Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38781099

RESUMO

AIMS: Cardioneuroablation (CNA) is a catheter-based intervention for recurrent vasovagal syncope (VVS) that consists in the modulation of the parasympathetic cardiac autonomic nervous system. This survey aims to provide a comprehensive overview of current CNA utilization in Europe. METHODS AND RESULTS: A total of 202 participants from 40 different countries replied to the survey. Half of the respondents have performed a CNA during the last 12 months, reflecting that it is considered a treatment option of a subset of patients. Seventy-one per cent of respondents adopt an approach targeting ganglionated plexuses (GPs) systematically in both the right atrium (RA) and left atrium (LA). The second most common strategy (16%) involves LA GP ablation only after no response following RA ablation. The procedural endpoint is frequently an increase in heart rate. Ganglionated plexus localization predominantly relies on an anatomical approach (90%) and electrogram analysis (59%). Less utilized methods include pre-procedural imaging (20%), high-frequency stimulation (17%), and spectral analysis (10%). Post-CNA, anticoagulation or antiplatelet therapy is prescribed, with only 11% of the respondents discharging patients without such medication. Cardioneuroablation is perceived as effective (80% of respondents) and safe (71% estimated <1% rate of procedure-related complications). Half view CNA emerging as a first-line therapy in the near future. CONCLUSION: This survey offers a snapshot of the current implementation of CNA in Europe. The results show high expectations for the future of CNA, but important heterogeneity exists regarding indications, procedural workflow, and endpoints of CNA. Ongoing efforts are essential to standardize procedural protocols and peri-procedural patient management.


Assuntos
Ablação por Cateter , Síncope Vasovagal , Humanos , Síncope Vasovagal/fisiopatologia , Síncope Vasovagal/cirurgia , Síncope Vasovagal/diagnóstico , Europa (Continente) , Ablação por Cateter/métodos , Fluxo de Trabalho , Frequência Cardíaca , Resultado do Tratamento , Pesquisas sobre Atenção à Saúde , Padrões de Prática Médica/tendências , Técnicas Eletrofisiológicas Cardíacas , Inquéritos e Questionários , Gânglios Autônomos/cirurgia , Gânglios Autônomos/fisiopatologia , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Recidiva
3.
JACC Clin Electrophysiol ; 10(6): 1090-1100, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38639700

RESUMO

BACKGROUND: Recurrence of paroxysmal atrial fibrillation (AF) following pulmonary vein isolation (PVI) is presumably caused by pulmonary vein (PV) reconnections. However, there is little data available on the durability of PVI and incidence of arrhythmia recurrence in patients with persistent AF. OBJECTIVES: The purpose of this study was to evaluate the lesion durability by means of an a priori planned remapping procedure in patients with persistent AF undergoing CLOSE-guided PVI. METHODS: In a prospective study, we included patients with symptomatic, persistent AF undergoing CLOSE-guided radiofrequency ablation. Irrespective of AF recurrence, a redo procedure was mandated 6 months following the index procedure to evaluate PV reconnections. The outcome of AF ablation was based on clinical recurrence and 7-day Holter electrocardiogram 3 and 6 months after the index procedure and 3, 6, and 12 months after the redo procedure. RESULTS: Of 30 patients included, 26 (81% men; median age 68 years) underwent the planned remapping study a median of 6 months after the index procedure, whereas 4 patients without recurrence refused a repeat procedure. In total, 78 of 102 (76%) PVs showed durable isolation and 15 patients (58%) presented complete isolation of all PVs. Beyond the blanking period, 6 of 26 patients (23%) had arrhythmia recurrence before the redo procedure. Recurrence had occurred in 33% of patients with complete isolation of all veins and in 9% of patients with PV reconnections (P = 0.197). After re-PVI in patients with PV reconnections and additional ablation in patients with recurrence but durable PVI, 17 of 26 patients (65%) were free of arrhythmia after 12 months. CONCLUSIONS: In patients with persistent AF, CLOSE-guided PVI resulted in durable rate of PVI on a per-vein and per-patient level of 76% and 58%, respectively. Arrhythmia recurrence was numerically higher in patients with durable PVI compared with patients without.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Veias Pulmonares/cirurgia , Masculino , Feminino , Estudos Prospectivos , Idoso , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Pessoa de Meia-Idade , Resultado do Tratamento , Eletrocardiografia Ambulatorial , Reoperação/estatística & dados numéricos
4.
JACC Clin Electrophysiol ; 10(4): 698-708, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38340118

RESUMO

BACKGROUND: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology with high procedural safety and efficiency for pulmonary vein isolation (PVI). Premarket data showed high PVI durability during mandatory remapping studies. Data on lesion durability in real-world patients with clinically indicated redo procedures are scarce. OBJECTIVES: This study sought to report PVI durability rates in patients undergoing a clinically indicated redo procedure after an index PVI using PFA. METHODS: Patients from 7 European centers undergoing an index PVI using PFA were included the EU-PORIA (European Real-world Outcomes With Pulsed Field Ablation in Patients With Symptomatic Atrial Fibrillation) registry. In patients with subsequent left atrial redo procedures due to arrhythmia recurrence, 3-dimensional electroanatomical maps were acquired. PVI durability was assessed on a per-vein and per-patient level, and sites of reconnections and predictors of lesion durability were identified. RESULTS: Of 1,184 patients (62% paroxysmal atrial fibrillation) undergoing an index PVI using PFA, 272 (23%) had an arrhythmia recurrence. Of these, 144 (53%) underwent a left atrial redo procedure a median of 7 (Q1-Q3: 5-10) months after the first ablation. Three-dimensional electroanatomical maps identified 404 of 567 pulmonary veins (71%) with durable isolation. In 54 patients (38%), all pulmonary veins were durably isolated. Prior operator experience with cryoballoon ablation was associated with a higher PVI durability compared to operators with only point-by-point radiofrequency experience (76% vs 60%; P < 0.001). Neither the operators' cumulative experience in atrial fibrillation ablation (≤5 vs >5 years) nor the size of the PFA device used (31 mm vs 35 mm) had an impact on subsequent lesion durability (both P > 0.50). CONCLUSIONS: In 144 patients with arrhythmia recurrence after PFA PVI, durable isolation was observed in 71% of the pulmonary veins during the redo procedure, and 38% of all patients showed durable isolation of all veins.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Sistema de Registros , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Masculino , Feminino , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Idoso , Europa (Continente) , Resultado do Tratamento , Recidiva , Reoperação/estatística & dados numéricos
5.
J Interv Card Electrophysiol ; 67(3): 503-511, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37523023

RESUMO

BACKGROUND: A novel multipolar pulsed-field ablation (PFA) catheter has recently been introduced for pulmonary vein isolation (PVI). Pre-market data showed high rates for PVI-durability during mandatory remapping studies. OBJECTIVE: To present post-market data in patients with recurrent arrhythmias. METHODS: Consecutive patients undergoing a redo procedure after an index PFA PVI using a bipolar-biphasic PFA system were included. 3-D electro-anatomical maps (3D-EAM) on redo procedure were compared to the 3D-EAM acquired after ablation during the index procedure. PVI durability was assessed on a per-vein and per-patient level and the sites of reconnections were identified. Furthermore, lesion extent around veins with durable isolation was compared to study lesion regression. RESULTS: Of 341 patients treated with a PFA PVI, 29 (8.5%) underwent a left atrial redo ablation due to arrhythmia recurrence. At the end of the index procedure, 110/112 veins (98%, four common ostia) were isolated. On redo procedures performed a median of 6 months after the first ablation, 3D-EAM identified 69/110 (63%) PVs with durable isolation. In 6 (21%) patients, all PVs were durably isolated. Reconnections were more often found on the right-sided veins and on the anterior aspects of the upper veins. Only minor lesion regression was observed between the index and redo procedure (a median of 3 mm (0 - 9.5) on the posterior wall). CONCLUSION: In patients with arrhythmia recurrence after PFA PVI using a first-generation PFA device, durable isolation was observed in 63% of the veins and 21% of the patients showed durable isolation of all previously isolated veins.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Átrios do Coração/cirurgia , Criocirurgia/métodos , Reoperação/métodos , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
6.
J Interv Card Electrophysiol ; 67(2): 389-397, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37776355

RESUMO

BACKGROUND: Pulsed-field ablation (PFA) has shown favourable data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI). We sought to compare procedural and 1-year follow-up data of patients with paroxysmal atrial fibrillation (AF) undergoing PVI using PFA, cryoballoon ablation (CBA) and radiofrequency ablation (RFA). METHODS: Consecutive patients with paroxysmal AF undergoing a first PVI with PFA at our institution were included. For comparison, patients with paroxysmal AF undergoing a first PVI with CBA and RFA were selected using a 1:2:2 propensity score matching. The PFA group followed the standard 32-applications lesion-set protocol, the CBA group a time-to-effect plus 2-min strategy, and the RFA group the CLOSE protocol. Patients were followed with 7d-Holter ECGs 3, 6, and 12 months after ablation. The primary endpoint was recurrence of atrial tachyarrhythmia (ATa) following a blanking period of 3 months. RESULTS: A total of 200 patients were included (PFA n = 40; CBA n = 80; RFA n = 80). Median procedure times were shortest with CBA (75 min) followed by PFA (94 min) and RFA (182 min; p < 0.001). Fluoroscopy dose was lowest with RFA (1.6Gycm2) followed by PFA (5.0Gycm2) and CBA (5.7Gycm2; p < 0.001). After a 1-year follow-up, freedom from ATa recurrence was 85.0% with PFA, 66.2% with CBA and 73.8% with RFA (p = 0.12 PFA vs. CBA; p = 0.27 PFA vs. RFA). CONCLUSION: In a propensity score matched analysis of patients with paroxysmal AF, freedom from any ATa 1 year after PVI using PFA was favourable and at least as good as for PVI with CBA or RFA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Ablação por Radiofrequência , Humanos , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Pontuação de Propensão , Resultado do Tratamento , Criocirurgia/métodos , Ablação por Cateter/métodos , Recidiva
7.
Contemp Clin Trials ; 134: 107341, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37722483

RESUMO

INTRODUCTION: Single-shot devices are increasingly used for pulmonary vein isolation (PVI) in atrial fibrillation (AF). The Arctic Front cryoballoon (Medtronic) is the most frequently used single-shot technology. A recently developed novel cryoballoon has been introduced (PolarX, Boston Scientific) with the aim to address limitations of the Arctic Front system. METHODS: COMPARE CRYO is a multicentre, randomized, controlled trial with blinded endpoint adjudication by an independent clinical events committee. A total of 200 patients with paroxysmal AF undergoing their first PVI are randomized 1:1 between PolarX cryoballoon ablation and Arctic Front cryoballoon ablation. Continuous monitoring during follow-up is performed using an implantable cardiac monitor (ICM) in all patients. The primary endpoint is time to first recurrence of any atrial tachyarrhythmia (AF, atrial flutter, and/or atrial tachycardia) ≥ 120 s between days 91 and 365 post ablation as detected on the (ICM). Procedural safety is assessed by a composite of cardiac tamponade, persistent phrenic nerve palsy >24 h, vascular complications requiring intervention, stroke/transient ischemic attack, atrioesophageal fistula or death occurring during or up to 30 days after the procedure. Key secondary endpoints include (1) procedure and fluoroscopy times, (2) AF burden, (3) proportion of patients with recurrence in the blanking period, (4) proportion of patients undergoing repeat ablation, and (5) quality of life changes at 12 months compared to baseline. CONCLUSION: COMPARE CRYO will compare the efficacy and safety of the novel PolarX cryoballoon and the standard-of-practice Arctic Front cryoballoon for first PVI performed in patients with symptomatic paroxysmal AF. TRIAL REGISTRATION: (ClinicalTrials.gov ID: NCT04704986).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Veias Pulmonares/cirurgia , Qualidade de Vida , Criocirurgia/métodos , Ablação por Cateter/métodos , Recidiva , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
8.
Eur Heart J ; 44(27): 2458-2469, 2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37062040

RESUMO

AIMS: Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management, and outcome are sparse. METHODS AND RESULTS: This international multicentre registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553 729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed, at 214 centres in 35 countries. In 78 centres 138 patients [0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (P < 0.0001)] were diagnosed with an oesophageal fistula. Peri-procedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0-60) days and 21 (15, 29.5; range: 2-63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0-42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8% and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) [odds ratio 7.463 (2.414, 23.072) P < 0.001]. CONCLUSION: Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fístula Esofágica , Humanos , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Resultado do Tratamento , Incidência , Fatores de Risco , Fístula Esofágica/epidemiologia , Fístula Esofágica/etiologia , Fístula Esofágica/diagnóstico , Prognóstico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
10.
Europace ; 24(12): 1926-1932, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-35727739

RESUMO

AIMS: The aim of the study was to compare the 1-year efficacy and safety of a novel cryoballoon (NCB) ablation system (POLARx; Boston Scientific) for pulmonary vein isolation (PVI) compared with the standard cryoballoon (SCB) system (Arctic Front, Medtronic). METHODS AND RESULTS: Consecutive patients with atrial fibrillation (AF) undergoing PVI using the NCB and the SCB at two centres were included. We report 1-year efficacy after 12 months, short-term safety and hospitalizations within the blanking period, and predictors for AF recurrence. In case of repeat procedures, pulmonary vein (PV) reconnection patterns were characterized. Eighty patients (age 66 ± 10 years, ejection fraction 57 ± 10%, left atrial volume index 39 ± 13 mL/m2, paroxysmal AF in 64%) were studied. After a single procedure and a follow-up of 12 months, 68% in the NCB group and 70% in the SCB group showed no recurrence of AF/atrial tachycardias (P = 0.422). One patient in the NCB group suffered a periprocedural stroke with full recovery. There were no differences regarding hospitalizations during follow-up between the groups. PV reconnection observed during 12 repeat procedures (4 NCB, 8 SCB) pattern was comparable between the groups with more reconnections in the right-sided compared with the left-sided PVs. CONCLUSION: In this multicentre study comparing two currently available cryoballoon ablation systems for PVI, no differences were observed in the efficacy and safety during a follow-up of 12 months.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
11.
J Interv Card Electrophysiol ; 64(2): 409-416, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34319493

RESUMO

PURPOSE: The aim was to report procedural and technical differences of a novel cryoballoon (NCB) ablation catheter for pulmonary vein isolation (PVI) compared to the standard cryoballoon (SCB) catheter. METHODS: Consecutive patients with atrial fibrillation (AF) undergoing PVI using the NCB and the SCB were included. Procedural parameters, technical differences, acute efficacy, and safety are reported. RESULTS: Eighty patients (age 66 ± 10 years, ejection fraction 57 ± 10%, left atrial volume index 40 ± 6 ml/m2) were studied. With the NCB, 156 of 158 PVs (99%) were isolated compared to isolation of 159 of 159 PVs (100%) with the SCB. The median number of freezes in the NCB and the SCB group was 6 (IQR 5-8) and 5 (IQR 4-7), respectively (p = 0.051), with 73% and 71% of the PVs isolated with a single freeze, respectively. Nadir temperature and temperature at isolation were - 59 ± 6 °C and - 45 ± 17 °C in the NCB group and - 46 ± 7 °C and - 32 ± 23 °C in the SCB group, respectively (both p < 0.001) with no difference in time to isolation (TTI). Procedural differences were observed for the total procedure time (84 ± 29 min in the NCB group and 65 ± 17 min in the SCB group, p = 0.003). There was a peri-procedural stroke in one patient in the NCB group. Differences in catheter design were observed that may account for the differences in temperature recordings and ice cap formation. CONCLUSIONS: Acute efficacy and TTI were similar with the NCB compared to the SCB. Measured temperatures were lower with the NCB, most likely due to differences in catheter design.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/cirurgia , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
12.
J Thromb Haemost ; 19(4): 931-940, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33501722

RESUMO

OBJECTIVE: Balancing bleeding risk and stroke risk in patients with atrial fibrillation (AF) is a common challenge. Though several bleeding risk scores exist, most have not included patients on direct oral anticoagulants (DOACs). We aimed at developing a novel bleeding risk score for patients with AF on oral anticoagulants (OAC) including both vitamin K antagonists (VKA) and DOACs. METHODS: We included patients with AF on OACs from a prospective multicenter cohort study in Switzerland (SWISS-AF). The outcome was time to first bleeding. Bleeding events were defined as major or clinically relevant non-major bleeding. We used backward elimination to identify bleeding risk variables. We derived the score using a point score system based on the ß-coefficients from the multivariable model. We used the Brier score for model calibration (<0.25 indicating good calibration), and Harrel's c-statistics for model discrimination. RESULTS: We included 2147 patients with AF on OAC (72.5% male, mean age 73.4 ± 8.2 years), of whom 1209 (56.3%) took DOACs. After a follow-up of 4.4 years, a total of 255 (11.9%) bleeding events occurred. After backward elimination, age > 75 years, history of cancer, prior major hemorrhage, and arterial hypertension remained in the final prediction model. The Brier score was 0.23 (95% confidence interval [CI] 0.19-0.27), the c-statistic at 12 months was 0.71 (95% CI 0.63-0.80). CONCLUSION: In this prospective cohort study of AF patients and predominantly DOAC users, we successfully derived a bleeding risk prediction model with good calibration and discrimination.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Estudos de Coortes , Feminino , Hemorragia/induzido quimicamente , Hemorragia/tratamento farmacológico , Hemorragia/epidemiologia , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Suíça
13.
Swiss Med Wkly ; 150: w20343, 2020 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-33035354

RESUMO

INTRODUCTION: Sudden cardiac death caused by malignant arrhythmia can be prevented by the use of defibrillators. Although the wearable cardioverter defibrillator (WCD) can prevent such an event, its role in clinical practice is ill defined. We investigated the use of the WCD in Switzerland with emphasis on prescription rate, therapy adherence and treatment rate. MATERIALS AND METHODS: The Swiss WCD Registry is a retrospective observational registry including patients using a WCD. Patients were included from the first WCD use in Switzerland until February 2018. Baseline characteristics and data on WCD usage were examined for the total study population, and separately for each hospital. RESULTS: From 1 December 2011 to 18 February 2018, a total of 456 patients (67.1% of all WCDs prescribed in Switzerland and 81.1% of all prescribed in the participating hospitals) were included in the registry. Up to 2017 there was a yearly increase in the number of prescribed WCDs to a maximum of 271 prescriptions per year. The mean age of patients was 57 years (± 14), 81 (17.8%) were female and mean left ventricular ejection fraction (EF) was 32% (± 13). The most common indications for WCD use were new-onset ischaemic cardiomyopathy (ICM) with EF ≤35% (206 patients, 45.2%), new-onset nonischaemic cardiomyopathy (NICM) with EF ≤35% (115 patients, 25.2%), unknown arrhythmic risk (83 patients, 18.2%), bridging to implantable cardioverter-defibrillator implantation or heart transplant (37 patients, 8.1%) and congenital/inherited heart disease (15 patients, 3.3%). Median wear duration was 58 days (interquartile range [IQR] 31–94) with a median average daily wear time of 22.6 hours (IQR 20–23.2). Seventeen appropriate therapies from the WCD were delivered in the whole population (treatment rate: 3.7%) to a total of 12 patients (2.6% of all patients). The most common underlying heart disease in patients with a treatment was ICM (13/17, 76.5%). There were no inappropriate treatments. CONCLUSION: The use of WCDs has increased in Switzerland over the years for a variety of indications. There is high therapy adherence to the WCD, and a treatment rate comparable to previously published registry data.  .


Assuntos
Desfibriladores Implantáveis , Dispositivos Eletrônicos Vestíveis , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Sistólico , Suíça , Função Ventricular Esquerda
14.
Front Cardiovasc Med ; 7: 108, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32671101

RESUMO

Ventricular tachycardia (VT) caused by myocardial scaring bears a significant risk of mortality and morbidity. Antiarrhythmic drug therapy (AAD) and catheter ablation remain the cornerstone of VT management, but both treatments have limited efficacy and potential adverse effects. Stereotactic body radiotherapy (SBRT) is routinely used in oncology to treat non-invasively solid tumors with high precision and efficacy. Recently, this technology has been evaluated for the treatment of VT. This review presents the basic underlying principles, proof of concept, and main results of trials and case series that used SBRT for the treatment of VT refractory to AAD and catheter ablation.

15.
Interact Cardiovasc Thorac Surg ; 30(3): 373-379, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31800041

RESUMO

OBJECTIVES: Our goal was to analyse the implantation and outcome of thoracoscopic epicardial leads after a failed endovascular approach or follow-up (FU) complications after endovascular implantation. METHODS: We reviewed the records of patients with failed endovascular left ventricular (LV) lead placement or complications during FU, who were subsequently referred to cardiac surgeons for treatment with thoracoscopic LV lead implantation. We analysed the reasons for endovascular failure; the indications for the surgical procedures; and the clinical, echocardiographic and device FU results. RESULTS: Between 2010 and 2013, a total of 23 patients were included. Among them, 17 of the patients had no previous cardiothoracic surgery, 13 (76%) had successful video-assisted thoracoscopy (VAT) LV lead implantation, 3 (18%) had a conversion to thoracotomy and 1 (6%) failed. Of the 6 patients with prior cardiothoracic surgery, 2 (33%) had VAT only, 3 (50%) had primary thoracotomies and 1 (17%) had a conversion. Two major complications occurred. The reasons for LV endovascular lead failure were subclavian vein occlusion (n = 2), implant failure (n = 13) and complications during the FU period (n = 8). FU information was available for 20 patients: 17 (85%) had improved symptoms. The median FU period was 33 months. A total of 78% of patients were in New York Heart Association (NYHA) functional class III-IV before the operation; 30% were in NYHA functional class III-IV at the last FU examination. The left ventricular ejection fraction increased from 25% before surgery to 31% at the last FU examination. Overall, sensing and pacing threshold values remained stable over time. In 1 patient, lead revision was necessary due to an increase in the pacing threshold. CONCLUSIONS: VAT implantation of LV leads had an excellent response rate with an improvement in NYHA functional class and left ventricular ejection fraction. The lead measurements were mainly stable over time.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Eletrodos Implantados , Insuficiência Cardíaca/terapia , Pericárdio/cirurgia , Volume Sistólico/fisiologia , Cirurgia Torácica Vídeoassistida/métodos , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Função Ventricular Esquerda
17.
J Electrocardiol ; 49(2): 174-81, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26774549

RESUMO

OBJECTIVE: Abnormal ECG findings suggestive of cardiac disease are frequent in patients with funnel chest, although structural heart disease is rare. Electrocardiographic characteristics and changes following new surgical treatments in young adults are not described so far. The aim of the study was to analyze electrocardiographic characteristics of patients with funnel chest before and after minimally invasive funnel chest correction by the Nuss procedure. METHODS: Twenty-six patients with surgical correction of funnel chest using pectus bar were included. Twelve-lead ECGs before and later than one year after surgery were analyzed. RESULTS: In postoperative ECGs, amplitude of P wave in lead II and negative terminal amplitude of P wave in lead V1 decreased from 0.13 to 0.10mV (p=0.03), and from 0.10 to 0.04mV (p<0.001), respectively. Mean QRS duration decreased from 108ms to 98ms (p=0.003) after correction. A pathological left and right Sokolow-Lyon index was observed in 35% and 23% of patients before, versus 8% (p=0.04) and 0% (p=0.01) after correction, respectively. In contrast, the rate of patients with J wave pattern in precordial leads V4-V6 increased from 8% before to 42% after surgery (p=0.004). CONCLUSIONS: ECG abnormalities in patients with funnel chest are frequent, and can normalize after surgical correction by the Nuss procedure. De novo J wave pattern in precordial leads V4-V6 is a frequent finding after surgical funnel chest correction using pectus bar.


Assuntos
Eletrocardiografia/métodos , Tórax em Funil/diagnóstico , Tórax em Funil/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Próteses e Implantes , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Cuidados Pós-Operatórios/métodos , Cuidados Pré-Operatórios/métodos , Desenho de Prótese , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento , Adulto Jovem
18.
Swiss Med Wkly ; 146: w14376, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28102875

RESUMO

AIMS OF THE STUDY: Sudden cardiac arrest in athletes is a rare but dramatic event. The value of a routine electrocardiogram (ECG) during preparticipation screening (PPS) remains controversial, partly because of the relatively high number of false positive findings. Our study aimed to evaluate the prevalence of abnormal ECGs in consecutive Swiss elite athletes, overall and with regard to different sports classes, using modern screening criteria. METHODS: We analysed the 12-lead resting ECGs of high-level elite athletes (age ≥14 years) recorded at the Swiss Olympic Medical Centre Magglingen between 2013 and 2016 during routine PPS. The overall prevalence of abnormal ECGs was evaluated and compared in accordance with the original and revised Seattle criteria. Sports disciplines were categorised according to their static (estimated percentage of maximal voluntary contraction, I-III) and dynamic (estimated percentage of maximal oxygen uptake, A-C) components, and the prevalence of abnormal ECGs compared between sports classes by Fisher's exact test (with alpha set at 0.05). RESULTS: ECGs from 287 consecutive athletes were analysed (64.1% male; 99.7% Caucasian; median age 20.4 ± 4.9 years; median weekly training volume 17.7 ± 7.1 hours). Based on original Seattle criteria, eight (2.8%) ECGs were classified as abnormal: three T-wave inversion (TWI), one Q-wave duration >40 ms, two QRS left axis deviation, two Q-wave amplitude >3 mm. The use of the revised Seattle criteria reduced the number of abnormal ECGs to four (1.4%): three TWI, one Q-wave duration >40 ms. Further cardiological work-up revealed an underlying structural heart disease in only one of these four athletes (inferolateral TWI on ECG), consisting of very localised mid-wall fibrosis suggestive of former myocarditis. There was a significant difference in occurrence of abnormal ECGs between the different sports categories (p = 0.018). All four abnormal ECGs according to the revised Seattle criteria occurred in the high dynamic sport classes (IIC and IIIC); three out of the four were found in the high dynamic high static class (IIIC). CONCLUSIONS: In our cohort of high-level elite athletes, the prevalence of abnormal ECGs according to modern screening criteria was very low. All athletes with an abnormal ECG performed high dynamic sports. Less than one percent of our athletes had a new relevant cardiac diagnosis.


Assuntos
Atletas/estatística & dados numéricos , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia/estatística & dados numéricos , Cardiopatias/diagnóstico por imagem , Programas de Rastreamento/métodos , Adolescente , Morte Súbita Cardíaca/epidemiologia , Reações Falso-Positivas , Feminino , Coração/diagnóstico por imagem , Cardiopatias/epidemiologia , Humanos , Masculino , Prevalência , Esportes/fisiologia , Suíça/epidemiologia , Adulto Jovem
19.
Heart Rhythm ; 13(4): 894-902, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26592849

RESUMO

BACKGROUND: Inferolateral early repolarization (ER) is highly prevalent and is associated with idiopathic ventricular fibrillation (VF). OBJECTIVE: The purpose of this study was to evaluate the potential role of T-wave parameters to differentiate between malignant and benign ER. METHODS: We compared the ECGs of patients with ER and VF (n = 92) with control subjects with asymptomatic ER (n = 247). We assessed J-wave amplitude, QTc interval, T-wave/R-wave (T/R) ratio in leads II and V5, and presence of low-amplitude T waves (T-wave amplitude <0.1 mV and <10% of R-wave amplitude in lead I, II, or V4-V6). RESULTS: Compared to controls, the VF group had longer QTc intervals (388 ms vs. 377 ms, P = .001), higher J-wave amplitudes (0.23 mV vs. 0.17 mV, P <.001), higher prevalence of low-amplitude T waves (29% vs. 3%, P <.001), and lower T/R ratio (0.18 vs. 0.30, P <.001). Logistic regression analysis demonstrated that QTc interval (odds ratio [OR] per 10 ms: 1.15, 95% confidence interval [CI} 1.02-1.30), maximal J-wave amplitude (OR per 0.1 mV: 1.68, 95% CI 1.23-2.31), lower T/R ratio (OR per 0.1 unit: 0.62, 95% CI 0.47-0.81), presence of low-amplitude T waves (OR 3.53, 95% CI 1.26-9.88). and presence of J waves in the inferior leads (OR 2.58, 95% CI 1.18-5.65) were associated with malignant ER. CONCLUSION: Patients with malignant ER have a higher prevalence of low-amplitude T waves, lower T/R ratio (lead II or V5), and longer QTc interval. The combination of these parameters with J-wave amplitude and distribution of J waves may allow for improved identification of malignant ER.


Assuntos
Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Fibrilação Ventricular/diagnóstico , Adulto , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/fisiopatologia
20.
Circ Arrhythm Electrophysiol ; 8(1): 18-24, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25528745

RESUMO

BACKGROUND: This study aimed to determine 5-year efficacy of catheter ablation for persistent atrial fibrillation (AF) using AF termination as a procedural end point. METHODS AND RESULTS: One hundred fifty patients (57±10 years) underwent persistent AF ablation using a stepwise ablation approach (pulmonary vein isolation, electrogram-guided, and linear ablation) with the desired procedural end point being AF termination. Repeat ablation was performed for recurrent AF or atrial tachycardia. AF was terminated by ablation in 120 patients (80%). Arrhythmia-free survival rates after a single procedure were 35.3%±3.9%, 28.0%±3.7%, and 16.8%±3.2% at 1, 2, and 5 years, respectively. Arrhythmia-free survival rates after the last procedure (mean 2.1±1.0 procedures) were 89.7%±2.5%, 79.8%±3.4%, and 62.9%±4.5%, at 1, 2, and 5 years, respectively. During a median follow-up of 58 (interquartile range, 43-73) months after the last ablation procedure, 97 of 150 (64.7%) patients remained in sinus rhythm without antiarrhythmic drugs. Another 14 (9.3%) patients maintained sinus rhythm after reinitiation of antiarrhythmic drugs, and an additional 15 (10.0%) patients regressed to paroxysmal recurrences only. Failure to terminate AF during the index procedure (hazard ratio 3.831; 95% confidence interval, 2.070-7.143; P<0.001), left atrial diameter≥50 mm (hazard ratio 2.083; 95% confidence interval, 1.078-4.016; P=0.03), continuous AF duration≥18 months (hazard ratio 1.984; 95% confidence interval, 1.024-3.846; P<0.04), and structural heart disease (hazard ratio 1.874; 95% confidence interval, 1.037-3.388; P=0.04) predicted arrhythmia recurrence. CONCLUSIONS: In patients with persistent AF, an ablation strategy aiming at AF termination is associated with freedom from arrhythmia recurrence in the majority of patients over a 5-year follow-up period. Procedural AF nontermination and specific baseline factors predict long-term outcome after ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Intervalo Livre de Doença , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Fatores de Risco , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/cirurgia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA