Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 242: 116032, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38367520

RESUMO

INTRODUCTION: Aromatase inhibitors such as anastrozole, letrozole, exemestane and selective estrogen down-regulator (SERD) fulvestrant are used mostly to treat breast cancer estrogen receptor positive in post-menopausal women. These drugs are given either through the oral route or by intramuscular injection. They have shown great inter-individual variability with a risk of cardiometabolic disorders. Hence the importance of their therapeutic drug monitoring not only for exposure-efficacy but also exposure-toxicity. We describe here a LC-MS/MS method for the simultaneous quantification of anastrozole, letrozole, exemestane and fulvestrant in human plasma. MATERIAL AND METHODS: Plasma samples were prepared by a single-step protein precipitation. The liquid chromatography system was paired with a triple quadrupole mass spectrometer. Quantification were achieved in Multiple Reactions Monitoring mode and the electrospray ionization was in positive mode. RESULTS: The method demonstrated consistent analytical performance across various parameters, including linearity, specificity, sensitivity, matrix effect, upper and lower limits of quantification, extraction recovery, precision, accuracy, hemolysis effect, dilution integrity, and stability under different storage conditions, in accordance with established guidelines. The analysis time for each run was 4 min. Calibration curves exhibited linearity within the 1-100 ng/mL range, with correlation coefficients > 0.99 for the four analytes. Plasma concentrations from 42 patients were integrated into the selected calibration. Stability assessments indicated that the four drugs remained stable at - 20 °C for three months, 15 days under refrigeration, up to 7 days at room temperature, and after three freeze-thaw cycles. CONCLUSION: We have developed and validated this quantitative method for therapeutic drug monitoring of those four hormone therapy drugs:anastrozole, letrozole, fulvestrant and exemestane. This method can be also used for future clinical pharmacokinetics /pharmacodynamics studies.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/tratamento farmacológico , Anastrozol/uso terapêutico , Letrozol/uso terapêutico , Cromatografia Líquida/métodos , Fulvestranto/uso terapêutico , Espectrometria de Massa com Cromatografia Líquida , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes
2.
J Pharm Biomed Anal ; 197: 113968, 2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-33618135

RESUMO

Kinase inhibitors (KIs) and antiandrogen drugs (AAs) are oral anticancer drugs with narrow therapeutic index that exhibit high inter- and intra-individual variability. We describe here a UPLC-MS/MS method for the simultaneous quantification of nine KIs: cobimetinib, dasatinib, ibrutinib, imatinib, nilotinib, palbociclib, ruxolitinib, sorafenib and vemurafenib; two active metabolites of them: N-desmethyl imatinib, N-oxide sorafenib; and two AAs: abiraterone and enzalutamide; with short pre-treatment and run time in order to be easily used in clinical practice for their therapeutic drug monitoring (TDM) and facilitating pharmacokinetics and pharmacokinetics/pharmacodynamics studies. Plasma samples were prepared by a single-step protein precipitation. Analytes were separated on a Waters Acquity UPLC® T3 HSS C18 column by non-linear gradient elution; with subsequent detection by Xevo® TQD triple quadrupole tandem mass spectrometer in a positive ionization mode. Analysis time was 2.8 min per run, and all analytes eluted within 1.46-1.97 minutes. The analytical performance of the method in terms of specificity, sensitivity, linearity, precision, accuracy, matrix effect, extraction recovery, limit of quantification, dilution integrity and stability of analytes under different conditions met all criteria for a bioanalytical method for the quantification of drugs. The calibration curves were linear over the range of 1-500 ng/mL for abiraterone, dasatinib and ibrutinib; 5-500 ng/mL for cobimetinib and palbociclib; 10-5,000 ng/mL for imatinib, N-desmethyl imatinib, nilotinib, sorafenib, N-oxide sorafenib and ruxolitinib; 100-50,000 ng/mL for enzalutamide and 100-100,000 ng/mL for vemurafenib with coefficient of correlation above 0.995 for all analytes. This novel method was successfully applied to TDM in clinical practice.


Assuntos
Preparações Farmacêuticas , Espectrometria de Massas em Tandem , Antagonistas de Androgênios , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida , Monitoramento de Medicamentos , Humanos , Inibidores de Proteínas Quinases , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA