Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Heart Rhythm O2 ; 5(4): 234-242, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38690147

RESUMO

Background: Cardiac radioablation is a new treatment for patients with refractory ventricular tachycardia (VT). The target for cardiac radioablation is subject to cardiorespiratory motion (CRM), the heart's movement with breathing and cardiac contraction. Data regarding the magnitude of target CRM are limited but are highly important for treatment planning. Objectives: The study sought to assess CRM amplitude by using ablation catheter geometrical data. Methods: Electroanatomic mapping data of patients undergoing catheter ablation for VT at 3 academic centers were exported. The spatial position of the ablation catheter as a function of time while in contact with endocardium was analyzed and used to quantify CRM. Results: Forty-four patients with ischemic and nonischemic cardiomyopathy and VT contributed 1364 ablation lesions to the analysis. Average cardiac and respiratory excursion were 1.62 ± 1.21 mm and 12.12 ± 4.10 mm, respectively. The average ratio of respiratory to cardiac motion was approximately 11:1. CRM was greatest along the craniocaudal axis (9.66 ± 4.00 mm). Regional variations with respect to respiratory and cardiac motion were observed: basal segments had smaller displacements vs midventricular and apical segments. Patient characteristics (previous cardiac surgery, height, weight, body mass index, and left ventricular ejection fraction) had a statistically significant, albeit clinically moderate, impact on CRM. Conclusion: CRM is primarily determined by respiratory displacement and is modulated by the location of the target and the patient's biometric characteristics. The patient-specific quantification of CRM may allow to decrease treatment volume and reduce radiation exposure of surrounding organs at risk while delivering the therapeutic dose to the target.

2.
Circulation ; 146(19): 1434-1443, 2022 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-36205131

RESUMO

BACKGROUND: A novel risk calculator based on clinical characteristics and noninvasive tests that predicts the onset of clinical sustained ventricular arrhythmias (VA) in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) has been proposed and validated by recent studies. It remains unknown whether programmed ventricular stimulation (PVS) provides additional prognostic value. METHODS: All patients with a definite ARVC diagnosis, no history of sustained VAs at diagnosis, and PVS performed at baseline were extracted from 6 international ARVC registries. The calculator-predicted risk for sustained VA (sustained or implantable cardioverter defibrillator treated ventricular tachycardia [VT] or fibrillation, [aborted] sudden cardiac arrest) was assessed in all patients. Independent and combined performance of the risk calculator and PVS on sustained VA were assessed during a 5-year follow-up period. RESULTS: Two hundred eighty-eight patients (41.0±14.5 years, 55.9% male, right ventricular ejection fraction 42.5±11.1%) were enrolled. At PVS, 137 (47.6%) patients had inducible ventricular tachycardia. During a median of 5.31 [2.89-10.17] years of follow-up, 83 (60.6%) patients with a positive PVS and 37 (24.5%) with a negative PVS experienced sustained VA (P<0.001). Inducible ventricular tachycardia predicted clinical sustained VA during the 5-year follow-up and remained an independent predictor after accounting for the calculator-predicted risk (HR, 2.52 [1.58-4.02]; P<0.001). Compared with ARVC risk calculator predictions in isolation (C-statistic 0.72), addition of PVS inducibility showed improved prediction of VA events (C-statistic 0.75; log-likelihood ratio for nested models, P<0.001). PVS inducibility had a 76% [67-84] sensitivity and 68% [61-74] specificity, corresponding to log-likelihood ratios of 2.3 and 0.36 for inducible (likelihood ratio+) and noninducible (likelihood ratio-) patients, respectively. In patients with a ARVC risk calculator-predicted risk of clinical VA events <25% during 5 years (ie, low/intermediate subgroup), PVS had a 92.6% negative predictive value. CONCLUSIONS: PVS significantly improved risk stratification above and beyond the calculator-predicted risk of VA in a primary prevention cohort of patients with ARVC, mainly for patients considered to be at low and intermediate risk by the clinical risk calculator.


Assuntos
Displasia Arritmogênica Ventricular Direita , Prevenção Primária , Feminino , Humanos , Masculino , Arritmias Cardíacas/epidemiologia , Displasia Arritmogênica Ventricular Direita/epidemiologia , Displasia Arritmogênica Ventricular Direita/prevenção & controle , Morte Súbita Cardíaca/epidemiologia , Desfibriladores Implantáveis , Prevenção Primária/métodos , Medição de Risco/métodos , Fatores de Risco , Volume Sistólico , Taquicardia Ventricular/epidemiologia , Função Ventricular Direita , Adulto , Pessoa de Meia-Idade
3.
Eur Heart J ; 43(32): e1-e9, 2022 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-35441664

RESUMO

AIMS: Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVC) is characterized by ventricular arrhythmias (VAs) and sudden cardiac death (SCD). We aimed to develop a model for individualized prediction of incident VA/SCD in ARVC patients. METHODS AND RESULTS: Five hundred and twenty-eight patients with a definite diagnosis and no history of sustained VAs/SCD at baseline, aged 38.2 ± 15.5 years, 44.7% male, were enrolled from five registries in North America and Europe. Over 4.83 (interquartile range 2.44-9.33) years of follow-up, 146 (27.7%) experienced sustained VA, defined as SCD, aborted SCD, sustained ventricular tachycardia, or appropriate implantable cardioverter-defibrillator (ICD) therapy. A prediction model estimating annual VA risk was developed using Cox regression with internal validation. Eight potential predictors were pre-specified: age, sex, cardiac syncope in the prior 6 months, non-sustained ventricular tachycardia, number of premature ventricular complexes in 24 h, number of leads with T-wave inversion, and right and left ventricular ejection fractions (LVEFs). All except LVEF were retained in the final model. The model accurately distinguished patients with and without events, with an optimism-corrected C-index of 0.77 [95% confidence interval (CI) 0.73-0.81] and minimal over-optimism [calibration slope of 0.93 (95% CI 0.92-0.95)]. By decision curve analysis, the clinical benefit of the model was superior to a current consensus-based ICD placement algorithm with a 20.3% reduction of ICD placements with the same proportion of protected patients (P < 0.001). CONCLUSION: Using the largest cohort of patients with ARVC and no prior VA, a prediction model using readily available clinical parameters was devised to estimate VA risk and guide decisions regarding primary prevention ICDs (www.arvcrisk.com).


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Taquicardia Ventricular , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Feminino , Humanos , Lactente , Masculino , Fatores de Risco , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia
4.
BMC Cardiovasc Disord ; 21(1): 445, 2021 09 16.
Artigo em Inglês | MEDLINE | ID: mdl-34530738

RESUMO

BACKGROUND: Catheter ablation is an established therapy for atrial fibrillation but is limited by recurrence; efforts have been made to identify biomarkers that predict recurrence. We investigated the effect of baseline NT-proBNP on AF recurrence following catheter ablation in patients randomized to aggressive (< 120/80 mmHg) or standard blood pressure management (< 140/90 mmHg) in the Substrate Modification with Aggressive Blood Pressure Control trial (SMAC-AF). METHODS: The SMAC-AF study included 173 patients resistant or intolerant to at least one class I or III antiarrhythmic drug. We studied the effect of baseline NT-proBNP on the primary outcome of AF recurrence > 3 months post-ablation. RESULTS: Of the 173 patients, 88 were randomized to the aggressive cohort, and 85 into the standard group. The primary outcome occurred in 61.4% of those in the aggressive arm, versus 61.2% in the standard arm. In the aggressive group, logNT-proBNP predicted recurrence (HR 1.28, p = 0.04, adjusted HR 1.43, p = 0.03), while in the standard cohort, it did not (HR 0.94, p = 0.62, adjusted HR 0.83, p = 0.22). NT-proBNP ≥ 280 pg/mL also predicted occurrence in the aggressive (HR 1.98, p = 0.02) but not the standard cohort (HR 1.00, p = 1.00). CONCLUSION: We conclude that pre-ablation NT-proBNP may be useful in predicting recurrence in hypertensive patients and identifying patients who benefit from aggressive blood control and upstream therapies. TRIAL REGISTRATION: NCT00438113, registered February 21, 2007.


Assuntos
Anti-Hipertensivos/uso terapêutico , Fibrilação Atrial/cirurgia , Pressão Sanguínea/efeitos dos fármacos , Ablação por Cateter , Criocirurgia , Frequência Cardíaca , Hipertensão/tratamento farmacológico , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Potenciais de Ação , Idoso , Anti-Hipertensivos/efeitos adversos , Fibrilação Atrial/sangue , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Biomarcadores/sangue , Canadá , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Hipertensão/sangue , Hipertensão/diagnóstico , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Recidiva , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Circ Arrhythm Electrophysiol ; 14(1): e008509, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33296238

RESUMO

BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is associated with ventricular arrhythmias (VA) and sudden cardiac death (SCD). A model was recently developed to predict incident sustained VA in patients with ARVC. However, since this outcome may overestimate the risk for SCD, we aimed to specifically predict life-threatening VA (LTVA) as a closer surrogate for SCD. METHODS: We assembled a retrospective cohort of definite ARVC cases from 15 centers in North America and Europe. Association of 8 prespecified clinical predictors with LTVA (SCD, aborted SCD, sustained, or implantable cardioverter-defibrillator treated ventricular tachycardia >250 beats per minute) in follow-up was assessed by Cox regression with backward selection. Candidate variables included age, sex, prior sustained VA (≥30s, hemodynamically unstable, or implantable cardioverter-defibrillator treated ventricular tachycardia; or aborted SCD), syncope, 24-hour premature ventricular complexes count, the number of anterior and inferior leads with T-wave inversion, left and right ventricular ejection fraction. The resulting model was internally validated using bootstrapping. RESULTS: A total of 864 patients with definite ARVC (40±16 years; 53% male) were included. Over 5.75 years (interquartile range, 2.77-10.58) of follow-up, 93 (10.8%) patients experienced LTVA including 15 with SCD/aborted SCD (1.7%). Of the 8 prespecified clinical predictors, only 4 (younger age, male sex, premature ventricular complex count, and number of leads with T-wave inversion) were associated with LTVA. Notably, prior sustained VA did not predict subsequent LTVA (P=0.850). A model including only these 4 predictors had an optimism-corrected C-index of 0.74 (95% CI, 0.69-0.80) and calibration slope of 0.95 (95% CI, 0.94-0.98) indicating minimal over-optimism. CONCLUSIONS: LTVA events in patients with ARVC can be predicted by a novel simple prediction model using only 4 clinical predictors. Prior sustained VA and the extent of functional heart disease are not associated with subsequent LTVA events.


Assuntos
Displasia Arritmogênica Ventricular Direita/complicações , Morte Súbita Cardíaca/epidemiologia , Função Ventricular Direita/fisiologia , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Displasia Arritmogênica Ventricular Direita/terapia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Eletrocardiografia , Seguimentos , Saúde Global , Humanos , Incidência , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico
6.
A A Pract ; 14(14): e01346, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33295744

RESUMO

Dynamic right ventricular outflow tract obstruction is rare in the cardiac surgical population. Significant obstruction developing in the perioperative period can contribute to systemic hemodynamic instability. We describe 2 cases of dynamic right ventricular outflow tract obstruction that developed immediately after separation from cardiopulmonary bypass, due to temporary right ventricular epicardial pacing. Both patients had systemic hypotension which improved once ventricular pacing was discontinued. We discuss the recognition of right ventricular outflow tract obstruction as a contributing factor to hemodynamic instability, as well as the importance of identifying the underlying cause such as to institute appropriate management in these patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ventrículos do Coração , Ponte Cardiopulmonar , Ventrículos do Coração/diagnóstico por imagem , Humanos
7.
Can J Cardiol ; 36(12): 1965-1974, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33157186

RESUMO

BACKGROUND: Pulmonary vein (PV) stenosis is a complication of atrial fibrillation (AF) ablation. The incidence of PV stenosis after routine post-ablation imaging remains unclear and is limited to single-centre studies. Our objective was to determine the incidence and predictors of PV stenosis following circumferential radiofrequency ablation in the multicentre Adenosine Following Pulmonary Vein Isolation to Target Dormant Conduction Elimination (ADVICE) trial. METHODS: Patients with symptomatic AF underwent circumferential radiofrequency ablation in one of 13 trial centres. Computed tomographic (CTA) or magnetic resonance (MRA) angiography was performed before ablation and 90 days after ablation. Two blinded reviewers measured PV diameters and areas. PVs with stenosis were classified as severe (> 70%), moderate (50%-70%), or mild (< 50%). Predictors of PV stenosis were identified by means of multivariable logistic regression. RESULTS: A total of 197 patients (median age 59.5 years, 29.4% women) were included in this substudy. PV stenosis was identified in 41 patients (20.8%) and 47 (8.2%) of 573 ablated PVs. PV stenosis was classified as mild in 42 PVs (7.3%) and moderate in 5 PVs (0.9%). No PVs had severe stenosis. Both cross-sectional area and diameter yielded similar classifications for severity of PV stenosis. Diabetes was associated with a statistically significant increased risk of PV stenosis (OR 4.91, 95% CI 1.45-16.66). CONCLUSIONS: In the first systematic multicentre evaluation of post-ablation PV stenosis, no patient acquired severe PV stenosis. Although the results are encouraging for the safety of AF ablation, 20.8% of patients had mild or moderate PV stenosis, in which the long-term effects are unknown.


Assuntos
Fibrilação Atrial , Ablação por Cateter/efeitos adversos , Angiografia por Ressonância Magnética , Complicações Pós-Operatórias , Veias Pulmonares , Estenose de Veia Pulmonar , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Canadá/epidemiologia , Ablação por Cateter/métodos , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Feminino , Humanos , Incidência , Angiografia por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/fisiopatologia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/patologia , Veias Pulmonares/cirurgia , Fatores de Risco , Índice de Gravidade de Doença , Estenose de Veia Pulmonar/diagnóstico , Estenose de Veia Pulmonar/epidemiologia , Estenose de Veia Pulmonar/etiologia , Estenose de Veia Pulmonar/fisiopatologia
8.
Am J Med Genet A ; 182(10): 2359-2368, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32808748

RESUMO

Rare loss of function variants in DSP, which codes for the desmosomal protein desmoplakin, have been implicated in dilated and arrhythmogenic right ventricular cardiomyopathies. We present a family with arrhythmogenic cardiomyopathy associated with a novel missense variant in DSP (NM_004415.4): c.877G>A, p.(Glu293Lys). The phenotype is characterized by predominant involvement of the left ventricle with systolic dysfunction, fibrosis, and life-threatening arrhythmias. We performed a systematic review of literature collecting all cardiomyopathy cases with rare missense variants in DSP. We demonstrate that the distribution of missense variants across the protein domains in cardiomyopathy cases differs from that in gnomAD (p = .04), with a case enrichment of rare missense variants in the spectrin repeat domain (36/78 [46%] in cases vs. 449/1495 [30%] in gnomAD; p = .004). Our findings highlight the predominance of cardiac arrhythmia and left ventricular involvement in desmoplakin cardiomyopathy and pinpoint to a potential mutation hotspot in DSP thereby facilitating missense variant interpretation in the diagnostic setting.


Assuntos
Arritmias Cardíacas/genética , Displasia Arritmogênica Ventricular Direita/genética , Desmoplaquinas/genética , Predisposição Genética para Doença , Arritmias Cardíacas/patologia , Displasia Arritmogênica Ventricular Direita/patologia , Feminino , Variação Genética , Ventrículos do Coração/patologia , Humanos , Masculino , Mutação de Sentido Incorreto/genética , Fenótipo
9.
Expert Rev Cardiovasc Ther ; 17(9): 645-651, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31422711

RESUMO

Introduction: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a genetically determined disease associated with a significant risk of ventricular arrhythmias and sudden cardiac death (SCD). Implantable cardioverter-defibrillators (ICDs) are the only effective preventive measure. Over the past 30 years, much effort has been invested in determining predictors of adverse arrhythmic events in these patients. Areas covered: This review summarizes available evidence on risk stratification for ARVC, with an emphasis on recent research findings. While efforts are ongoing to define risk predictors, several recent publications have synthetized and built on this knowledge base. A recently published meta-analysis has clarified the strongest predictors of ventricular arrhythmias in ARVC, which vary depending on the population included. Three management guidelines/expert consensus documents have integrated the previously described risk predictors into proposed ICD recommendations. Furthermore, a risk prediction model has allowed the integration of multiple risk factors to provide individualized risk prediction and to inform shared-decision making regarding ICD implantation. Expert opinion: Over the past few years, knowledge of risk prediction in ARVC has been consolidated and refined. Further improvements may be made by the considering additional predictors such as exercise and by targeting more specific surrogate outcomes for SCD.


Assuntos
Arritmias Cardíacas/etiologia , Displasia Arritmogênica Ventricular Direita/complicações , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Humanos , Medição de Risco , Fatores de Risco
10.
Eur Heart J ; 40(23): 1850-1858, 2019 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-30915475

RESUMO

AIMS: Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVC) is characterized by ventricular arrhythmias (VAs) and sudden cardiac death (SCD). We aimed to develop a model for individualized prediction of incident VA/SCD in ARVC patients. METHODS AND RESULTS: Five hundred and twenty-eight patients with a definite diagnosis and no history of sustained VAs/SCD at baseline, aged 38.2 ± 15.5 years, 44.7% male, were enrolled from five registries in North America and Europe. Over 4.83 (interquartile range 2.44-9.33) years of follow-up, 146 (27.7%) experienced sustained VA, defined as SCD, aborted SCD, sustained ventricular tachycardia, or appropriate implantable cardioverter-defibrillator (ICD) therapy. A prediction model estimating annual VA risk was developed using Cox regression with internal validation. Eight potential predictors were pre-specified: age, sex, cardiac syncope in the prior 6 months, non-sustained ventricular tachycardia, number of premature ventricular complexes in 24 h, number of leads with T-wave inversion, and right and left ventricular ejection fractions (LVEFs). All except LVEF were retained in the final model. The model accurately distinguished patients with and without events, with an optimism-corrected C-index of 0.77 [95% confidence interval (CI) 0.73-0.81] and minimal over-optimism [calibration slope of 0.93 (95% CI 0.92-0.95)]. By decision curve analysis, the clinical benefit of the model was superior to a current consensus-based ICD placement algorithm with a 20.6% reduction of ICD placements with the same proportion of protected patients (P < 0.001). CONCLUSION: Using the largest cohort of patients with ARVC and no prior VA, a prediction model using readily available clinical parameters was devised to estimate VA risk and guide decisions regarding primary prevention ICDs (www.arvcrisk.com).


Assuntos
Arritmias Cardíacas , Displasia Arritmogênica Ventricular Direita , Modelos Estatísticos , Adulto , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/epidemiologia , Displasia Arritmogênica Ventricular Direita/mortalidade , Morte Súbita Cardíaca/epidemiologia , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
11.
Expert Rev Cardiovasc Ther ; 16(7): 489-500, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29912584

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is the most frequent arrhythmia worldwide. While mostly seen in elderly, it can also affect young adults (≤ 45 years of age), older adolescent, and children. Areas covered: The aim of this review is to provide an overview of the current management of AF in young patients. Specific issues arise over diagnostic workup as well as antiarrhythmic and anticoagulation therapies. The future management and diagnostic strategies are also discussed. Expert commentary: Management of AF in the young adult is largely extrapolated from adult studies and guidelines. In this population, AF could reveal a genetic pathology (e.g. Brugada, Long QT or Short QT syndromes) or be the initial presentation of a cardiomyopathy. Therefore, thorough workup in the young population to eliminate potential malignant pathology.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Terapia Trombolítica/métodos , Adolescente , Adulto , Criança , Humanos , Adulto Jovem
12.
Europace ; 20(suppl_2): ii1-ii4, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29722859

RESUMO

Aims: Achieving adequate catheter tip-tissue contact is essential for delivering robust radiofrequency (RF) ablation lesions. We measured the contact force generated by a remote magnetic-guided catheter navigation system. Methods and results: A plexiglass model with an integrated scale was fashioned to mimic transvenous and retrograde access to sites in the right atrium and right and left ventricles. An 8 Fr RF ablation catheter was steered by remote magnetic guidance at fields of 0.08 and 0.10 T, with and without a long sheath positioned at the entrance of the chamber. Ten contact force readings were taken at each setting, with the scale recalibrated prior to each measurement. Generalized estimating equations were used to compare contact force measurements while adjusting for the non-independent data structure. A total of 240 contact force measurements were taken. Without a long sheath, contact forces with magnetic fields of 0.10 T (n = 60) and 0.08 T (n = 60) were similar (6.1 ± 1.4 g vs. 6.0 ± 1.3 g, P = 0.089). Contact forces were not significantly different with simulated transvenous (n = 80) and retrograde aortic (n = 40) approaches (6.2 ± 1.4 g vs. 5.7 ± 1.2 g, P = 0.132). The contact force increased substantially with a long sheath (P < 0.001) and was significantly higher with 0.10 T (n = 60) vs. 0.08 T (n = 60) fields (20.4 ± 0.6 g vs. 18.0 ± 0.5 g, P < 0.001). Conclusion: Magnetic fields of 0.08 and 0.10 T provide stable catheter contact forces, as reflected by the small variability between measurements. The average contact force is approximately 6 g without a sheath and increases to 20 g with a long sheath positioned at the entrance of the chamber of interest.


Assuntos
Cateterismo Cardíaco/métodos , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Ventrículos do Coração/cirurgia , Magnetismo/métodos , Cirurgia Assistida por Computador/métodos , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Átrios do Coração/anatomia & histologia , Ventrículos do Coração/anatomia & histologia , Humanos , Magnetismo/instrumentação , Imãs , Modelos Anatômicos , Modelos Cardiovasculares , Pressão , Cirurgia Assistida por Computador/instrumentação , Transdutores de Pressão
13.
J Cardiovasc Electrophysiol ; 29(2): 308-315, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29064134

RESUMO

INTRODUCTION: Expert societies recently published strong recommendations to reduce the exposure of patients and staff to ionizing radiation (IR) during interventional and electrophysiology (EP) procedures. However, adherence to these guidelines remains difficult and the impact of implementing such recommendations is poorly characterized. METHODS AND RESULTS: We conducted a single-center cohort study to quantify radiation exposure over time in three EP laboratories at the Montreal Heart Institute during 5,546 consecutive procedures from 2012 to 2015 by 11 primary operators. Overall, 2,618 (47.2%) procedures were catheter-based and 2,928 (52.8%) were device interventions. Interventions to reduce radiation exposure included educational initiatives to raise awareness (i.e., limiting cine acquisition, patient position, table height), slower frame rate, lower radiation dose per pulse, collimation, and integration with 3-D mapping systems and/or MediGuide technology. An 85% reduction in IR exposure was observed from 2012 to 2015, with the mean dose-area-product (DAP) decreasing from 7.65 ± 0.05 Gy·cm2 to 1.15 ± 0.04 Gy·cm2 (P < 0.001). This was true for catheter-based procedures (mean DAP 16.99 ± 0.08 to 2.00 ± 0.06 Gy·cm2 , P < 0.001) and device interventions (mean DAP 4.18 ± 0.06 to 0.64 ± 0.05 Gy·cm2 , P < 0.001). The median effective dose of IR recorded per quarter by 282 cervical dosimeters on EP staff decreased from 0.57 (IQR 0.18, 1.03) mSv in 2012 to 0.00 (IQR 0.00, 0.19) mSv in 2015, P < 0.001. CONCLUSION: Enforcing good clinical practices with simple measures and low-dose fluoroscopy settings are highly effective in reducing IR exposure in the EP lab. These promising results should encourage other EP labs to adopt similar protective measures.


Assuntos
Cateterismo Cardíaco/métodos , Técnicas Eletrofisiológicas Cardíacas , Exposição Ocupacional/prevenção & controle , Implantação de Prótese/métodos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Humanos , Exposição Ocupacional/efeitos adversos , Saúde Ocupacional , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Fatores de Proteção , Exposição à Radiação/efeitos adversos , Proteção Radiológica , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
14.
Artigo em Inglês | MEDLINE | ID: mdl-28794082

RESUMO

BACKGROUND: Insight into type 6 long-QT syndrome (LQT6), stemming from mutations in the KCNE2-encoded voltage-gated channel ß-subunit, is limited. We sought to further characterize its clinical phenotype. METHODS AND RESULTS: Individuals with reported pathogenic KCNE2 mutations identified during arrhythmia evaluation were collected from inherited arrhythmia clinics and the Rochester long-QT syndrome (LQTS) registry. Previously reported LQT6 cases were identified through a search of the MEDLINE database. Clinical features were assessed, while reported KCNE2 mutations were evaluated for genotype-phenotype segregation and classified according to the contemporary American College of Medical Genetics guidelines. Twenty-seven probands possessed reported pathogenic KCNE2 mutations, while a MEDLINE search identified 17 additional LQT6 cases providing clinical and genetic data. Sixteen probands had normal resting QTc values and only developed QT prolongation and malignant arrhythmias after exposure to QT-prolonging stressors, 10 had other LQTS pathogenic mutations, and 10 did not have an LQTS phenotype. Although the remaining 8 subjects had an LQTS phenotype, evidence suggested that the KCNE2 variant was not the underlying culprit. The collective frequency of KCNE2 variants implicated in LQT6 in the Exome Aggregation Consortium database was 1.4%, in comparison with a 0.0005% estimated clinical prevalence for LQT6. CONCLUSIONS: On the basis of clinical phenotype, the high allelic frequencies of LQT6 mutations in the Exome Aggregation Consortium database, and absence of previous documentation of genotype-phenotype segregation, our findings suggest that many KCNE2 variants, and perhaps all, have been erroneously designated as LQTS-causative mutations. Instead, KCNE2 variants may confer proarrhythmic susceptibility when provoked by additional environmental/acquired or genetic factors, or both.


Assuntos
Síndrome do QT Longo/genética , Canais de Potássio de Abertura Dependente da Tensão da Membrana/genética , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Alelos , Criança , Pré-Escolar , Feminino , Genótipo , Humanos , Síndrome do QT Longo/classificação , Masculino , Pessoa de Meia-Idade , Mutação , Fenótipo
15.
J Cardiovasc Electrophysiol ; 28(5): 559-563, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28233925

RESUMO

INTRODUCTION: The standard 4-minute application time for transcatheter cryoablation was determined in the 1990s when the system employed less potent chlorofluorocarbon refrigerants. The current refrigerant, nitrous oxide, generates substantially colder temperatures, with a faster cooling rate. METHODS AND RESULTS: We conducted a preclinical study on 32 mongrel dogs with stratified randomization of right atrial, right ventricular, and left ventricular chambers to 2-minute versus 4-minute application times using 8-mm electrode tip cryocatheters (Freezor Max, Medtronic CryoCath LP, Montreal, Canada). Animals were sacrificed one month after the procedure. Three-dimensional morphometric analyses were conducted in a blinded fashion. A total of 193 identified ablation lesions were processed for histological analyses, 102 with 2-minute applications and 91 with 4-minute applications. Ablation lesion surface area (167.8 ± 21.6 mm2 vs. 194.3 ± 22.6 mm2 , P = 0.40), maximum depth (4.4 ± 0.2 mm vs. 4.5 ± 0.2 mm, P = 0.71), and volume (125.7 ± 69.5 mm3 vs. 141.0 ± 83.5 mm3 , P = 0.25) were similar between groups. Overall, 90.2% of ablation lesions in the right atrium were transmural, 45.6% in the right ventricle, and 2.4% in the left ventricle, with no differences between 2-minute and 4-minute application times (P = 0.55). Thrombus was detected on the endocardial surface of 0.0% and 3.3% of ablation lesions created with 2-minute and 4-minute application times, respectively (P = 0.10). CONCLUSION: Single 2-minute and 4-minute application times result in catheter ablation lesions of similar size using the modern cryoablation system with nitrous oxide as a refrigerant. While these findings suggest the potential to reduce the standard 4-minute application time, further studies are required to compare clinical efficacy.


Assuntos
Cateterismo Cardíaco/métodos , Temperatura Baixa , Criocirurgia/métodos , Átrios do Coração/cirurgia , Ventrículos do Coração/cirurgia , Óxido Nitroso/farmacologia , Animais , Cães , Átrios do Coração/patologia , Ventrículos do Coração/patologia , Modelos Animais , Fatores de Tempo
16.
Ann Thorac Surg ; 103(4): 1254-1260, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27717423

RESUMO

BACKGROUND: Sutureless self-expandable aortic bioprostheses rely on radial forces for stabilization, raising concern that these devices may increase the risk of postoperative conduction disease. The purpose of this study was to determine the incidence of conduction disorders after sutureless aortic valve replacement (AVR) with the Perceval S (Sorin Group, Saluggia, Italy) bioprosthesis. METHODS: Between June 2011 and March 2013, 108 consecutive patients underwent sutureless AVR with the Perceval S prosthesis. Six patients (6%) had a permanent pacemaker (PPM) preoperatively and were excluded from the present study. Mean electrocardiographic follow-up was 14.6 ± 6.0 months. RESULTS: Mean age was 79.2 ± 4.8 years (52% female). During the postoperative period, 34 patients (34%) had first-degree atrioventricular block, 2 (2%) had Mobitz-II atrioventricular block, and 16 (16%) had complete atrioventricular block. New-onset left bundle branch block and right bundle branch block were observed in 33 patients (33%) and 22 patients (22%), respectively. Inhospital postoperative PPM implantation was required in 23 patients (23%). Preoperative aortic valve area, age more than 85 years, and preoperative right bundle branch block were found to be independently associated with inhospital PPM implantation or new-onset postoperative conduction disorder. At follow-up, 3 more patients (3%) underwent PPM implantation. The cumulative incidences of PPM dependency and ventricular pacing more than 25% of the time were 18% ± 11% and 21% ± 10%, respectively, at 18 months. CONCLUSIONS: In the present study, the postoperative PPM implantation rate (23%) after sutureless AVR with the Perceval S prosthesis was high. Surgical strategies aimed at mitigating this risk should be further investigated.


Assuntos
Estenose da Valva Aórtica/cirurgia , Arritmias Cardíacas/epidemiologia , Bioprótese/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Procedimentos Cirúrgicos sem Sutura/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento
17.
Artigo em Inglês | MEDLINE | ID: mdl-27516462

RESUMO

BACKGROUND: Early recurrences (ERs) of atrial tachyarrhythmia are common after catheter ablation of atrial fibrillation. A 3-month blanking period is recommended by current guidelines. This study sought to investigate the significance of ER during the first 3 months post ablation in predicting late recurrences and determine whether it varies according to timing. METHODS AND RESULTS: A total of 401 patients with paroxysmal atrial fibrillation undergoing pulmonary vein isolation were followed for 12 months with transtelephonic monitoring in the ADVICE (Adenosine Following Pulmonary Vein Isolation to Target Dormant Conduction Elimination) trial. Patients with atrial tachyarrhythmia ≥30 s within the 3-month blanking period were stratified according to the timing of ER. A total of 179 patients (44.6%) experienced their last episode of ER during the first (n=53), second (n=44), or third (n=82) month of the 3-month blanking period. One-year freedom from symptomatic atrial tachyarrhythmia was 77.2% in patients without ER compared with 62.6%, 36.4%, and 7.8% in patients with ER 1, 2, and 3 months post ablation, respectively (P<0.0001). Receiver operating curve analyses revealed a strong correlation between the timing of ER and late recurrence (area under the curve 0.82, P<0.0001). Corresponding hazard ratios for ER during the first, second, and third months were 1.84, 4.45, and 9.64, respectively. CONCLUSIONS: This study validates the use of a blanking period after catheter ablation for paroxysmal atrial fibrillation but calls into question the 90-day cut-off value. In particular, >90% of patients with ER during the third month post ablation experience late recurrence by 1 year. However, pending further study, repeat ablation before 90 days cannot be routinely advocated. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01058980.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Adenosina , Antiarrítmicos , Fibrilação Atrial/fisiopatologia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
18.
J Cardiovasc Electrophysiol ; 27(11): 1337-1343, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27458078

RESUMO

INTRODUCTION: Cardiac resynchronization therapy (CRT) implant procedures are often complex and prolonged, resulting in substantial ionizing radiation (IR) exposure to the patient and operator. We assessed the impact of lower-dose fluoroscopy settings and a sensor-based electromagnetic tracking system (MediGuide™, MDG) on reducing IR exposure during CRT implantation. METHODS: A single-center 2-group cohort study was conducted on 348 consecutive patients, age 66.4 ± 11.0 years, 80.4% male, with CRT implant procedures from 2013 to 2015. Patients were arbitrarily assigned to MDG (N = 239) versus no MDG (N = 109) guidance. Lower-dose fluoroscopy settings were adopted in January 2015 (3 instead of 6 fps; 23 instead of 40 nGy/pulse; N = 101). RESULTS: Overall, MDG was associated with an 82.1% reduction in IR exposure (393 µGray·m2 vs. 2191 µGray·m2 , P < 0.001). Lower-dose fluoroscopy resulted in a 59.5% reduction in IR-exposure without MDG (1055 µGray·m2 vs. 2608 µGray·m2 , P < 0.001) and 81.8% reduction with MDG (108 µGray·m2 vs. 595 µGray·m2 , P < 0.001). Low-dose fluoroscopy combined with MDG was associated with a 95.9% lower exposure to IR when compared to standard fluoroscopy without MDG (108 µGray·m2 vs. 2608 µGray·m2 , P < 0.001). Procedures with MDG were shorter (96 minutes vs. 123 minutes, P < 0.001) and associated with a trend towards a higher success rate (94.6% vs. 89.0%, P = 0.062), with fewer coronary sinus cannulation failures (2.1% vs. 6.4%, P = 0.040). CONCLUSION: Low-dose fluoroscopy settings are highly effective (>50%) in reducing IR exposure during CRT implant procedures. When combined with MDG, >95% reduction in IR exposure is achieved. Moreover, MDG shortens procedural duration and may improve acute procedural outcomes.

19.
Lancet ; 386(9994): 672-9, 2015 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-26211828

RESUMO

BACKGROUND: Catheter ablation is increasingly used to manage atrial fibrillation, but arrhythmia recurrences are common. Adenosine might identify pulmonary veins at risk of reconnection by unmasking dormant conduction, and thereby guide additional ablation to improve arrhythmia-free survival. We assessed whether adenosine-guided pulmonary vein isolation could prevent arrhythmia recurrence in patients undergoing radiofrequency catheter ablation for paroxysmal atrial fibrillation. METHODS: We did this randomised trial at 18 hospitals in Australia, Europe, and North America. We enrolled patients aged older than 18 years who had had at least three symptomatic atrial fibrillation episodes in the past 6 months, and for whom treatment with an antiarrhythmic drug failed. After pulmonary vein isolation, intravenous adenosine was administered. If dormant conduction was present, patients were randomly assigned (1:1) to additional adenosine-guided ablation to abolish dormant conduction or to no further ablation. If no dormant conduction was revealed, randomly selected patients were included in a registry. Patients were masked to treatment allocation and outcomes were assessed by a masked adjudicating committee. Patients were followed up for 1 year. The primary outcome was time to symptomatic atrial tachyarrhythmia after a single procedure in the intention-to-treat population. The trial is registered with ClinicalTrials.gov, number NCT01058980. FINDINGS: Adenosine unmasked dormant pulmonary vein conduction in 284 (53%) of 534 patients. 102 (69·4%) of 147 patients with additional adenosine-guided ablation were free from symptomatic atrial tachyarrhythmia compared with 58 (42·3%) of 137 patients with no further ablation, corresponding to an absolute risk reduction of 27·1% (95% CI 15·9-38·2; p<0·0001) and a hazard ratio of 0·44 (95% CI 0·31-0·64; p<0·0001). Of 115 patients without dormant pulmonary vein conduction, 64 (55·7%) remained free from symptomatic atrial tachyarrhythmia (p=0·0191 vs dormant conduction with no further ablation). Occurrences of serious adverse events were similar in each group. One death (massive stroke) was deemed probably related to ablation in a patient included in the registry. INTERPRETATION: Adenosine testing to identify and target dormant pulmonary vein conduction during catheter ablation of atrial fibrillation is a safe and highly effective strategy to improve arrhythmia-free survival in patients with paroxysmal atrial fibrillation. This approach should be considered for incorporation into routine clinical practice. FUNDING: Canadian Institutes of Health Research, St Jude Medical, Biosense-Webster, and M Lachapelle (Montreal Heart Institute Foundation).


Assuntos
Adenosina , Antiarrítmicos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/efeitos dos fármacos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Modelos de Riscos Proporcionais , Veias Pulmonares/cirurgia , Prevenção Secundária , Resultado do Tratamento
20.
Expert Rev Cardiovasc Ther ; 13(6): 653-64, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25947965

RESUMO

Arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC) is an uncommon but increasingly recognized inherited cardiomyopathy that is associated with malignant ventricular arrhythmias and sudden cardiac death, particularly in young individuals. The implantable cardioverter-defibrillator (ICD) is widely regarded as the only treatment modality with evidence to support improved survival in patients with ARVC and secondary prevention indications. In contrast, there is no universally accepted risk stratification scheme to guide ICD therapy for primary prevention against sudden cardiac death. Potential benefits must be weighed against the considerable risks of complications and inappropriate shocks in this young patient population. This article tackles the challenges of risk stratification for sudden cardiac death in ARVC and critically appraises available evidence for various proposed risk factors. The authors' over-arching objective is to provide the clinician with evidence-based guidance to inform decisions regarding the selection of appropriate candidates with ARVC for ICD therapy.


Assuntos
Displasia Arritmogênica Ventricular Direita/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis/efeitos adversos , Humanos , Seleção de Pacientes , Prevenção Primária/métodos , Medição de Risco , Fatores de Risco , Prevenção Secundária/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA