Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Neurointerv Surg ; 13(2): 102-108, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33115813

RESUMO

BACKGROUND: Implantable brain-computer interfaces (BCIs), functioning as motor neuroprostheses, have the potential to restore voluntary motor impulses to control digital devices and improve functional independence in patients with severe paralysis due to brain, spinal cord, peripheral nerve or muscle dysfunction. However, reports to date have had limited clinical translation. METHODS: Two participants with amyotrophic lateral sclerosis (ALS) underwent implant in a single-arm, open-label, prospective, early feasibility study. Using a minimally invasive neurointervention procedure, a novel endovascular Stentrode BCI was implanted in the superior sagittal sinus adjacent to primary motor cortex. The participants undertook machine-learning-assisted training to use wirelessly transmitted electrocorticography signal associated with attempted movements to control multiple mouse-click actions, including zoom and left-click. Used in combination with an eye-tracker for cursor navigation, participants achieved Windows 10 operating system control to conduct instrumental activities of daily living (IADL) tasks. RESULTS: Unsupervised home use commenced from day 86 onwards for participant 1, and day 71 for participant 2. Participant 1 achieved a typing task average click selection accuracy of 92.63% (100.00%, 87.50%-100.00%) (trial mean (median, Q1-Q3)) at a rate of 13.81 (13.44, 10.96-16.09) correct characters per minute (CCPM) with predictive text disabled. Participant 2 achieved an average click selection accuracy of 93.18% (100.00%, 88.19%-100.00%) at 20.10 (17.73, 12.27-26.50) CCPM. Completion of IADL tasks including text messaging, online shopping and managing finances independently was demonstrated in both participants. CONCLUSION: We describe the first-in-human experience of a minimally invasive, fully implanted, wireless, ambulatory motor neuroprosthesis using an endovascular stent-electrode array to transmit electrocorticography signals from the motor cortex for multiple command control of digital devices in two participants with flaccid upper limb paralysis.


Assuntos
Atividades Cotidianas , Interfaces Cérebro-Computador , Neuroestimuladores Implantáveis , Córtex Motor/fisiologia , Paralisia/terapia , Índice de Gravidade de Doença , Atividades Cotidianas/psicologia , Idoso , Interfaces Cérebro-Computador/psicologia , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Córtex Motor/diagnóstico por imagem , Paralisia/diagnóstico por imagem , Paralisia/fisiopatologia , Estudos Prospectivos
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 1074-1077, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30440577

RESUMO

Access to the brain to implant recording electrodes has conventionally required a craniotomy. To mitigate risks of open brain surgery, we previously developed a stent-electrode array that can be delivered to the cortex via cerebral vessels. Following implantation of a stent-electrode array (Stentrode) in a large animal model, we investigated the longevity of highquality signals, by measuring bandwidth in animals implanted for up to six months; no signal degradation was observed. We also investigated whether bandwidth was influenced by implant location with respect to the superior sagittal sinus and branching cortical veins; it was not. Finally, we assessed whether electrode orientation had an impact on recording quality. There was no significant difference in bandwidths from electrodes facing different orientations. Interestingly, electrodes facing the skull (180°) were still able to record neural information with high fidelity. Consequently, a minimally invasive surgical approach combined with a stent-electrode array is a safe and efficacious technique to acquire neural signals over a chronic duration.


Assuntos
Córtex Cerebral , Stents , Animais , Encéfalo , Eletrodos Implantados
3.
Nat Biomed Eng ; 2(12): 907-914, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-31015727

RESUMO

Direct electrical stimulation of the brain can alleviate symptoms associated with Parkinson's disease, depression, epilepsy and other neurological disorders. However, access to the brain requires invasive procedures, such as the removal of a portion of the skull or the drilling of a burr hole. Also, electrode implantation into tissue can cause inflammatory tissue responses and brain trauma, and lead to device failure. Here, we report the development and application of a chronically implanted platinum electrode array mounted on a nitinol endovascular stent for the localized stimulation of cortical tissue from within a blood vessel. Following percutaneous angiographic implantation of the device in sheep, we observed stimulation-induced responses of the facial muscles and limbs of the animals, similar to those evoked by electrodes implanted via invasive surgery. Proximity of the electrode to the motor cortex, yet not its orientation, was integral to achieving reliable responses from discrete neuronal populations. The minimally invasive endovascular surgical approach offered by the stent-mounted electrode array might enable safe and efficacious stimulation of focal regions in the brain.


Assuntos
Córtex Motor/fisiologia , Stents , Angiografia , Animais , Estimulação Elétrica , Eletrodos Implantados , Procedimentos Endovasculares , Extremidades/fisiologia , Músculos Faciais/fisiologia , Ovinos
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 4455-4458, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28269267

RESUMO

Development of a neural interface that can be implanted without risky, open brain surgery will increase the safety and viability of chronic neural recording arrays. We have developed a minimally invasive surgical procedure and an endovascular electrode-array that can be delivered to overlie the cortex through blood vessels. Here, we describe feasibility of the endovascular interface through electrode viability, recording potential and safety. Electrochemical impedance spectroscopy demonstrated that electrode impedance was stable over 91 days and low frequency phase could be used to infer electrode incorporation into the vessel wall. Baseline neural recording were used to identify the maximum bandwidth of the neural interface, which remained stable around 193 Hz for six months. Cross-sectional areas of the implanted vessels were non-destructively measured using the Australian Synchrotron. There was no case of occlusion observed in any of the implanted animals. This work demonstrates the feasibility of an endovascular neural interface to safely and efficaciously record neural information over a chronic time course.


Assuntos
Córtex Cerebral/fisiologia , Eletrodos Implantados , Procedimentos Endovasculares , Animais , Interfaces Cérebro-Computador , Córtex Cerebral/cirurgia , Espectroscopia Dielétrica , Ovinos , Stents
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA