Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Ann Vasc Surg ; 84: 55-60, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35257913

RESUMO

BACKGROUND: Reducing fluoroscopy times and iodine contrast administration during endovascular repair (EVAR) of infrarenal aortic aneurysms remains a challenge. The purpose of this study is to evaluate the preliminary results of a fully ultrasound-assisted EVAR without iodine contrast administration. METHODS: Twenty-seven consecutive patients underwent an elective intravascular ultrasound (IVUS)-assisted EVAR with final contrast-enhanced ultrasound (CEUS) control of correct aneurysm exclusion. In no case intraprocedural injection of iodine contrast medium was performed. The primary study's end points were the overall duration of the procedure, duration of fluoroscopy, cumulative radiation dose, the length of intraoperative CEUS control, and the comparison of findings between intraoperative CEUS and computed tomography (CT) scan at 1 month. RESULTS: Mean duration of the procedure was 130 ± 35 min. Overall duration of fluoroscopy was 22 ± 18 min. Mean radiation dose was 66 mGy (range 24-82). The mean length of CEUS final control was 8 ± 2 min. No type I or type III endoleak was detected either at CEUS or at angio-CT scan at 1 month from EVAR. CEUS revealed a type II endoleak in 6 patients (22%), compared to 9 type II endoleaks (33%) detected at angio-CT scan 1 month after the procedure (P = 0.5). CONCLUSIONS: Fully ultrasound (IVUS and CEUS)-assisted EVAR is safe, feasible, and reliable, completely eliminating the need for iodine contrast medium and reducing the radiation exposure for both patients and surgeons.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Iodo , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/etiologia , Aneurisma da Aorta Abdominal/cirurgia , Aortografia/efeitos adversos , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Meios de Contraste/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Procedimentos Endovasculares/efeitos adversos , Humanos , Resultado do Tratamento
2.
Int J Angiol ; 29(4): 245-249, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33268975

RESUMO

Evaluation of the outcomes of OSES (oval-shaped external support), a novel device for external valvuloplasty of the great saphenous vein (GSV) for the conservative treatment of superficial venous insufficiency. Between 2012 and 2015, 30 patients underwent external valvuloplasty of the GSV for a total of 32 limbs. Patients were subjected to clinical and instrumental follow-up by a half-year ultrasound for a minimum of 36 months. The main endpoints were the recurrence of varicose disease, persistent or recurrent venous reflux, and venous thrombosis. Varicose recurrence was verified in six limbs on 32 (18.75%). Four limbs (12.5%) presented a recurrence of the reflux even in the absence of varicose veins. Two limbs (6.25%) underwent saphenectomy after the valvuloplasty intervention at 12 and 18 months, respectively, because of the presence of saphenofemoral reflux and varicose recurrences. No case of venous thrombosis of the saphenous trunk was observed. The external valvuloplasty of the GSV is a well-known technique that used to treat the superficial venous insufficiency. The newly introduced OSES device seems to show better midterm results, due to a better alignment of the valve flaps. In our experience, the use of this device gives better long-term results and allowed to extend the indication to patients with saphenic diameters that were considered not eligible for repair. In conclusion, although our data needs further confirmation, OSES device might represents a new interesting opportunity for reconstructive venous surgery.

3.
Ann Vasc Surg ; 64: 54-61, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31726201

RESUMO

BACKGROUND: The aim of this study was to compare intravascular ultrasound (IVUS) assistance for endovascular aortic aneurysm repair (EVAR) to standard assistance by angiography. METHODS: From June 2015 to June 2017, 173 consecutive patients underwent EVAR. In this group, 69 procedures were IVUS-assisted with X-ray exposure limited to completion angiography for safety purposes because an IVUS probe does not yet incorporate a duplex probe (group A), and 104 were angiography-assisted procedures (group B). All IVUS-assisted procedures were performed by vascular surgeons with basic duplex ultrasound (DUS) training. The primary study endpoints were mean radiation dose, duration of fluoroscopy, amount of contrast media administered, procedure-related outcomes, and renal clearance expressed as the glomerular filtration rate (GFR) before and after the procedure. Secondary endpoints were operative mortality, morbidity, and arterial access complications. RESULTS: Mean duration of fluoroscopy time was significantly lower for IVUS-assisted procedures (24 ± 15 min vs. 40 ± 30 min for angiography-assisted procedures, P < 0.01). Moreover, mean radiation dose (Air KERMA) was significantly lower in IVUS-assisted procedures (76m Gy [44-102] vs. 131 mGy [58-494]), P < 0.01. IVUS-assisted procedures required fewer contrast media than standard angiography-assisted procedures (60 ± 20 mL vs. 120 ± 40 mL, P < 0.01). The mean duration of the procedure was comparable in the two groups (120 ± 30 min vs. 140 ± 30 min, P = 0.07). No difference in renal clearance before and after the procedure was observed in either of the two groups (99.0 ± 4/97.8 ± 2 mL/min in group A and 98.0 ± 3/97.6 ± 5 mL/min in group B) (P = 0.28). The mean length of follow-up was nine months (6-30 months). No postoperative mortality, morbidity, or arterial access complications occurred. No type 1 endoleak was observed. Early type II endoleaks were observed in 21 patients (11%), 12 in the angiography-assisted group (11%) and nine in the IVUS-assisted group (12%). They were not associated with sac enlargement ≥5 mm diameter and therefore did not require any additional treatment. CONCLUSIONS: Compared with standard angiography-assisted EVAR, IVUS significantly reduces renal load with contrast media, fluoroscopy time, and radiation dose while preserving endograft deployment efficiency. Confirmation from a large prospective study with improved IVUS probes will be required before IVUS-assisted EVAR alone can become standard practice.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia , Procedimentos Endovasculares , Radiografia Intervencionista , Ultrassonografia de Intervenção , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/cirurgia , Meios de Contraste/administração & dosagem , Meios de Contraste/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Projetos Piloto , Complicações Pós-Operatórias/mortalidade , Valor Preditivo dos Testes , Doses de Radiação , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/efeitos adversos , Radiografia Intervencionista/mortalidade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
Chir Ital ; 55(4): 561-4, 2003.
Artigo em Italiano | MEDLINE | ID: mdl-12938603

RESUMO

Laparoscopic surgery has been increasingly used in different fields of surgery. This report concerns the authors' experience with combined laparoscopic cholecystectomy and symptomatic renal cyst decortication. The mean diameter of the cysts was 11.2 cm. and involved the left and right kidney in 3 and 1 patient, respectively. All cysts were peripheral. Surgery was performed using 4 trocars in 3 cases and 5 trocars in the other. The mean operative time was 110 minutes and mean blood loss 40 cc. Postoperative pain was minimal. The mean duration of postoperative ileus was 2.2 days. No significant complications were observed. The mean postoperative hospital stay was 3.5 days. At follow-up examinations all patients were pain-free. Recurrence of the cyst was observed in only one case. Combined laparoscopic cholecystectomy and renal cyst decortication is technically feasible in selected cases and does not seem to significantly affect the perioperative course of cholecystectomy.


Assuntos
Colelitíase/cirurgia , Doenças Renais Císticas/cirurgia , Laparoscopia/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
Chir Ital ; 54(6): 879-81, 2002.
Artigo em Italiano | MEDLINE | ID: mdl-12613339

RESUMO

Cavernous haemangiomas of the adrenal gland are rare and the preoperative diagnosis is very difficult. We report the case of a patient admitted for aspecific abdominal pain. Instrumental diagnostic investigations (ultrasonography and CT scan) revealed an adrenal mass of uncertain interpretation which was surgically removed and histologically diagnosed as a cavernous haemangioma.


Assuntos
Neoplasias das Glândulas Suprarrenais , Hemangioma Cavernoso , Neoplasias das Glândulas Suprarrenais/diagnóstico , Neoplasias das Glândulas Suprarrenais/cirurgia , Feminino , Hemangioma Cavernoso/diagnóstico , Hemangioma Cavernoso/cirurgia , Humanos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA