huPBMCs via the tail vein. For prevention or treatment of aGVHD, hAESCs were injected to the mice on day -1 or on day 7 post-PBMC infusion, respectively. We showed that hAESCs infusion significantly alleviated the disease phenotype, increased the survival rate of aGVHD mice, and ameliorated pathological injuries in aGVHD target organs. We demonstrated that hAESCs directly induced CD4+ T cell polarization, in which Th1 and Th17 subsets were downregulated, and Treg subset was elevated. Correspondingly, the levels of a series of pro-inflammatory cytokines were reduced while the levels of the anti-inflammatory cytokines were upregulated in the presence of hAESCs. We found that hAESCs regulated CD4+ subset polarization in a paracrine mode, in which TGFß and PGE2 were selectively secreted to mediate Treg elevation and Th1/Th17 inhibition, respectively. In addition, transplanted hAESCs preserved the graft-versus-leukemia (GVL) effect by inhibiting leukemia cell growth. More intriguingly, hAESCs infusion in HSCT patients displayed potential anti-GVHD effect with no safety concerns and confirmed the immunoregulatory mechanisms in the preclinical study. We conclude that hAESCs infusion is a promising therapeutic strategy for post-HSCT GVHD without compromising the GVL effect. The clinical trial was registered at www.clinicaltrials.gov as #NCT03764228.

13.
Biosens Bioelectron ; 259: 116387, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38754194

RESUMO

The incidence of esophageal cancer is positively associated with fumonisin contamination. It is necessary to develop methods for the rapid detection of fumonisins. In this work, a self-powered photoelectrochemical aptamer sensor based on ZnIn2S4/WO3 photoanode and Au@W-Co3O4 photocathode is proposed for the sensitive detection of fumonisin B1 (FB1). Among them, under visible light irradiation, the Z-type heterostructure of ZnIn2S4/WO3 acts as a photoanode to improve the electron transfer rate, which contributes to the enhancement of the photocathode signal and lays the foundation for a wider detection range. The Au@W-Co3O4 photocathode as a sensing interface reduces the probability of false positives (comparison of anode sensing platforms). The PEC sensor has a good working performance in the detection range (10 pg/mL-1000 ng/mL) with a detection limit of 2.7 pg/mL (S/N = 3). In addition, the sensor offers good selectivity, stability and excellent recoveries in real sample analysis. This work is expected to play a role in the field of analyzing environmental toxins.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Técnicas Eletroquímicas , Fumonisinas , Limite de Detecção , Fumonisinas/análise , Fumonisinas/química , Aptâmeros de Nucleotídeos/química , Tungstênio/química , Eletrodos , Óxidos/química , Ouro/química , Humanos , Luz , Zinco/química
14.
Anal Chem ; 96(21): 8390-8398, 2024 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-38716680

RESUMO

In this work, a microfluidic immunosensor chip was developed by incorporating microfluidic technology with electrochemiluminescence (ECL) for sensitive detection of human epidermal growth factor receptor-2 (HER2). The immunosensor chip can achieve robust reproducibility in mass production by integrating multiple detection units in a series. Notably, nanoscale materials can be better adapted to microfluidic systems, greatly enhancing the accuracy of the immunosensor chip. Ag@Au NCs closed by glutathione (GSH) were introduced in the ECL microfluidic immunosensor system with excellent and stable ECL performance. The synthesized CeO2-Au was applied as a coreaction promoter in the ECL signal amplification system, which made the result of HER2 detection more reliable. In addition, the designed microfluidic immunosensor chip integrated the biosensing system into a microchip, realizing rapid and accurate detection of HER2 by its high throughput and low usage. The developed short peptide ligand NARKFKG (NRK) achieved an effective connection between the antibody and nanocarrier for improving the detection efficiency of the sensor. The immunosensor chip had better storage stability and sensitivity than traditional detection methods, with a wide detection range from 10 fg·mL-1 to 100 ng·mL-1 and a low detection limit (LOD) of 3.29 fg·mL-1. In general, a microfluidic immunosensor platform was successfully constructed, providing a new idea for breast cancer (BC) clinical detection.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Eletrodos , Ouro , Medições Luminescentes , Nanopartículas Metálicas , Receptor ErbB-2 , Prata , Humanos , Receptor ErbB-2/análise , Receptor ErbB-2/imunologia , Nanopartículas Metálicas/química , Técnicas Eletroquímicas/métodos , Prata/química , Técnicas Biossensoriais/métodos , Ouro/química , Imunoensaio/métodos , Técnicas Analíticas Microfluídicas/instrumentação , Limite de Detecção , Cério/química
15.
Anal Chem ; 96(21): 8814-8821, 2024 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-38751335

RESUMO

Highly responsive interface of semiconductor nanophotoelectrochemical materials provides a broad development prospect for the identification of low-abundance cancer marker molecules. This work innovatively proposes an efficient blank WO3/SnIn4S8 heterojunction interface formed by self-assembly on the working electrode for interface regulation and photoregulation. Different from the traditional biomolecular layered interface, a hydrogel layer containing manganese dioxide with a wide light absorption range is formed at the interface after an accurate response to external immune recognition. The formation of the hydrogel layer hinders the effective contact between the heterojunction interface and the electrolyte solution, and manganese dioxide in the hydrogel layer forms a strong competition between the light source and the substrate photoelectric material. The process effectively improves the carrier recombination efficiency at the interface, reduces the interface reaction kinetics and photoelectric conversion efficiency, and thus provides strong support for target identification. Taking advantage of the process, the resulting biosensors are being explored for sensitive detection of human epidermal growth factor receptor 2, with a limit of detection as low as 0.037 pg/mL. Also, this study contributes to the advancement of photoelectrochemical biosensing technology and opens up new avenues for the development of sensitive and accurate analytical tools in the field of bioanalysis.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Compostos de Manganês , Óxidos , Receptor ErbB-2 , Humanos , Técnicas Eletroquímicas/métodos , Óxidos/química , Compostos de Manganês/química , Receptor ErbB-2/imunologia , Receptor ErbB-2/metabolismo , Hidrogéis/química , Processos Fotoquímicos , Limite de Detecção , Eletrodos , Imunoensaio/métodos , Tungstênio/química
16.
Talanta ; 275: 126125, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38663066

RESUMO

The establishment of rapid target analysis methods for cytokeratin fragment antigen 21-1 (CYFRA 21-1) is urgently needed. [Ir(pbi)2(acac)] (pbi = 2-(4-bromophenyl)-1-hydrogen -benzimidazole, acac = acetylacetonate) as traditional electrochemiluminescence (ECL) luminophores has been confined due to its non-negligible dark toxicity and poor water solubility leading to poor biocompatibility and electrical conductivity as an organic molecule. Hence, to overcome this limitation, [Ir(pbi)2(acac)] can be effectively loaded on the polyvinyl alcohol hydrogel modified Ti3C2Tx MXene surface (Ir@Ti3C2Tx-PVA) as sensing platform which can emit high ECL signals. Then, a quenching strategy was proposed to fabricate an ECL sandwich immunosensor using H2O2 as quencher molecules which can generated by Pd@Au0.85Pd0.15. Especially, the generation of O2 to H2O2 can be achieved through a two-electron (2e-) reaction pathway by Pd@Au0.85Pd0.15, to overcome the restriction that the H2O2 was virtually impossible to label or immobilize on the non-enzyme nanomaterials. The proposed ECL assay achieves a response to CYFRA 21-1 within the range of 0.1 pg/mL-100 ng/mL, with a detection limit of 8.9 fg/mL (S/N = 3). This work provided a feasible tactic to seek superior-performance ECL luminophore and quencher consequently set up a novel means to makeup ultrasensitive ECL biosensor, which extended the utilization potential of Ir(pbi)2(acac) in ECL assays.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Ouro , Peróxido de Hidrogênio , Queratina-19 , Medições Luminescentes , Paládio , Álcool de Polivinil , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Técnicas Eletroquímicas/métodos , Paládio/química , Catálise , Técnicas Biossensoriais/métodos , Álcool de Polivinil/química , Ouro/química , Humanos , Medições Luminescentes/métodos , Queratina-19/análise , Imunoensaio/métodos , Antígenos de Neoplasias/análise , Antígenos de Neoplasias/imunologia , Titânio/química , Limite de Detecção , Irídio/química , Nanopartículas Metálicas/química
17.
EMBO J ; 43(10): 1990-2014, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38605226

RESUMO

Prenatal lethality associated with mouse knockout of Mettl16, a recently identified RNA N6-methyladenosine (m6A) methyltransferase, has hampered characterization of the essential role of METTL16-mediated RNA m6A modification in early embryonic development. Here, using cross-species single-cell RNA sequencing analysis, we found that during early embryonic development, METTL16 is more highly expressed in vertebrate hematopoietic stem and progenitor cells (HSPCs) than other methyltransferases. In Mettl16-deficient zebrafish, proliferation capacity of embryonic HSPCs is compromised due to G1/S cell cycle arrest, an effect whose rescue requires Mettl16 with intact methyltransferase activity. We further identify the cell-cycle transcription factor mybl2b as a directly regulated by Mettl16-mediated m6A modification. Mettl16 deficiency resulted in the destabilization of mybl2b mRNA, likely due to lost binding by the m6A reader Igf2bp1 in vivo. Moreover, we found that the METTL16-m6A-MYBL2-IGF2BP1 axis controlling G1/S progression is conserved in humans. Collectively, our findings elucidate the critical function of METTL16-mediated m6A modification in HSPC cell cycle progression during early embryonic development.


Assuntos
Células-Tronco Hematopoéticas , Metiltransferases , Metilação de RNA , Proteínas de Ligação a RNA , Fatores de Transcrição , Peixe-Zebra , Animais , Humanos , Camundongos , Adenosina/análogos & derivados , Adenosina/metabolismo , Adenosina/genética , Ciclo Celular , Proteínas de Ciclo Celular/metabolismo , Proteínas de Ciclo Celular/genética , Proliferação de Células , Desenvolvimento Embrionário/genética , Regulação da Expressão Gênica no Desenvolvimento , Células-Tronco Hematopoéticas/metabolismo , Células-Tronco Hematopoéticas/citologia , Metiltransferases/metabolismo , Metiltransferases/genética , Proteínas de Ligação a RNA/metabolismo , Proteínas de Ligação a RNA/genética , Peixe-Zebra/metabolismo , Peixe-Zebra/embriologia , Peixe-Zebra/genética , Proteínas de Peixe-Zebra/metabolismo , Proteínas de Peixe-Zebra/genética , Fatores de Transcrição/genética , Fatores de Transcrição/metabolismo , Metilação de RNA/genética
18.
Anal Chem ; 96(17): 6659-6665, 2024 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-38635916

RESUMO

The enhancement of sensitivity in biological analysis detection can reduce the probability of false positives of the biosensor. In this work, a novel self-on controlled-release electrochemiluminescence (CRE) biosensor was designed by multiple signal amplification and framework-enhanced stability strategies. As a result, the changes of the ECL signal were enhanced before and after the controlled-release process, achieving sensitive detection of prostate-specific antigen (PSA). Specifically, for one thing, Fe3O4@CeO2-NH2 with two paths for enhancing the generation of coreactant radicals was used as the coreaction accelerator to boost ECL performance. For another, due to the framework stability, zeolitic imidazolate framework-8-NH2 (ZIF-8-NH2) was combined with luminol to make the ECL signal more stable. Based on these strategies, the constructed CRE biosensor showed a strong self-on effect in the presence of PSA and high sensitivity in a series of tests. The detection range and limit of detection (LOD) were 5 fg/mL to 10 ng/mL and 2.8 fg/mL (S/N = 3), respectively, providing a feasible approach for clinical detection of PSA.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Medições Luminescentes , Antígeno Prostático Específico , Antígeno Prostático Específico/análise , Antígeno Prostático Específico/sangue , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Humanos , Limite de Detecção , Masculino , Cério/química , Luminol/química
19.
J Colloid Interface Sci ; 665: 934-943, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38569310

RESUMO

Polycyclic aromatic hydrocarbons (PAHs) are excellent alternative luminophores for electrochemiluminescence (ECL) immunoassays. However, they are inevitably limited by the aggregation-caused quenching effect. In this study, aimed at eliminating the aggregation quenching of PAHs, luminescent metal-organic frameworks (MOFs) with 1,3,6,8-tetra(4-carboxybenzene)pyrene (H4TBAPy) as the ligand were exploited as a novel nano-emitter for the construction of ECL immunoassays. The luminophore exhibits efficient aggregation-induced emission enhancement, good acid-base resistance property and unusual ECL reactivity. In addition, the simultaneous use of potassium persulfate and hydrogen peroxide as dual co-reactants resulted in a synergistic enhancement of the cathodic ECL efficiency. The use of magnetic iron-nickel alloys as the multifunctional sensing platform can further enhance the ECL activity, and its enriched zero-valent iron as a co-reactant accelerator effectively drives ECL analytical performance. Profiting from the excellent characteristics, signal-on ECL immunoassays have been constructed. With carcinoembryonic antigen as the model analysis target, a detection limit of 0.63 pg/mL was obtained within the linear range of 1 pg/mL to 50 ng/mL, accompanied by excellent analytical performance. This report opens a new window for the rational design of efficient ECL illuminators, and the proposed ECL immunoassays may find promising applications in the detection of disease markers.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Estruturas Metalorgânicas , Hidrocarbonetos Policíclicos Aromáticos , Pirenos , Imunoensaio , Ferro , Medições Luminescentes , Técnicas Eletroquímicas , Limite de Detecção
20.
ACS Sens ; 9(4): 1992-1999, 2024 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-38536770

RESUMO

The construction of assays is capable of accurately detecting cytokeratin-19 (CYFRA 21-1), which is critical for the rapid diagnosis of nonsmall cell lung cancer. In this work, a novel electrochemiluminescence (ECL) immunosensor based on the co-reaction promotion of luminol@Au@Ni-Co nanocages (NCs) as ECL probe by Ti3C2Tx MXene@TiO2-MoS2 hybrids as co-reaction accelerator was proposed to detect CYFRA 21-1. Ni-Co NCs, as a derivative of Prussian blue analogs, can be loaded with large quantities of Au NPs, luminol, and CYFRA 21-1 secondary antibodies due to their high specific surface area. To further improve the sensitivity of the developed ECL immunosensor, Ti3C2Tx MXene@TiO2-MoS2 hybrids were prepared by in situ growth of TiO2 nanosheets on highly conductive Ti3C2Tx MXene, and MoS2 was homogeneously grown on Ti3C2Tx MXene@TiO2 surfaces by the hydrothermal method. Ti3C2Tx MXene@TiO2-MoS2 hybrids possess excellent catalytic performance on the electro-redox of H2O2 generating more O2·- and obtaining optimal ECL intensity of the luminol/H2O2 system. Under the appropriate experimental conditions, the quantitative detection range of CYFRA 21-1 was from 0.1 pg mL-1 to 100 ng mL-1, and the limit of detection (LOD) was 0.046 pg mL-1. The present sensor has a lower LOD with a wider linear range, which provides a new analytical assay for the early diagnosis of small-cell-type lung cancer labels.


Assuntos
Antígenos de Neoplasias , Técnicas Biossensoriais , Dissulfetos , Técnicas Eletroquímicas , Ouro , Queratina-19 , Medições Luminescentes , Luminol , Molibdênio , Titânio , Queratina-19/sangue , Queratina-19/imunologia , Titânio/química , Luminol/química , Molibdênio/química , Ouro/química , Antígenos de Neoplasias/imunologia , Técnicas Eletroquímicas/métodos , Humanos , Técnicas Biossensoriais/métodos , Medições Luminescentes/métodos , Imunoensaio/métodos , Dissulfetos/química , Limite de Detecção , Níquel/química , Cobalto/química , Nanopartículas Metálicas/química , Anticorpos Imobilizados/imunologia , Anticorpos Imobilizados/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA