Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Adv Exp Med Biol ; 1403: 171-200, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37495919

RESUMO

Ultrasound tomography (USCT) is a promising imaging modality, mainly aiming at early diagnosis of breast cancer. It provides three-dimensional, reproducible images of higher quality than conventional ultrasound methods and additionally offers quantitative information on tissue properties. This chapter provides an introduction to the background and history of USCT, followed by an overview of image reconstruction algorithms and system design. It concludes with a discussion of current and future applications as well as limitations and their potential solutions.


Assuntos
Neoplasias da Mama , Tomografia Computadorizada por Raios X , Humanos , Feminino , Ultrassonografia , Processamento de Imagem Assistida por Computador/métodos , Neoplasias da Mama/diagnóstico por imagem , Imageamento Tridimensional/métodos , Algoritmos , Imagens de Fantasmas , Tomografia/métodos
2.
Artigo em Inglês | MEDLINE | ID: mdl-37141062

RESUMO

A potential method for future breast cancer screening is 3-D ultrasound computed tomography (USCT). The utilized image reconstruction algorithms require transducer characteristics fundamentally different from conventional transducer arrays, leading to the necessity of a custom design. This design has to provide random transducer positioning, isotropic sound emission as well as a large bandwidth and wide opening angle. In this article, we present a new transducer array design to be utilized in a third generation 3-D USCT system. Each system requires 128 cylindrical arrays, mounted into the shell of a hemispherical measurement vessel. Each new array contains a 0.6 mm thick disk with 18 single PZT fibers (0.46 mm diameter) embedded in a polymer matrix. Randomized positioning of the fibers is achieved with an arrange-and-fill process. The single-fiber disks are connected on both ends with a matching and backing disk using simple stacking and adhesives. This enables fast and scalable production. We characterized the acoustic field of 54 transducers with a hydrophone. Measurements in 2-D showed isotropic acoustic fields. The mean bandwidth and opening angle are 131% and 42°, respectively (both -10 dB). The large bandwidth arises from two resonances within the utilized frequency range. Parameter studies using different models showed that the realized design is already close to the achievable optimum for the transducer technology used. Two 3-D USCT systems were equipped with the new arrays. First images show promising results, with an increase in image contrast and a significant reduction of artifacts.


Assuntos
Tomografia Computadorizada por Raios X , Transdutores , Imagens de Fantasmas , Desenho de Equipamento , Ultrassonografia/métodos
3.
Artigo em Inglês | MEDLINE | ID: mdl-25881342

RESUMO

Ultrasound is frequently used to evaluate suspicious masses in breasts. These evaluations could be improved by taking advantage of advanced imaging algorithms, which become feasible for low frequencies if accurate knowledge about the phase and amplitude of the wave field illuminating the volume of interest is available. In this study, we compare five imaging and inversion methods: time-of-flight tomography, synthetic aperture focusing technique, backpropagation, Born inversion, and contrast source inversion. All methods are tested on the same full-wave synthetic data representing a 2-D scan using a circular array enclosing a cancerous breast submerged in water. Of the tested methods, only contrast source inversion yielded an accurate reconstruction of the speed-ofsound profile of the tumor and its surroundings, because only this method takes effects such as multiple scattering, refraction, and diffraction into account.


Assuntos
Algoritmos , Neoplasias da Mama/diagnóstico por imagem , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Ultrassonografia Mamária/métodos , Feminino , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Clin Imaging ; 39(2): 225-30, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25537430

RESUMO

PURPOSE: 4D co-registration of X-ray- and MR-mammograms (XM and MM) is a new method of image fusion. The present study aims to evaluate its clinical feasibility, radiological accuracy, and potential clinical value. METHODS: XM and MM of 25 patients were co-registered. Results were evaluated by a blinded reader. RESULTS: Precision of the 4D co-registration was "very good" (mean-score [ms]=7), and lesions were "easier to delineate" (ms=5). In 88.8%, "relevant additional diagnostic information" was present, accounting for a more "confident diagnosis" in 76% (ms=5). CONCLUSION: 4D co-registration is feasible, accurate, and of potential clinical value.


Assuntos
Neoplasias da Mama/diagnóstico , Mamografia/métodos , Imagem Multimodal/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos
5.
Eur J Radiol ; 81 Suppl 1: S133-4, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23083562

RESUMO

A promising candidate for imaging of breast cancer is ultrasound computer tomography (USCT). The main advantages of a USCT system are simultaneous recording of reproducible reflection, attenuation and speed of sound volumes, high image quality, and fast data acquisition. The here presented 3D USCT prototype realizes for the first time the full potential of such a device. It is ready for a clinical study. Full volumes of a breast can be acquired in four minutes. In this paper images acquired with a clinical breast phantom are presented. The resolution and imaged details of the reflectivity reconstruction are comparable to a 3 tesla MRI volume of the phantom. Image quality and resolution is isotropic in all three dimensions, confirming the successful implementation experimentally.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/instrumentação , Intensificação de Imagem Radiográfica/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia
7.
Int J Comput Assist Radiol Surg ; 7(3): 339-48, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-21643945

RESUMO

PURPOSE: Breast cancer is the most common cancer among women. The established screening method to detect breast cancer is X-ray mammography. Additionally, MRI is used for diagnosis in clinical routine. Due to complementary diagnostic information, both modalities are often read in combination. Yet, the correlation is challenging due to different dimensionality of images and different patient positioning. In this paper, we describe a method to fuse X-ray mammograms with DCE-MRI. The present study was conducted to evaluate the feasibility of the approach. METHODS: For the combination of information from both modalities, the images have to be registered using a compression simulation based on a patient-specific biomechanical model. The registered images can be compared directly. The contrast enhancement in the DCE-MRI volume is evaluated using parametric enhancement maps. A projection image of the contrast enhancement is created. The image fusion combines it with X-ray mammograms for intuitive multimodal diagnosis. RESULTS: The image fusion was evaluated using 11 clinical datasets. For 10 of 11 datasets, a good accuracy of the image registration was achieved. The overlap of contrast-enhanced regions with marked lesions in the mammogram is 61%. Lesions are clearly differentiable from surrounding tissue by the DCE-MRI projection in 10 of 11 cases. CONCLUSION: The described preliminary results are promising, thus we expect the visualization of quantitative information from dynamic MRI together with mammograms to be beneficial for multimodal diagnosis. Because of the use of clinical standard modalities, no additional image acquisition is needed.


Assuntos
Neoplasias da Mama/diagnóstico , Meios de Contraste , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética , Mamografia/métodos , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA