Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
J Cyst Fibros ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38969602

RESUMO

BACKGROUND: Effective detection of early lung disease in cystic fibrosis (CF) is critical to understanding early pathogenesis and evaluating early intervention strategies. We aimed to compare ability of several proposed sensitive functional tools to detect early CF lung disease as defined by CT structural disease in school aged children. METHODS: 50 CF subjects (mean±SD 11.2 ± 3.5y, range 5-18y) with early lung disease (FEV1≥70 % predicted: 95.7 ± 11.8 %) performed spirometry, Multiple breath washout (MBW, including trapped gas assessment), oscillometry, cardiopulmonary exercise testing (CPET) and simultaneous spirometer-directed low-dose CT imaging. CT data were analysed using well-evaluated fully quantitative software for bronchiectasis and air trapping (AT). RESULTS: CT bronchiectasis and AT occurred in 24 % and 58 % of patients, respectively. Of the functional tools, MBW detected the highest rates of abnormality: Scond 82 %, MBWTG RV 78 %, LCI 74 %, MBWTG IC 68 % and Sacin 51 %. CPET VO2peak detected slightly higher rates of abnormality (9 %) than spirometry-based FEV1 (2 %). For oscillometry AX (14 %) performed better than Rrs (2 %) whereas Xrs and R5-19 failed to detect any abnormality. LCI and Scond correlated with bronchiectasis (r = 0.55-0.64, p < 0.001) and AT (r = 0.73-0.74, p < 0.001). MBW-assessed trapped gas was detectable in 92 % of subjects and concordant with CT-assessed AT in 74 %. CONCLUSIONS: Significant structural and functional deficits occur in early CF lung disease, as detected by CT and MBW. For MBW, additional utility, beyond that offered by LCI, was suggested for Scond and MBW-assessed gas trapping. Our study reinforces the complementary nature of these tools and the limited utility of conventional oscillometry and CPET in this setting.

3.
Biol Sex Differ ; 14(1): 41, 2023 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-37355656

RESUMO

BACKGROUND: The development and persistence of addiction is mediated in part by drug-induced alterations in nucleus accumbens (NAc) function. AMPA-type glutamate receptors (AMPARs) provide the main source of excitatory drive to the NAc and enhancements in transmission of calcium-permeable AMPARs (CP-AMPARs) mediate increased cue-triggered drug-seeking following prolonged withdrawal. Cocaine treatment regimens that result in psychomotor sensitization enhance subsequent drug-seeking and drug-taking behaviors. Furthermore, cocaine-induced locomotor sensitization followed by 14 days of withdrawal results in an increase in glutamatergic synaptic transmission. However, very few studies have examined cocaine-induced alterations in synaptic transmission of females or potential effects of experimenter-administered cocaine on NAc CP-AMPAR-mediated transmission in either sex. METHODS: Male and female rats were given repeated systemic cocaine injections to induce psychomotor sensitization (15 mg/kg, i.p. 1 injection/day, 8 days). Controls received repeated saline (1 mL/kg, i.p). After 14-16 days of withdrawal brain slices were prepared and whole-cell patch-clamp approaches in the NAc core were used to measure spontaneous excitatory post-synaptic currents (sEPSC), paired pulse ratio, and CP-AMPAR transmission. Additional female rats from this same cohort were also given a challenge injection of cocaine at withdrawal day 14 to assess the expression of sensitization. RESULTS: Repeated cocaine produced psychomotor sensitization in both sexes. In males this was accompanied by an increase in sEPSC frequency, but not amplitude, and there was no effect on the paired pulse ratio. Males treated with cocaine and saline had similar sensitivity to Naspm. In contrast, in females there were no significant differences between cocaine and saline groups on any measure, despite females showing robust psychomotor sensitization both during the induction and expression phase. CONCLUSIONS: Overall, these data reveal striking sex differences in cocaine-induced NAc glutamate plasticity that accompany the induction of psychomotor sensitization. This suggests that the neural adaptations that contribute to sensitization vary by sex.


Females are more vulnerable to substance use disorder than males. However, preclinical studies in females are lacking, particularly in regard to the function of neural regions that mediate reward and motivation such as the nucleus accumbens (NAc). Cocaine-induced changes in excitatory transmission within the NAc play important roles in cocaine-seeking and addiction, but are under-studied in females. Here we found that cocaine treatment enhances NAc excitatory transmission in males, but has no effects on this aspect of NAc function in females. The neural processes underlying addiction may vary according to gonadal sex.


Assuntos
Cocaína , Feminino , Ratos , Masculino , Animais , Cocaína/farmacologia , Cocaína/metabolismo , Núcleo Accumbens , Ratos Sprague-Dawley , Ácido Glutâmico/metabolismo , Ácido Glutâmico/farmacologia , Transmissão Sináptica , Receptores de AMPA/metabolismo
4.
Front Pediatr ; 11: 1068103, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36816383

RESUMO

Objectives: Quantitative computed tomography (QCT) offers some promising markers to quantify cystic fibrosis (CF)-lung disease. Air trapping may precede irreversible bronchiectasis; therefore, the temporal interdependencies of functional and structural lung disease need to be further investigated. We aim to quantify airway dimensions and air trapping on chest CT of school-age children with mild CF-lung disease over two years. Methods: Fully-automatic software analyzed 144 serial spirometer-controlled chest CT scans of 36 children (median 12.1 (10.2-13.8) years) with mild CF-lung disease (median ppFEV1 98.5 (90.8-103.3) %) at baseline, 3, 12 and 24 months. The airway wall percentage (WP5-10), bronchiectasis index (BEI), as well as severe air trapping (A3) were calculated for the total lung and separately for all lobes. Mixed linear models were calculated, considering the lobar distribution of WP5-10, BEI and A3 cross-sectionally and longitudinally. Results: WP5-10 remained stable (P = 0.248), and BEI changed from 0.41 (0.28-0.7) to 0.54 (0.36-0.88) (P = 0.156) and A3 from 2.26% to 4.35% (P = 0.086) showing variability over two years. ppFEV1 was also stable (P = 0.276). A robust mixed linear model showed a cross-sectional, regional association between WP5-10 and A3 at each timepoint (P < 0.001). Further, BEI showed no cross-sectional, but another mixed model showed short-term longitudinal interdependencies with air trapping (P = 0.003). Conclusions: Robust linear/beta mixed models can still reveal interdependencies in medical data with high variability that remain hidden with simpler statistical methods. We could demonstrate cross-sectional, regional interdependencies between wall thickening and air trapping. Further, we show short-term regional interdependencies between air trapping and an increase in bronchiectasis. The data indicate that regional air trapping may precede the development of bronchiectasis. Quantitative CT may capture subtle disease progression and identify regional and temporal interdependencies of distinct manifestations of CF-lung disease.

5.
PLoS One ; 16(3): e0248902, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33760861

RESUMO

BACKGROUND: Radiologic evidence of air trapping (AT) on expiratory computed tomography (CT) scans is associated with early pulmonary dysfunction in patients with cystic fibrosis (CF). However, standard techniques for quantitative assessment of AT are highly variable, resulting in limited efficacy for monitoring disease progression. OBJECTIVE: To investigate the effectiveness of a convolutional neural network (CNN) model for quantifying and monitoring AT, and to compare it with other quantitative AT measures obtained from threshold-based techniques. MATERIALS AND METHODS: Paired volumetric whole lung inspiratory and expiratory CT scans were obtained at four time points (0, 3, 12 and 24 months) on 36 subjects with mild CF lung disease. A densely connected CNN (DN) was trained using AT segmentation maps generated from a personalized threshold-based method (PTM). Quantitative AT (QAT) values, presented as the relative volume of AT over the lungs, from the DN approach were compared to QAT values from the PTM method. Radiographic assessment, spirometric measures, and clinical scores were correlated to the DN QAT values using a linear mixed effects model. RESULTS: QAT values from the DN were found to increase from 8.65% ± 1.38% to 21.38% ± 1.82%, respectively, over a two-year period. Comparison of CNN model results to intensity-based measures demonstrated a systematic drop in the Dice coefficient over time (decreased from 0.86 ± 0.03 to 0.45 ± 0.04). The trends observed in DN QAT values were consistent with clinical scores for AT, bronchiectasis, and mucus plugging. In addition, the DN approach was found to be less susceptible to variations in expiratory deflation levels than the threshold-based approach. CONCLUSION: The CNN model effectively delineated AT on expiratory CT scans, which provides an automated and objective approach for assessing and monitoring AT in CF patients.


Assuntos
Ar , Aprendizado Profundo , Expiração/fisiologia , Tomografia Computadorizada por Raios X , Criança , Feminino , Humanos , Masculino , Redes Neurais de Computação , Análise de Regressão , Testes de Função Respiratória
6.
Pediatr Pulmonol ; 55(4): 929-938, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31962004

RESUMO

OBJECTIVE: To determine which outcome measures could detect early progression of disease in school-age children with mild cystic fibrosis (CF) lung disease over a two-year time interval utilizing chest computed tomography (CT) scores, quantitative CT air trapping (QAT), and spirometric measurements. METHODS: Thirty-six school-age children with mild CF lung disease (median [interquartile range] age 12 [3.7] years; percent predicted forced expiratory volume in 1 second (ppFEV1 ) 99 [12.5]) were evaluated by serial spirometer-controlled chest CT scans and spirometry at baseline, 3-month, 1- and 2-years. RESULTS: No significant changes were noted at 3-month for any variable except for decreased ppFEV1 . Mucus plugging score (MPS) and QATA1andA2 increased at 1- and 2-years. The bronchiectasis score (BS), and total score (TS) were increased at 2-year. All variables tested with the exception of bronchial wall thickness score, parenchymal score (PS), and ppFEV1 , were consistent with longitudinal worsening of lung disease. Multivariate analysis revealed baseline PS, baseline TS, and 1-year changes in BS and air trapping score were predictive of 2-year changes in BS. CONCLUSIONS: MPS and QATA1-A2 were the most sensitive indicators of progressive childhood CF lung disease. The 1-year change in the bronchiectasis score had the most positive predictive power for 2-year change in bronchiectasis.


Assuntos
Bronquiectasia/etiologia , Fibrose Cística/fisiopatologia , Progressão da Doença , Adolescente , Brônquios/anatomia & histologia , Brônquios/diagnóstico por imagem , Criança , Fibrose Cística/complicações , Fibrose Cística/diagnóstico , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Muco , Análise Multivariada , Avaliação de Resultados em Cuidados de Saúde , Radiografia Torácica , Sensibilidade e Especificidade , Espirometria , Tomografia Computadorizada por Raios X
7.
Am J Respir Crit Care Med ; 200(10): 1219-1227, 2019 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-31322415

RESUMO

Childhood interstitial lung disease (chILD) comprises a spectrum of rare diffuse lung disorders. chILD is heterogeneous in origin, with different disease manifestations occurring in the context of ongoing lung development. The large number of disorders in chILD, in combination with the rarity of each diagnosis, has hampered scientific and clinical progress within the field. Epidemiologic and natural history data are limited. The prognosis varies depending on the etiology, with some forms progressing to lung transplant or death. There are limited treatment options for patients with chILD. Although U.S. Food and Drug Administration-approved treatments are now available for adult patients with idiopathic pulmonary fibrosis, no clinical trials have been conducted in a pediatric population using agents designed to treat lung fibrosis. This review will focus on progressive chILD disorders and on the urgent need for meaningful objective outcome measures to define, detect, and monitor fibrosis in children.


Assuntos
Fibrose Pulmonar Idiopática/diagnóstico , Fibrose Pulmonar Idiopática/terapia , Doenças Pulmonares Intersticiais/diagnóstico , Doenças Pulmonares Intersticiais/terapia , Criança , Pré-Escolar , Ensaios Clínicos como Assunto , Humanos , Projetos de Pesquisa
9.
Acad Radiol ; 26(9): 1202-1214, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30545681

RESUMO

RATIONALE AND OBJECTIVES: The aim of this study was to assess variability in quantitative air trapping (QAT) measurements derived from spatially aligned expiration CT scans. MATERIALS AND METHODS: Sixty-four paired CT examinations, from 16 school-age cystic fibrosis subjects examined at four separate time intervals, were used in this study. For each pair, visually inspected lobe segmentation maps were generated and expiration CT data were registered to the inspiration CT frame. Measurements of QAT, the percentage of voxels on the expiration CT scan below a set threshold were calculated for each lobe and whole-lung from the registered expiration CT and compared to the true values from the unregistered data. RESULTS: A mathematical model, which simulates the effect of variable regions of lung deformation on QAT values calculated from aligned to those from unaligned data, showed the potential for large bias. Assessment of experimental QAT measurements using Bland-Altman plots corroborated the model simulations, demonstrating biases greater than 5% when QAT was approximately 40% of lung volume. These biases were removed when calculating QAT from aligned expiration CT data using the determinant of the Jacobian matrix. We found, by Dice coefficient analysis, good agreement between aligned expiration and inspiration segmentation maps for the whole-lung and all but one lobe (Dice coefficient > 0.9), with only the lingula generating a value below 0.9 (mean and standard deviation of 0.85 ± 0.06). CONCLUSION: The subtle and predictable variability in corrected QAT observed in this study suggests that image registration is reliable in preserving the accuracy of the quantitative metrics.


Assuntos
Fibrose Cística/diagnóstico por imagem , Expiração , Inalação , Tomografia Computadorizada por Raios X , Adolescente , Algoritmos , Criança , Feminino , Humanos , Masculino , Interpretação de Imagem Radiográfica Assistida por Computador , Volume de Ventilação Pulmonar
10.
PLoS One ; 13(4): e0194557, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29630630

RESUMO

OBJECTIVES: Densitometry on paired inspiratory and expiratory multidetector computed tomography (MDCT) for the quantification of air trapping is an important approach to assess functional changes in airways diseases such as cystic fibrosis (CF). For a regional analysis of functional deficits, an accurate lobe segmentation algorithm applicable to inspiratory and expiratory scans is beneficial. MATERIALS AND METHODS: We developed a fully automated lobe segmentation algorithm, and subsequently validated automatically generated lobe masks (ALM) against manually corrected lobe masks (MLM). Paired inspiratory and expiratory CTs from 16 children with CF (mean age 11.1±2.4) acquired at 4 time-points (baseline, 3mon, 12mon, 24mon) with 2 kernels (B30f, B60f) were segmented, resulting in 256 ALM. After manual correction spatial overlap (Dice index) and mean differences in lung volume and air trapping were calculated for ALM vs. MLM. RESULTS: The mean overlap calculated with Dice index between ALM and MLM was 0.98±0.02 on inspiratory, and 0.86±0.07 on expiratory CT. If 6 lobes were segmented (lingula treated as separate lobe), the mean overlap was 0.97±0.02 on inspiratory, and 0.83±0.08 on expiratory CT. The mean differences in lobar volumes calculated in accordance with the approach of Bland and Altman were generally low, ranging on inspiratory CT from 5.7±52.23cm3 for the right upper lobe to 17.41±14.92cm3 for the right lower lobe. Higher differences were noted on expiratory CT. The mean differences for air trapping were even lower, ranging from 0±0.01 for the right upper lobe to 0.03±0.03 for the left lower lobe. CONCLUSIONS: Automatic lobe segmentation delivers excellent results for inspiratory and good results for expiratory CT. It may become an important component for lobe-based quantification of functional deficits in cystic fibrosis lung disease, reducing necessity for user-interaction in CT post-processing.


Assuntos
Fibrose Cística/fisiopatologia , Expiração , Inalação , Pulmão/fisiopatologia , Tórax/fisiopatologia , Tomografia Computadorizada por Raios X/métodos , Adolescente , Algoritmos , Automação , Criança , Fibrose Cística/diagnóstico por imagem , Feminino , Humanos , Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar , Masculino , Estudos Prospectivos , Tórax/diagnóstico por imagem
11.
Med Phys ; 42(10): 5919-27, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26429266

RESUMO

PURPOSE: Wall thickness (WT) is an airway feature of great interest for the assessment of morphological changes in the lung parenchyma. Multidetector computed tomography (MDCT) has recently been used to evaluate airway WT, but the potential risk of radiation-induced carcinogenesis-particularly in younger patients-might limit a wider use of this imaging method in clinical practice. The recent commercial implementation of the statistical model-based iterative reconstruction (MBIR) algorithm, instead of the conventional filtered back projection (FBP) algorithm, has enabled considerable radiation dose reduction in many other clinical applications of MDCT. The purpose of this work was to study the impact of radiation dose and MBIR in the MDCT assessment of airway WT. METHODS: An airway phantom was scanned using a clinical MDCT system (Discovery CT750 HD, GE Healthcare) at 4 kV levels and 5 mAs levels. Both FBP and a commercial implementation of MBIR (Veo(TM), GE Healthcare) were used to reconstruct CT images of the airways. For each kV-mAs combination and each reconstruction algorithm, the contrast-to-noise ratio (CNR) of the airways was measured, and the WT of each airway was measured and compared with the nominal value; the relative bias and the angular standard deviation in the measured WT were calculated. For each airway and reconstruction algorithm, the overall performance of WT quantification across all of the 20 kV-mAs combinations was quantified by the sum of squares (SSQs) of the difference between the measured and nominal WT values. Finally, the particular kV-mAs combination and reconstruction algorithm that minimized radiation dose while still achieving a reference WT quantification accuracy level was chosen as the optimal acquisition and reconstruction settings. RESULTS: The wall thicknesses of seven airways of different sizes were analyzed in the study. Compared with FBP, MBIR improved the CNR of the airways, particularly at low radiation dose levels. For FBP, the relative bias and the angular standard deviation of the measured WT increased steeply with decreasing radiation dose. Except for the smallest airway, MBIR enabled significant reduction in both the relative bias and angular standard deviation of the WT, particularly at low radiation dose levels; the SSQ was reduced by 50%-96% by using MBIR. The optimal reconstruction algorithm was found to be MBIR for the seven airways being assessed, and the combined use of MBIR and optimal kV-mAs selection resulted in a radiation dose reduction of 37%-83% compared with a reference scan protocol with a dose level of 1 mGy. CONCLUSIONS: The quantification accuracy of airway WT is strongly influenced by radiation dose and reconstruction algorithm. The MBIR algorithm potentially allows the desired WT quantification accuracy to be achieved with reduced radiation dose, which may enable a wider clinical use of MDCT for the assessment of airway WT, particularly for younger patients who may be more sensitive to exposures with ionizing radiation.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada Multidetectores/instrumentação , Imagens de Fantasmas , Doses de Radiação , Sistema Respiratório/diagnóstico por imagem , Adolescente , Criança , Humanos , Razão Sinal-Ruído
12.
Psychopharmacology (Berl) ; 232(17): 3149-60, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25980485

RESUMO

RATIONALE: Individuals vary in the extent to which they attribute incentive salience to reward cues. Discrete food and drug (cocaine and opioid) cues become more attractive, eliciting approach toward them, and more "wanted," in that they serve as more effective conditioned reinforcers, in some rats (sign-trackers, STs), than in others (goal-trackers, GTs). OBJECTIVES: We asked whether there is similar variation in the extent to which a cue associated with a drug from another class, nicotine, acquires incentive motivational properties. METHODS: First, a Pavlovian conditioned approach procedure was used to identify rats that attribute incentive salience to a food cue (i.e., STs and GTs). We then measured the extent to which a cue (a light) paired with intravenous nicotine injections acquired two properties of an incentive stimulus: (1) the ability to elicit approach toward it, and (2) the ability to act as a conditioned reinforcer. RESULTS: In contrast to previous findings with food, cocaine, and opioid cues, we found that the nicotine cue was equally attractive in STs and GTs, eliciting dose-dependent approach behavior in both. However, the nicotine cue was a more effective conditioned reinforcer in STs than in GTs. CONCLUSIONS: We suggest the dissociation between these two measures of incentive salience attribution may be related to the fact that when present (as in the test of Pavlovian approach), nicotine can act as a potent "incentive amplifier," and by this action, nicotine may render cues especially salient for all animals.


Assuntos
Sinais (Psicologia) , Motivação/efeitos dos fármacos , Nicotina/farmacologia , Agonistas Nicotínicos/farmacologia , Animais , Condicionamento Operante , Relação Dose-Resposta a Droga , Alimentos , Objetivos , Individualidade , Masculino , Ratos , Ratos Sprague-Dawley , Gravação em Vídeo
13.
J Cyst Fibros ; 12(6): 559-66, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23810566

RESUMO

BACKGROUND: The quality of chest Computed Tomography (CT) images in children is dependent upon a sufficient breath hold during CT scanning. This study evaluates the influence of spirometric breath hold monitoring with biofeedback software on inspiratory and expiratory chest CT lung density measures, and on trapped air (TA) scoring in children with cystic fibrosis (CF). This is important because TA is an important component of early and progressive CF lung disease. METHODS: A cross sectional comparison study was completed for chest CT imaging in two cohorts of CF children with comparable disease severity, using spirometric breath hold monitoring and biofeedback software (Copenhagen (COP)) or unmonitored breath hold manoeuvres (Gothenburg (GOT)). Inspiratory-expiratory lung density differences were calculated, and TA was scored to assess the difference between the two cohorts. RESULTS: Eighty-four chest CTs were evaluated. Mean (95%CI) change in inspiratory-expiratory lung density differences was 436 Hounsfield Units (HU) (408 to 464) in the COP cohort with spirometric breath hold monitoring versus 229 HU (188 to 269) in the GOT cohort with unmonitored breath hold manoeuvres (p<0.0001). The Mean TA (95%CI) score was 6.93 (6.05 to 7.82) in COP patients and 3.81 (2.89 to 4.73) in GOT (p<0.0001) patients. CONCLUSIONS: In children with comparable CF lung disease, spirometric breath hold monitoring during examination yielded a large difference in lung volume between inhalation and exhalation, and allowed for a significantly greater measured change in lung density and TA score, compared to unmonitored breath hold maneuvers. This has implications to the clinical use of chest CT, especially in children with early CF lung disease.


Assuntos
Fibrose Cística/diagnóstico por imagem , Medidas de Volume Pulmonar/métodos , Pulmão/diagnóstico por imagem , Espirometria/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Biorretroalimentação Psicológica , Criança , Fibrose Cística/fisiopatologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Monitorização Fisiológica , Capacidade Vital
14.
J Neurosci ; 33(19): 8321-35, 2013 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-23658172

RESUMO

Some rats [sign-trackers (STs)] are especially prone to attribute incentive salience to reward cues, relative to others [goal-trackers (GTs)]. Thus, reward cues are more likely to promote maladaptive reward-seeking behavior in STs than GTs. Here, we asked whether STs and GTs differ on another trait that can contribute to poor restraint over behavior evoked by reward cues. We report that, relative to GTs, STs have poor control over attentional performance, due in part to insufficient cholinergic stimulation of cortical circuitry. We found that, relative to GTs, STs showed poor performance on a sustained attention task (SAT). Furthermore, their performance fluctuated rapidly between periods of good to near-chance performance. This finding was reproduced using a separate cohort of rats. As demonstrated earlier, performance on the SAT was associated with increases in extracellular levels of cortical acetylcholine (ACh); however, SAT performance-associated increases in ACh levels were significantly attenuated in STs relative to GTs. Consistent with the view that the modulatory effects of ACh involve stimulation of α4ß2* nicotinic ACh receptors (nAChRs), systemic administration of the partial nAChR agonist ABT-089 improved SAT performance in STs and abolished the difference between SAT-associated ACh levels in STs and GTs. Neither the nonselective nAChR agonist nicotine nor the psychostimulant amphetamine improved SAT performance. These findings suggest that individuals who have a propensity to attribute high-incentive salience to reward cues also exhibit relatively poor attentional control. A combination of these traits may render individuals especially vulnerable to disorders, such as obesity and addiction.


Assuntos
Acetilcolina/metabolismo , Atenção/fisiologia , Sinais (Psicologia) , Motivação/fisiologia , Recompensa , Anfetamina/farmacologia , Animais , Agonistas Colinérgicos/farmacologia , Condicionamento Clássico/efeitos dos fármacos , Condicionamento Clássico/fisiologia , Inibidores da Captação de Dopamina/farmacologia , Feminino , Masculino , Microdiálise , Nicotina/farmacologia , Análise de Componente Principal , Piridinas/farmacologia , Pirrolidinas/farmacologia , Ratos , Ratos Sprague-Dawley , Fatores de Tempo , Gravação em Vídeo
15.
PLoS One ; 7(4): e34227, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22514626

RESUMO

BACKGROUND: The repeated administration of psychostimulant drugs produces a persistent and long-lasting increase ("sensitization") in their psychomotor effects, which is thought to be due to changes in the neural circuitry that mediate these behaviors. One index of neuronal activation used to identify brain regions altered by repeated exposure to drugs involves their ability to induce immediate early genes, such as c-fos. Numerous reports have demonstrated that past drug experience alters the ability of drugs to induce c-fos in the striatum, but very few have examined Fos protein expression in the two major compartments in the striatum--the so-called patch/striosome and matrix. METHODOLOGY/PRINCIPAL FINDINGS: In the present study, we used immunohistochemistry to investigate the effects of pretreatment with methamphetamine on the ability of a subsequent methamphetamine challenge to induce Fos protein expression in the patch and matrix compartments of the dorsolateral and dorsomedial caudate-putamen and in the ventral striatum (nucleus accumbens). Animals pretreated with methamphetamine developed robust psychomotor sensitization. A methamphetamine challenge increased the number of Fos-positive cells in all areas of the dorsal and ventral striatum. However, methamphetamine challenge induced Fos expression in more cells in the patch than in the matrix compartment in the dorsolateral and dorsomedial caudate-putamen. Furthermore, past experience with methamphetamine increased the number of methamphetamine-induced Fos positive cells in the patch compartment of the dorsal caudate putamen, but not in the matrix or in the core or shell of the nucleus accumbens. CONCLUSIONS/SIGNIFICANCE: These data suggest that drug-induced alterations in the patch compartment of the dorsal caudate-putamen may preferentially contribute to some of the enduring changes in brain activity and behavior produced by repeated treatment with methamphetamine.


Assuntos
Metanfetamina/farmacologia , Núcleo Accumbens/efeitos dos fármacos , Núcleo Accumbens/metabolismo , Proteínas Proto-Oncogênicas c-fos/metabolismo , Animais , Feminino , Metanfetamina/administração & dosagem , Ratos , Ratos Sprague-Dawley
16.
J Digit Imaging ; 23(6): 744-54, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19756866

RESUMO

To address potential concern for cumulative radiation exposure with serial spiral chest computed tomography (CT) scans in children with chronic lung disease, we developed an approach to match bronchial airways on low-dose spiral and low-dose high-resolution CT (HRCT) chest images to allow serial comparisons. An automated algorithm matches the position and orientation of bronchial airways obtained from HRCT slices with those in the spiral CT scan. To validate this algorithm, we compared manual matching vs automatic matching of bronchial airways in three pediatric patients. The mean absolute percentage difference between the manually matched spiral CT airway and the index HRCT airways were 9.4 ± 8.5% for the internal diameter measurements, 6.0 ± 4.1% for the outer diameter measurements, and 10.1 ± 9.3% for the wall thickness measurements. The mean absolute percentage difference between the automatically matched spiral CT airway measurements and index HRCT airway measurements were 9.2 ± 8.6% for the inner diameter, 5.8 ± 4.5% for the outer diameter, and 9.9 ± 9.5% for the wall thickness. The overall difference between manual and automated methods was 2.1 ± 1.2%, which was significantly less than the interuser variability of 5.1 ± 4.6% (p<0.05). Tests of equivalence had p<0.05, demonstrating no significant difference between the two methods. The time required for matching was significantly reduced in the automated method (p<0.01) and was as accurate as manual matching, allowing efficient comparison of airways obtained on low-dose spiral CT imaging with low-dose HRCT scans.


Assuntos
Algoritmos , Fibrose Cística/diagnóstico por imagem , Pneumopatias/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Criança , Fibrose Cística/patologia , Humanos , Doses de Radiação
17.
Pediatr Pulmonol ; 44(11): 1107-17, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19824046

RESUMO

BACKGROUND: In order to establish a valid surrogate outcome measure, it must be shown that the outcome measure (chest HRCT scores in cystic fibrosis [CF] patients) demonstrates strong statistical association with established endpoints of disease, such as Pseudomonas aeruginosa (Pa) airway acquisition, acute exacerbations, or mortality. METHODS: We estimated and tested the association between Pa infection status (Pa+ vs. Pa-) and baseline chest HRCT scores in 25 children with mild-to-moderate CF lung disease. For comparison, we estimated the association between Pa status and pulmonary function tests (PFTs), chest X-rays (CXR) scores, and BMI. Pa acquisition was determined from respiratory culture results and systematic review of clinic notes. RESULTS: All subjects had respiratory cultures performed prior to or at baseline with a median of 19 months of retrospective culture observation (SD = 15.7 months, range: 0-52.5 months). The difference between age-adjusted mean total HRCT score for Pa+ versus Pa- was highly significant (P < 0.00001) with a near-perfect separation between scores in Pa+ versus Pa- patients. Similar results were found for several HRCT sub-scores. Among PFTs, only residual volume-to-total lung capacity (RV/TLC) had a significant difference between group means (P = 0.03), but the overlap between groups in RV/TLC measurements was large. CONCLUSIONS: CF HRCT scores correlate highly with Pa acquisition, a clinically meaningful measure of progressing CF lung disease. HRCT scores are highly sensitive at predicting Pa acquisition status, while most PFT measures, chest radiograph (CXR) scores, and body mass index are not. These results provide further evidence that HRCT is appropriate for use in patient care and as an outcome measure in clinical trials.


Assuntos
Fibrose Cística/diagnóstico por imagem , Fibrose Cística/microbiologia , Infecções por Pseudomonas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adolescente , Índice de Massa Corporal , Criança , Estudos Transversais , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Curva ROC
18.
Acad Radiol ; 16(9): 1134-41, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19467609

RESUMO

RATIONALE AND OBJECTIVES: The purpose of this study was to demonstrate the use of a phantom to standardize low-dose chest computed tomographic (CT) protocols in children with cystic fibrosis. MATERIALS AND METHODS: Spiral chest CT scans of a Plexiglas phantom simulating airway sizes (internal diameter, 1.1-16.4 mm; wall thickness, 0.4-4.6 mm) in children with cystic fibrosis were obtained using two multidetector CT (MDCT) scanners (GE VCT and Siemens Sensation 64). Quantitative airway measurements from both scanners were compared with micro-CT airway measurements over a range of doses (0.2-1.8 mSv) to evaluate bias and variance of measurements. The effective doses for CT protocols were estimated using the ImPACT CT Patient Dosimetry Calculator. RESULTS: Both MDCT scanners were able to accurately measure airway sizes down to 3 mm internal diameter and 1.3 mm airway wall thickness, with errors of <3.5%. ImPACT estimates of effective dose were different for the MDCT scanners for a given peak tube voltage and product of tube current and exposure time. Accuracy and precision were not found to be associated with dose parameters for either machine. Bias in all measurements was strongly associated with airway diameter (P values < .00001), but the magnitude of bias was small (mean, 0.07 mm; maximum, 0.21 mm). Differences between machines in error components were on the order of a few micrometers. CONCLUSIONS: The use of a standard airway phantom confirms that different MDCT scanners have similar results within dose ranges planned for potential future clinical trials. Standardized protocols can be developed that adjust for differences in radiation exposure for different MDCT scanners.


Assuntos
Pulmão/diagnóstico por imagem , Estudos Multicêntricos como Assunto/normas , Imagens de Fantasmas/normas , Radiografia Torácica/instrumentação , Radiografia Torácica/normas , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/normas , Desenho de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos
19.
Chest ; 135(3): 842-848, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19265094

RESUMO

BACKGROUND: Autoimmune pulmonary alveolar proteinosis (APAP) is characterized by autoantibodies against granulocyte-macrophage colony-stimulating factor (GM-CSF) in blood and tissues, resulting in alveolar surfactant protein accumulation. Patients with APAP present with ground-glass opacities (GGOs) and interlobular septal thickening on thin-slice chest CT scans. Aerosolized GM-CSF therapy (aeroGM-SCF) has qualitatively improved the clinical condition of patients with APAP. This report details quantitative chest CT responses to aeroGM-CSF. METHODS: Two adolescent patients (aged 16 and 19 years) with APAP were treated with aeroGM-CSF. Clinical parameters, including pulmonary function tests and chest CT scans, were obtained before and after aeroGM-CSF therapy. To evaluate the effect of the therapy, serial chest CT scans were analyzed using a novel approach permitting quantitative assessment of improvement in GGOs, lung weight, and gas volume. RESULTS: In association with GM-CSF treatment, nutritional status and pulmonary function improved. Quantitative analysis of the CT scans demonstrated reduction in GGOs and lung weight, concomitant with an increase in airspace volume and lung inflation. The findings were consistent with a qualitative reduction in GGOs on chest CT imaging. CONCLUSIONS: Quantitative analysis of CT holds promise as a sensitive diagnostic tool permitting longitudinal and objective analysis of the therapeutic response to aeroGM-CSF in patients with APAP.


Assuntos
Doenças Autoimunes/tratamento farmacológico , Fator Estimulador de Colônias de Granulócitos e Macrófagos/administração & dosagem , Proteinose Alveolar Pulmonar/tratamento farmacológico , Administração por Inalação , Adolescente , Aerossóis , Doenças Autoimunes/diagnóstico por imagem , Feminino , Humanos , Pulmão/diagnóstico por imagem , Proteinose Alveolar Pulmonar/diagnóstico por imagem , Tomografia Computadorizada Espiral , Adulto Jovem
20.
Pediatr Radiol ; 39(3): 221-5, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19096836

RESUMO

BACKGROUND: Concerns have been expressed recently about the radiation burden on patient populations, especially children, undergoing serial radiological testing. To reduce the dose one can change the CT acquisition settings or decrease the sampling density. OBJECTIVE: In this study we determined the minimum desirable sampling density to ascertain the degree of air trapping in children with cystic fibrosis. MATERIALS AND METHODS: Ten children with cystic fibrosis in stable condition underwent a volumetric spiral CT scan. The degree of air trapping was determined by an automated algorithm for all slices in the volume, and then for 1/2, 1/4, to 1/128 of all slices, or a sampling density ranging from 100% to 1% of the total volume. The variation around the true value derived from 100% sampling was determined for all other sampling densities. RESULTS: The precision of the measurement remained stable down to a 10% sampling density, but decreased markedly below 3.4%. CONCLUSION: For a disease marker with the regional variability of air trapping in cystic fibrosis, regardless of observer variability, a sampling density below 10% and even more so, below 3.4%, apparently decreases the precision of the evaluation.


Assuntos
Fibrose Cística/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adolescente , Criança , Fibrose Cística/fisiopatologia , Feminino , Volume Expiratório Forçado , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Fluxo Máximo Médio Expiratório , Espirometria , Capacidade Vital
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA