Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
J Card Surg ; 36(3): 872-878, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33442932

RESUMO

AIMS: Transaortic (TAo) and transapical (TA) implantation can be used in transcatheter aortic valve implantation (TAVI) when the transfemoral (TF) approach is precluded. We compare the safety and efficacy of these alternative techniques. METHODS: From October 2007 to February 2016, TAo and TA patients' data were collected. Propensity score inverse probability of treatment weight (IPTW) method was employed to minimize the impact of no-randomization bias. RESULTS: From our single-center non-TF-TAVI registry, 282 patients were included: 235 (83.3%) underwent TAo and 47 (16.7%) TA. Differences in baseline characteristics were statistically significant in age, sex, risk profile according to logistic-EuroSCORE, and previous cardiac surgery. No difference in hospital morbidity and mortality, but lower stroke-rate in TAo (1.27% vs. 8.5% p < .01) was observed. This was confirmed at logistic regression after IPTW adjustment (odds ratio [OR]: 0.16, 95% CI 0.03-0.71, p = .01), together with reduced risk of the paravalvular leak (PVL) (OR: 0.14, 95% confidence interval [CI]: 0.02-0.81, p = .02). Kaplan-Meier estimates did not demonstrate differences in long-term mortality among access routes (logrank test p = .13). At the IPTW-Cox regression model, long-term mortality was related to New York Heart Association III-IV (hazard ratio [HR]: 2.92, 95% CI: 1.15-7.40, p = .026), chronic renal failure (HR: 3.25; 95% CI: 1.02-10.32 p = .046), previous transient ischemic attack/stroke (HR: 2.29, 95% CI: 1.25-4.20 p = .007). Sapien-3 device resulted to be a protective factor, reducing long-term mortality (HR: 0.18, 95% CI 0.04- 0.90 p = .03). CONCLUSIONS: TAo is safe and feasible in case of contraindication to femoral approach demonstrating comparable midterm outcomes to TA, thus representing a central access alternative, to increase the overall safety of high-risk TAVI procedures.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Humanos , New York , Pontuação de Propensão , Fatores de Risco , Resultado do Tratamento
2.
Interact Cardiovasc Thorac Surg ; 30(3): 400-407, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31778163

RESUMO

OBJECTIVES: Transcatheter aortic valve implantation with a transaortic approach (TAo-TAVI) is an alternative to transapical or femoral access. We studied the procedural and midterm efficacy and safety of TAo-TAVI with Edwards Sapien XT and Medtronic CoreValve devices. METHODS: Among 901 patients receiving TAVI since 2006, 265 consecutive patients underwent TAo-TAVI between January 2011 and September 2014. Procedural and midterm results were evaluated according to Valve Academic Research Consortium-2 criteria. RESULTS: The mean age was 83 ± 5 years. Sapien XT and CoreValve were used in 191 (72.1%) and 74 (27.9%) patients, respectively. Full sternotomy made elective concomitant off-pump coronary artery bypass grafting possible in 38 patients (14.3%) with severe coronary artery disease unsuitable for percutaneous coronary intervention. The device success rate was 95.5%. Postprocedural paravalvular leak ≥2/4 was observed in 16 patients (6.4%). Emergency open chest surgery was required in 10 patients (3.8%) (3 aortic dissections, 3 valve embolizations, 2 LMCA occlusions, 1 aortic annulus rupture and 1 aortic rupture). Cerebrovascular accidents occurred in 3 patients (1.1%). Transfusions ≥4 units were required in 36 patients (13.6%). New pacemakers were implanted in 26 patients (9.8%). Thirty-day and 1-year mortality were 8.7% and 16.2%, respectively. Mean follow-up duration was 24 ± 6 months. At 3 years, freedom from all-cause death was 80% ± 4%. New York Heart Association class

Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estudos de Coortes , Ponte de Artéria Coronária sem Circulação Extracorpórea , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Ecocardiografia , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Esternotomia , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
3.
Eur J Cardiothorac Surg ; 55(4): 737-743, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30346515

RESUMO

OBJECTIVES: There is lack of data regarding the longer-term outcomes of patients undergoing transaortic (TAo) transcatheter aortic valve implantation (TAVI). We aimed to provide a contemporary snapshot of the types and frequencies of events in the year following TAo-TAVI. METHODS: The Registry of the Utilization of the TAo-TAVI approach using the Edwards SAPIEN Valve (ROUTE) is a multicentre, European, prospective, observational registry of aortic stenosis patients undergoing TAo-TAVI. Patients were grouped according to the composite end point death, myocardial infarction, stroke/transient ischaemic attack, major vascular complications, life-threatening bleeding, acute kidney injury (AKI) and/or cardiovascular rehospitalization. RESULTS: Two hundred and fifty-three patients with a mean age of 81.5 ± 5.8 years were included, of whom 89 (35.2%) patients met the composite end point (the event group) and 164 (64.8%) patients did not (the event-free group). New York Heart Association (NYHA) class III/IV (85.2% vs 71.8%, P = 0.017), Canadian Cardiovascular Society angina class III/IV (22.6% vs 11.4%; P = 0.021), pulmonary disease (32.6% vs 18.9%; P = 0.015) and renal insufficiency (15.7% vs 3.0%; P < 0.001) were more common in the event group. At 1 year, the most common event was death (19.1%), followed by AKI stage II or III (14.7%). The baseline renal insufficiency was the strongest independent predictor of composite end point achievement [odds ratio (OR) 7.55, 95% confidence interval (CI) 2.33-24.56], followed by NYHA class III/IV (OR 2.316, 95% CI 1.06-5.06) and pulmonary disease (OR 2.91, 95% CI 1.45-5.85). Pulmonary disease was also an independent predictor of 1-year mortality (OR 3.01, 95% CI 1.34-6.75). CONCLUSIONS: Long-term outcomes after TAo-TAVI appear to be similar to those for TAVI via other non-transfemoral access routes. Awareness of characteristics associated with poorer outcomes may aid patient selection and identification of those requiring closer post-procedural monitoring. CLINICAL TRIAL REGISTRATION NUMBER: ClinicalTrials.gov identifier: NCT01991431.


Assuntos
Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Europa (Continente) , Feminino , Humanos , Masculino , Modelos de Riscos Proporcionais , Estudos Prospectivos , Sistema de Registros/estatística & dados numéricos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
4.
J Thorac Cardiovasc Surg ; 155(3): 915-923, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29221741

RESUMO

OBJECTIVE: It has been reported that balloon aortic valvuloplasty immediately before transfemoral or transapical transcatheter aortic valve implantation has mostly little to no clinical value. We aimed to provide data on the need for balloon aortic valvuloplasty in patients undergoing transaortic transcatheter aortic valve implantation. METHODS: Patients undergoing transaortic transcatheter aortic valve implantation with the Edwards SAPIEN XT (Nyon, Switzerland) or 3 transcatheter heart valve were prospectively included at 18 sites across Europe. In the present analysis, we compare the periprocedural and 30-day outcomes of patients undergoing conventional (+ balloon aortic valvuloplasty) versus direct (- balloon aortic valvuloplasty) transaortic transcatheter aortic valve implantation. RESULTS: Of the 300 patients enrolled, 222 underwent conventional and 78 underwent direct transaortic transcatheter aortic valve implantation. Peak and mean transvalvular gradients were improved in both groups with no significant difference between groups. Procedural duration, contrast agent volume, and requirement for postdilation were also comparable. A trend toward fewer periprocedural complications was evident in the direct group (3.9% vs 11.3%; P = .053), with significantly lower rates of permanent pacemaker implantation (0% vs 5.0%; P = .034). Balloon aortic valvuloplasty omission had no significant effect on any of the 30-day safety and efficacy outcomes, including Valve Academic Research Consortium-2 composite end points (early safety events: 22.7% vs 17.4%, odds ratio, 1.17, 95% confidence interval, 0.53-2.62; clinical efficacy events: 20.5% vs 18.7%, odds ratio, 1.14, 95% confidence interval, 0.51-2.55). CONCLUSIONS: For many patients, balloon aortic valvuloplasty predilation seems to have little clinical value in transaortic transcatheter aortic valve implantation using a balloon expandable transcatheter valve and may result in a higher rate of periprocedural complications, particularly in terms of permanent pacemaker implantation.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Europa (Continente) , Feminino , Hemodinâmica , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Interact Cardiovasc Thorac Surg ; 25(5): 757-764, 2017 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-28582580

RESUMO

OBJECTIVES: Transaortic (TAo) access for transcatheter aortic valve implantation (TAVI) is an alternative to the conventional transfemoral or transapical routes. Data comparing the characteristics and outcomes of TAo-TAVI using the SAPIEN XT and SAPIEN 3 heart valves are scarce. The objective of the current analysis was to provide such information. METHODS: ROUTE is an international, prospective, observational registry. Patients with severe calcific aortic stenosis scheduled for TAo-TAVI with an Edwards SAPIEN XT or a SAPIEN 3 heart valve were consecutively enrolled at 22 centres across Europe between February 2013 and February 2015. Periprocedural, in-hospital and 30-day complication rates were assessed. RESULTS: Of the 301 patients included, 126 (41.9%) received a SAPIEN 3 and 175 (58.1%) a SAPIEN XT. The SAPIEN 3 was associated with shorter procedure time (101 ± 35 vs 111 ± 40 min; P = 0.031) and a lower quantity of contrast agent used (87 ± 43 vs 112 ± 50 ml; P < 0.001). Balloon dilation was performed less often before (68.0% vs 78.3%; P = 0.045) and after implantation (13.6% vs 30.1%; P = 0.001). No statistically significant differences between the valve types were documented for overall (4.1% SAPIEN 3 vs 7.6% SAPIEN XT; P = 0.21), TAVI-related (0.8% vs 4.7%; P = 0.084) and cardiovascular mortality (2.4% vs 5.9%; P = 0.158). Major vascular complications were less frequent (0.8% vs 5.3%; P = 0.049), and there was a lower rate of moderate-to-severe paravalvular regurgitation (0.8% vs 5.1%; P = 0.050) in the SAPIEN 3 group. CONCLUSIONS: Both the SAPIEN XT and SAPIEN 3 were safely implanted via the TAo route, though the SAPIEN 3 may be associated with a higher procedural success rate and improved prognosis. ClinicalTrials.gov Identifier: NCT01991431.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Calcinose/cirurgia , Próteses Valvulares Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Calcinose/diagnóstico , Europa (Continente)/epidemiologia , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Resultado do Tratamento
6.
Eur J Cardiothorac Surg ; 51(5): 919-926, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28369303

RESUMO

OBJECTIVES: Transaortic transcatheter aortic valve implantation (TAo-TAVI) is a recently developed alternative to transapical (TA) or transfemoral (TF) TAVI. We aimed to analyse the effectiveness and safety of TAo-TAVI as a first line approach and to compare it to patients receiving TAo-TAVI as a last resort, which is current practice. METHODS: ROUTE is a prospective, multicentre registry to assess the clinical outcomes of TAo-TAVI. Patients without contraindications for TA- and TF-TAVI (TAo-first) were compared to patients with contraindications for both of these access routes (TAo-last). Outcome analysis was based on VARC II defined clinical end-points. RESULTS: Three hundred and one patients were included, of which 224 patients met TAo-first and 77 TAo-last criteria. The valve was delivered and catheter retrieved successfully in all patients. In the TAo-first group, rates of conversion to open surgery and requirement for a second valve were low and not different compared to TAo-last patients (1% vs. 3%, P = 0.46 and 1% vs. 3%, P = 0.46, respectively). This was also true for the rate of paravalvular regurgitation (≥ moderate: 4% vs. 3%). All-cause mortality at 30-days was 6% vs. 5% ( P = 0.76), rates of stroke 2% vs. 0% ( P = 0.24), pacemaker implantation (11% vs. 4%, P = 0.093), and life-threatening bleeding 4% vs. 3% ( P = 0.70). Valve safety (both 85%, P = 0.98) and clinical efficacy (80% vs. 82%; P = 0.73) did not differ between groups. CONCLUSIONS: Although comparative data to TA and TF procedures were not available in the present analysis, findings suggest that TAo may be considered not only as a last resort strategy when classical access routes are deemed unfeasible, but also as a potential first-line option, with only low rates of paravalvular regurgitation and permanent pacemaker implantation. CLINICALTRIALS.GOV: NCT01991431.


Assuntos
Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Complicações Pós-Operatórias , Estudos Prospectivos , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Resultado do Tratamento
7.
Can J Cardiol ; 33(2): 260-268, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28034581

RESUMO

BACKGROUND: Despite previously described feasibility, direct transcatheter aortic valve implantation (TAVI) with the Edwards SAPIEN S3 device (S3-THV) (Edwards Lifesciences, Irvine, CA) has not been compared with either a systematic or a selective predilation approach. METHODS: Patients undergoing predilation were divided into a systematic group (regardless of anatomic features) and a selective group (in the context of high valvular calcium burden). Both groups were matched in a 2:1 fashion to patients who underwent direct TAVI. Outcomes were assessed according to Valve Academic Research Consortium 2 (VARC-2) criteria. RESULTS: Two hundred eighty-one patients underwent TAVI with the S3-THV in our centre. Of these patients, 58 underwent predilation before device implantation (systematic, n = 26; selective, n = 32). Procedural success was achieved in all patients. Patients in the selective predilation group had severe valve calcification volume-more than double that of the systematic group (445 ± 306 mm3 vs 970 ± 578 mm3, respectively; P < 0.0001). There was a trend for less dilation after the procedure in the systematic group compared with the selective group (4% vs 19%, respectively; P = 0.09). Device malposition necessitating a second device to be implanted occurred in 3 cases of direct TAVI (5%) and in none of the patients undergoing predilation (P = not significant). Thirty-day and 1-year mortality rates were similar between the patients who underwent direct TAVI and their predilation counterparts. CONCLUSIONS: In patients with a moderate aortic valve calcification burden, direct TAVI appears to be feasible and safe. In those with high calcium burden, predilation should be considered after taking into account individual risk profiles.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Valvuloplastia com Balão/métodos , Calcinose/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Calcinose/diagnóstico , Ecocardiografia , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
8.
JACC Cardiovasc Interv ; 9(17): 1815-22, 2016 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-27609256

RESUMO

OBJECTIVES: The Registry of the Utilization of the TAo-TAVR approach using the Edwards SAPIEN Valve (ROUTE) was established to assess the effectiveness and safety of the use of transaortic (TAo) access for transcatheter aortic valve replacement (TAVR) procedures (NCT01991431). BACKGROUND: TAVR represents an alternative to surgical valve replacement in high-risk patients. Whereas the transfemoral access route is used commonly as the first-line approach, transapical access is an option for patients not suitable for transfemoral treatment mainly due to anatomic conditions. TAo-TAVR has been shown to be a viable alternative surgical access route; however, only limited data on its effectiveness and safety has been published. METHODS: ROUTE is a multicenter, international, prospective, observational registry; data were collected from 18 centers across Europe starting in February 2013. Patients having severe calcific aortic stenosis were documented if they were scheduled to undergo TAo-TAVR using an Edwards SAPIEN XT or a SAPIEN 3 valve. The primary endpoint was 30-day mortality. Secondary endpoints were intraprocedural or in hospital and 30-day complication rates. RESULTS: A total of 301 patients with a mean age of 81.7 ± 5.9 years and an Society of Thoracic Surgeons score of 9.0 ± 7.6% were included. Valve success was documented in 96.7%. The 30-day mortality was 6.1% (18/293) (procedure-related mortality: 3.1%; 9 of 293). The Valve Academic Research Consortium-2 defined complications included myocardial infarction (1.0%), stroke (1.0%), transient ischemic attack (0.3%), major vascular complications (3.4%), life-threatening bleeding (3.4%), and acute kidney injury (9.5%). In 3.3% of patients, paravalvular regurgitation was classified as moderate or severe (10 of 300). Twenty-six patients (8.8%) required permanent pacemaker implantation. CONCLUSIONS: TAo access for TAVR seems to be a safe alternative to the transapical procedure.


Assuntos
Aorta , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Calcinose/cirurgia , Implante de Prótese de Valva Cardíaca , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Calcinose/fisiopatologia , Europa (Continente) , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 86(6): 1105-13, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-25945689

RESUMO

BACKGROUND: Few data are available about whether aortic root calcification may impact the outcomes after transcatheter aortic valve implantation (TAVI). OBJECTIVES: This study sought to evaluate the impact of aortic root calcification volume on clinical outcome after TAVI with balloon expandable Edwards Sapien XT valve (Edwards Lifesciences, Irvine, California). METHODS: A total of 162 TAVI patients (aged 84.0 [Interquartile Range (IQR) 81.0-84.0] years, Logistic EuroSCORE 14.5 [IQR 9.8-25.1]) with preprocedural MDCT were studied. Aortic root calcification volume was measured by MDCT image and using the dedicated software for aortic valve assessment (the automated 3mensio™ Valves 5.1, sp1, 3mensio Pie Medical Imaging BV, Maastricht, the Netherlands). A valve calcification index (VCI) was defined as calcification volume (mm(3))/body surface area (mm(2)). RESULTS: VCI was significantly higher among patients with 30-day mortality. A VCI threshold of 517.4 (area under the curve 0.69, 95% CI 0.50-0.87, P = 0.03) predicted a higher incidence of annulus rupture (9.1 vs. 0.9%, P = 0.02) and cardiac tamponade (12.7 vs. 1.9%, P < 0.01), lower device success (83.6% vs. 95.3%, P < 0.01) and 30-day survival rate (80.0% vs. 97.2%, P < 0.01). Multivariate logistic regression analysis showed only ejection fraction and VCI were identified as independent predictors of 30-day mortality (Odds ratio 0.948 [95% confidence interval 0.909-0.988], P = 0.012, Odds ratio 1.003 [95% confidence interval 1.001-1.005], P = 0.013, respectively). CONCLUSIONS: Significantly worse acute clinical outcomes after Edwards valve implantation were observed in patients with large amount of aortic annulus calcifications quantitatively measured by dedicated MDCT software. Application of VCI may prove helpful in prediction of clinical outcomes after TAVI.


Assuntos
Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/terapia , Calcinose/diagnóstico , Causas de Morte , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Análise de Variância , Valva Aórtica/patologia , Estenose da Valva Aórtica/diagnóstico , Calcinose/mortalidade , Estudos de Coortes , Ecocardiografia Transesofagiana/métodos , Feminino , Seguimentos , Humanos , Imageamento Tridimensional , Masculino , Tomografia Computadorizada Multidetectores/métodos , Análise Multivariada , Países Baixos , Análise de Regressão , Estudos Retrospectivos , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
10.
BMC Cardiovasc Disord ; 14: 152, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-25361564

RESUMO

BACKGROUND: Transaortic transcatheter aortic valve implantation (TAo-TAVI) is a recently developed approach that provides an alternative delivery route for valve replacement in patients with vascular abnormalities or existing comorbidities. While initial studies have shown the principal efficacy and safety, the real world effectiveness and safety of this approach remains to be fully assessed. METHODS/DESIGN: In this regard, the Registry Of the Utilization of the TAo-TAVI approach using the Edwards SAPIEN Valve (ROUTE) represents the first multicenter, multinational prospective documentation of the course and outcome of patients with severe calcific aortic stenosis (AS) undergoing TAo-TAVI. ROUTE commenced in February 2013 with the goal of consecutively enrolling 300 patients at up to 22 sites across Europe. The primary objective of ROUTE is to determine the 30-day mortality associated with TAo-TAVI using the Edwards SAPIEN THV (Edwards Lifesciences, Irvine, CA). In addition, ROUTE aims to quantify complications, predictors of patient outcome and the value of CT guided valve sizing. DISCUSSION: Findings from this landmark registry will provide important information regarding procedural success rates and early mortality in patients undergoing TAo-TAVI. TRIAL REGISTRATION: Identifier: NCT01991431.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/patologia , Calcinose/terapia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Sistema de Registros , Projetos de Pesquisa , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Calcinose/diagnóstico , Calcinose/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Europa (Continente) , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
11.
Arch Cardiovasc Dis ; 106(5): 287-94, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23769403

RESUMO

BACKGROUND: Percutaneous mitral valve repair (MVR) using the MitraClip(®) is a new option for severe mitral regurgitation (MR). AIM: To describe initial French experience regarding short-term and mid-term safety and efficacy. METHODS: A multicentre cohort reported experience of percutaneous MVR using the MitraClip(®) in French centres from December 2010 to September 2012. All patients were judged inoperable or at high surgical risk. Short-term and mid-term safety and efficacy results are presented. RESULTS: Sixty-two patients (72.7±11.4years; 71.7% men; 81.0% New York Heart Association [NYHA] class III or IV; logistic Euroscore 18.7±13.1%; 93.3% MR≥grade 3; 73.8% secondary MR) underwent percutaneous MVR using the MitraClip(®) under general anaesthesia. Procedural success was 95.2% (83.1% of patients received one clip; 16.9% received two clips). At discharge, 88.2% of implanted patients had a residual MR≤grade 2. Transthoracic echocardiography showed a significant decrease in ejection fraction (39.9±14.8% pre vs. 36.2±14.3% post), end-diastolic diameter (63.8±10.6mm vs. 61.4±12.3mm, respectively) and systolic pulmonary pressure (52.1±13.9mmHg vs. 44.7±10.9mmHg, respectively). The in-hospital mortality rate was 3.2%. The survival rate at 6-month follow-up was estimated at 83.1%, with 90.9% of patients in NYHA class I or II and residual MR≤grade 2 in 80% of cases. CONCLUSION: This initial French experience, despite being in its learning phase, showed promising results in patients considered ineligible for surgery, as observed in more experienced centres. Randomized studies are mandatory to confirm these preliminary data.


Assuntos
Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral/instrumentação , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Instrumentos Cirúrgicos , Idoso , Idoso de 80 Anos ou mais , Anestesia Geral , Feminino , França , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento
12.
Eur J Cardiothorac Surg ; 44(4): 692-700, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23439694

RESUMO

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) in patients with poor peripheral vessels still remains problematic, as the transapical approach is not always feasible and is sometimes associated with myocardial damage, bleeding, post-procedural chest pain and pleural effusion. In order to address these issues, we adopted the recently introduced transaortic (TAo) approach. The purpose of this study was to evaluate the efficacy and safety of the TAo-TAVI approach using both the Sapien XT and the CoreValve according to VARC criteria. METHODS: Of 492 patients (October 2006 to February 2012), TAo-TAVI was performed in 94 consecutive patients with unfavourable peripheral access between January 2011 and February 2012. Aortic root condition, valve anatomy and annulus size were carefully assessed by multidetector computed tomography (MDCT) for possible TAo-TAVI. The aorta was exposed through an inverted 'T' manubriotomy. After retrograde guidewire crossing of the aortic valve, sheath insertion allowed device positioning and deployment subsequent to balloon valvuloplasty. RESULTS: Mean age was 84.1 ± 5.4 years (67-96) and logistic EuroSCORE 17.6 ± 10.2%. The Sapien XT was used in 88.3% and the CoreValve in 11.7% of patients. Full sternotomy allowed concomitant complete off-pump revascularization (2-4 grafts) in 11 patients. Device success rate was 92.6%. Paravalvular leak ≥2/4 was observed in 7.4%. Conversion to open chest surgery was required in 5.3% (3 aortic dissections, 1 valve migration and 1 left main occlusion). Three cerebrovascular accidents (2 transient ischaemia and 1 delayed stroke) were noted. Transfusion ≥4 units was performed in 12 patients (12.8%). Intensive care unit (ICU) and total hospital stay were 4.9 ± 5.0 and 12.2 ± 6.2 days, respectively. Thirty-day mortality and combined safety endpoint were reported in 7.4 and 16.0%, respectively. CONCLUSIONS: The TAo approach for both Sapien XT and CoreValve implantation can be used with satisfactory clinical outcome and an acceptable risk. This access route could prove a valid alternative to the transapical approach.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta/cirurgia , Cateterismo Cardíaco/métodos , Feminino , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 82(5): E742-6, 2013 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-22718400

RESUMO

Although annulus rupture is one of the most severe complications of transcatheter aortic valve implantation (TAVI), the incidence and mechanism of this complication remain unclear. Out of 387 consecutive TAVI cases in our institution, the incidence of annulus rupture was 1.0% (4/387). The first two patients died because of hemodynamic collapse due to tamponade on day 0. Both surviving patients had undergone preprocedural multidetector computed tomography which revealed large calcifications in the epicardial fat part of the aortic annulus. In both cases, annulus rupture occurred after deployment of a balloon expandable valve suggesting that mechanical compression of this "vulnerable area" by calcification may cause annulus rupture.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/lesões , Valva Aórtica/patologia , Calcinose/terapia , Cateterismo Cardíaco/efeitos adversos , Ruptura Cardíaca/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Valvuloplastia com Balão/efeitos adversos , Calcinose/diagnóstico , Cateterismo Cardíaco/métodos , Tamponamento Cardíaco/etiologia , Evolução Fatal , Feminino , Ruptura Cardíaca/diagnóstico , Ruptura Cardíaca/fisiopatologia , Ruptura Cardíaca/terapia , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
14.
J Am Coll Cardiol ; 59(6): 566-71, 2012 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-22300690

RESUMO

OBJECTIVES: The purpose of this study was to clarify the impact of sex-related differences in transcatheter aortic valve implantation (TAVI) for high-risk patients with severe aortic stenosis. BACKGROUND: Although TAVI is becoming a mature technique, the impact of sex differences remains unclear. METHODS: The TAVI patients were included prospectively in a dedicated database from October 2006. The proportion of women (n = 131) was similar to that of men (n = 129). The Edwards valve (85.4%) and CoreValve (14.6%) were used through the transfemoral (65.0%), subclavian (3.1%), or transapical (31.9%) approach. All events were defined according to Valve Academic Research Consortium criteria. RESULTS: Age was similar (83.1 ± 6.3 years), but women had less coronary and peripheral disease, less previous cardiac surgery, higher ejection fraction, and lower EuroSCORE (European System for Cardiac Operative Risk Evaluation [22.3 ± 9.0% vs. 26.2 ± 13.0%, p = 0.005]). Minimal femoral size (7.74 ± 1.03 mm vs. 8.55 ± 1.34 mm, p < 0.001), annulus size (20.9 ± 1.4 vs. 22.9 ± 1.7 mm, p < 0.001), and valve size (23.9 ± 1.6 mm vs. 26.3 ± 1.5 mm, p < 0.001) were smaller in women. Device success was similar (90.8% vs. 88.4%, p = 0.516) despite more frequent iliac complications (9.0% vs. 2.5%, p = 0.030). Residual mean aortic pressure gradient (11.6 ± 4.9 vs. 10.9 ± 4.9, p = 0.279) was also similar. The 1-year survival rate was higher for women, 76% (95% confidence interval: 72% to 80%), than for men, 65% (95% confidence interval: 60% to 69%); and male sex (hazard ratio: 1.62, 95% confidence interval: 1.03 to 2.53, p = 0.037) was identified as a predictor of midterm mortality by Cox regression analysis. CONCLUSIONS: Female sex is associated with better baseline clinical characteristics and improved survival, and is identified as a predictor of midterm survival after TAVI.


Assuntos
Estenose da Valva Aórtica/epidemiologia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Complicações Pós-Operatórias/epidemiologia , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Feminino , Seguimentos , França/epidemiologia , Humanos , Incidência , Masculino , Estudos Prospectivos , Fatores de Risco , Índice de Gravidade de Doença , Distribuição por Sexo , Fatores Sexuais , Taxa de Sobrevida/tendências
15.
JACC Cardiovasc Interv ; 5(2): 207-14, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22361606

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the incidence of vascular complications and the predictors of Prostar failure for a "true percutaneous approach" in transfemoral transcatheter aortic valve implantation (TAVI). BACKGROUND: Safety and efficacy of a true percutaneous approach in transfemoral-TAVI has not been described in a large prospective cohort. METHODS: Among 264 patients included in our prospective TAVI database (October 2006 to December 2010), transfemoral-TAVI was performed in 170 patients. True percutaneous approach was performed in 142 consecutive patients since March 2008. Successful closure with Prostar was defined as adequate hemostasis without Prostar-related vascular complications. We compared the incidence of vascular complications in our early and late experience. RESULTS: Patients were 83.0±7.2 years old and with a EuroSCORE of 24.0±11.6%. The Edwards valve (Edwards Lifesciences, Irvine, California) (18- to 24-F) was used in 109 cases and the CoreValve (Medtronic, Minneapolis, Minnesota) (18-F) in 31. The sheath outer diameter to minimal femoral diameter ratio (SFAR) was 0.96±0.14. Successful closure was achieved in 90.7%, and was significantly increased (95.7% vs. 85.7%, p=0.047) in the late experience group. Cross-over to surgery was required in 3.6%. Vascular complications occurred in 20.0%, and were significantly lower in the late experience group (11.4% vs. 28.6%, p=0.012). Major vascular complications (2.9% vs. 14.3%, p=0.018) were decreased in the late experience group. Early experience (hazard ratio [HR]: 3.66, 95% confidence interval [CI]: 1.04 to 13.89, p=0.047) and SFAR (HR: 110.80, 95% CI: 1.15 to 10,710.73, p=0.044) predicted Prostar failure by univariate analysis. CONCLUSIONS: Experience reduced major vascular complications in a true percutaneous approach for transfemoral-TAVI. Further application of this less invasive strategy is feasible and may be beneficial, in this high-risk patient cohort.


Assuntos
Estenose da Valva Aórtica/patologia , Valva Aórtica/patologia , Competência Clínica , Implante de Prótese de Valva Cardíaca/instrumentação , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Intervalos de Confiança , Falha de Equipamento , Feminino , Indicadores Básicos de Saúde , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Aprendizagem , Curva de Aprendizado , Masculino , Estudos Prospectivos , Estatísticas não Paramétricas , Falha de Tratamento
16.
Presse Med ; 40(7-8): 732-9, 2011.
Artigo em Francês | MEDLINE | ID: mdl-21511426

RESUMO

As the French population is aging, a growing number of elderly patients with symptomatic severe aortic stenosis are going to require therapeutic management. Approximately 30 to 40% of these patients do not undergo surgical treatment and a high proportion is considered to be at high risk for surgery. The transluminal aortic valve implantation technique has been increasingly used over the past few years, thus providing a solution to a major therapeutic issue in our industrialized countries. While the cardiology community was rapidly convinced of its efficacy, remaining doubts regarding the outcome of this technique in terms of mortality were erased by the recent publication of results achieved in cohort B of the Partner US trial. This new approach is clearly here to stay and should soon reach a maturity phase with respect to its indications, the selection of patients and technical aspects.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Ensaios Clínicos como Assunto , Próteses Valvulares Cardíacas , Humanos , Desenho de Prótese
17.
J Cardiothorac Vasc Anesth ; 20(4): 484-92, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16884977

RESUMO

OBJECTIVE: Sevoflurane could decrease myocardial ischemic injury in patients undergoing off-pump coronary artery bypass surgery. This study was designed to compare postoperative troponin I (cTnI) concentrations after sevoflurane-remifentanil versus propofol-remifentanil anesthesia. DESIGN: Prospective, randomized single-blind clinical study. SETTING: University hospital. PARTICIPANTS: Eighteen patients. INTERVENTIONS: General anesthesia was conducted with sevoflurane-remifentanil (n = 9) or propofol-remifentanil (n = 9). Administration of sevoflurane and propofol was adjusted to maintain the bispectral index (BIS) between 40 and 60. MEASUREMENTS AND MAIN RESULTS: Groups were comparable regarding the patients' characteristics. The objective of BIS was maintained in both groups except during the period of coronary artery grafts (p < 0.001) when the BIS number in the propofol group fell below 40 and was significantly lower than in the sevoflurane group. Intraoperative hemodynamic variables were similar between groups. No patient required cardiopulmonary bypass. Need for inotropic and vasoactive support during the first graft was not necessary in the propofol group and occurred in 4 patients in the sevoflurane group (not significant). During the second graft, 2 patients in the propofol group and 3 in the sevoflurane group needed hemodynamic support. Postoperative hemodynamic variables were comparable between groups. Areas under the curve of postoperative increases in cTnI were 27.0 +/- 38.6 and 17.4 +/- 14.6 ng/mL/hour in the sevoflurane and propofol groups, respectively (not significant). CONCLUSION: This study does not support cardioprotective effects of sevoflurane. The particularly short total cumulative duration of ischemia and the relatively low administered end-tidal sevoflurane concentrations may explain this result.


Assuntos
Anestésicos Combinados , Anestésicos Inalatórios/administração & dosagem , Anestésicos Intravenosos/administração & dosagem , Ponte de Artéria Coronária sem Circulação Extracorpórea , Eletroencefalografia , Éteres Metílicos/administração & dosagem , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Piperidinas/administração & dosagem , Propofol/administração & dosagem , Anestesia Geral , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Remifentanil , Sevoflurano , Método Simples-Cego , Troponina I/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA