Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Brain Commun ; 5(6): fcad292, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37953844

RESUMO

Intracranial EEG is the gold standard technique for epileptogenic zone localization but requires a preconceived hypothesis of the location of the epileptogenic tissue. This placement is guided by qualitative interpretations of seizure semiology, MRI, EEG and other imaging modalities, such as magnetoencephalography. Quantitative abnormality mapping using magnetoencephalography has recently been shown to have potential clinical value. We hypothesized that if quantifiable magnetoencephalography abnormalities were sampled by intracranial EEG, then patients' post-resection seizure outcome may be better. Thirty-two individuals with refractory neocortical epilepsy underwent magnetoencephalography and subsequent intracranial EEG recordings as part of presurgical evaluation. Eyes-closed resting-state interictal magnetoencephalography band power abnormality maps were derived from 70 healthy controls as a normative baseline. Magnetoencephalography abnormality maps were compared to intracranial EEG electrode implantation, with the spatial overlap of intracranial EEG electrode placement and cerebral magnetoencephalography abnormalities recorded. Finally, we assessed if the implantation of electrodes in abnormal tissue and subsequent resection of the strongest abnormalities determined by magnetoencephalography and intracranial EEG corresponded to surgical success. We used the area under the receiver operating characteristic curve as a measure of effect size. Intracranial electrodes were implanted in brain tissue with the most abnormal magnetoencephalography findings-in individuals that were seizure-free postoperatively (T = 3.9, P = 0.001) but not in those who did not become seizure-free. The overlap between magnetoencephalography abnormalities and electrode placement distinguished surgical outcome groups moderately well (area under the receiver operating characteristic curve = 0.68). In isolation, the resection of the strongest abnormalities as defined by magnetoencephalography and intracranial EEG separated surgical outcome groups well, area under the receiver operating characteristic curve = 0.71 and area under the receiver operating characteristic curve = 0.74, respectively. A model incorporating all three features separated surgical outcome groups best (area under the receiver operating characteristic curve = 0.80). Intracranial EEG is a key tool to delineate the epileptogenic zone and help render individuals seizure-free postoperatively. We showed that data-driven abnormality maps derived from resting-state magnetoencephalography recordings demonstrate clinical value and may help guide electrode placement in individuals with neocortical epilepsy. Additionally, our predictive model of postoperative seizure freedom, which leverages both magnetoencephalography and intracranial EEG recordings, could aid patient counselling of expected outcome.

2.
Epilepsia Open ; 8(3): 1151-1156, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37254660

RESUMO

Successful epilepsy surgery depends on localizing and resecting cerebral abnormalities and networks that generate seizures. Abnormalities, however, may be widely distributed across multiple discontiguous areas. We propose spatially constrained clusters as candidate areas for further investigation and potential resection. We quantified the spatial overlap between the abnormality cluster and subsequent resection, hypothesizing a greater overlap in seizure-free patients. Thirty-four individuals with refractory focal epilepsy underwent pre-surgical resting-state interictal magnetoencephalography (MEG) recording. Fourteen individuals were totally seizure-free (ILAE 1) after surgery and 20 continued to have some seizures post-operatively (ILAE 2+). Band power abnormality maps were derived using controls as a baseline. Patient abnormalities were spatially clustered using the k-means algorithm. The tissue within the cluster containing the most abnormal region was compared with the resection volume using the dice score. The proposed abnormality cluster overlapped with the resection in 71% of ILAE 1 patients. Conversely, an overlap only occurred in 15% of ILAE 2+ patients. This effect discriminated outcome groups well (AUC = 0.82). Our novel approach identifies clusters of spatially similar tissue with high abnormality. This is clinically valuable, providing (a) a data-driven framework to validate current hypotheses of the epileptogenic zone localization or (b) to guide further investigation.


Assuntos
Epilepsia Resistente a Medicamentos , Magnetoencefalografia , Humanos , Mapeamento Encefálico , Resultado do Tratamento , Convulsões , Epilepsia Resistente a Medicamentos/cirurgia , Análise por Conglomerados
3.
Epilepsia ; 64(3): 692-704, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36617392

RESUMO

OBJECTIVE: Epilepsy surgery fails to achieve seizure freedom in 30%-40% of cases. It is not fully understood why some surgeries are unsuccessful. By comparing interictal magnetoencephalography (MEG) band power from patient data to normative maps, which describe healthy spatial and population variability, we identify patient-specific abnormalities relating to surgical failure. We propose three mechanisms contributing to poor surgical outcome: (1) not resecting the epileptogenic abnormalities (mislocalization), (2) failing to remove all epileptogenic abnormalities (partial resection), and (3) insufficiently impacting the overall cortical abnormality. Herein we develop markers of these mechanisms, validating them against patient outcomes. METHODS: Resting-state MEG recordings were acquired for 70 healthy controls and 32 patients with refractory neocortical epilepsy. Relative band-power spatial maps were computed using source-localized recordings. Patient and region-specific band-power abnormalities were estimated as the maximum absolute z-score across five frequency bands using healthy data as a baseline. Resected regions were identified using postoperative magnetic resonance imaging (MRI). We hypothesized that our mechanistically interpretable markers would discriminate patients with and without postoperative seizure freedom. RESULTS: Our markers discriminated surgical outcome groups (abnormalities not targeted: area under the curve [AUC] = 0.80, p = .003; partial resection of epileptogenic zone: AUC = 0.68, p = .053; and insufficient cortical abnormality impact: AUC = 0.64, p = .096). Furthermore, 95% of those patients who were not seizure-free had markers of surgical failure for at least one of the three proposed mechanisms. In contrast, of those patients without markers for any mechanism, 80% were ultimately seizure-free. SIGNIFICANCE: The mapping of abnormalities across the brain is important for a wide range of neurological conditions. Here we have demonstrated that interictal MEG band-power mapping has merit for the localization of pathology and improving our mechanistic understanding of epilepsy. Our markers for mechanisms of surgical failure could be used in the future to construct predictive models of surgical outcome, aiding clinical teams during patient pre-surgical evaluations.


Assuntos
Epilepsia Resistente a Medicamentos , Epilepsia , Neocórtex , Humanos , Magnetoencefalografia/métodos , Eletroencefalografia/métodos , Neocórtex/patologia , Epilepsia/cirurgia , Imageamento por Ressonância Magnética , Epilepsia Resistente a Medicamentos/cirurgia , Resultado do Tratamento
4.
Brain ; 146(6): 2389-2398, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36415957

RESUMO

More than half of adults with epilepsy undergoing resective epilepsy surgery achieve long-term seizure freedom and might consider withdrawing antiseizure medications. We aimed to identify predictors of seizure recurrence after starting postoperative antiseizure medication withdrawal and develop and validate predictive models. We performed an international multicentre observational cohort study in nine tertiary epilepsy referral centres. We included 850 adults who started antiseizure medication withdrawal following resective epilepsy surgery and were free of seizures other than focal non-motor aware seizures before starting antiseizure medication withdrawal. We developed a model predicting recurrent seizures, other than focal non-motor aware seizures, using Cox proportional hazards regression in a derivation cohort (n = 231). Independent predictors of seizure recurrence, other than focal non-motor aware seizures, following the start of antiseizure medication withdrawal were focal non-motor aware seizures after surgery and before withdrawal [adjusted hazard ratio (aHR) 5.5, 95% confidence interval (CI) 2.7-11.1], history of focal to bilateral tonic-clonic seizures before surgery (aHR 1.6, 95% CI 0.9-2.8), time from surgery to the start of antiseizure medication withdrawal (aHR 0.9, 95% CI 0.8-0.9) and number of antiseizure medications at time of surgery (aHR 1.2, 95% CI 0.9-1.6). Model discrimination showed a concordance statistic of 0.67 (95% CI 0.63-0.71) in the external validation cohorts (n = 500). A secondary model predicting recurrence of any seizures (including focal non-motor aware seizures) was developed and validated in a subgroup that did not have focal non-motor aware seizures before withdrawal (n = 639), showing a concordance statistic of 0.68 (95% CI 0.64-0.72). Calibration plots indicated high agreement of predicted and observed outcomes for both models. We show that simple algorithms, available as graphical nomograms and online tools (predictepilepsy.github.io), can provide probabilities of seizure outcomes after starting postoperative antiseizure medication withdrawal. These multicentre-validated models may assist clinicians when discussing antiseizure medication withdrawal after surgery with their patients.


Assuntos
Epilepsias Parciais , Epilepsia Generalizada , Epilepsia , Humanos , Adulto , Anticonvulsivantes/efeitos adversos , Recidiva Local de Neoplasia/tratamento farmacológico , Epilepsia/tratamento farmacológico , Epilepsia/cirurgia , Convulsões/tratamento farmacológico , Epilepsia Generalizada/tratamento farmacológico
5.
Brain Commun ; 3(2): fcab072, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33977268

RESUMO

Both magnetoencephalography and stereo-electroencephalography are used in presurgical epilepsy assessment, with contrasting advantages and limitations. It is not known whether simultaneous stereo-electroencephalography-magnetoencephalography recording confers an advantage over both individual modalities, in particular whether magnetoencephalography can provide spatial context to epileptiform activity seen on stereo-electroencephalography. Twenty-four adult and paediatric patients who underwent stereo-electroencephalography study for pre-surgical evaluation of drug-resistant focal epilepsy, were recorded using simultaneous stereo-electroencephalography-magnetoencephalography, of which 14 had abnormal interictal activity during recording. The 14 patients were divided into two groups; those with detected superficial (n = 7) and deep (n = 7) brain interictal activity. Interictal spikes were independently identified in stereo-electroencephalography and magnetoencephalography. Magnetoencephalography dipoles were derived using a distributed inverse method. There was no significant difference between stereo-electroencephalography and magnetoencephalography in detecting superficial spikes (P = 0.135) and stereo-electroencephalography was significantly better at detecting deep spikes (P = 0.002). Mean distance across patients between stereo-electroencephalography channel with highest average spike amplitude and magnetoencephalography dipole was 20.7 ± 4.4 mm. for superficial sources, and 17.8 ± 3.7 mm. for deep sources, even though for some of the latter (n = 4) no magnetoencephalography spikes were detected and magnetoencephalography dipole was fitted to a stereo-electroencephalography interictal activity triggered average. Removal of magnetoencephalography dipole was associated with 1 year seizure freedom in 6/7 patients with superficial source, and 5/6 patients with deep source. Although stereo-electroencephalography has greater sensitivity in identifying interictal activity from deeper sources, a magnetoencephalography source can be localized using stereo-electroencephalography information, thereby providing useful whole brain context to stereo-electroencephalography and potential role in epilepsy surgery planning.

6.
Epilepsy Behav ; 116: 107738, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33517199

RESUMO

About 30% of people with epilepsy (PWE) are drug-resistant. Those with focal seizures may be suitable for epilepsy surgery. Those not amenable to resective surgery can be considered for vagus nerve stimulation (VNS). However, after operative procedures, around 50% of patients continue to experience seizures. A multi-center retrospective study assessing perampanel effectiveness and tolerability for PWE who have undergone surgical resection and/or VNS implantation was performed. The primary outcome was ≥50% reduction in seizure frequency while secondary outcomes included side effects (SEs), dose-related effectiveness, and toxicity. The median perampanel dose was 6 mg. Only one PWE became seizure free. A ≥50% decrease in seizure frequency was observed in 52.8% of the post-resection group and 16.9% of the VNS group (p < 0.001), while SEs were seen in 44.8% and 41.1%, respectively. Perampanel doses greater than 8 mg led to better response in both groups, especially in the post-VNS cohort. SEs were not dose-related and the safety profile was similar to previous observational studies. Perampanel can be beneficial in these two super-refractory epilepsy groups, particularly in PWE with seizures after surgical resection. Doses of more than 8 mg appear to be well tolerated and may be more effective than lower doses in PWE after surgical interventions.


Assuntos
Epilepsia Resistente a Medicamentos , Epilepsia , Estimulação do Nervo Vago , Epilepsia Resistente a Medicamentos/terapia , Epilepsia/terapia , Humanos , Nitrilas , Piridonas , Estudos Retrospectivos , Resultado do Tratamento
7.
Front Neurol ; 11: 563847, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33071948

RESUMO

Objective: To investigate whether MEG network connectivity was associated with epilepsy duration, to identify functional brain network hubs in patients with refractory focal epilepsy, and assess if their surgical removal was associated with post-operative seizure freedom. Methods: We studied 31 patients with drug refractory focal epilepsy who underwent resting state magnetoencephalography (MEG), and structural magnetic resonance imaging (MRI) as part of pre-surgical evaluation. Using the structural MRI, we generated 114 cortical regions of interest, performed surface reconstruction and MEG source localization. Representative source localized signals for each region were correlated with each other to generate a functional brain network. We repeated this procedure across three randomly chosen one-minute epochs. Network hubs were defined as those with the highest intra-hemispheric mean correlations. Post-operative MRI identified regions that were surgically removed. Results: Greater mean MEG network connectivity was associated with a longer duration of epilepsy. Patients who were seizure free after surgery had more hubs surgically removed than patients who were not seizure free (AUC = 0.76, p = 0.01) consistently across three randomly chosen time segments. Conclusion: Our results support a growing literature implicating network hub involvement in focal epilepsy, the removal of which by surgery is associated with greater chance of post-operative seizure freedom.

8.
Pract Neurol ; 20(1): 4-14, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31420415

RESUMO

Epilepsy surgery offers the chance of seizure remission for the 30%-40% of patients with focal epilepsy whose seizures continue despite anti-epileptic medications. Epilepsy surgery encompasses curative resective procedures, palliative techniques such as corpus callosotomy and implantation of stimulation devices. Pre-surgical evaluation aims to identify the epileptogenic zone and to prevent post-operative neurological and cognitive deficits. This entails optimal imaging, prolonged video-electroencephalogram (EEG) recordings, and neuropsychological and psychiatric assessments; some patients may then require nuclear medicine imaging and intracranial EEG recording. The best outcomes are in those with an electro-clinically concordant structural lesion on MRI (60%-70% seizure freedom). Lower rates of seizure freedom are expected in people with extra-temporal lobe foci, focal-to-bilateral tonic-clonic seizures, normal structural imaging, psychiatric co-morbidity and learning disability. Nevertheless, surgery for epilepsy is under-used and should be considered for all patients with refractory focal epilepsy in whom two or three anti-epileptic medications have been ineffective.


Assuntos
Epilepsia Resistente a Medicamentos/cirurgia , Epilepsias Parciais/cirurgia , Monitorização Neurofisiológica Intraoperatória/métodos , Cuidados Pré-Operatórios/métodos , Convulsões/cirurgia , Anticonvulsivantes/uso terapêutico , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Epilepsia Resistente a Medicamentos/tratamento farmacológico , Eletroencefalografia/métodos , Epilepsias Parciais/diagnóstico por imagem , Epilepsias Parciais/tratamento farmacológico , Humanos , Convulsões/diagnóstico por imagem , Convulsões/tratamento farmacológico , Técnicas Estereotáxicas
9.
Clin Neurophysiol ; 130(5): 845-855, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30824202

RESUMO

OBJECTIVE: Interictal high resolution (HR-) electric source imaging (ESI) and magnetic source imaging (MSI) are non-invasive tools to aid epileptogenic zone localization in epilepsy surgery candidates. We carried out a systematic review on the diagnostic accuracy and quality of evidence of these modalities. METHODS: Embase, Pubmed and the Cochrane database were searched on 13 February 2017. Diagnostic accuracy studies taking post-surgical seizure outcome as reference standard were selected. Quality appraisal was based on the QUADAS-2 framework. RESULTS: Eleven studies were included: eight MSI (n = 267), three HR-ESI (n = 127) studies. None was free from bias. This mostly involved: selection of operated patients only, interference of source imaging with surgical decision, and exclusion of indeterminate results. Summary sensitivity and specificity estimates were 82% (95% CI: 75-88%) and 53% (95% CI: 37-68%) for overall source imaging, with no statistical difference between MSI and HR-ESI. Specificity is higher when partially concordant results were included as non-concordant (p < 0.05). Inclusion of indeterminate test results as non-concordant lowered sensitivity (p < 0.05). CONCLUSIONS: Source imaging has a relatively high sensitivity but low specificity for identification of the epileptogenic zone. SIGNIFICANCE: We need higher quality studies allowing unbiased test evaluation to determine the added value and diagnostic accuracy of source imaging in the presurgical workup of refractory focal epilepsy.


Assuntos
Mapeamento Encefálico/métodos , Eletroencefalografia , Epilepsia/cirurgia , Imageamento por Ressonância Magnética , Magnetoencefalografia , Epilepsia/diagnóstico por imagem , Epilepsia/fisiopatologia , Humanos , Sensibilidade e Especificidade
10.
Epilepsia ; 57(5): 770-6, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27012361

RESUMO

OBJECTIVE: In 2014 the European Union-funded E-PILEPSY project was launched to improve awareness of, and accessibility to, epilepsy surgery across Europe. We aimed to investigate the current use of neuroimaging, electromagnetic source localization, and imaging postprocessing procedures in participating centers. METHODS: A survey on the clinical use of imaging, electromagnetic source localization, and postprocessing methods in epilepsy surgery candidates was distributed among the 25 centers of the consortium. A descriptive analysis was performed, and results were compared to existing guidelines and recommendations. RESULTS: Response rate was 96%. Standard epilepsy magnetic resonance imaging (MRI) protocols are acquired at 3 Tesla by 15 centers and at 1.5 Tesla by 9 centers. Three centers perform 3T MRI only if indicated. Twenty-six different MRI sequences were reported. Six centers follow all guideline-recommended MRI sequences with the proposed slice orientation and slice thickness or voxel size. Additional sequences are used by 22 centers. MRI postprocessing methods are used in 16 centers. Interictal positron emission tomography (PET) is available in 22 centers; all using 18F-fluorodeoxyglucose (FDG). Seventeen centers perform PET postprocessing. Single-photon emission computed tomography (SPECT) is used by 19 centers, of which 15 perform postprocessing. Four centers perform neither PET nor SPECT in children. Seven centers apply magnetoencephalography (MEG) source localization, and nine apply electroencephalography (EEG) source localization. Fourteen combinations of inverse methods and volume conduction models are used. SIGNIFICANCE: We report a large variation in the presurgical diagnostic workup among epilepsy surgery centers across Europe. This diversity underscores the need for high-quality systematic reviews, evidence-based recommendations, and harmonization of available diagnostic presurgical methods.


Assuntos
Epilepsia/diagnóstico por imagem , Epilepsia/fisiopatologia , Neuroimagem , Epilepsia/cirurgia , Europa (Continente)/epidemiologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Cooperação Internacional , Masculino , Neuroimagem/métodos , Neuroimagem/estatística & dados numéricos , Neuroimagem/tendências , Inquéritos e Questionários
11.
Ann Neurol ; 52(3): 327-34, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12205645

RESUMO

Band heterotopia is a malformation of cortical development characterized by bands of gray matter in the white matter parallel to the surface of the neocortex. Histopathological studies have suggested that small white matter tracts pass through the heterotopia, and functional magnetic resonance imaging studies have shown activation in the malformation. We used diffusion tractography to explore the anatomical connectivity of band heterotopia and, in particular, whether in vivo white matter tracts traverse the heterotopic gray matter. Five patients with band heterotopia and five control subjects were scanned with whole brain diffusion tensor imaging. Anisotropy maps were calculated. Using fast marching tractography, we produced maps of connectivity and tract traces from two seed points, in the splenium of the corpus callosum and the right parietal lobe. Eigenvectors were found to pass through the band heterotopia in an aligned fashion. Patterns for maps of connectivity were similar in patients and control subjects. Areas of high connectivity were found in the band heterotopia and in cortical areas on the far side of the malformation from the seed point. The tracts hence appeared to traverse or end within the band heterotopia. The results are in agreement with previous histopathological studies and indicate the structural basis of the functional connectivity and absence of focal deficits in these patients.


Assuntos
Agenesia do Corpo Caloso , Coristoma/patologia , Fibras Nervosas/patologia , Vias Neurais/anormalidades , Lobo Parietal/anormalidades , Adulto , Anisotropia , Mapeamento Encefálico/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA