Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Arthroscopy ; 40(4): 1044-1055, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37716627

RESUMO

PURPOSE: To develop a machine learning model capable of identifying subscapularis tears before surgery based on imaging and physical examination findings. METHODS: Between 2010 and 2020, 202 consecutive shoulders underwent arthroscopic rotator cuff repair by a single surgeon. Patient demographics, physical examination findings (including range of motion, weakness with internal rotation, lift/push-off test, belly press test, and bear hug test), and imaging (including direct and indirect signs of tearing, biceps status, fatty atrophy, cystic changes, and other similar findings) were included for model creation. RESULTS: Sixty percent of the shoulders had partial or full thickness tears of the subscapularis verified during surgery (83% of these were upper third). Using only preoperative imaging-related parameters, the XGBoost model demonstrated excellent performance at predicting subscapularis tears (c-statistic, 0.84; accuracy, 0.85; F1 score, 0.87). The top 5 features included direct signs related to the presence of tearing as evidenced on magnetic resonance imaging (MRI) (changes in tendon morphology and signal), as well as the quality of the MRI and biceps pathology. CONCLUSIONS: In this study, machine learning was successful in predicting subscapularis tears by MRI alone in 85% of patients, and this accuracy did not decrease by isolating the model to the top features. The top five features included direct signs related to the presence of tearing as evidenced on MRI (changes in tendon morphology and signal), as well as the quality of the MRI and biceps pathology. Last, in advanced modeling, the addition of physical examination or patient characteristics did not make a significant difference in the predictive ability of this model. LEVEL OF EVIDENCE: Level III, diagnostic case-control study.


Assuntos
Lacerações , Lesões do Manguito Rotador , Humanos , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Estudos de Casos e Controles , Exame Físico/métodos , Ombro/cirurgia , Ruptura , Artroscopia/métodos , Imageamento por Ressonância Magnética
3.
Med Phys ; 49(10): 6346-6358, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35983992

RESUMO

BACKGROUND: Dual-energy CT with virtual noncalcium (VNCa) images allows the evaluation of focal intramedullary bone marrow involvement in patients with multiple myeloma. However, current commercial VNCa techniques suffer from excessive image noise and artifacts due to material decomposition used in synthesizing VNCa images. OBJECTIVES: In this work, we aim to improve VNCa image quality for the assessment of focal multiple myeloma, using an Artificial intelligence based Generalizable Algorithm for mulTi-Energy CT (AGATE) method. MATERIALS AND METHODS: AGATE method used a custom dual-task convolutional neural network (CNN) that concurrently carries out material classification and quantification. The material classification task provided an auxiliary regularization to the material quantification task. CNN parameters were optimized using custom loss functions that involved cross-entropy, physics-informed constraints, structural redundancy in spectral and material images, and texture information in spectral images. For training data, CT phantoms (diameters 30 to 45 cm) with tissue-mimicking inserts were scanned on a third generation dual-source CT system. Scans were performed at routine dose and half of the routine dose. Small image patches (i.e., 40 × 40 pixels) of tissue-mimicking inserts with known basis material densities were extracted for training samples. Numerically simulated insert materials with various shapes increased diversity of training samples. Generalizability of AGATE was evaluated using CT images from phantoms and patients. In phantoms, material decomposition accuracy was estimated using mean-absolute-percent-error (MAPE), using physical inserts that were not used during the training. Noise power spectrum (NPS) and modulation transfer function (MTF) were compared across phantom sizes and radiation dose levels. Five patients with multiple myeloma underwent dual-energy CT, with VNCa images generated using a commercial method and AGATE. Two fellowship-trained musculoskeletal radiologists reviewed the VNCa images (commercial and AGATE) side-by-side using a dual-monitor display, blinded to VNCa type, rating the image quality for focal multiple myeloma lesion visualization using a 5-level Likert comparison scale (-2 = worse visualization and diagnostic confidence, -1 = worse visualization but equivalent diagnostic confidence, 0 = equivalent visualization and diagnostic confidence, 1 = improved visualization but equivalent diagnostic confidence, 2 = improved visualization and diagnostic confidence). A post hoc assignment of comparison ratings was performed to rank AGATE images in comparison to commercial ones. RESULTS: AGATE demonstrated consistent material quantification accuracy across phantom sizes and radiation dose levels, with MAPE ranging from 0.7% to 4.4% across all testing materials. Compared to commercial VNCa images, the AGATE-synthesized VNCa images yielded considerably lower image noise (50-77% noise reduction) without compromising noise texture or spatial resolution across different phantom sizes and two radiation doses. AGATE VNCa images had markedly reduced area under NPS curves and maintained NPS peak frequency (0.7 lp/cm to 1.0 lp/cm), with similar MTF curves (50% MTF at 3.0 lp/cm). In patients, AGATE demonstrated reduced image noise and artifacts with improved delineation of focal multiple myeloma lesions (all readers comparison scores indicating improved overall diagnostic image quality [scores 1 or 2]). CONCLUSIONS: AGATE demonstrated reduced noise and artifacts in VNCa images and ability to improve visualization of bone marrow lesions for assessing multiple myeloma.


Assuntos
Aprendizado Profundo , Mieloma Múltiplo , Inteligência Artificial , Humanos , Mieloma Múltiplo/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos
4.
AJR Am J Roentgenol ; 216(4): 1022-1030, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32755207

RESUMO

BACKGROUND. CT attenuation thresholds that accurately distinguish enostoses from untreated osteoblastic metastases have been published. In the Mayo Clinic practices, these thresholds have been applied more broadly to distinguish benign sclerotic bone lesions other than enostoses from osteoblastic metastases. OBJECTIVE. The purpose of this article is to determine if CT attenuation thresholds allow the distinguishing of benign sclerotic bone lesions from osteoblastic metastases in patients undergoing bone biopsy. METHODS. A retrospective search was conducted to identify sclerotic lesions described on CT between October 7, 1998, and July 15, 2018, that underwent subsequent biopsy. Two musculoskeletal radiologists recorded lesions' maximum and mean attenuation. Using previously published attenuation thresholds, sensitivity and specificity for differentiating benign sclerotic lesions from osteoblastic metastases were calculated. ROC curve analysis was performed to determine if more appropriate attenuation thresholds exist. Intraclass correlation coefficients (ICCs) were computed. RESULTS. A total of 280 patients met inclusion criteria. Of those, 162 had malignant biopsy results and 118 had benign biopsy results. Of the 162 malignant lesions, 81 had received prior treatment. Maximum and mean attenuation were not significantly different between benign and malignant lesions for either reader (all p > .05). For reader 1, to distinguish benign from malignant lesions, a maximum attenuation threshold of more than 1060 HU resulted in sensitivity of 23.7%, specificity of 87.0%, and accuracy of 60.6%. A mean attenuation threshold of greater than 885 HU resulted in sensitivity of 19.5%, specificity of 90.7%, and accuracy 60.7%. ROC curve analysis showed AUCs for mean and maximum attenuation thresholds of 51.8% and 54.6%, respectively. Subgroup analyses of benign versus malignant and treated versus untreated lesions had similar results. Similar findings were obtained for reader 2. The two readers' ICC was 0.946 for maximum attenuation and 0.918 for mean attenuation. CONCLUSION. Published attenuation thresholds for distinguishing enostoses from osteoblastic metastases had slightly decreased specificity and markedly decreased sensitivity when applied to the differentiation of benign sclerotic lesions from osteoblastic metastases in our sample of biopsy-proven lesions. ROC analysis showed no high-performing attenuation threshold alternative. CLINICAL IMPACT. Published CT attenuation thresholds intended for distinguishing enostoses from osteoblastic metastases should not be used more broadly. More accurate alternative thresholds could not be derived.


Assuntos
Neoplasias Ósseas/patologia , Osso e Ossos/patologia , Tomografia Computadorizada por Raios X , Idoso , Biópsia , Neoplasias Ósseas/diagnóstico por imagem , Osso e Ossos/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Esclerose , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
5.
Skeletal Radiol ; 47(11): 1475-1481, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29754193

RESUMO

OBJECTIVE: The purpose of this study is to describe the MR arthrogram appearance of the postoperative glenoid labrum and to describe the features consistent with recurrent tear. MATERIALS AND METHODS: We identified 30 patients who had undergone glenoid labral repair, had a subsequent MR arthrogram of his or her shoulder, and went on to repeat shoulder arthroscopy. Each MR arthrogram was reviewed blindly, and the glenoid labrum was described as normal, irregular, or torn. Additional findings recorded included the presence or absence of a paralabral cyst and suture anchors in the glenoid. The operative report was also reviewed for each patient to determine the status of the labrum at arthroscopy. RESULTS: Following consensus review, 18/30 MRIs were felt to demonstrate recurrent glenoid labral tear, 11/30 showed an irregular labrum, and 1/30 was called normal. The radiology impression regarding the presence or absence of a recurrent glenoid labral tear agreed with the operative report in 24/30 (80%) cases, and was discrepant in six. This equals 83.3% sensitivity and 81.8% specificity of MR arthrogram in the diagnosis of recurrent labral tear in this study. A paralabral cyst was present in 3/30 (10%) cases, all three of which were torn. CONCLUSIONS: MR arthrogram findings of signal equal to gadolinium or fluid within or underlying the glenoid labrum and markedly diminutive or absent labrum were the most useful features to diagnose recurrent tear. Some signal underlying the labrum, which is confined to the anterosuperior quadrant, may be normal. The secondary finding of a paralabral cyst was also highly sensitive for recurrent tear.


Assuntos
Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Adolescente , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
6.
Skeletal Radiol ; 47(11): 1553-1558, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29632963

RESUMO

Pacinian corpuscles, the main touch receptors to pressure and vibration, are ubiquitous in the deep dermis and hypodermis of the fingers and palms. Nevertheless, their existence is largely unknown to most radiologists. We frequently noted hyperintense nodules in the palms of patients on water-sensitive MRI sequences, but were unable to explain their etiology. We recently encountered two patients who had Pacinian corpuscles identified at surgical exploration and pathological analysis. Pre-operative MRI examinations in these patients showed T2 hyperintense subcutaneous palmar nodules corresponding to these corpuscles in a pattern identical to those seen incidentally in other patients. Descriptions from the dermatopathological and orthopedic literature closely correspond to our MRI observations. Based on these data, we hypothesize that the MRI finding that we previously noted represents normal Pacinian corpuscles.


Assuntos
Mãos/diagnóstico por imagem , Achados Incidentais , Corpúsculos de Pacini/diagnóstico por imagem , Idoso , Feminino , Dedos/diagnóstico por imagem , Mãos/inervação , Humanos , Imageamento por Ressonância Magnética , Masculino , Neurofibroma/diagnóstico por imagem , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA