Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
2.
Eur J Gastroenterol Hepatol ; 36(9): 1087-1092, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38916233

RESUMO

Colon capsule endoscopy (CCE) is a well-known method for the detection of colorectal lesions. Nevertheless, there are no studies reporting the accuracy of TOP 100, a CCE software tool, for the automatic detection of colorectal lesions in CCE. We aimed to evaluate the performance of TOP 100 in detecting colorectal lesions in patients submitted to CCE for incomplete colonoscopy compared with classic reading. A retrospective cohort study including adult patients submitted to CCE (PillCam COLON 2; Medtronic) for incomplete colonoscopy. Blinded for each other's evaluation, one experienced reader analyzed the TOP 100 images and the other performed classic reading to identify colorectal lesions. Detection of colorectal lesions, namely polyps, angioectasia, blood, diverticula, erosions/ulcers, neoplasia, and subepithelial lesions was assessed and TOP 100 performance was evaluated compared with the gold standard (classic reading). A total of 188 CCEs were included. Prevalence of colorectal lesions, polyps, angioectasia, blood, diverticula, erosions/ulcers, neoplasia, and subepithelial lesions were 77.7, 54.3, 8.5, 1.6, 50.0, 0.5, 0.5, and 1.1%, respectively. TOP 100 had a sensitivity of 92.5%, specificity of 69.1%, negative predictive value of 72.5%, positive predictive value of 91.2%, and accuracy of 87.2% for detecting colorectal lesions. TOP 100 had a sensitivity of 89.2%, specificity of 84.9%, negative predictive value of 86.9%, positive predictive value of 87.5%, and accuracy of 87.2% in detecting polyps. All colorectal lesions other than polyps were identified with 100% accuracy by TOP 100. TOP 100 has been shown to be a simple and useful tool in assisting the reader in the prompt identification of colorectal lesions in CCE.


Assuntos
Endoscopia por Cápsula , Colonoscopia , Neoplasias Colorretais , Valor Preditivo dos Testes , Humanos , Endoscopia por Cápsula/métodos , Feminino , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Idoso , Neoplasias Colorretais/diagnóstico , Colonoscopia/métodos , Pólipos do Colo/diagnóstico , Pólipos do Colo/patologia , Pólipos do Colo/diagnóstico por imagem , Adulto , Software , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Interpretação de Imagem Assistida por Computador , Idoso de 80 Anos ou mais
3.
GE Port J Gastroenterol ; 31(2): 89-100, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38572440

RESUMO

Background: The role of capsule endoscopy in the evaluation of the small bowel is well established, and current guidelines position it as a first-line test in a variety of clinical scenarios. The advent of double-headed capsules further enabled the endoscopic assessment of colonic mucosa and the opportunity for a one-step noninvasive examination of the entire bowel (pan-enteric capsule endoscopy [PCE]). Summary: We reviewed the technical procedure and preparation of patients for PCE, as well as its current clinical applications and future perspectives. In non-stricturing and non-penetrating Crohn's disease affecting the small bowel and colon, PCE monitors disease activity by assessing mucosal healing, a major treatment outcome, with a higher diagnostic yield than cross-sectional imaging or conventional colonoscopy. Also in ulcerative colitis, double-headed capsules have been used to monitor disease activity noninvasively. Currently, validated scoring systems have been specifically devised for these double-headed capsules and permit a standardized assessment of the inflammatory burden. In suspected mid-lower digestive bleeding, some exploratory studies have demonstrated the feasibility and high diagnostic yield of PCE, which may work as a filter indicating which patients may benefit of further invasive procedures, namely, for planned hemostatic procedures. The possibility of using PCE is also discussed in the context of polyposis syndromes with simultaneous involvement of the small intestine and colon. Key Messages: PCE is a feasible, effective, and safe diagnostic procedure to evaluate the small bowel and colon. It has been increasingly explored in the setting of inflammatory bowel diseases and, more recently, in suspected mid-lower digestive bleeding. PCE is expected to reduce the demand for invasive procedures and expand the scope of noninvasive intestinal evaluation in the coming future.


Introdução: O papel da endoscopia por cápsula na avaliação do intestino delgado encontra-se bem estabelecido, e as orientações atuais posicionam-na como um teste de primeira linha numa variedade de cenários clínicos. O advento das cápsulas de dupla câmara permitiu expandir a sua aplicação para a avaliação endoscópica da mucosa do cólon, oferecendo a oportunidade de um exame não invasivo de todo o intestino (endoscopia pan-entérica por cápsula, PCE). Sumário: Procedemos a uma revisão de vários aspectos do procedimento e preparação dos doentes para a PCE, bem como as aplicações clínicas atuais e as perspetivas futuras das cápsulas de dupla câmara. Na doença de Crohn não estenosante e não penetrante localizada ao intestino delgado e cólon, a PCE permite monitorizar a atividade da doença e avaliar a cicatrização da mucosa, um indicador importante da eficácia da terapêutica, com um rendimento de diagnóstico superior aos métodos convencionais, nomeadamente os exames imagiológicos ou a colonoscopia invasiva. Também na colite ulcerosa, as cápsulas de dupla câmara têm sido utilizadas para monitorizar a atividade da doença de forma não invasiva. Existem índices endoscópicos validados e especificamente concebidos para as cápsulas de dupla câmara, que permitem uma avaliação sistematizada e quantificação objetiva da atividade inflamatória. Na suspeita de hemorragia digestiva média ou baixa, alguns estudos exploratórios demonstraram a aplicabilidade e o elevado rendimento diagnóstico da PCE, podendo funcionar como um filtro de modo a permitir indicar quais os doentes que mais irão beneficiar de um procedimento invasivo subsequente, nomeadamente para a realização de procedimentos hemostáticos dirigidos. A possibilidade de utilização da PCE é também discutida no contexto das síndromes de polipose com envolvimento simultâneo do intestino delgado e do cólon. Mensagens-chave: A PCE é um procedimento diagnóstico eficaz e seguro para avaliar diretamente a mucosa do intestino delgado e cólon. A sua aplicação tem vindo a expandir-se no contexto das Doenças Inflamatórias Intestinais e, mais recentemente, na suspeita de hemorragia digestiva média ou baixa. Existe a expectativa de que no futuro próximo possamos assistir a uma redução substancial da demanda por procedimentos endoscópicos invasivos, face à utilização crescente da PCE enquanto método de diagnóstico pan-intestinal não invasivo.

4.
World J Gastroenterol ; 30(10): 1270-1279, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38596501

RESUMO

In 2000, the small bowel capsule revolutionized the management of patients with small bowel disorders. Currently, the technological development achieved by the new models of double-headed endoscopic capsules, as miniaturized devices to evaluate the small bowel and colon [pan-intestinal capsule endoscopy (PCE)], makes this non-invasive procedure a disruptive concept for the management of patients with digestive disorders. This technology is expected to identify which patients will require conventional invasive endoscopic procedures (colonoscopy or balloon-assisted enteroscopy), based on the lesions detected by the capsule, i.e., those with an indication for biopsies or endoscopic treatment. The use of PCE in patients with inflammatory bowel diseases, namely Crohn's disease, as well as in patients with iron deficiency anaemia and/or overt gastrointestinal (GI) bleeding, after a non-diagnostic upper endoscopy (esophagogastroduodenoscopy), enables an effective, safe and comfortable way to identify patients with relevant lesions, who should undergo subsequent invasive endoscopic procedures. The recent development of magnetically controlled capsule endoscopy to evaluate the upper GI tract, is a further step towards the possibility of an entirely non-invasive assessment of all the segments of the digestive tract, from mouth-to-anus, meeting the expectations of the early developers of capsule endoscopy.


Assuntos
Endoscopia por Cápsula , Doença de Crohn , Enteropatias , Humanos , Endoscopia por Cápsula/efeitos adversos , Endoscopia por Cápsula/métodos , Endoscopia Gastrointestinal/efeitos adversos , Endoscopia Gastrointestinal/métodos , Enteropatias/patologia , Doença de Crohn/diagnóstico , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/cirurgia , Intestino Delgado/patologia , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/diagnóstico
5.
Endoscopy ; 56(8): 572-580, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38365215

RESUMO

BACKGROUND: Pan-intestinal capsule endoscopy (PCE) evaluates the small bowel and colon noninvasively. This study evaluated diagnostic accuracy and safety of PCE vs. colonoscopy as first-line examination in suspected mid-lower gastrointestinal bleeding (MLGIB). METHODS: In this prospective, single-center, single-blinded cohort study, consecutive patients with suspected MLGIB underwent PCE followed by same-day colonoscopy. Diagnostic accuracy for potentially hemorrhagic lesions (PHLs; combined diagnosis by PCE + colonoscopy) and incidence of adverse events were assessed. RESULTS: 100 patients were included (median age 70 [range 18-92] years; 65% female). PHLs were diagnosed in 46 patients, including small-bowel and/or colon angioectasias in 32. PCE correctly identified 54 individuals without PHLs, and 95.7% (44/46) of those with PHLs vs. 50.0% (23/46) for colonoscopy (P<0.01). PHLs were detected by PCE alone in 65.2% (30/46), both examinations in 28.3% (13/46), and colonoscopy alone in 6.5% (3/46). PHLs were diagnosed at the ileocolonic region in 28% of patients, with PCE diagnosing 25/28 cases (89.3%) and colonoscopy diagnosing 23/28 (82.1%; P=0.13). Interventional procedures were performed at colonoscopy in 13/81 patients with iron-deficiency anemia (16.0%) vs. 6/19 patients with overt bleeding (31.6%; P<0.01). No significant adverse events occurred with PCE vs. 2% with colonoscopy. CONCLUSIONS: In patients with MLGIB, PCE avoided further invasive procedures in >50% of patients. PCE was safe and more effective than colonoscopy in identifying PHL both in the small bowel and colon. These results support the potential use of PCE as first-line examination in patients with suspected MLGIB.


Assuntos
Endoscopia por Cápsula , Colonoscopia , Hemorragia Gastrointestinal , Humanos , Endoscopia por Cápsula/métodos , Feminino , Masculino , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Idoso , Pessoa de Meia-Idade , Colonoscopia/métodos , Colonoscopia/efeitos adversos , Adulto , Estudos Prospectivos , Idoso de 80 Anos ou mais , Adolescente , Método Simples-Cego , Adulto Jovem , Intestino Delgado/diagnóstico por imagem
6.
J Craniomaxillofac Surg ; 52(4): 469-471, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38369394

RESUMO

The aim of this study is to present a sequential strategy of soft-tissue, non-osteogenic distraction with a novel device, followed by microvascular bony reconstruction for severe cases of mandibular hypoplasia. The case of a 21-year-old woman with Goldenhar syndrome is presented, whose mandible remained severely hypoplastic despite previous attempts at distraction and was not suitable for further osteogenic distraction. Soft tissue deficiency and pin track scarring prevented free fibular transfers. A personalized distractor, anchored to the cranium and the mandibular symphysis, was designed to expand the soft tissues while allowing for physiological temporomandibular joint (TMJ) movement without compression forces. Internal distractors were placed along the osteotomies to prevent condylar luxation. After completion of the soft tissue distraction, the native mandible was resected except for the condyles and reconstructed with two free fibula flaps. This report represents the proof of concept of a sequential approach to severe lower face soft-tissue and bone deficiency, which preserves TMJ function and avoids the transfer of poorly matched skin to the face.


Assuntos
Síndrome de Goldenhar , Micrognatismo , Osteogênese por Distração , Procedimentos de Cirurgia Plástica , Feminino , Humanos , Adulto Jovem , Adulto , Síndrome de Goldenhar/diagnóstico por imagem , Síndrome de Goldenhar/cirurgia , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Mandíbula/anormalidades , Micrognatismo/cirurgia , Crânio/cirurgia
7.
Sci Adv ; 10(3): eadj1984, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38241380

RESUMO

Precise manipulation of flexible surgical tools is crucial in minimally invasive surgical procedures, necessitating a miniature and flexible robotic probe that can precisely direct the surgical instruments. In this work, we developed a polymer-based robotic fiber with a thermal actuation mechanism by local heating along the sides of a single fiber. The fiber robot was fabricated by highly scalable fiber drawing technology using common low-cost materials. This low-profile (below 2 millimeters in diameter) robotic fiber exhibits remarkable motion precision (below 50 micrometers) and repeatability. We developed control algorithms coupling the robot with endoscopic instruments, demonstrating high-resolution in situ molecular and morphological tissue mapping. We assess its practicality and safety during in vivo laparoscopic surgery on a porcine model. High-precision motion of the fiber robot delivered endoscopically facilitates the effective use of cellular-level intraoperative tissue identification and ablation technologies, potentially enabling precise removal of cancer in challenging surgical sites.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Suínos , Animais , Procedimentos Cirúrgicos Robóticos/métodos , Laparoscopia/métodos , Procedimentos Cirúrgicos Minimamente Invasivos
8.
Dig Dis Sci ; 68(12): 4418-4431, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37833441

RESUMO

BACKGROUND: The rate of adequate cleansing (ACR) and complete examinations (CR) are key quality indicators in capsule colonoscopy (CC) and pan-intestinal capsule endoscopy (PCE). AIMS: To evaluate the efficacy of bowel preparation protocols regarding ACR and CR. METHODS: We conducted a systematic review and meta-analysis, search terms regarding colon capsule preparation, publication date from 2006/01, and date of search 2021/12, in six bibliographic databases. Multiple steps of the cleansing protocol were assessed: diet, adjunctive laxatives, purgative solution, use of prokinetic agents, and "booster". The meta-analytical frequency of ACR and CR was estimated, and subgroup analyses performed. Strategies associated with higher ACR and CR were explored using meta-analytical univariable and multivariable regression models. RESULTS: Twenty-six observational studies and five RCTs included (n = 4072 patients). The pooled rate of ACR was 72.5% (95% C.I. 67.8-77.5%; I2 = 92.4%), and the pooled rate of CR was 83.0% (95% C.I. 78.7-87.7%; I2 = 96.5%). The highest ACR were obtained using a low-fibre diet [78.5% (95% C.I. 72.0-85.6%); I2 = 57.0%], adjunctive laxatives [74.7% (95% C.I. 69.8-80.1%); I2 = 85.3%], and split dose < 4L polyethylene glycol (PEG) as purgative [77.5% (95% C.I. 68.4-87.8%); I2 = 47.3%]. The highest CR were observed using routine prokinetics prior to capsule ingestion [84.4% (95% C.I. 79.9-89.2%); I2 = 89.8%], and sodium phosphate (NaP) as "booster" [86.2% (95% C.I. 82.3-90.2%); I2 = 86.8%]. In univariable models, adjunctive laxatives were associated with higher ACR [OR 1.81 (95% C.I. 1.13; 2.90); p = 0.014]. CR was higher with routine prokinetics [OR 1.86 (95% C.I. 1.13; 3.05); p = 0.015] and split-dose PEG purgative [OR 2.03 (95% C.I. 1.01; 4.09), p = 0.048]. CONCLUSIONS: Main quality outcomes (ACR, CR) remain suboptimal for CC and PCE. Despite considerable heterogeneity, our results support low-fibre diet, use of adjunctive sennosides, split dose < 4L PEG, and routine prokinetics, while NaP remains the most consistent option as booster.


Assuntos
Endoscopia por Cápsula , Catárticos , Humanos , Laxantes , Endoscopia por Cápsula/métodos , Colonoscopia/métodos , Polietilenoglicóis
10.
Endoscopy ; 55(1): 58-95, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36423618

RESUMO

MR1: ESGE recommends small-bowel capsule endoscopy as the first-line examination, before consideration of other endoscopic and radiological diagnostic tests for suspected small-bowel bleeding, given the excellent safety profile of capsule endoscopy, its patient tolerability, and its potential to visualize the entire small-bowel mucosa.Strong recommendation, moderate quality evidence. MR2: ESGE recommends small-bowel capsule endoscopy in patients with overt suspected small-bowel bleeding as soon as possible after the bleeding episode, ideally within 48 hours, to maximize the diagnostic and subsequent therapeutic yield.Strong recommendation, high quality evidence. MR3: ESGE does not recommend routine second-look endoscopy prior to small-bowel capsule endoscopy in patients with suspected small-bowel bleeding or iron-deficiency anemia.Strong recommendation, low quality evidence. MR4: ESGE recommends conservative management in those patients with suspected small-bowel bleeding and high quality negative small-bowel capsule endoscopy.Strong recommendation, moderate quality evidence. MR5: ESGE recommends device-assisted enteroscopy to confirm and possibly treat lesions identified by small-bowel capsule endoscopy.Strong recommendation, high quality evidence. MR6: ESGE recommends the performance of small-bowel capsule endoscopy as a first-line examination in patients with iron-deficiency anemia when small bowel evaluation is indicated.Strong recommendation, high quality evidence. MR7: ESGE recommends small-bowel capsule endoscopy in patients with suspected Crohn's disease and negative ileocolonoscopy findings as the initial diagnostic modality for investigating the small bowel, in the absence of obstructive symptoms or known bowel stenosis.Strong recommendation, high quality evidence. MR8: ESGE recommends, in patients with unremarkable or nondiagnostic findings from dedicated small-bowel cross-sectional imaging, small-bowel capsule endoscopy as a subsequent investigation if deemed likely to influence patient management.Strong recommendation, low quality evidence. MR9: ESGE recommends, in patients with established Crohn's disease, the use of a patency capsule before small-bowel capsule endoscopy to decrease the capsule retention rate.Strong recommendation, moderate quality evidence. MR10: ESGE recommends device-assisted enteroscopy (DAE) as an alternative to surgery for foreign bodies retained in the small bowel requiring retrieval in patients without acute intestinal obstruction.Strong recommendation, moderate quality evidence. MR11: ESGE recommends DAE-endoscopic retrograde cholangiopancreatography (DAE-ERCP) as a first-line endoscopic approach to treat pancreaticobiliary diseases in patients with surgically altered anatomy (except for Billroth II patients).Strong recommendation, moderate quality evidence.


Assuntos
Anemia Ferropriva , Endoscopia por Cápsula , Doença de Crohn , Enteropatias , Humanos , Anemia Ferropriva/diagnóstico , Anemia Ferropriva/etiologia , Anemia Ferropriva/terapia , Endoscopia Gastrointestinal/métodos , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Enteropatias/diagnóstico , Enteropatias/terapia
11.
GE Port J Gastroenterol ; 29(5): 311-321, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36159193

RESUMO

Introduction: In order to optimize the rate of adequate cleansing in colon capsule, it may be important to identify risk factors that can predict a suboptimal colon preparation. Aim: To define predictive factors for inadequate bowel preparation in colon capsule, according to CC-CLEAR (Colon Capsule CLEansing Assessment and Report). Methods: Retrospective, single center, cohort study. Patients' demographics, data, and quality of bowel preparation, according to CC-CLEAR, were collected retrospectively. A univariate analysis tested the association between covariables and the outcome, inadequate cleansing. The statistically significant variables were included in multivariable logistic binary regression, and a receiver operating characteristic curve (ROC) assessment was performed. Results: We included 167 consecutive colon capsules. Sixty-eight percent (n = 114) of patients were female, with a mean age of 64 years. The main indication for colon capsule was previous incomplete colonoscopy, in 158 patients (94.6%). The colon capsules cleansing was graded as good or excellent in 96 patients (57.5%) and as inadequate in 71 (42.5%), according to CC-CLEAR. The variables inadequate previous colon cleansing (OR adjusted 41.72 [95% CI 12.57-138.57], p value < 0.001); chronic laxative (OR adjusted 4.86 [95% CI 1.08-21.79], p value = 0.039); antidepressant (OR adjusted 5.00 [95% CI 1.65-15.16], p value = 0.004), and impaired mobility (OR adjusted 5.54 [95% CI 1.17-26.31], p value = 0.031) were independently associated with the outcome inadequate cleansing, after adjusting for confoundment. The model presented an excellent discriminative power towards the outcome variable (AUC ROC 0.937 [CI 95% 0.899-0.975], p value < 0.001). Conclusion: A previous inadequate colon cleansing, the use of chronic laxative and antidepressant, or impaired mobility are predictors of inadequate colon capsule cleansing, as assessed by the CC-CLEAR. These 4 predictors come together as a model enabling an accurate categorization of the patients at major risk of inadequate bowel preparation for capsule colonoscopy, with an excellent discriminative power and performance, which seems useful for the selection of patients for tailored optimization of the colon cleansing protocol.


Introdução: Com o intuito de otimizar a taxa de preparações intestinais adequadas em cápsula do cólon, poderá ser importante identificar fatores de risco preditivos de preparações sub-ótimas. Objetivo: Definir fatores preditivos de preparação intestinal inadequada em cápsula do colon, de acordo com a CC-CLEAR (Colon Capsule CLEansing Assessment and Report). Métodos: Estudo de coorte retrospetivo, no qual as variáveis demográficas, clínicas e a qualidade de preparação intestinal, de acordo com a CCCLEAR, foram colhidas retrospetivamente. Uma análise univariada testou a associação entre as covariáveis e a variável outcome ­ preparação intestinal inadequada. As variáveis estatisticamente significativas foram incluídas num modelo de regressão logística binária e performance testada com a realização de curva ROC. Resultados: Incluímos 167 cápsulas do colon consecutivas. Sessenta e oito por cento (n = 114) eram do sexo feminino, com idade média de 64 anos. A principal indicação para cápsula do colon foi uma colonoscopia prévia incompleta, em 158 indivíduos (94.6%). As preparações intestinais em cápsula do colon foram classificadas como boas ou excelentes em 96 indivíduos (57.5%) e como inadequadas em 71 (42.5%), de acordo com a CC-CLEAR. As variáveis preparação cólica prévia inadequada [OR ajustado 41.72 (95% CI 12.57­138.57) valor p < 0.001]; uso crónico de laxante [OR ajustado 4.86 (95% CI 1.08­21.79) valor p = 0.039]; antidepressivo [OR ajustado 5.00 (95% CI 1.65­15.16) valor p = 0.004] e défice de mobilidade [OR ajustado 5.54 (95% CI 1.17­26.31) valor p = 0.031] foram independentemente associadas ao outcome, preparação intestinal inadequada, após o ajuste para o confundimento. O modelo apresentou um excelente poder discriminativo em relação ao outcome [AUC ROC 0.937 (CI95% 0.899­0.975) valor p < 0.001]. Conclusão: Uma preparação cólica prévia inadequada, o uso crónico de laxantes e antidepressivos e um défice de mobilidade são preditores de preparação intestinal inadequada em cápsula do cólon, de acordo com a CC-CLEAR. Estas 4 variáveis formam um modelo que permite a categorização, com excelente acuidade, de indivíduos com risco elevado para preparação intestinal inadequada em cápsula do colon, o que parece ser útil para uma otimização caso a caso do protocolo de preparação intestinal.

12.
Artigo em Inglês | MEDLINE | ID: mdl-35601985

RESUMO

An 18-year-old boy presented with a giant midline mass with 9 years of evolution. The tumor was excised, and reconstruction made with a customized sternum implant and a free latissimus dorsi muscle flap with skin graft. Histological analysis was compatible with low-grade fibromyxoid sarcoma (LGFMS).

13.
Artigo em Inglês | MEDLINE | ID: mdl-35295792

RESUMO

The most used vessels for free flap breast reconstruction are the internal mammary, the thoracodorsal and the circumflex scapular. We present a case where those were inadequate. DIEP vessels were passed through a created sternal groove and anastomosed to the contralateral IM vessels, accessed by the breast symmetrisation incisions.

14.
Scand J Gastroenterol ; 57(5): 625-632, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35068293

RESUMO

BACKGROUND: Colon Capsule Cleansing Assessment and Report (CC-CLEAR) is a novel quantitative bowel preparation scale for colon capsule. AIM: The aim of this study is to validate the association between CC-CLEAR's classification and major CC outcomes: lesion detection rate, surveillance recommendations and post-CC endoscopic treatment. METHODS: Multicentric cohort of consecutive CCs. An expert's panel decided post-CC recommendations. Data included CC-CLEAR and Leighton-REX scales. Major CC outcomes were associated with the different cleansing grades. RESULTS: From 168 CC's included, findings were reported in 123 (73.2%), 67 (54.4%) of those being colorectal polyps. CC-CLEAR influenced CC's lesion detection (OR 1.25 95% IC [1.07-1.46], p-value .004) and polyp detection rate (OR 1.22 95% IC [1.04-1.43], p-value.014). Thirty-two (19%) post-CC colonoscopies were recommended, including 22 (68.75%) with at least one polypectomy. CC-CLEAR was associated with post-CC colonoscopy treatment (OR 1.40 95% IC [1.07-1.84], p-value .015). Regarding surveillance, CC-CLEAR influenced the decision for immediate CC repetition (OR 0.21 95% IC [0.12-0.36], p-value < .001) and the recommendation for CC in 3-5 years' time (OR 1.47 95% IC [1.50-1.86], p-value < .002). The Leighton-Rex scale was not correlated with major CC outcomes. CONCLUSION: CC-CLEAR impacts major CC outcomes: lesion detection, surveillance recommendations and post-CC endoscopic treatment.


Assuntos
Pólipos do Colo , Catárticos , Estudos de Coortes , Colo/patologia , Pólipos do Colo/diagnóstico , Pólipos do Colo/patologia , Colonoscopia , Humanos
15.
Dig Dis Sci ; 67(4): 1278-1286, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34291329

RESUMO

BACKGROUND: Optimal strategies for using small-bowel capsule endoscopy (SBCE) in established small-bowel Crohn's disease (CD) remain uncertain. Mucosal healing (MH) has emerged as a valuable predictor of a flare-free disease. We aimed to evaluate the occurrence of disease flare on patients with small-bowel CD and MH, as well as to create a score identifying patients in higher risk for this outcome. METHODS: We analyzed consecutive patients submitted to SBCE for assessment of MH and included those where MH was confirmed. The incidence of disease flare was assessed during follow-up (minimum 12 months). A score predicting disease flare was created from several analyzed variables. RESULTS: From 47 patients with MH, 12 (25.5%) had a flare (versus 48.3% in excluded patients without MH; p = 0.01). Age ≤ 30 years (OR  = 70; p  = 0.048), platelet count ≥ 280 × 103/L (OR  = 12.24; p  =  0.045) and extra-intestinal manifestations (OR  =  11.76; p  =  0.033) were associated with increased risk of CD flare during the first year after SBCE with MH. These variables were used to compute a risk-predicting score-the APEX score-which assigned the patients to having low (0-3 points) or high-risk (4-7 points) of disease flare and had excellent accuracy toward predicting disease relapse (AUC  =  0.82; 95%CI 0.64-0.99). CONCLUSION: Patients with small-bowel CD and MH were not free of disease flares on the subsequent year, despite presenting lower rates when compared to those without MH. The APEX score demonstrated excellent accuracy at stratifying patients relapse risk and guiding further therapeutic options for patients achieving MH.


Assuntos
Endoscopia por Cápsula , Doença de Crohn , Adulto , Doença de Crohn/tratamento farmacológico , Humanos , Mucosa Intestinal/diagnóstico por imagem , Intestino Delgado , Índice de Gravidade de Doença , Cicatrização
16.
J Gastroenterol Hepatol ; 37(2): 310-318, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34555864

RESUMO

BACKGROUND AND AIM: The RHEMITT score (Renal disease; Heart failure; Endoscopic findings; Major bleeding; Incomplete SBCE; Tobacco; Treatment by enteroscopy) was the first score to accurately predict the individual risk of small bowel rebleeding after capsule endoscopy (SBCE). The aim of the study is on the prospective validation of the RHEMITT score. METHODS: Cohort of consecutive patients with mid-gastrointestinal bleeding (MGIB) submitted to SBCE and followed prospectively, during at least 12 months, since 2017 until 2020. Rebleeding was defined as an overt bleeding event (melena or hematochezia) or a hemoglobin decrease of at least 2 g/dL. The RHEMITT score was calculated for each patient and the rebleeding rates compared. The performance of the score was tested by calculating the area under curve of the receiver operator characteristic curve. A rebleeding-free survival was assessed, corresponding to the period between the date of SBCE and the date of the first post-SBCE rebleeding event. RESULTS: We included 162 patients, 102 (62.9%) were female, with a mean age of 64 years old. The sensitivities and specificities of the score grades for predicting rebleeding were as following: for low-risk patients, 0% (0-10%) and 28.8% (21.1-36.5%); for intermediate-risk patients, 23.3% (8.2-38.4%) and 72% (64.3-79.7%); for high-risk patients, 76.7% (61.6-91.8%) and 99.2% (97.7-100%), corresponding to an area under curve of the receiver operator characteristic of 0.988 (P < 0.001). Kaplan-Meyer plots were statistically different according to the attributed risk (log-rank P value <0.001; Breslow-Wilcoxon P value <0.001). CONCLUSION: The RHEMITT score performed with excellent discriminative power in predicting rebleeding risk, and we herewith propose a surveillance of MGIB patients guided by the RHEMITT score.


Assuntos
Endoscopia por Cápsula , Hemorragia Gastrointestinal , Medição de Risco , Idoso , Endoscopia por Cápsula/efeitos adversos , Feminino , Hemorragia Gastrointestinal/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Reprodutibilidade dos Testes , Medição de Risco/métodos
17.
Endosc Int Open ; 9(11): E1602-E1610, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34790521

RESUMO

Background and study aims Polyethylene glycol (PEG) bowel preparations are effective but associated with high ingestion volume. In this study, 1-L PEG and 2-L PEG preparations were compared in a randomized, colonoscopist-blinded, single-center trial. Patients and methods Patients were aged > 18 years, required colonoscopy, and provided informed consent. Randomization was 1:1 to 1-L PEG or 2-L PEG, based on hospital identification number (odd or even). Preparations were administered using same-day dosing adjusted for colonoscopy start time. The primary endpoint was successful bowel preparation on the Boston Bowel Preparation Scale (BBPS) (no segment scored < 2). Results A total of 852 patients were randomized. In the intention-to-treat (ITT) population, significantly more patients had diabetes in the 2-L PEG arm, resulting in the creation of the modified-ITT population (mITT) that excluded diabetic patients to correct the imbalance (1-L PEG, n = 239; 2-L PEG, n = 238). In the mITT, there was no significant difference in successful cleansing between 1-L PEG and 2-L PEG (88.3 % vs. 82.4 %; P  = 0.067). Excellent cleansing (BBPS 7-9; no segment < 2) was significantly improved with 1-L PEG (60.7 % vs. 50.4 %; P  < 0.024), as were mean scores in the right and left colon (right: 2.47 vs. 2.30; P  < 0.008; left: 2.55 vs. 2.39; P  = 0.008). Adverse events were mild to moderate in intensity and none resulted in discontinuation. Rates of nausea and vomiting were significantly higher with 1-L PEG, but that did not affect successful cleansing. Conclusions The lower-volume 1-L PEG was associated with higher levels of excellent bowel cleansing and greater mean segmental scores on the BBPS than 2-L PEG.

19.
Artigo em Inglês | MEDLINE | ID: mdl-33946746

RESUMO

Tools to identify good practices in the design, implementation, and evaluation of physical activity community-based interventions (PACIs) are key to address the physical inactivity pandemic. Existing tools tend to be extensive and with limited applicability to assess small-scale PACIs. This work aimed to report the development and preliminary validity results of a simple, practical, and user-friendly tool to evaluate PACIs in local/municipal contexts. Eighty-six good practice characteristics defined by the World Health Organization (WHO), the Joint Action Framework on Chronic Diseases (CHRODIS), and an umbrella review of good practice characteristics of diet and physical activity interventions were initially extracted and refined in four rounds of revision from an expert panel using a Delphi-type methodology and rated on their relative importance. A pilot application was conducted, and data on the tool usability and applicability were collected through three semi-structured interviews with specialists and coordinators of local/municipal PACIs. For preliminary validation, the refined tool was applied to five community-based programs mostly aimed at an elderly population. The final tool included thirty-four selected characteristics, with a brief explanation and practical examples for each, under three main sections: design, evaluation, and implementation. Each characteristic has a rating (i.e., somewhat important, highly important, mandatory) and a percentage weight. Preliminary validation of this tool pointed to an adequate evaluation of good practice characteristics of municipal PACIs in a reliable, practical, and user-friendly way. Given its adequacy, this tool can support the definition of quality standards for PACIs, encouraging their dissemination and adoption at a regional or national level.


Assuntos
Dieta , Exercício Físico , Idoso , Doença Crônica , Promoção da Saúde , Humanos , Comportamento Sedentário
20.
Rev Esp Enferm Dig ; 113(10): 709-713, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33486962

RESUMO

BACKGROUND: small-bowel capsule endoscopy (SBCE) is the gold standard for the study of small-bowel bleeding (SBB). Recent studies suggest that longer small-bowel transit times (SBTT) may be associated with a higher diagnostic yield of SBCE. AIM: the aim of the study was to investigate if longer SBTT is a predictive factor of positive findings on SBCE in a population that underwent SBCE for suspected SBB. METHODS: a retrospective single-center study including consecutive SBCEs between May 2012 and May 2019, due to suspected SBB. A positive SBCE was considered in the presence of lesions with high bleeding potential such as ulcers, angioectasias, and tumors (P2 lesions, according to the Saurin classification). RESULTS: we included 372 patients, 65.9 % female, with a median age of 67 (IQR: 19-97) years. We observed that patients with P2 lesions (n = 131; 35.2 %) in SBCE exhibited a longer SBTT (p = 0.01), were older (p < 0.001), were more frequently male (p = 0.019), and suffered more frequently from arterial blood hypertension (p = 0.011), diabetes (p = 0.042), chronic kidney disease (p = 0.003), and heart failure (p = 0.001). In the logistic analysis, significant predictive factors for the presence of P2 lesions included age (OR: 1.027; 95 % CI: 1.009-1.045; p = 0.004), SBTT (OR: 1.002; 95 % CI: 1.001-1.005; p = 0.029), and male gender (OR: 1.588; 95 % CI: 1.001-2.534; p = 0.049). CONCLUSIONS: patients with longer SBTT had higher rates of lesions with high bleeding potential (P2). SBTT along with previously well-defined factors such as age and male gender were the only independent predictive factors for the presence of P2 lesions. These findings may suggest that a slower passage of the capsule through the small bowel may allow a better diagnostic yield for significant lesions.


Assuntos
Endoscopia por Cápsula , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/etiologia , Humanos , Intestino Delgado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Úlcera , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA